Searching for a nEDM at PSI

Slides:



Advertisements
Similar presentations
Mesure du moment électrique dipolaire du neutron Oscar Naviliat-Cuncic LPC-Caen et Université de Caen Basse-Normandie Institut de Physique Nucléaire d'Orsay.
Advertisements

Andreas Knecht1ZH Doktorandenseminar 2009, 4. – 5. Juni 2009 A Gravitational Spectrometer for Ultracold Neutrons Andreas Knecht Paul Scherrer Institut.
K. Kirch Search for the EDM at low ? Motivation Frozen spin technique High and low A compact storage ring experiment?
Multi Pixel Photon Counters (MPPC) and Scintillating Fibers (Sci-Fi)
High voltage test system update Summary of 2005 results Results from March, May 2006 Possible remaining R&D projects Polished electrodes, clean(er) LHe.
Another Route to CP Violation Beyond the SM – Particle Dipole Moments Dave Wark Imperial/RAL WIN05 Delphi June 10, 2005.
Philip Harris University of Sussex (for the EDM Collaboration) The Neutron EDM Experiments at the ILL.
Controls Review  Want to record a full configuration of the experiment at every possible “event”, including controls data.  Event trigger = accelerator.
The cryogenic neutron EDM experiment at ILL and the result of the room temperature experiment James Karamath University of Sussex.
Lepton Moments 2014 Craigville 07/22/2014 P. Schmidt-Wellenburg PSI Searching for the electric dipole moment of the neutron.
Study of the Time-Reversal Violation with neutrons
P. Schmidt-Wellenburg Time and Matter, Montenegro, 06. Oct Slide 1 Improved search for the neutron electric dipole moment Philipp Schmidt –Wellenburg.
UCN optics, polarization foils and spinflipper for the munich nEDM approach Thorsten Lauer.
PEPPo Weekly Meeting February 23, 2011 PEPPo Electromagnetic Calorimeter First measurements Jean-Sébastien Réal, Eric Voutier Laboratoire de Physique Subatomique.
Electric Dipole Moment of Neutron and Neutrinos
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
NEUTRON EDM Philip Harris, on behalf of the CryoEDM collaboration: Rutherford Appleton Laboratory University of Oxford University of Sussex ILL University.
AGS Polarized Proton Development toward Run-9 Oct. 3, 2008 Haixin Huang.
UCN-nEDM DAQ DAQ and Slow Control L.Lee 1 July 3, 2013.
Villigen, Status of the nEDM measurement Progress 2011 PSI Proposal R–05–03.1 Philipp Schmidt-Wellenburg on behalf of the nEDM collaboration.
Magnetic/Electric Fields for KEK-RCNP EDM Experiment K. Matsuta(Osaka), Y. Masuda(KEK), Y. Watanabe(KEK), S.C. Jeong(KEK), K. Hatanaka(RCNP), R. Matsumiya.
Michelle Espy SQUID NMR Signal Outline Overview of SQUIDs in EDM: present thinking - experimental design ideas - expected signal,
Motivation Polarized 3 He gas target Solenoid design and test 3 He feasibility test Summary and outlook Johannes Gutenberg-Universit ä t Mainz Institut.
Ultrahigh precision observation of nuclear spin precession and application to EDM measurement T. Inoue, T. Furukawa, H. Hayashi, M. Tsuchiya, T. Nanao,
The nEDM experiment at PSI 1 Guillaume Pignol (LPSC Grenoble) IN2P3 scientific council, 24/10/2013.
ER01/JA01, th Session of the JINR Scientific Council Dubna, March 27, 2006 Participation of JINR scientists in joint experiments at Paul Scherrer.
Low-frequency nuclear spin maser and search for atomic EDM of 129 Xe A. Yoshimi RIKEN SPIN /10/11-16 Trieste, ITALY Collaborator : K. Asahi (Professor,
PeTeR: a hardware simulator for LISA PF TM-GRS system 23/05/ th LISA Symposium May 2012, BnF Paris L. Marconi and R. Stanga Università degli.
Mitglied der Helmholtz-Gemeinschaft July 2015 | Hans Ströher (Forschungszentrum Jülich) EPS Conference on High Energy Physics, July 2015, Vienna.
 Lori Rebenitsch University of Winnipeg June 17,
UCN magnetic storage and neutron lifetime V.F.Ezhov Petersburg Nuclear Physics Institute, Gatchina, Russia. (ITEP )
2007/11/02nEDM BOSTON1 Dressing Field Study Pinghan Chu University of Illinois at Urbana-Champaign nEDM Collaboration Boston Dressed.
