Continuous Insulation for Code-Compliant & High Performance Walls.

Slides:



Advertisements
Similar presentations
University of Minho School of Engineering Territory, Environment and Construction Centre (C-TAC) Uma Escola a Reinventar o Futuro – Semana da Escola de.
Advertisements

BUILDING ENERGY CODES UNIVERSITYwww.energycodes.gov/BECU 1 BUILDING ENERGY CODES UNIVERSITY ANSI/ASHRAE/IES Standard Scope and Application April.
Carpentry Green Application 5. Key Lessons from Carpentry In Carpentry, we learned about: Tool and equipment use, safety, and maintenance Primary materials,
Continuous Insulation for Code- Compliant, High-Performance Walls pima.org.
Building Enclosure Moisture Management Institute (BEMMI)
Fire Requirements For Foam Plastic Insulation and WRBs in Exterior Walls Presented to By Jesse J. Beitel July 31, 2012.
What Is EIFS Exterior Insulation and Finish Systems (EIFS) is a multi-layered exterior wall system that is composed of foam board insulation that.
Designing and Installing Exterior Vapor Distribution Systems INTRODUCTION Course Overview and Objectives.
Emerging Standards and their effect on Exterior Continuous Insulation in Commercial Wall Construction.
Building Enclosure Commissioning (BECx): Practical Project Implementation.
NFPA Chapter 6 Chapter 6 is used to classify the occupancy and the hazard contents Proper classification is used to guide the implementation of.
PRESCRIPTIVE R-VALUES, U-FACTOR EQUIVALENTS, AND TOTAL UA ANALYSIS.
Structural.
Fire.
Note – we are having a title slide and a background slide created – for now, please focus on copy Audience – for now, we are going to assume that the audience.
THE “GREEN” BUILDING MOVEMENT PROPERTY CONSERVATION AND YOU 12 th Annual Texas State Fire Marshals’ Conference October 19, 2010 Austin, Texas.
Building science.
What You Need to Know About EPA’s ENERGY STAR Certified Homes Program Learn more at energystar.gov 1.
Flash and FOIL® Frame Wall Insulation. Module 1 Masonry Wall Insulation Hybrid Spray Foam and Reflective Insulation System – Fi-Foil® Company Introduces…
CONTINUOUS INSULATION PRIMER. PART 1 – Continuous Insulation Definition (ASHRAE 90.1)ASHRAE 90.1 Applications: Roof, Wall, and Foundations.
Northwest Energy Code Compliance with Mass Wall Assemblies
ARCH-432 Vapor Retarders and Air Barriers Attendance In what modern day country was the first cavity wall developed and used? For what purpose? A. Spain.
What You Need to Know About EPA’s ENERGY STAR Certified Homes Program Learn more at energystar.gov 1.
Choosing the Right Siding When selecting siding, there are six basic issues to consider: 1. Water Resistance. Water-resistant types of siding will have.
Objectives Compare locations in North America Potential for moisture problems Different driving forces Analyze potential for moisture problems in cooling.
Part 2: Buildings as a System Lee F. Ball Jr., PhD
Phoenix Convention Center Phoenix, Arizona Air Barrier Technologies Energy TechnologiesWindows and Building Envelope Technologies Diana Hun, PhD Oak Ridge.
Governmental Constraints on Construction Chapter 2.
NOTE – WE ARE HAVING A TITLE SLIDE AND A BACKGROUND SLIDE CREATED – FOR NOW, PLEASE FOCUS ON COPY AUDIENCE – FOR NOW, WE ARE GOING TO ASSUME THAT THE AUDIENCE.
Attending the ICC Conference in Detroit this September or know someone who is?
Energy Curriculum Advanced Transportation Technology and Energy Initiative.
Cladding attachment.
Engineering Analysis of NFPA 285 Tested Assemblies
Installing Appliances and Interior Vapor Distribution Systems MODULE 1 Introduction.
ENERGY CODES INTRO. PART 2 – Energy Code Compliance Two primary sources for requirements plus IRC Chapter 11 for One-/Two-Family Dwellings.
SELECTING INSULATION MATERIALS  Insulation can serve as more than just an energy barrier, providing fire resistance, humidity control, and noise reduction.
Presented By Richard Cook. Tennessee Building and Moisture Analysts, Inc Hardcoat or Synthetic? 2.
An Introduction to the U. S
INSTALLATION DETAILS. Installation Details for Code Compliance Must be installed per manufacturer’s instructions Architects can provide construction details.
AIR BARRIER REQUIREMENTS. Energy Code - Air Barrier Requirements Material air permeability ≤ cfm/ft 2 per ASTM E2178 (IECC 2012 C )IECC.
1 | Building Americaeere.energy.gov Building America Solution Center New Code Compliance Briefs Assist in Resolving Codes and Standards Concerns in Energy.
Sprinkler Loads on Trusses
Fire Resistance Rated Truss Assemblies Educational Overview.
EXPLANATION OF FOOTNOTE H. R2ci ≠ R5ci – “Footnote h” The application of an earlier version of a footnote to the R- value table was stretched beyond its.
 Welcome & introduction  Health & safety  Mobile ‘phones  Agenda.
Precast Concrete Panel Group 6 Alex Cooper Yadir Avila Erjan Kadrakunov.
PRESENTED BY: Al Cobb, Founder, Sips School CHAPTER 9 OF 10 Finish Material and Detailing SPONSORED BY:
Continuous Insulation (ci) & Water Vapor Control Applications of Building Science For Moisture Resistance & Energy Efficiency.
Stretch Code Informational Session March 16, 2011.
Overdriven Nails in Structural Sheathings Overview.
Day 4 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Window Installation: Pan Flashing and Air-Sealing to Prevent Water Intrusion Educational Overview Change title and presenter info to suit purpose. Revised.
Truss Heel Heights and Energy Code Requirements
Use of Resilient Channel or Hat Channel to Meet the Lateral Restraint/Bracing Requirements of the Bottom Chords of MPCWT Floor Systems Overview Revised.
Use of Cantilevered Sill Plates with MPCWT to Align with Varying Thicknesses of Exterior Sheathing Overview Revised 3/22/2017.
Prescriptive R-values, U-factor equivalents, and total ua analysis
Continuous insulation primer
NSA Spring Meeting March 17, 2011 NSA Engineering Services Report.
Educational Overview Revised 6/13/2017
Wood Structures Topic 8 Quality Workmanship
Introduction Basic Requirements for a facade:
MODULE 9 – Building Envelope
Overdriven Nails in Structural Sheathings
Water-Resistive Barriers: Assuring Consistent Assembly Water Penetration Resistance Educational Overview Revised August 31, 2018.
Position Statement on Sealed Truss Placement Diagrams for the 2012 or 2015 International Residential Code Overview Revised 3/23/2017.
Summary and conclusion
Floor Truss Ribbon Board Load Path
Truss Submittal Packages and Jobsite Packages
Above Grade ICF Walls Interim Summary - Details & Water Management Strategies Building Green With Concrete October 22, 2015 Presented by Brian Hubbs, P.
Presentation transcript:

Continuous Insulation for Code-Compliant & High Performance Walls

INTRODUCTION

Introduction Welcome Scope: – Above-Grade Exterior Walls Commercial and Residential Buildings – Foam Plastic Insulating Sheathing (FPIS) Continuous insulation (CI) application – Two audience groups: Builders, installers, inspectors & field sales staff Design professionals and plan reviewers

Outline Three Parts: – PART 1: Continuous Insulation Definition, types, properties, functions, applications – PART 2: Energy Code & CI Wall insulation and air-barrier requirements, code compliance resources, and non-equal substitutes – PART 3: Building Code & CI Fire safety, structure, vapor retarders, water-resistive barrier and code compliance resources

Who is FSC and ACC? The Foam Sheathing Committee (FSC) of the American Chemistry Council focuses on technical research and education to advance the appropriate use of foam sheathing and promote its application in codes, standards, and other resources for the construction industry. Current Regular Members Are: – Atlas Roofing Atlas Roofing – Dow Dow – GAF GAF – Hunter Panels Hunter Panels – Johns Manville Johns Manville – Owens Corning Owens Corning – RMAX RMAX

Execution Like most building products, the benefits of CI depend on proper execution in design and installation. CI needs to be properly integrated with the energy code, building code and components for a complete wall assembly. Fortunately, there are excellent resources to help the user succeed.

