The Bruker ICP-MS – a Versatile Tool for Sensitive and Interference Free Analysis of Different Matrices Title of sales presentation – Remarks: „Bruker.

Slides:



Advertisements
Similar presentations
Author: J R Reid Oxidation and Reduction – Introduction LEO goes GER Examples Balancing simple equations Why gain/lose electrons? Electronegativity.
Advertisements

Spectroscopy Lecture 4 Ahmad Razali Bin Ishak Department of Environmental Health Faculty of Health Sciences UiTM Puncak Alam.
Electrochemistry II. Electrochemistry Cell Potential: Output of a Voltaic Cell Free Energy and Electrical Work.
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
Writing Ionic Formulas Chemical Formulas from Names & Names from Chemical Formulas.
Year 12 Chemistry. Much of the work of chemists involves monitoring the reactants and products of reactions and managing reaction conditions.
AAS and FES (Ch 9, 7th e, WMDS)
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
Flame photometry.
Applications of Analytical Chemistry at RTI International  Argon plasma instruments Atomic Emission (ICP-AES) – 3 Quadrupole Mass Spectrometers (ICP-MS)
LEFT CLICK OR PRESS SPACE BAR TO ADVANCE, PRESS P BUTTON TO GO BACK, PRESS ESC BUTTON TO END LEFT CLICK OR PRESS SPACE BAR TO ADVANCE, PRESS P BUTTON.
Atomic Emission - AES M* → M + hn Thermal excitation M → M*
 Chemical reactions and physical processes on a large scale to convert raw materials into useful products.  Conditions of the reactions are controlled.
BALZ S. KAMBER Laurentian University Ultra-high purity ICP-MS.
Agilent 7500 ICP-MS Date: 28JUL2005.
LEFT CLICK OR PRESS SPACE BAR TO ADVANCE, PRESS P BUTTON TO GO BACK, PRESS ESC BUTTON TO END LEFT CLICK OR PRESS SPACE BAR TO ADVANCE, PRESS P BUTTON.
 Elemental classification  Lewis acid/base  Pearson’s hard/soft metals  Ionic and covalent index  Ionic potentials  Earth Scientist's Periodic Table.
in tin pest and pest free Monika Leodolter-Dvorak and Ilse Steffan
Metals, Nonmetals, Metalloids. Metals and Nonmetals Li 3 He 2 C6C6 N7N7 O8O8 F9F9 Ne 10 Na 11 B5B5 Be 4 H1H1 Al 13 Si 14 P 15 S 16 Cl 17 Ar 18 K 19 Ca.
Mass spectrometry Ions are analyzed on the basis of their m/z Chlorine has 2 isotopes, 35 Cl and 37 Cl, in the approximate ratio of 3 :1. Electrons are.
Atomic Absorption Spectroscopy
CHAPTER 2: The Chemistry of Life BIO 121. Chemistry is relevant… (even if we don’t like it)
Essential Elements.
Advances in Determinations of metals by ICPMS, from ultra-small sampling to ultra- trace analysis. AES Department Dr. Otto Herrmann Teresa Switzer May.
Laser Ablation ICP-MS at the University of Gothenburg
Measurement of “Difficult” Elements and Isotopes Using a Hexapole ICPMS Zenon Palacz, Simon Meffan-Main. Micromass U.K. Ltd.
BIONAD 18 Month Meeting July 7th, 2015, Inescop Premises, Elda (E) LIFE12 ENV/IT/352 Determination of trace elements in traditional dyes, naturalized dyes.
Less Manganese lost over C Manganese in Sea Water Excessive Background signal from NaCL Large loss of analyte.
00J ppt Rapid Extraction Methods for the Process Laboratory S. L. Maxwell, III V. D. Jones S. T. Nichols J. Satkowski M. A. Bernard Westinghouse.
Inductively Coupled Plasma-Mass Spectrometry ICP-MS Stuart Morrow June 12, 2015.
Aquatic Chemistry 367 Civil and Environmental Engineering Meeting time: MWF 11:00-11:50am Meeting room: Abbott Auditorium in Pancoe Pavillion Instructor:
ICP MAKING STANDARDS. NUMBER OF STANDARDS Determine the number of standards necessary for your measurements (Blank, 100ppb, 500ppb, 1000ppb, etc)
Activity Series A method for predicting reactions.
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/26/2006Chapter 3ICPMS Interference equations Isobaric.
Eliminating Molecular Interferences in ICP-MS for the Simplest Method Development Dr. Torsten Lindemann.
Net Ionic Equations And A Little Review.
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
The Islamic University of Gaza- Environmental Engineering Department
Fig Fig H Rb K Na Li Fr Cs Sr Ca Mg Be Ra Ba Y Sc Ac La Zr Ti Rf Hf Nb V Db Ta Mo Cr Sg W Tc Mn Bh Re Ru Fe Hs Os Rh Co Mt Ir Pd Ni Uun Pt.
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
Teacher Notes This PPT was revised June 10, This PPT is a review on the atomic characteristics of the four main essential elements hydrogen, carbon,
Science 9 Aim: Introduction to environmental chemistry.
Reactions of Metals. Reactions of Metals with H 2 O The metal is the anode and will be oxidized. 2H 2 O + 2e-  2OH - + H 2 E° = V Mg  Mg 2+ +
Transition Metals - Characteristics Electron configuration Oxidation States Catalysts Coloured Ions.
Periodic Table Li 3 He 2 C6C6 N7N7 O8O8 F9F9 Ne 10 Na 11 B5B5 Be 4 H1H1 Al 13 Si 14 P 15 S 16 Cl 17 Ar 18 K 19 Ca 20 Sc 21 Ti 22 V 23 Cr.
An in-depth look at trace metallic impurity determination by ICP-OES
S2 SCIENCE CHEMICAL REACTIONS
Metal or non-metal? iron (Fe) iodine (I) antimony (Sb) copper (Cu)
Introduction To Chemistry
THE HALOGENS.
Chapter 6: Chemical Bonding
This is the default title slide for Thermo Fisher Scientific
KS4 Chemistry Metallic Bonding.
THE TRANSITION METALS.
THE HALOGENS.
KS4 Chemistry Metallic Bonding.
9E Metals and Metal Compounds
THE TRANSITION METALS.
Binary Compounds NaCl sodium chlor ine ide (Na1+ Cl1-) CaS
The Analysis of Soils and Waters in Accordance with U. S
Soil processes and trace metals
Implementing EPA Method 6020 with the Agilent ICP-MS Portfolio
Metals and Metal Compounds
بر اساس جدول تناوبی از یک جایی به بعد فلزات سنگین قرار دارند
Atomic Absorption Spectroscopy. Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis.
DETECTION LIMITS < 1 ppt ng/L 1-10 ppt ng/L ppt ng/L
Increase in Ease of Oxidation
Presentation transcript:

