CLAS12 Pre-shower S. Stepanyan (JLAB) Collaborating institutions: YerPhI, JMU, OU, NSU, W&M, Orsay-IPN, JLAB Project overview CLAS12 TWG meeting, February.

Slides:



Advertisements
Similar presentations
HCAL-J Status Hadron Calorimeter HCAL-J SBS Collaboration Meeting July, 2014 G. B. Franklin Carnegie Mellon University 7/8/2014 Carnegie Mellon INFN, Catania.
Advertisements

SoLID EC Design for IHEP 2012/10. Basic Features of Preliminary Design Based on COMPASS Shashlyk module design. 0.5mm lead/0.12mm air gap/1.5mm scintillator/0.12mm.
CMS Outer Hadron Calorimeter (HO) Project Naba K Mondal Tata Institute, Mumbai, India.
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
1 Prototyping Megaton-Scale  Detectors Jason Trevor DOE Review July 25, 2007 Developing a New Lower-Cost Scintillator Design.
CPR2 Optical Cables Joey Huston Michigan State University …taking optical signals from edge of CPR/crack detectors to PMT boxes mounted on back of wedges.
The Design of MINER  A Howard Budd University of Rochester August, 2004.
Status of CLAS12 PCAL project
CLAS12 Pre-shower Calorimeter (PCAL) project Fall of 2010 to fall of 2014, a lot of person-hours S. Stepanyan (JLAB) Hall-B Meeting, March 24, 2014.
NuMI Schematic View of the MINOS Scintillator System 8 m Scintillator Module WLS Fibers Optical Connector Clear Fiber Ribbon Cable (2-6 m) Multiplex Box.
Status of EIC Calorimeter R&D at BNL EIC Detector R&D Committee Meeting January 13, 2014 S.Boose, J.Haggerty, E.Kistenev, E,Mannel, S.Stoll, C.Woody PHENIX.
K1.8 meeting Report from E05 group Toshiyuki Gogami 26 Dec 2014.
Study of response uniformity of LHCb ECAL Mikhail Prokudin, ITEP.
SoLID EC Update Zhiwen Zhao 2012/05/22. Beam test update Coverage for PVDIS Road map.
Shashlik type calorimeter for SHIP experiment
CALICE Meeting DESY ITEP&MEPhI status report on tile production and R&D activities Michael Danilov ITEP.
Beam test of scintillator strips Miho NISHIYAMA Shinshu University ・ scintillator strip calorimeter ・ Kuraray scintillator strips and KNU extruded ・ the.
Status of Projectile Spectator Detector A.Kurepin (Institute for Nuclear Research, Moscow) I. Introduction to PSD. II. Conception and design. III. Development.
Oct C. Smith - PCAL/EC Commissioning 1 PCAL/EC Commissioning Document
Thomas Jefferson National Accelerator Facility Page 1 EC / PCAL ENERGY CALIBRATION Cole Smith UVA PCAL EC Outline Why 2 calorimeters? Requirements Using.
Study of Sampling Fractions Shin-Shan Yu, A P, Hans Wenzel, October 18, 2006.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
Future Beam Test Plans of the GLD Calorimeter Aug 学術創成会議 Satoru Uozumi (Shinshu) for the GLD calorimeter group We are planning to have two beam.
Electromagnetic Calorimeter for the CLAS12 Forward Detector S. Stepanyan (JLAB) Collaborating institutions: Yerevan Physics Institute (Armenia) James Madison.
Julien Bettane, Giulia Hull, Silvia Niccolai, Daria Sokhan 31/1/2012 Status and commissioning plan for the Central Neutron Detector.
T. Sugitate / Hiroshima / PHX031 / Nov.01 The Photon Spectrometer for RHIC and beyond PbWO 4 Crystal Density 8.29 g/cm 3 Radiation length 0.89 cm Moliere.
Hadron Calorimeter HCAL-J GEp Electron Calorimeter BigCal Hadron Calorimeter 1 G. Franklin, Carnegie Mellon University 10/13/2011.
Forward Muon Installation and Commissioning Dmitri Denisov Fermilab Director’s review 7/12/1999 Plan Forward muon detectors Mini-drift tubes installation.
The Electromagnetic Calorimeter – 2005 Operation J. Sowinski for the Collaboration and the Builders Indiana Univ. Michigan State Univ. ANL MIT BNL Penn.
The NA62 rare kaon decay experiment Photon Veto System Vito Palladino for NA62 Coll.
HE CALORIMETER DETECTOR UPGRADE R&D Y. Onel for University of Iowa Fairfield University University of Mississippi.
VVS Prototype Construction at Fermilab Erik Ramberg 26 February,2002 Design issues for VVS Details of VVS prototype design Schedule and Budget Testing.
