7526A Precision Temperature/Pressure Process Calibrator

Slides:



Advertisements
Similar presentations
1 Series V4T 1/4 DIN Temperature Controllers. 2 3 Watlows Next Generation Styling Series 97 Matching 1/16 DIN Limit Controller Series F4S and F4D Ramping.
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
GS3055-I GSM Universal Wireless Alarm Communicator
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
INTRODUCING The 5502A Fluke’s Newest Multi-Product Calibrator
WELCOME. Controllers Controller 1/32 DIN FKS SMART function for the self-tuning of control parameters. TC, RTD or linear input programmable. Dual Outputs,
9190A Ultra-Cool Field Metrology Well. © 2013 Fluke Corporation Fluke 9190A Ultra-Cool Field Metrology Well A Ultra-Cool Field Metrology Well Product.
Chapter 7 Input Modules.
ProducTVity Station ™ October 2011.
File/ 1 Primary colours Secondary colours Remember to change file name 28pt Ariel bold 18pt Ariel bold l Distributed PID Control and I/O What is.
STARLight PDR 3 Oct ‘01I.1 Miller STARLight Control Module Design Ryan Miller STARLight Electrical Engineer (734)
NeSSI Wireless Sensor / Actuator Networking March 7, 2001 John Crawford VP, Business Development Crossbow Technology, Inc.
G GE Power Management MMII Intelligent MCC Controller.
 A system consisting of a number of remote terminal units (or RTUs) collecting field data connected back to a master station via a communications system.
1. Commissioning of cryogenic crates using Mobile Test Bench 1. The Mobile Test Bench 2. Cryogenics crates and equipment – types of transducers and actuators.
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels.
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Module 3 Eng. Asma Abu Baker. Introduction One of the most important uses of instruments or measuring devices is in the field of process control. If you.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
SCADA and Telemetry Presented By:.
PWS4000 Programmable DC Power Supply Series Choose Your Voltage and Current – Quickly, Precisely Features Featuring:  Linear regulation  Up to 72 V output.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
8000 SERIES INTEGRATED THE INTEGRATED REFERENCE SOLUTION PRECISION DIGITAL MULTIMETERS.
MarsⅡ On-Line UPS Series
Smart transmitters.
1 Chang Shuan Eletronics Co., Ltd
PWC Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview.
® Features and Benefits V3.1. TurboTag ® Features Temperature logger size of credit card Uses RFID reading protocols with EPC product codes More accurate.
CPT2000 Platinum Resistance CED7000 & others Signal calibrators CPT9000 Thermocouple CPT1000 Platinum Resistance Features & Benefits Reference Thermometers.
October 1, 2012 PAX2C Product Launch. 2 © Red Lion Controls Inc. PAX 2 C Universal PID Controller.
8000 Series Options/Technical Overview Series Precision Digital Multimeter New Technology – Multi Processor design No need for AutoCal – High precision.
DMM4020 Digital Multimeter Fact Sheet Measurements with the Push of a Button Features Featuring:  5.5 digit resolution  Basic V dc accuracy of up to.
GS3055-I GSM Universal Wireless Alarm Communicator
Merkmale SITRANS T Automation and Drives Process Instrumentation and Analytics Common Technical Data (1) Technical Data (2) Features Block Diagram Housings.
Codan 5700 Series C-Band Transceiver Technical Overview.
8000 Series Options/Technical Overview Series Precision Digital Multimeter New Technology – Multi Processor design No need for AutoCal – High precision.
Welcome to Product Workshop 2008!. The Indication Group Panel Meters Large Displays Sensors Temperature Controllers Signal Conditioners.
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
Digital Temperature Switches The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
EPack relaunch. Schneider Electric 2 -Industrial – Eurotherm – 16/12/2015 ●1. Reduce your equipment costs.
CUE – Make Any Pump an E-Pump
CEA DSM Irfu SIS LDISC 18/04/2012 Paul Lotrus 1 Control Command Overview GBAR Collaboration Meeting Paul Lotrus CEA/DSM/Irfu/SIS.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
April 24, 2015 FlexBus TM and FlexCards TM. 2 © Red Lion Controls Inc. FlexBus What is FlexBus?  A parallel bus that expands the option card capability.
PCAR Precision In Practice 1 Precision In Practice Achieving the best results with precision Digital Multimeter measurements Paul Roberts Fluke Precision.
© 2013 Fluke Corporation A Super-DAQ Precision Temperature Scanner KRISS MEASUREMENT CLUB November 14, 2013 FLUKE CALIBRATION JAEHEE JANG Public.
USER GUIDE TEMPERATURE CONTROLLER TR-2006 Hot runner temperature controller ShenZhen TanRex Electronic Co.ltd.
Workshop 2013 Indication. 2 © Red Lion Controls Inc.  PAX2 Series Update  Expanding Our Range Indication Goals.
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview.
Pressure Measurement and Calibration for Process Instrumentation
Process Control Loop and Calibration Basics. Learning objectives ● Develop an understanding of calibration and why it’s important ● Review the related.
Lesson 1 PLC BASICS. PLC Definition  Programmable Logic Controllers are industrial computers that control machine and other applications.  PLC have.
2500 Series® Compact System Components
PLC Terminology and Application
ProtoDUNE SP – Slow control temperature readout setup test
SCADA for Remote Industrial Plant
Disc Thickness Measurement System
GROUND-FAULT GROUND-CHECK MONITOR
FEEDER PROTECTION UNIT
SIO-RTD RTD MODULE.
Instructor Resources.
INSTRUMENTASI INDUSTRI
MicroLogix Packaged Controllers
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
724 Temperature Calibrator
Instructor Resources.
Presentation transcript:

7526A Precision Temperature/Pressure Process Calibrator

Introducing the 7526A Precision Process Calibrator Value proposition Typical applications Key features & benefits Product overview Product features Summary specs Options & accessories A “best fit” for process instrumentation calibration

7526A Value Proposition Balances precision and versatility with cost The 7526A is less expensive than high-end multi-product calibrators, yet more precise and versatile than handheld field calibrators Calibrates wide ranging workload 7526A The 7526A meets the needs of labs that cannot fund higher priced instruments while providing the precision required to get the job done More precise than handheld process calibrators Less expensive than high-end multi-product calibrators like the Fluke 5080 ($13k) Poor man’s calibrator Versatility, precision & value The 7526A offers an isolated measurement channel allowing it to precisely, and simultaneously, source and measure temperature & electrical parameters. Pressure measurement can be viewed in both displays in different units of measure.

Typical Applications Industry Applications Calibration workload Pharmaceutical/ Bio-tech Monitor temp/pressure process, monitor freezers/ovens/incubators, freeze-drying, SIP Temp/pressure transmitter, pressure gauges, handheld calibrator, temp readout, chart recorder Food Monitor process temp, food dryers, monitor cold storage, monitor refrigeration equipment, SIP Temp/pressure transmitter, temp readout, limit alarm, PID controller Oil & Gas Monitor pipeline provers, custody transfer Temp/pressure transmitter, pressure gauges, flow transmitter Chemicals Monitor temp/pressure reaction conditions, refrigeration, boilers Temp/pressure transmitter, limit alarms, pressure gauges Electronic Equipment Manufacturer Manufacturing electronic devices Automatic test station 3rd Party Calibration Lab Service industries listed above All of the above Same customers that would purchase the 914X Benchtop rather than field

7526A Key Features & Benefits Improved thermocouple accuracy Can calibrate Documenting Process Calibrators (2:1 TUR) and nearly all handheld temperature & pressure calibrators Switch test (unique to 7526A) Increased workload. Not every temperature source, such as a drywell, includes a switch-hold function. Pressure sources do not. Simultaneous source and measure Calibrate more DUTs in less time. See results of an adjustment immediately. MET/CAL® Calibration Software compatible Write automated procedures, create reports. Value Costs less than a DPC, highly versatile, precise but competitively priced.

7526A Product Overview Precision Temperature/Pressure Process Calibrator Sources and measures: Thermocouples (13 types) RTDs (9 types) Thermistors (YSI-400) Voltage (0 to 100 Vdc) Resistance (0 Ω to 4 kΩ) Current (100 mA output / 50 mA input) Measure only: Pressure (0 to 700 bar / 10,000 psi) Used to calibrate temp/pressure transmitters Transmitters primarily used in process industries such as pharma, bio-tech, food, chem, petrol, etc. Sources and measures TC, RTD, voltage, resistance, current Measures pressure when combined with a pressure module or transmitter

7526A Product Overview (Left Half) DC voltage output terminals 0 Vdc to 100 Vdc Accuracy: 30 ppm (+3 μV) DC current output terminals 0 mA to 100 mA Accuracy: 50 ppm RTD/Ω output terminals (two-wire) 5 Ω to 4 kΩ, Accuracy: ± 0.05 ºC, –200 to 630 ºC Terminal binding posts are made of a special copper alloy to decrease thermal EMFs. Discreet wires or standard banana plugs can be used. The HI/LO pairs are distanced for standard dual banana plugs Four-wire RTD/Ω input terminals Accuracy: ±0.02 ºC Pt 385, 100 Ω, –80 to 100 ºC Isolated pressure module input Accepts Fluke 700 & 525A series pressure modules Thermocouple input/output terminal Accuracy: ± 0.1 ºC –100 to 800 ºC (type K)

7526A Product Overview (Right Half) Isolated input controls dc voltage/current Switch test mode 24 Vdc power supply 250 Ω HART resistor Pressure input mode Numeric and secondary function keys Cursor controls Input/Output Function Keys dc voltage/current TC/RTD Pressure mode Unit type Stby/Operate Isolated input terminals Allows simultaneous source and measure dc voltage (0 to 100 V) dc current measurement (0 to 50 mA) Switch-test input 24 V dc loop power supply