OVERVIEW

Why learn about Continuous Insulation? A well-informed market is a successful and sustainable market Designers, builders, code officials, and installers need: – Access to good information to guide decisions in the appropriate use of continuous insulation. – Resources to help comply with code requirements and identify optimal solutions, including: Literature research, testing, analysis and code defined Research ReportsResearch Reports Code compliance Research Reports Installation details Manufacturer instructions Educational programs – To gain experience and confidence to maximize CI’s: Cost-effective use Various benefits and capabilities.

Benefits & Capabilities of CI – Energy Code Compliance: A simple and effective solution to prescriptive R-values in colder climate zones An effective alternative in any climate zone. – Above-Code Performance: More CI = enhanced thermal and moisture control Increasing cavity insulation only to meet energy code can increase risk of moisture condensation, unless other mitigating actions are considered.

Benefits & Capabilities of CI – Resource and Environment Conservation: CI reduces energy consumption and greenhouse gas emissions over the life of the product and building – Economic Payback: Investment in CI is paid back throughout the life of the building with reduced energy use

Benefits & Capabilities of CI – Occupant Comfort: CI can provide a more comfortable interior environment because it isolates the structure and interior from outdoor extremes and helps minimize cold-spots (thermal bridges). – Durability: CI protects structural materials and interior finishes from excessive moisture and temperature extremes, prolonging life expectancy and reducing risk of “call- backs”

Benefits & Capabilities of CI – Multi-Functional: CI can be used as a cost-effective 4-in-1 solution for: 1.Continuous insulation 2.Continuous air-barrier system 3.Water-resistive barrier system 4.Water vapor control layer This 4-in-1 performance of CI is often associated with the concept of a “perfect wall” for high-performance buildings, yet the same principles can be used for minimum code wall assembly. – Some proprietary CI products can provide structural bracing (a 5 th capability)

Execution Like most building products, the benefits of CI depend on proper execution in design and installation. CI needs to be properly integrated with the energy code, building code and components for a complete wall assembly. Fortunately, there are excellent resources to help the user succeed.

OUTLINE

Topical Outline PART 1 – Continuous Insulation Primer – Definition – History of CI – Integrated Role of CI in Building Construction – Energy Conservation and Environmental Value of Continuous Insulation – Types & Properties of CI Materials – Overview of Multiple Functions & Applications of CI – Resources for Code Compliance and Technical Support (tabulation with code references and TER references/links)

Topical Outline PART 1a – Foam Sheathing Applications For All Climate Zones – 1-2 – 3-4 – 5-6 – 7-8

Topical Outline (cont’d) Part 2 – Energy Code Compliance – Importance of Energy Efficiency and CI – Multiple Paths for Compliance – Three Wall Insulation Methods – Wall insulation requirements Prescriptive R-values (IECC-C or ASHRAE 90.1) Prescriptive R-values (IECC-R / IRC Chapter 11) U-factors for alternative insulation strategies – Calculator for U-factor alternatives with CI (pending) Application of whole building UA analysis Energy Rating Index and Performance Path

Topical Outline (cont’d) Part 2 – Energy Code Compliance – Cautions: Ensure accurate calculation of thermal performance Avoid excessive thermal trade-offs in whole building UA analysis Check moisture performance Use CI to control moisture vapor and maximize inward drying potential. Avoid thermal bridging through details that short-circuit continuous insulation

