Hershey Academic Support Center Structural Option Shawn Jones Building Analysis of the Hershey Academic Support Center Hershey, PA Shawn Jones Structural.

Slides:



Advertisements
Similar presentations
8621 Georgia Avenue Silver Spring, MD
Advertisements

The Optimus Signature Boutique Offices, India AE Senior Thesis 2013 Punit G. Das | Structural Option Faculty Advisor: Dr. Linda Hanagan.
Reinforced Concrete Design-8
Fraser Centre State College, PA Tyler Strange Structural Option Consultant: Dr. Thomas Boothby April 13, 2011 Tyler StrangeStructural Option Fraser Centre.
Carl Hubben – Structural Option Ae senior thesis Office Building-G EASTERN UNITED STATES.
MICA GATEWAY RESIDENCE BALTIMORE, MARYLAND SCOTT MOLONGOSKI SENIOR THESIS STRUCTURAL OPTION ADVISOR: PROFESSOR SUSTERSIC.
CTC 422 Design of Steel Structures
Jeremiah Ergas AE 482 – 5 th Year Senior Thesis Structural Option April 15 th, 2008 Faculty Consultant: Dr. Ali Memari Northside Piers – Brooklyn, NY Structural.
A Medical Office Building For The Primary Health Network Daniel Goff I Structural Option Dr. Thomas Boothby l Faculty Advisor Sharon, Pennsylvania Source:
Milton S. Hershey Medical Center Biomedical Research Building Joshua Zolko, Structural Option.
Penn State Hershey Medical Center Children’s Hospital Hershey, Pennsylvania Matthew Vandersall Structural Option AE Senior Thesis Dr. Richard Behr.
The University Sciences Building Northeast, USA Final Presentation Chris Dunlay Structural Option Dr. Boothby.
Pennsylvania College Of Technology Dauphin Hall Williamsport, Pennsylvania Aubert Ndjolba Structural Option AE Senior Thesis Thesis Advisor: Dr.
Crocker West Building State College, Pa Eric M. FosterStructural OptionSpring 2009.
3711 Market Street 3711 Market Street Philadelphia, PA Zachary Yarnall l Structural Option AE Senior Thesis l Spring 2010 Faculty Consultant l Professor.
Courtesy of Holbert Apple Associates Georgia Avenue Building Introduction Statistics Gravity System Lateral System Problem Statement & Solution.
LOCKWOOD PLACE BALTIMORE, MARYLAND Monica Steckroth- Structural Option.
George Read Hall The University of Delaware
Rockville Metro Plaza II Rockville Pike John Vais | Structural Option PSU AE Senior Thesis 2014 Faculty Advisor – Dr. Hanagan Rockville, Maryland
Hershey Research Park Building One Jonathan Krepps Structural Option Senior Thesis 2013 Faculty Advisor: Dr. Hanagan.
Kenneth G. Langone Athletic and Recreation Center Kyle Oberdorf Structural Option Thesis April 2007.
Senior Thesis Structural Option Ryan Friis Spring Morgan St. Chicago, IL 111 Morgan St. Chicago, IL Ryan Friis Structural Option.
Nick Szakelyhidi Structural Option Office Building Washington, DC Nick Szakelyhidi Structural Option.
GARY NEWMAN STRUCTURES OPTION ADVISOR: DR. HANAGAN SENIOR THESIS PRESENTATION SPRING 2008.
AMERICAN EAGLE OUTFITTERS Quantum II Corporate Headquarters Michael Sandretto Spring – 2007 Structural Option.
Southeast View of IRMC West View of IRMC. Presentation Outline Introduction Existing Structure Thesis Goals Structural Depth Lighting Breadth Conclusion.
BRYAN DARRIN SENIOR THESIS PRESENTATION MILLENNIUM HALL DREXEL CAMPUS PHILADELPHIA, PA.
Structural System Redesign Existing Conditions Proposal Gravity Design Lateral Design Cost Comparison Schedule Impact Conclusions.
Final Thesis Presentation Washingtonian Center Lee ResslerApril 15, 2008 Faculty Advisor: Dr. Memari.
Duquesne University Forbes Expansion
SEAN BEVILLE STRUCTURAL OPTION ADVISOR: PROF. BOOTHBY APRIL 13, 2009 TEMECULA MEDICAL CENTER “STRUCTURAL SYSTEM OPTIMIZATION” THE DEPARTMENT OF ARCHITECTURAL.
Lancaster, PA Courtyard by Marriott Danielle Shetler - Structural Option Senior Thesis - Spring 2005.