7526A Product Overview (Rear Panel) Power line voltage selector and fuse compartment Power switch 1) Serial to USB adapter cable included as std RS-232 Port GPIB IEEE-488 Service port Chassis ground AC power inlet 120/240 AC

7526A Product Features STBY/OPR In Standby mode, changes to the output value are not applied until you select the Operate mode In Operate mode, each change to the output value is applied immediately Voltages more than 30 V are not applied. The mode automatically reverts to Standby for safety In Thermocouple mode, move through the thermocouple types (including millivolts) In RTD/Ohms mode, move through the RTD types (including ohms) In Pressure mode, move through the pressure units 1) STBY/OPR is a safety feature that prevents unwanted application of source voltage Select a secondary function from the numeric keypad

7526A Product Features HART Enables a 250 Ω internal resistor Without the loop resistance in place, the DC power supply would “short out” the communicator’s AC voltage signal The presence of a loop resistor in the circuit prevents the DC power supply from “loading” the AC voltage signal by the communicator. Some minimum loop impedance is needed so that the HART signal can be ‘seen’ or ‘read’ by a HART master, like a HART communicator or HART modem. ∿ ∿↓ ↓ HART transmitter HART communicator 250 < R < 1100 Power supply Computer “HART” is an acronym for Highway Addressable Remote Transducer. Superimposes digital communication signals [frequency shift keying (FSK)] on top of the 4-20mA signal; does not interfere with the analog signal. Enables two-way field communication to take place. Additional information beyond the normal process variable (P.V.) is communicated to/from a smart field instrument. LOOP PWR Turns on an internal 24 Vdc power supply in series with the current measurement circuit Used to power 4 – 20 mA transmitters

7526A Product Features RTD and Ohms Measure/Source Measures & Sources all common RTD types Stores CVD coefficients for up to five RTDs Stores coefficients for one SPRT (ITS-90) Resistance from 0 Ω to 4 kΩ. RTD types: Pt 385 100 Ω, 200 Ω, 500 Ω, 1000 Ω Pt 3926 100 Ω Pt 3916 (JIS) 100 Ω Ni120 120 Ω Cu 427 (Minco) 10 Ω YSI 400 thermistor 1) Stores CVD coefficients for five unique RTDs

7526A Product Features Thermocouple (TC) Measure/Source Measure & sources all common thermocouple types and basic millivolts from -10.0 to 75.0 mV Thermocouple types: B, C, E, J, K, L, N, R, S, T, U, XK, BP Pressure Measure The isolated pressure display uses the same physical pressure connector as the primary display Both displays can show pressure at the same time The same source can be shown in different pressure units Can display pressure source in two different UoM

7526A Pressure Modules

7526A Product Features Preset setpoints Nine preset output setpoints can be stored and recalled for each of these output modes: Voltage Current Each thermocouple type (including mV) Each RTD type (includes each of the five custom curves) Switch Test Mode When in Switch Test mode the Calibrator can sense a contact transition (closed or opened) At the time of the transition, the Calibrator records the value and units shown on the primary display 1) Switch test can test limit alarm switches

7526A Product Features Remote Interface RS-232 or GPIB (IEEE-488) can control 7526A from a PC A serial to USB adapter cable is included as standard with the 7526A Individual commands can be typed into terminal emulator software MET/CAL compatible – write automated procedures and generate calibration reports 1) FSC (function select code) – describes instrument functions so that the instrument can be called out in Met/Cal procedures

7526A Workload Two-wire transmitters, calibrators, Pressure to Current converters, transducers, signal conditioners and temperature probes are all examples of the 7526A’s workload.

7526A Summary Specs

7526A Summary Specs (cont.)

Convert Spec in PPM to % Reading Convert a spec in ppm to % error of reading

7526A Standard & Optional Equipment Included in the box: 7526A Precision Process Calibrator Users Manual CD-ROM Getting Started AC Mains Cord Thermocouple Shorting Jumper NIST Traceable Calibration Report USB to Serial Adapter Cable Options and accessories: 5520A-525A Leads kit Y7526A Rack Mount kit Fluke 700 and 525A-P series pressure modules MET/CAL with 7526A Function Select Code (FSC) MET/CAL 7526A calibration procedure Optional accredited calibration

Questions ?

Appendix – P/I Transmitter 1) Display pressure in the left display, measure current loop in the right display

Appendix – I/P Transmitter

Appendix – V/I Transmitter

Appendix – RTD Transmitter

Appendix – TC Transmitter

Appendix – RTD Indicator

Appendix – Temperature Switch Test 1) 914X w/out process electronics

Appendix – Pressure Switch Test 1) Hand pump pressure source, switch test