Plots from RCNP UCN Run (April 20-25, 2010). EDM Set-up Schematic H0H0 (RF) H 1 Spin Flipper RF Coil Spherical Coil Cell Valve EDM Cell Magnetized Foil.
DOE 2/11/05 #1 EDM R&D Progress Steve Lamoreaux, Los Alamos Co-spokesperson for the EDM Project for presentation to The Department of Energy Cost & Schedule.
CryoEDM – A Cryogenic Neutron-EDM Experiment Collaboration: Sussex University, RAL, ILL, Kure University, Oxford University Hans Kraus … but before: some.
, Providence RI Paul Scherrer Institut Philipp Schmidt-Wellenburg on behalf of the nEDM collaboration An improved search of the nEDM.
The search for an electric dipole moment of the neutron at PSI Jochen Krempel ETH Zürich 1Jochen Krempel FFK Budapest On behalf of the nEDM collaboration.
First Experiments with the Polarized Internal Gas Target (PIT) at ANKE/COSY Ralf Engels for the ANKE-Collaboration Institut für Kernphysik, Forschungszentrum.
PIN current degradation Versus 3 MeV proton fluence 3 MeV proton (a)(b) (c)(d) Study of radiation damage in VCSELs and PINs for the optical links of the.
Electric dipole moment searches E.A. Hinds Birmingham 11 th July 2011 Centre for Cold Matter Imperial College London.
The Polarized Internal Target at ANKE: First Results Kirill Grigoryev Institut für Kernphysik, Forschungszentrum Jülich PhD student from Petersburg Nuclear.
FrontierScience G.P.1 MATRIX an innovative Pixel Ionization Chamber for Online Monitoring of Hadrontherapy Treatments Giuseppe Pittà.
The cryogenic neutron EDM experiment at ILL Technical challenges and solutions James Karamath University of Sussex.
Collaboration Meeting Feb. 9 th / 10 th 2004 How may go to Oase for dinner? Register ONLY at MEG web page, not at PSI guesthouse! Register early enough,
First results from CMD-3 detector at VEPP-2000 collider Budker Institute of Nuclear Physics, SB RAS, Novosibirsk, Russia September 2011 E.Solodov (for.
Mesure du moment électrique dipolaire du neutron Oscar Naviliat-Cuncic LPC-Caen et Université de Caen Basse-Normandie Journée de la division Champs et.
Assembly 12/14/06 #1 Assembly and Commissioning Paul Huffman.
Neutron and electron EDMs PPAP meeting, Birmingham, 18 th September 2012 Mike Tarbutt Centre for Cold Matter, Imperial College London.
Environment of the nEDM experiment at PSI Jochen Krempel Institute for Particle Physics ETH Zürich , Ascona1.
Mitglied der Helmholtz-Gemeinschaft Development of 3D Polarimeters for storage ring EDM searches JEDI Collaboration | David Chiladze (IKP, Forschungszentrum.
Florian Piegsa – nnbar at ESS – June 13 th Florian Piegsa ETH Zürich – Institute for Particle Physics Magnetometry – nnbar at ESS.
INSTITUT MAX VON LAUE - PAUL LANGEVIN Measurement of parity-violating asymmetries in the reactions of light nuclei with polarized neutrons ( 6.
Yannis K. Semertzidis Brookhaven National Laboratory New opportunities at CERN CERN, 12 May 2009 Storage Ring EDM Experiments The storage ring method can.
DEVELOPMENT OF PIXELLATED SEMICONDUCTOR DETECTORS FOR NEUTRON DETECTION Prof. Christer Fröjdh Mid Sweden University.
– + + – Search for the μEDM using a compact storage ring A. Adelmann 1, K. Kirch 1, C.J.G. Onderwater 2, T. Schietinger 1, A. Streun 1 1 Paul Scherrer.
Neutron Imaging and Tomography with MCPs
Development of a new compact 5.8 GHz ECR ion source at LPSC
Neutron and electron electric dipole moments
The status of the search for a nEDM and the new UCN sources
Using ultracold neutrons to constrain the neutron electric dipole moment Tamas Budner.
SNS Injection Fields and Coils
A new simultaneous spin analyser (USSA) for the PSI nEDM experiment
Sensitivity of Hybrid Resistive Plate Chambers to Low-Energy Neutrons
Accelerator R&D and Particle Physics at PSI
“Electron cooling device in the project NESR (FAIR)"
I Alexander Nass for the JEDI collaboration
(On Behalf of CMS Muon Group)
electric dipole moments (EDM)
Gain measurements of Chromium GEM foils
A DLC μRWELL with 2-D Readout
Presentation transcript:

Searching for a nEDM at PSI P. Schmidt-Wellenburg on behalf of the PSI-nEDM collaboration

The collaboration 6 countries 14 institutions 45 members

See talk by B. Lauss UCN source at PSI nEDM UCN Source Proton Accelerator 590 MeV Cyclotron 2.2 mA beam current See talk by B. Lauss nEDM UCN Source 2 experimental areas / 3 beamlines

Outline The apparatus Ongoing measurements and results UCN - performance Magnetometers and field control High voltage and leakage currents Ideas for the next generation experiment

Apparatus overview This is a sketch of the apparatus. In the center you see both high voltage electrodes and the insulator ring. This makes up the precession volume for the neutrons. The upper electrode can be charge up to high voltage whereas the lower stays grounded. The entire setup is within an aluminum vacuum chamber. The main magnetic field coil, a cosine theta coil is wound onto the vacuum tank producing a field of 1muT. Further more whe have a total of 33 shrim coils to adjust and fine tune the field within the precession chamber. The vacuum tank is surrounded by four layers of Mu-Metal with to reduces the earth magnetic field. The neutrons coming from the source are polarised in a 5T superconducting magnet, than pass through a slit to be filled into the chamber. After the cycle the are detected inside a neutron detector. The spin analysis is done sequentially just above the detector. We use to types of magnetometers to monitor the field. Mercury gas is used to estimate the field within the chamber, Dominique Rebreyend will present this in his talk. Cesium magnetometers are used to measure the field locally around the main precession chamber. And can thus also be used as gradiometers.

The apparatus 2009 Transfer from ILL (France) to PSI (Switzerland) Setup in thermally stabilized wooden house Two independent air-conditionings Six coils for surrounding field compensation (SFC)

Outline The apparatus Ongoing measurements and results UCN - performance Magnetometers and field control High voltage and leakage currents Ideas for the next generation experiment

UCN operation Empty Filling Monitor Just before Christmas we got ready for UCN. The UCN source story has already been told today, thus I will only add a small supplement. We prepared the apparatus for UCN, the SC magnet was flown in and installed at the end of the UCN source guide. we installed our own Nickel molybdenum coated glass guides, and the switch. In a rapid test at the BOA beam line here at PSI we could show, that the detector can digest high count rates. We identified the neutron signal and learned to discriminated it from the background. The detector was then finally mounted below our apparatus. A. Serebrov et al., NIMA 545(2005)490

UCN detector 6Li doped glass scintillator stack 3H  6Li 6Li depleted 6Li enriched 110 µm 60 µm Time (ns) Signal (mV) 6Li doped glass scintillator stack 9 independent channels (PMTs +DAQ) High count rate capable > 10 M We use a 6Li based scintillator in combination with a PMT that has been developed by the collaboration. It consist of 9 individual channels to accept high rates. UCN are captured in the Li enriched region of the scintillator and the decay products of the reaction n+6Li -> 3H + He produce a signal in the PMT. The reason for the stacked scintillators allow to collect all decay products. However, two stacks have been applied upside down as one can see in the signal to background separation. 30/11/2011 Integration gate: 9 –200 ns Channel 1 & 9 scintillator upside down Channel 8 has noise G. Ban et al., NIMA 611 (2009) 280

UCN Detector Monitor mode ~70000 UCN Emptying ~30000 UCN High UCN losses High depolarization rate G. Ban et al., NIMA 611 (2009) 280

UCN emptying curve During emptying: high loss rate of stored spin component → wrong polarisation τflip = 236 s τloss =16.5 s τ↓ = 163 s τ↑ = 16.9 s N = 29185 α0 = 0.999 Best fit to data

UCN storage time We measured the storage time for neutrons in our system, as this directly influences our sensitivity (On the one hand a longer free precession time is preferable, on the other hand the number of neutrons counted decays with time du to slits, up scattering and neutron decay) Two exponentials are fitted to accommodate for the fact, that the neutron spectrum softens with time. The result was expected for setup and combination of materials.