Topical Outline (cont’d) PART 3 – Building Code Compliance – Fire Safety Requirements for CI – Type I-IV buildings » Reference TER No TER No – Type V buildings » Reference TER No TER No NFPA 285 – Type I-IV buildings » Reference TER No

Topical Outline (cont’d) PART 3 – Building Code Compliance – Structural Components Sheathing – Reference code requirements IBC 1403/IRC R703IBC 1403IRC R703 – Reference ANSI/SBCA FS100ANSI/SBCA FS100 Cladding Attachment – Reference code requirements IBC 1609/IRC R IBC 1609IRC R – Reference TER No (attachments)TER No – Reference TER No (details)TER No Window Attachment – Reference code requirements IBC /IRC R612.7IBC IRC R612.7 – Reference TER No TER No

Topical Outline (cont’d) PART 3 – Building Code Compliance – Structural Components Vinyl Siding Wind Pressure Rating – Reference code requirements IBC /IRC R IBC IRC R Foam behind PC Stucco (IBC and IRC R703.2)IBC IRC R703.2 – Explain use of exception to justify foam sheathing behind PC stucco – Reference TER No TER No – Reference TER No TER No

Topical Outline (cont’d) PART 3 – Building Code Compliance – Structural Components Foam behind wood shingles/shakes (IRC R703.5)IRC R703.5 – Mention BC Cedar Shake & Shingle Guide as alternative for single layer furringBC Cedar Shake & Shingle Guide – Refer to use of drainscreen products as alternative to furring – Show FSC case study report with no furring » A couple thoughts to add in here for guidance on to dos? » I think we should do a separate module for the case study » And ask for other case studies particularly if we can find a Canadian case study from BC region. – A single layer of furring is the recommended minimum practice unless the wall is completely shielded from weather – e.g., under porch roof, etc. – A double layer of furring appears most applicable in only the most severe climates (e.g., > 800 mm/yr horizontal rainfall, or on walls in milder climates with limited protection by roof overhangs.

Topical Outline (cont’d) PART 3 – Building Code Compliance – Structural Components Bracing – Reference code requirements (IRC R602 / IBC 2308)IRC R602 IBC 2308 – Reference FSC guide and ICC guide and APA guideFSC guide ICC guide APA guide » Recommendations and guidelines – Many builders are using a building designer or engineer for bracing code compliance.

Topical Outline (cont’d) PART 3 – Building Code Compliance – Structural Components Bracing – Foam sheathing integration

Topical Outline (cont’d) PART 3 – Building Code Compliance – Moisture Control Water resistive barrier (WRB) – Reference code requirements (IBC /IRC R )IBC IRC R703.2 – Reference WRB TER No – Installation detail TER No TER No » Refer to manufacturer’s specific code compliance research report and details » Do not make component substitutions unless specifically permitted by the manufacturer » Be very careful of “or equal” specifications » Routinely inspect and verify installation of flashing and sealing components.

Topical Outline (cont’d) PART 3 – Building Code Compliance – Moisture Control Air-Barrier (just to mention importance of this items to moisture vapor control, even though it is addressed in energy code) For more about Air-Barriers refer to energy code Part 2

Topical Outline (cont’d) PART 3 – Building Code Compliance – Moisture Control Integrated vapor retarder and insulation strategies – Reference code requirements » 2012 IBC /IRC 702.7,IBC IRC » 2010 NBCC Subsections and – Reference ABTG Research Report (pending) – Illustrate determination of acceptable solutions – Coordinate with energy code R-value or U-factor requirements – Recommend that insulation ratios should be considered in CZ 4 or higher any time exterior sheathing and other exterior components have a net perm < 5 perm. – Recommend exterior low perm in moist/humid climates CZ 1 and 2 and CZ 4C (marine) with high perm interior (Class III)

Topical Outline (cont’d) PART 3 – Building Code Compliance – Cautions: Beware of false claims about moisture performance – Ex. EIFS – Ex. Must dry to the exterior Be sure adequate indoor RH control (ventilation in north, dehumidification in south) is provided for any moisture control strategy.