The Bruker ICP-MS – a Versatile Tool for Sensitive and Interference Free Analysis of Different Matrices Title of sales presentation – Remarks: „Bruker Confidential“ needs to be erased (slide master!) for external use. 20.04.2017

Applications for ICP-MS Environmental Waters Analysis Drinking water Effluents from industrial sites Sea Water Analysis Most elements at ultra-trace levels Soil, Sediment and Land Site Contamination Trace and toxic elements Samples digested/leached in acids Agriculture and Food Food safety Toxic elements Pb, Cd, Hg, Cr, As Plants, Herbs Fertilizer, Animal Feed Food, Fruits and Beverages Toxic, essential and macrominerals Meats, Crops, Milk, Tea, Wine, Juice 20.04.2017

Applications for ICP-MS Clinical research Bloods, Serums, Urine, Tissues Complex matrix, viscous High levels of C, S, P, Na, Mg, Fe, Cl Trace, Toxic and Nutritional As, Pb, Tl, Th, Cd, Cr Se, Cu, Mn, Au, Pt I, Hg Geochemical Applications Soils Digestion required High TDS & matrix Rocks, Ceramics, Fly ash, Coal Possibly crushed & fused Al, Ca, Fe, K, Mg, Na, S, Cr, Cu, Ni, Pb, Zn Minerals and precious metals prospecting Gold and the PGEs (Pt, Pd, Rh, Ru, Ir and Os) Rare earth elements at trace levels 20.04.2017

Applications for ICP-MS Other Applications Industrial Cement and building products Nuclear Cooling water (10B/11B) Isotope ratios Forensic Gun powder residues Gold Characterization Purity Element fingerprinting to infer the origin of the material 20.04.2017

Diagram of ICP-MS Operations Vacuum Sample Detector Mass Analyser Ion Source Data Process 20.04.2017

ICP-MS Sample Preparation – Introduction Liquid samples (dilute), run Suspensions filtrate/digest, run Viscous samples dilute, run Powders and Solids digest (microwave), run S.G. P.G. A.G. N.G. Sample Flow To Waste P.G. – Plasma Gas A.G. – Auxiliary Gas N.G. – Nebulizer Gas S.G. – Sheath Gas 20.04.2017