UCN Spin performance Rough adjustment of trim coils UCN detection spin sequence not yet optimized

Ramsey curve taken with 250 s precession time UCN Ramsey cycles Ramsey curve taken with 250 s precession time

Sensitivity E=110/12 kV/cm N10=9838 N20=8042 T1=56.6 s T2=182.5 s α0=0.79 Tα=556.6 s Minimum: σ(219s)=5.94×10-24 e·cm → σ(1d)=4×10-25 e·cm Assuming 30 x more UCN

Outline The apparatus Ongoing measurements and results UCN - performance Magnetometers and field control High voltage and leakage currents Ideas for the next generation experiment

The measurement technique Measure the difference of precession frequencies in parallel/anti-parallel fields: For the main part of my talk I would like to concentrate on this little term there. Which makes life difficult when changing from parallel to anti parallel field configuration. RAL-Sussex-ILL: dn < 2.9 x 10–26 e cm C.A.Baker et al., PRL 97 (2006) 131801 for dn<10-26 ω < 60 nHz

Magnetic shield Four layer Mu-Metal Shielding factors: x: 12000, y: 3000, z:8000

Surrounding field compensation Surrounding field (~ 80μT) Compensation and stabilization Three coil pairs: 6m x 8m, d= 4m 9/18 windings Six current supplies (10/20 A) Ten 3-axis Fluxgates (FG)

Sensor positions Z Monitoring positions close to shield (~ 0.3…0.8 m) nEDM Coordinate system FG 9 FG 8 FG 3 FG 6 FG 1 Al frame Y FG 5 FG 7 Thermo house (first floor) Magnetic shield door FG 0 FG 2 X 21

Results Feedback with inverted & regularized Matrix Twelve sensors close to shield taken into account (for x-direction shown below: sensors 0x, 3x, 6x, and 8x are used)

Systematic effects Most important source of systematic effects →Field mapping →Online Cs-OPM measurement →Dedicated B-drift runs (ramping E-field) →Magnetic scanning at PTB, Berlin × 10-27

Hg co-magnetometer See talk by D. Rebreyend

Principle of Cs magnetometer

Monitoring of vertical magnetic gradients Cesium magnetometers Monitoring of vertical magnetic gradients Two cesium magnetometer arrays Stabilized laser PID phase locked DAQ ±140kV 1 2 3 4 5 … 11 12 I have already told you that we used cesium magnetometer for mapping. The original reason was to have a insitu magnetic field gradiometer made of an array above the high voltage electrode and one array below the bottom ground electrode. This year we have setup a power stabilized laser. It provides the laser light to both cesium magnetometer arrays by a fiber beam splitter. The cesium are read out and driven by a dedicated data acquisition system. At the moment 9 are mounted further will be added this spring.

Homogenizer and fiber bundle Fiber bundle Beam splitter mounted on the enclosure support 31 vacuum feedthroughs for optical fibers

Adjusting field gradients Measure the response of all n=17 magnetometers to changes of each m=33 individual coil current 10nT Known response allows to calculate ideal currents for given field setting (iterative process) 10pT

Gradients STD from six gradiometer pairs

Uncompensated field drift Magnetization through changing polarity Coming now back to the table I have showed you in the beginning. One systematic effect is directly correlated with the change of the polarity of the electric field. It is called uncompensated field drift and is thought to be produced by a magnetization of something by charging currents. It is called uncompensated, as most of this changed field would be compensated by the change of the co magnetometer, however a gradient would not. One can estimate the effect to be 1.8 time 10-27 e cm per fT/cm of field gradient change.

Uncompensated field drift +100 E [kV] 100 s time -100 For this purpose we have frequently ramped the electric field from +100 to minus 100 kV measuring at the same time the magnetic field with cesium magnetometers. This was done as HV did not work with cesium at vacuum. Ramping speed = 1 kV/s Charging current = 35 nA

Uncompensated field drift No effect is observed at the level of 2.8 fT/cm Translates into What I show you here is a preliminary result of this autumns test run. You see for two cesium combinations that all data scatters around zero gradient. In fact, no effect was observed on the level of 2.8 fT/cm which translates into a systematic effect of 2.5 time 10 to the minus 27 e cm. No effect is observed at the level of 2.8 fT/cm Dedicated runs (daytime)

Outline The apparatus Ongoing measurements and results UCN - performance Magnetometers and field control High voltage and leakage currents Ideas for the next generation experiment