The Towers at the City College of New York Robin Scaramastro - Structural Option - Advisor: Dr. Memari Senior Thesis Final Presentation – Spring 2007.
URS – ARENA DISTRICT OFFICE BUILDING DAVID LEE STRUCTURAL OPTION.
Lexington II at Market Square North, Washington D.C. Alexis Pacella – Structural Option.
Third Avenue NY, New York Michelle L. Mentzer Structural Option.
Howard County General Hospital Patient Tower Addition Columbia, MD Kelly M. Dooley Penn State Architectural Engineering Structural Option.
Whiteland Village Mary Longenecker Structural Option Senior Thesis August 7, 2007.
Ryan Pletz Structural Dr. Hanagan The Pennsylvania State University Department of Architectural Engineering Senior Thesis April 14, 2008.
Welcome to Daniel Painter’s Architectural Engineering Senior Thesis Presentation of Two Freedom Square April 16, 2003 Pennsylvania State University.
Senior Thesis 2006 The Pennsylvania State University
Jonathan Goodroad Structural Option 2005 Thesis Penn State AE Delaware State University Administration and Student Services Building.
Andrew Diehl The Pennsylvania State University Architectural Engineering Department Structural Option 5 th Year Senior Thesis Project “The Comparison of.
Brad Oliver – Structural Option Advisor – Professor Memari.
Oklahoma University Children’s Medical Office Building Oklahoma City, Oklahoma AE Senior Thesis Final Report April 14, 2014 Jonathan Ebersole Structural.
Fordham Place Bronx, NY Aric Heffelfinger Structural Option Spring 2006.
Justin Purcell Structural Option Advisor: Dr. Hanagan.
151 First Side William J. Buchko introduction overview proposal structural depth acoustics breadth cm breadth conclusions 151 First Side Pittsburgh, PA.
Computer Associates International, Regional Office
Park Potomac Office Building “E” Kyle Wagner l Structural Option AE Senior Thesis l Spring 2010 Faculty Consultant l Prof. Kevin Parfitt.
Eastern USA University Academic Center Alexander AltemoseIStructural Option.
James C. Renick School of Education PSU AE Senior Thesis 2006 Mick Leso - Structural North Carolina A&T State University - Greensboro.
Chagrin Highlands Building One Beechwood, Ohio Branden J. Ellenberger - Structural Option Senior Thesis 2004.
Michael A. Troxell Structural Option Senior Thesis 2006 The College of Business Administration Northern Arizona University Flagstaff, Arizona.
Biobehavioral Health Building The Pennsylvania State University Daniel Bodde Structural Option Advisor – Heather Sustersic.
THE NORTHBROOK CORPORATE CENTER Redesign of the Lateral Load Resisting System.
Arlington Gateway Hotel 801 North Glebe Road Arlington, Virginia Michael Gray Penn State University AE Senior Thesis Presentation 2005.
William W. Wilkins Professional Building Columbus, Ohio Michelle Benoit Senior Thesis Presentation Spring 2007 Structural Option.
Albany Medical Center Patient Pavilion Albany, Ny Thomas J. Kleinosky – Structural Senior Thesis 2012 | Advisor: Dr. Hanagan.
Hunter Woron Spring 2012 Structural Professor Parfitt.
CBD Chemical Production Building Virginia, USA Christina DiPaolo │ Structural Option.
Hyatt Regency Pittsburgh International Airport Hiro McNulty Structural Option AE Senior Thesis Spring 2006.
Pearl Condominiums Philadelphia, PA
Advisor: Professor M. Kevin Parfitt
Agricultural Hall and Annex Easting Lansing, MI
Introduction James W. & Frances G. McGlothlin Medical Education Center
FDA CDRH Laboratory Timothy Mueller Senior Thesis, Spring 2006
TOWERS CRESCENT BUILDING B Mike Synnott Structural.
North Shore at Canton The Pennsylvania State University
Mitre III Building McLean VA Debra Schroeder Structural Option.
Presentation transcript:

Hershey Academic Support Center Structural Option Shawn Jones Building Analysis of the Hershey Academic Support Center Hershey, PA Shawn Jones Structural Option Spring 2006 Senior Thesis

Hershey Academic Support Center Structural Option Shawn Jones Presentation Outline »Introduction »Project Proposal »Structural Analysis »Cost Comparison »Fire System Study »Conclusions

Hershey Academic Support Center Structural Option Shawn Jones Introduction

Hershey Academic Support Center Structural Option Shawn Jones Hershey Academic Support Center Hershey Kiss Introduction

Hershey Academic Support Center Structural Option Shawn Jones Building Stats »Owner: Penn State University »Construction Dates: March 1999 – August 2000 »Overall Project Cost: $16,900,000 »Building Size: 150,000 ft 2 »Total Height: 5 stories at 56’-0” with the Mechanical Penthouse at 69’-0” »Project Delivery Method: GMP Introduction

Hershey Academic Support Center Structural Option Shawn Jones Primary Design Team »Architect: WTW Architects »Structural: Whitney, Bailey, Cox, & Magnani, LLP »Construction Manager: Barclay White Skanska »MEP & Lighting: Brinjac, Kambic, & Assoc. »Geotechnical: Schnabel Engineering & Assoc. Introduction

Hershey Academic Support Center Structural Option Shawn Jones Architecture »Precast Concrete Panels »Repeating Window Pattern »Jutting Stairwells on Sides »Membrane Roofing System Introduction

Hershey Academic Support Center Structural Option Shawn Jones Structural System Information »Composite Beam Floor Framing »3” 20-Guage Decking »2.5” Lightweight Concrete Slab »W21x44 & W21x50 Standard Girders »Moment Connections located at columns Introduction

Hershey Academic Support Center Structural Option Shawn Jones Lateral System Information »617 Moment Connections »3 Main Types and 16 Subtypes »Typical Connection: L6 x 4 x 7/8 x 0’7” with 4 Bolts to a Girder and 2 Bolts to a Column »Typical Detail Shown Introduction

Hershey Academic Support Center Structural Option Shawn Jones Project Proposal

Hershey Academic Support Center Structural Option Shawn Jones Problem Statement »At full restraint, the lateral system seemed over designed and removing moment connections would create a significant savings. »Design the lateral system to it’s actual capacity and check the affects on both the lateral system as well as the floor system using “Type 2 with Wind” analysis. »Examine Cost Analysis & the Fire Protection System in detail Project Proposal

Hershey Academic Support Center Structural Option Shawn Jones Solution Method »Find the actual partial fixity of the different moment connections. »Apply to the building and compare results. »Check for floor system effects due to “Type 2 with Wind” design. »Compare connection prices and choose the most efficient connection type. »Examine the current spray-on fireproofing versus a 2 hour fire rated slab. Project Proposal

Hershey Academic Support Center Structural Option Shawn Jones Design Goals »Don’t adversely affect the Architecture both inside and outside. »Do not exceed H/400 in terms of story drift in any moment frame. »Use up to date code values for design and analysis. Project Proposal

Hershey Academic Support Center Structural Option Shawn Jones Design Criteria »The original building code was BOCA 1996 but was changed to ASCE 7-02 »Gravity Loads → Roof Dead Load = 30psf → Penthouse Dead Load = 125psf → Office Dead Load = 70psf → Main Floor Live Load = 100psf »Lateral Loads → Controlling Case: 0.9D +1.6W Project Proposal

Hershey Academic Support Center Structural Option Shawn Jones Structural Analysis

Hershey Academic Support Center Structural Option Shawn Jones Connection Restraint »End Moment vs. Rotation Graph »Curve 1 represents fully flexible »Curve 2 represents partially restrained »Curve 3 represents fully restrained Structural Analysis

Hershey Academic Support Center Structural Option Shawn Jones Connection Checks »Fracture øFuAn = (o.75)*(58ksi)*An = 43.5ksi*(An) »Rupture øFnAw = (0.75)*(0.6)*(70)*Aw = 31.5*Aw »Yield øFyAg = (0.9)*(36ksi)*Ag = 32.4ksi*(Ag) »All 16 Connections Yielded before Frature and Rupture Occurred. Structural Analysis