CLAS12 forward detector: Pre-shower S. Stepanyan (JLAB) Collaborating institutions: YerPhI, JMU, OU, NSU, Orsay-IPN Concept, R&D, PED … CLAS12 Detector.
SCECAL progress report Tohru Takeshita (Shinshu) _DESY Beam Test summary _improvements for FNAL BT _FNAL module _current status at Fermilab.
DESY Beam Test of a EM Calorimeter Prototype with Extruded Scintillator Strips DongHee Kim Kyungpook National University Daegu, South Korea.
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
Magnetized hadronic calorimeter and muon veto for the K +   +  experiment L. DiLella, May 25, 2004 Purpose:  Provide pion – muon separation (muon veto)
MAMUD Magnetized hadronic calorimeter and muon veto for the K +   +  experiment L. DiLella, March 29, 2005 Purpose:  Provide pion – muon separation.
SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower CBM Meeting ITEP
LC Muon Detector Development Overview Hardware R&D Goals Hardware Configuration Design Issues Procurement, Engineering, Manpower Additional Development.
Performance of Shower Maximum Detectors Saori Itoh (Shinshu Univ.) GLC calorimeter group (KEK,Kobe,Konan,Niigata,Shinshu,Tsukuba) Introduction Detector.
Abstract Beam Test of a Large-area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger,
ScECAL Beam FNAL Short summary & Introduction to analysis S. Uozumi Nov ScECAL meeting.
Coordinate Detector: prototype design General idea about the Coordinate Detector (CDET) so far: Three independent vertical planes with 15 cm plastic shield.
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
DESY Beam Test of a EM Calorimeter Prototype with Extruded Strip Scintillator DongHee Kim Kyungpook National University Daegu, South Korea.
06 FEB th ACFA Development of fine strip scintillator with extrusion technique SungHyun Chang, DongHee Kim, Jun Suhk Suh, Youngdo Oh, Daejung Kong,
SiD Muon Detector Progress. Overall concept 2 There are slots in the iron. We will insert modules of orthogonal strips of appropriate size into the slots.
LHCf Detectors Sampling Calorimeter W 44 r.l, 1.6λ I Scintilator x 16 Layers Position Detector Scifi x 4 (Arm#1) Scilicon Tracker x 4(Arm#2) Detector size.
Working group on photon vetoes Meeting on June 7 th : 1.Status of Geant4 simulations 2.Discussion on LAV structure 3.Discussion on readout 4.News on Spaghetti.
FT Prototype Test Purpose: test the prototype of the FT Calorimeter and Scintillator Hodoscope Technique: prototype is installed under the Hall B photon.
CLAS12 Pre-shower H. Voskanyan (YerPhI)  R&D: Test measurements  Prototype CLAS Collaboration, CLAS12 TWG Meeting February 28, 2007, JLAB.
Performance of Scintillator-Strip Electromagnetic Calorimeter for the ILC experiment Satoru Uozumi (Kobe University) for the CALICE collaboration Mar 12.
P. Checchia LCWS02 Jeju1 Lccal * : an R&D project for the Electromagnetic barrel Calorimeter Design principles Prototype description Status of.
Scintillator and Fiber Test Measurements with Gluing Clas12 upgrade pcal user group May 13, 2009 Clas12 upgrade pcal user group May 13, 2009 Dustin Keller.
FORWARD ATLAS {major contributions from Per Grafstrom (CERN), Michael Rijssenbeek (Stonybrook), Brian Cox (Manchester} Andrew Brandt Luminosity measurement.
A.PasseriHigh granularity Pb-SciFi calorimeter1 Construction and tests of a fine granularity lead-scintillating fibers calorimeter P.Branchini, F.Ceradini,
Simulation and reconstruction of CLAS12 Electromagnetic Calorimeter in GSIM12 S. Stepanyan (JLAB), N. Dashyan (YerPhI) CLAS12 Detector workshop, February.
Future Beam Test Plans of the Calorimeter Group Aug 学術創成会議 Satoru Uozumi (Shinshu) for the GLD calorimeter group We are planning to have two beam.
SuperB meeting, Frascati
IHEP group Shashlyk activity towards TDR
WLS FIBER-SCINTILLATOR GLUING UPDATE
PCAL Cosmic Ray Tests Progress Report C. Smith μ U V W MODULE 2
Electromagnetic Calorimeter for the CLAS12 Forward Detector
CLAS12 Forward Detector Element PCAL
SCINTILLATOR HARDWARE
Study of a Scintillating Digital Hadron Calorimeter Prototype
LC Muon Detector Development Overview
Presentation transcript:

CLAS12 Pre-shower S. Stepanyan (JLAB) Collaborating institutions: YerPhI, JMU, OU, NSU, W&M, Orsay-IPN, JLAB Project overview CLAS12 TWG meeting, February 21, 2008, JLAB

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB PCAL+EC simulations (15 layers and 108 strips) Energy resolution for electrons thrown in the center of the of the calorimeter Efficiency of two photon reconstruction from high energy  0 ’  decays Electromagnetic shower reconstruction at high energies

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB CLAS12 PCAL project [WBS ] CLAS12 detector Proposed configuration for the pre-shower:  lead and scintillator sandwich with three stereo readout views, UVW (5 layers per readout view)  fine segmentation of scintillator layers in the forward region for all three UVW views  light transport from scintillator to PMT via green wave- shifting fibers embedded in grooves on the surface of the scintillator strips Does not require high performance, high transparent scintillators. Low cost extruded scintillators can be used. No optical contact inside the box. Pre-shower calorimeter

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB Outcome of R&D efforts Choice for the scintillator, WLS fiber, and PMT Fermi Lab extruded scintillators, 4.5x1 cm 2 with 3 grooves Kuraray, 1mm diameter Y11 single clad HAMAMATSU R6095 selected with 500 nm Design parameters of the pre-shower are established 15 layers of the lead and scintillator, 2.2mm lead, 10mm scintillator 4.5 cm segmentation of the scintillator layers in forward region Final price tag for the construction of 6 modules of PCAL is set Expected photo-electron yield ~11p.e./MeV for 3 fibers (yield for EC readout from the test measurements was ~8.4p.e./MeV)

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB PCAL Construction Construction of the PCAL consists of several quasi-independent processes:  processing of scintillators and gluing of fibers (W&M)  assembly of PMTs and dividers (JMU)  stacking of scintillator-lead layers (JLAB)  mounting PMTs and testing (JLAB)  storage of ready modules before moving to the Hall B (JLAB) Each process requires independent man power and work space Most of these processes require clean environment, climate controlled areas Few details of construction must be worked out before construction starts:  type of glue to use  gluing procedure and QC  fiber channeling during the stacking  polishing of fiber ends on after assemble  PMT dividers – active vs. passive

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB Construction time line and manpower

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB Plans for R&D in FY08 Must - 1.Continue testing of different optical glues - will require about $1000 to purchase glues, work will be done either at JMU 2.Testing of different voltage dividers for PMTs - will require about $2000 for a design and assembly of the dividers, work will be done at JLAB? 3.Continue testing new scintillators from FNAL - will require about $2000 to order fibers. Work will be done at JLAB 4.Develop scintillator cutting technology – will require test samples. Work will be done at JLAB/W&M 5.Continue tests of the small prototype (using beam) - Work will be done at JLAB Overall the estimate ~$7000 for purchases and money for a visitor for 6 months. Should 1.Continue die development with FNAL, requires about $ Disassemble and reassemble the small prototype with new (latest) FNAL scintillators. Work will be done at JLAB. Will require some machine shop time, stock room items, electronic lab time, etc., about $1000

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB PCAL PED Most of critical details are worked out! JJ Robertson

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB PCAL design issues PMTs along sides of modules from adjacent sectors are very close to each other. On the top of modules, where the distance is largest, the gap is only ~15mm wide. This will lead to a)Difficulties during the installation - requires positioning of individual modules with better than few mm accuracy b)Could result in damaging of fiber enclosures, if measured dimensions on forward carriage will change due to the load change c)Makes maintenance of modules (replacing PMTs) very hard, some spots may become inaccessible