High Performance Ion Optics 90 degree ion mirror Increased efficiency and sensitivity Reduced contamination Improved long term signal stability Simplified operation Maintenance-free Curved entrance rods Double off axis quadrupole Removes excited neutrals before they reach the quadrupole Lowest possible backgrounds Better detection limits

Ion Optics – working principle Ions Neutrals Photons 1 2 3 4 5 6 7 Extract lens-1 Extract lens-2 Extract lens-3 Corner Lens Mirror lens (L, R, B) Entrance Lens Entrance Plate

Bruker ICP-MS - Low Noise Quadrupol 1 1 Entrance lense S-shaped pre-Quadrupol 2 2 3 3 MHz Quadrupol 3

Schematic of the Detector Operation Control Section Signal Output Quadrupole Gain Control Ion to e-Conversion Amplification e- + The detector coverts ions into electrical pulses. Adjustment of voltage applied to control dynode provides attenuation of final output signal.

9 Orders Linear Dynamic Range 10 ppt 100 1 ppb ppm 0.1 % Normal-sensitivity- Mode 1 MHz 1 GHz Ca-Conc. K-ConC. U - 1 ppb Cd - Limit TVO 5 ppb

Interference Management The CRI Technology Title of sales presentation – Remarks: „Bruker Confidential“ needs to be erased (slide master!) for external use. 12 12

Spectral Interferences in ICP-MS CRI reduce/remove common plasma based interferences Element Isotope Interfering ion Calcium 40Ca 40Ar+ Vanadium 51V 16O35Cl+ Chromium 52Cr 40Ar12C+ Iron 56Fe 40Ar16O+ Arsenic 75As 40Ar35Cl+ Selenium 78Se 40Ar38Ar+ 80Se 40Ar40Ar+

CRI – Collision Reaction Interface Operates on the plasma, NOT the ion beam Uses similar chemistry to collision cells, but under very different conditions of temperature and pressure

CRI Simple and Effective Simple collision and reaction gases (He and H2) are injected into the plasma as it passes through the cones… Interferences are attenuated, allowing lower detection limits and better accuracy for ‘difficult’ elements. e.g. As, Se, V, Cr, Ca, Fe, etc.

New and Improved CRI II Universal Mode CRI in ‘All He mode’ for all elements Faster and simpler methodology Caters to future USEPA 200.8 requirements Nitrox 500 for online addition of N2 -improves As & Se detection limits Multi-mode Using optimal CRI conditions for more complex matrices (H2, He) Clinical, semi-conductor, geochemical, etc…

Fe-analysis in Ca-matrix with CRI - H2 CaO (and ArO) interference on Fe

Bruker Quantum, ICP-MS Software Integrated LC-ICP-MS Integratede LA-ICP-MS

Aerosol dilution Minimizes sample preparation by extending matrix tolerance of ICP-MS For samples containing 0.2 to 4% Total Dissolved Solids Eg. seawater contains ~3.5% TDS Inline dilution via detuning of nebulizer efficiency & sheath gas dilution effect Achieve 10-fold dilution without additional sample prep Suitable for seawater, metals and mining, high TDS effluents

Auto-optimization of Aerosol Dilution Two dilution settings Low dilution 5-fold dilution Samples with ~1-2% TDS Metals and mining, effluents High dilution 10-fold dilution Samples with ~2-4% TDS Seawater 5-fold reduction in oxide interferences Rare Earths 20.04.2017

Typical Analysis Settings 0.1-0.3 L/min 0.8-1.1 L/min More efficient nebulization Low gas dilution

Aerosol Dilution Settings 0.8-1.1 L/min 0.1-0.3 L/min Less efficient nebulization High gas dilution Followed by automatic optimization of ion optic settings 20.04.2017

Seawater Analysis using Aerosol Dilution 20.04.2017

New! Nitrox 500 Gas Accessory Add N2 or O2 online to auxiliary gas 0-500 mL/min, computer controlled N2 for improved sensitivity and reduced interferences on As & Se 3-4 times sensitivity improvement lower DL’s for enviro applications O2 for organic solvents petrochemical applications

Summary Unmatched Sensitivity All-digital Detection System High efficiency ion mirror Excellent detection limits Attractive to laser ablation and niche application markets Only detector to offer 109 working range in pulse-counting (digital) mode. No cross-calibration of digital-analog modes required Simplified Interference Management Low Maintenance Design Innovative Collision-Reaction Interface (CRI) Removes interferences at plasma interface, not the ion beam Simplified setup and maintenance Hollow ion mirror design requires no cleaning No need for additional cleaning / replace of interference management technology 20.04.2017 25 25

www.bruker.com This is the last slide 20.04.2017 For research use only. Not for use in diagnostic procedures.