Hershey Academic Support Center Structural Option Shawn Jones Relative Stiffness ConnectionConnection SizeStiffness (R ki ) MC-1L6 X 4 X 7/8 X 0'-7"101,549 MC-2L6 X 4 X 7/8 X 0'-6"97,589 MC-3 L3-1/2 X 3-1/2 X 5/8 X 0'-6 1/2"79,203 MC-4L6 X 4 X 3/4 X 0'-7"87,551 MC-5L6 X 4 X 3/4 X 0'-8"88,380 MC-6L4 X 4 X 5/8 X 0'-10"79,417 MC-7L6 X 4 X 3/4 X 0'-9"92,323 MC-8 L3-1/2 X 3-1/2 X 1/2 X 0'-6 1/2"68,596 MC-9L3-1/2 X 3-1/2 X 9/16 X 0'-5"68,830 MC-10L3-1/2 X 3-1/2 X 1/2 X 0'-10"73,001 MC-11PL4 X 5/8 X 1'-2"262,300 PL8 X 3/8 X 2'-0241, ,650 ConnectionConnection SizeStiffness (R ki ) MC-12PL7 X 1/2 X 1'-8"248,100 PL12 X 3/8 X 2'-10"212, ,400 MC-13PL8 X 3/8 X 1'-8"236,600 P12 X 5/16 X 2'-8"214, ,300 MC-14PL4 X 3/8 X 1'-6"256,000 L3-1/2 X 3-1/2 X 1/2 X 0'-6 1/2"68, ,298 MC-15PL5 X 3/8 X 1'10"238,700 L3-1/2 X 3-1/2 X 5/8 X 0'-6 1/2"79, ,952 MC-16PL4 X 3/8 X 1'-6"256,000 L3-1/2 X 3-1/2 X 1/2 X 0'-10"73, ,501 Structural Analysis

Hershey Academic Support Center Structural Option Shawn Jones Structural Analysis

Hershey Academic Support Center Structural Option Shawn Jones Structural Analysis Moment ConnectionRestraint Value (R) MC-134% MC-233% MC-327% MC-430% MC-530% MC-627% MC-731% MC-823% MC-923% MC-1025% MC-1185% MC-1278% MC-1376% MC-1455% MC-1554% MC-1656% »Thicker angles allow less rotation »Smaller, stiff plates allow less rotation »Using R ki and the graph, percent restraint was calculated »Typical R values range from 20-90%

Hershey Academic Support Center Structural Option Shawn Jones Story Drift »A 3D SAP2000 Model was used to check story drift »H/400 was considered the acceptable value of drift Structural Analysis Deflection Calculation H/400: ((69’)*(12in/ft))/400 = 2.07in East Section Frame #12: Story Drift = 1.53in < 2.07in ALLOW West Section Frame #2: Story Drift = 1.47in < 2.07in ALLOW Center Section Frame #D: Story Drift = 1.87in < 2.07in ALLOW

Hershey Academic Support Center Structural Option Shawn Jones Story Drift »Removed 2 E-W Roof Moment Connections »Removed all E-W Roof Moment Connections Deflection Calculation H/400: ((69’)*(12in/ft))/400 = 2.07in East Section Frame #12: Story Drift = 1.85in < 2.07in ALLOW West Section Frame #2: Story Drift = 1.76in < 2.07in ALLOW Center Section Frame #D: Story Drift = 2.23in < 2.07in FAIL Structural Analysis Deflection Calculation H/400: ((69’)*(12in/ft))/400 = 2.07in East Section Frame #12: Story Drift = 2.28in < 2.07in FAIL West Section Frame #2: Story Drift = 2.19in < 2.07in FAIL

Hershey Academic Support Center Structural Option Shawn Jones Story Drift »Removed 2 Roof E-W Moment Connections from every other frame »The drift passes and a total of 24 moment connections are removed, valued at about $4000 total Deflection Calculation H/400: ((69’)*(12in/ft))/400 = 2.07in East Section Frame #12: Story Drift = 2.03in < 2.07in ALLOW West Section Frame #2: Story Drift = 1.94in < 2.07in ALLOW Center Section Frame #D: Story Drift = 1.96in < 2.07in ALLOW Structural Analysis