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB Solution to the tight space for PCAL PMTs Change the read out of the W-view to be from the same side where V-view readout is located (at the back side of a module). It will create a second row of PMTs on the V-side. There will be no interference to any detector or structure, that part is wide open. Possible impact of moving W-view readout will be some what larger non-uniformity of energy sampling at the trigger level, if the trigger for CLAS12 EC&PCAL will be the same as it is done for EC. Simulations are needed in order to estimate the magnitude of the impact. However, use of fADCs (as planned for CLAS12 DAQ) eliminates the issue with trigger non- uniformity. Slice of a sector

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB PCAL design issues (cont.) 2.Current design assumes equal number of PMTs for each U, V, and W-views (64 PMTs per view, total of 192 PMTs per module). This requires double tower readout with single PMT at large angles. Having U-view with finer segmentation farther to large angles might be beneficial for overall detector performance. Simulations are needed to test different configurations of the readout segmentation. 3.There are few solutions for the top and bottom plates (composite plates, foam with SS skins mounted in a SS or Aluminum frame). For the final choice more FEA and tests are needed.

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB Other issues For construction:  type of glue to use  gluing procedure and QC  fiber channeling during the stacking  polishing of fiber ends on after assemble  PMT dividers – active vs. passive Reconstruction software issues: fADC – pulse width and energy resolution

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB Summary  Pre-shower R&D and PED are in progress  Main design parameters are established using the full GEANT simulations, but there are still few issues to resolve before the design is completed  Key components of the PCAL (scintillator-fiber-PMT) are selected, but there are few details for construction to be worked out  Cost estimate for the whole project is completed  MRI proposal for amount of $780K ($630K) is submitted to NSF – total of 60% of whole PCAL procurement  Contingency and risk analysis are performed  Stages and required resources for construction of the main detector are identified

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB Surface mount vs. through hole mount 3 grooves with 1 mm diameter single clad Y11, 4.5 cm wide scintillator 1 through hole with 1.5 mm diameter single clad Y11, 4 cm wide scintillator Fibers were glued with BC600 optical cement Test PMT Trigger PMT-D Trigger PMT-T Test Setup ADC Gate A la Minos Minarva strip

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB Test PMT ADC distributions 3-fibers, 1 mm in diameter1 fiber, 1.5 mm in diameter Single photoelectron peak of test PMT Pedestal is at 341  has ~25% less light per unit of width than current PCAL design  1.5 mm diameter fibers are ~2.5 times more expensive than 1mm fibers  will require ~10% more readout channels  broken fiber will have much bigger effect  may be easy to assemble 4 cm wide scintillator with 1 through hole for a single 1.5 mm diameter fiber

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB Current activities Prototyping  a small scale prototype, rectangular 5x5 matrix (XXY), total of 15 layers  absolute light yield and time characteristics (MIP)  shower reconstruction (energy, position) and time characteristics (in the beam) Data taking is in progress in EEL (see Mikhail’s presentation). Simulation of the prototype in GEANT and cluster reconstruction are in progress (N. Dashyan and D. Keller) After cosmic tests are completed (this week) Prototype will be moved to the Hall for tests with electrons on the Hall B pair spectrometer. Testing of different optical glues started at JMU (see Kevin’s presentation)

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB ADC signals for 10 MeV energy deposition (M. Yurov) For each PMT, a MIP’s peak position, at given HV, was determined using two Gaussian fit to the ADC distribution.

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB Gain Curve based on MIP data (M. Yourov) In order to have approximately 10ADCch/MeV, measurements with different HV settings have been performed.

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB Full scale prototype (not necessary to have all PMTs and readout electronics)  workout design details (fiber routes, PMT holders, light guides …)  techniques for the fiber gluing and the quality control  work out details of the assembly procedure  establish a technique for fiber-adapter-PMT assembly  attenuation and light yield measurements (MIP)

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB PCAL PMT locations relative to EC

S. Stepanyan, CLAS12 TWG meeting, February 21, 2008, JLAB R&D FY06 & FY07 Goals:  establish optimal design parameters of the pre-shower  determine characteristics of electromagnetic shower and  0 ’  reconstruction in the CLAS12 forward electromagnetic calorimeter  determination of the light read out configuration  selection of final components  test measurements and prototyping GEANT implementation and simulation of the pre-shower N. Dashyan (YerPhI), K. Whitlow (SULI) CLAS-NOTE & CLAS-NOTE Test readout system, component selection and protyping G. Asryan, H. Voskanyan CLAS-NOTE H. Viskanyan, M. Yurov, D. McNulty CLAS-NOTE 2007?