High voltage Cesium work with HV HV did not work with Cs Tests HV works up to 200kV Flashovers along fiber bundles Reliable HV runs at ±150kV 3 Leakage current @ 195 kV 2 Another crucial piece of the apparatus is the high voltage system. During investigations concerning the performance of the HV cesium we found out that the cesium do fine in high voltage whereas we can’t ramp the high voltage in vacuum. We started detailed investigations taking out everything and showing, that we can operate the old apparatus up to 200kV, however, 195kV if we want leakage currents across the chamber below 1nA. The we put back in the parts we need for measuring a magnetic field. The fiber bundles from the cesium provoked flashovers already at 100 kV, taking them apart in single fibers improved things dramatically. Another problem might be the polarizing optics in the gap between high voltage and ground. However, the system does not always give very clear answers. nA 1 15:06 15:14

Testing high voltage Configuration w bundle -110 kV vacuum 145 kV He/Ne Configuration wo bundle 198 kV He/Ne 200 kV He/Ne

Leakage current Leakage currents are caused by the high voltage and appear along the surface of the insulator ring. Changing the polarity of the high voltage will change the direction of the leakage current, and hence the magnetic field produced by these currents Most contribution of the leakage currents cancel out, not so jφ. jr jφ jφ jr jz jφ A leakage current of 1 nA produces a false edm of 2 × 10 -28 e cm

Leakage current measurement 3.5600 FEMTO 3.5595 3.5590 3.5585 Current (nA) 3.5580 3.5575 3.5570 -80 -60 -40 -20 20 40 60 80 -0.9 -0.6 -0.3 0.0 0.3 0.6 0.9 ILeak (nA) UHV (kV) ILeak ≤ 0.5 nA σ ≤ 0.1 × 10-27e cm 0.75pA 3.5565 4 pA 3.5560 3.5555 2 4 6 8 10 Time (h) Monitoring of leakage currents on ground electrode Combination of protection circuit and highly sensitive current/voltage amplifier

Outline The apparatus Ongoing measurements and results UCN - performance Magnetometers High voltage and leakage currents Ideas for the next generation experiment

3He see talk by A. Kraft n2EDM: General concept Simultaneous measurement in 2 precession chambers Laser based Hg co-magnetometer 3He magnetometers Multiple Cs magnetometers for 3He readout and gradients UCN chamber position at PSI UCN beam height E 3He see talk by A. Kraft

Thermohouse2 10×6×8 m3 EMC shield made of copper Thermally stabilized

Conclusion & Outlook Apparatus is ready for data taking Presently remeasuring UCN parameters High quality adjustment of B-field gradients Excellent performance of high voltage nEDM data taking from Nov 2012 400 nights of data in 2013/2014 → σ < 5×10-27 e·cm In parallel design of next generation experiment → σ < 5×10-28 e·cm

The Neutron EDM Collaboration Physikalisch Technische Bundesanstalt, Berlin Laboratoire de Physique Corpusculaire, Caen Institute of Physics, Jagiellonian University, Cracow Henryk Niedwodniczanski Inst. Of Nucl. Physics, Cracow Joint Institute of Nuclear Reasearch, Dubna Département de physique, Université de Fribourg, Fribourg Laboratoire de Physique Subatomique et de Cosmologie, Grenoble Biomagnetisches Zentrum, Jena Katholieke Universiteit, Leuven Centre de Spectrométrie Nucléaire et de Spectrométrie de Masse, Orsay Inst. für Kernchemie, Johannes-Gutenberg-Universität, Mainz Inst. für Physik, Johannes-Gutenberg-Universität, Mainz Paul Scherrer Institut, Villigen Eidgenössische Technische Hochschule, Zürich M. Burghoff, A. Schnabel, J. Vogt G. Ban, V. Helaine1, Th. Lefort, Y. Lemiere, O. Naviliat-Cuncic, G. Quéméner K. Bodek, G. Wyszynski3, J. Zejma A. Kozela N. Khomutov Z. Grujic, M. Kasprzak, P. Knowles, H.C. Koch4, A. Weis G. Pignol, D. Rebreyend S. Afach, G. Lembke N. Severijns, P. Pataguppi S. Roccia C. Plonka-Spehr, J. Zenner1 W. Heil, A. Kraft G. Bison, Z. Chowdhuri, M. Daum, M. Fertl3 , B. Franke3, B. Lauss, A. Mtchedlishvili, D. Ries3, PSW, G. Zsigmond K. Kirch1, J. Krempel, F. Piegsa I would like to thank you all for your interest and all these colleagues for their excellent work! Thank you very much. also at: 1Paul Scherrer Institut, 2PNPI Gatchina, 3Eidgenössische Technische Hochschule, 4GUM Mainz