Hershey Academic Support Center Structural Option Shawn Jones Floor System »Floor system uses “Type 2 with Wind” design »Negative wind moment controls lateral member design at columns »Interior beams are controlled by gravity loads »Creates varied floor member sizes »With composite action, shear studs are used to balance out the center positive moment with the negative end moments Structural Analysis

Hershey Academic Support Center Structural Option Shawn Jones »The North-South girders changed from W21x44 with 17 shear studs to W18x40 with 16 shear studs on the first two floors. »40 members in total changed at a savings of $12,320 Floor System »Moment data from SAP2000 was used in conjunction with RAM to check the new member sizes. »There wasn’t a significant change in member size as shown: Structural Analysis

Hershey Academic Support Center Structural Option Shawn Jones Cost Comparison

Hershey Academic Support Center Structural Option Shawn Jones Overview »617 Total Moment Connections, 2,329 bolts, and linear feet of weld »3 Main Types: Top and Bottom Angle, Top and Bottom Plate, and Top Plate with Bottom Angle Cost Comparison

Hershey Academic Support Center Structural Option Shawn Jones Moment Connection Cost »A combination of RS Means and data from Chris Holcombe of Milton Steel was used to price the varying connection types. »The three common connection type prices from Milton Steel are listed in bold along with the rest. Cost Comparison MC-1 = $165 MC-2 = $165 MC-3 = $103 MC-4 = $160 MC-5 = $160 MC-6 = $107 MC-7 = $160 MC-8 = $99 MC-9 = $101 MC-10 = $99 MC-11 = $268 MC-12 = $328 MC-13 = $352 MC-14 = $145 MC-15 = $157 MC-16 = $145

Hershey Academic Support Center Structural Option Shawn Jones Duration Data »Welded connections take about twice as long to erect as bolted connections. »RS Means has output at 105 high strength bolts per day versus 50 linear feet of weld per day. »The average angled connection has 4-6 bolts and the average welded connection has 3-4 linear feet of weld. Cost Comparison

Hershey Academic Support Center Structural Option Shawn Jones Fire System Study

Hershey Academic Support Center Structural Option Shawn Jones Existing System »Designed by the PA Department of Labor and Industry’s Fire and Panic Code for 2 hour fire rating. »Hydraulic sprinkler system with smoke detectors in all major areas »2.5” Lightweight Concrete slab with cementitious spray on fireproofing Fire System Study

Hershey Academic Support Center Structural Option Shawn Jones Proposal »Increase the slab thickness by 1” to meet the 2 hour fire rating for the slab. »Potentially saves cost of spray on fireproofing which covers the slab, beams, and columns. »Fireproofing must remain in the stairwells »RS Means was used to obtain cost data Fire System Study

Hershey Academic Support Center Structural Option Shawn Jones Calculations »Concrete → 30,000 ft 2 area per floor at $91.00 per yd 3 → Assume 10% Waste → Total cost = $50,977 »Fireproofing → 30,000 ft 2 of deck area per floor at $1.29 per ft 3 → 225 columns at 101 ft 2 per floor per column at $1.23 per ft 3 → 620 beams at 156 ft 2 per floor per beam at $0.98 per ft 3 → Deck = $16,925, Columns = $12,102, Beams = $41,227 → Total cost = $70,254 → Total Savings = $19,277 Fire System Study

Hershey Academic Support Center Structural Option Shawn Jones Conclusions

Hershey Academic Support Center Structural Option Shawn Jones Recommendations »Calculating partial fixity of the connections lead to a savings in price of $16,320, but compared to the nearly $17 million dollar project, this savings is minimal. »The time needed to run all the calculations could be better spent saving money elsewhere, so I recommend to use the current flat fixity system. »For connection types, bolted connections are definitely recommended wherever they can be used since welded connections are more expensive and take longer to make. »An extra inch of concrete over spray on fireproofing saves about $20,000, but it does add some weight to the structure, so either system is a plausible choice. Conclusions

Hershey Academic Support Center Structural Option Shawn Jones Acknowledgements »Whitney, Bailey, Cox, & Magnani »WTW Architects »Milton Steel »Dr. Linda Hanagan »The AE Faculty & Staff »Friends and Family Conclusions

Hershey Academic Support Center Structural Option Shawn Jones The End! Questions?