TECHNIQUES IN MOLECULAR BIOLOGY

Slides:



Advertisements
Similar presentations
Electrophoresis Theory
Advertisements

Hydrodynamic Techniques
Protein Purification Molecular weight Charge Solubility Affinity.
Gel electrophoresis Ashti Mohammad Amin M.Sc. Molecular Biology Medical Research Center Hawler Medical University
Lab. 3 Gel Electrophoresis
GEL ELECTROPHORESIS Lab.5. Gel electrophoresis is a method used to separate nanoparticles by charge or size. It is used to: 1. separate a mixed population.
1 Lecture 4: Physical characterization of Viruses Different techniques used to study viruses: Agarose gel electrophoresis Polyacrylamide gel electrophoresis.
Gel Electrophoresis Gel electrophoresis is a method that separates macromolecules, either nucleic acids or protein. Electrophoresis describes the migration.
Sedementation When particles are forced through a solution, they experience resistance to movement which depends on properties of the particle such as.
Protein Purification and Expression MCB 130L, Lecture 2.
Electrophoretic techniques. Introduction: _The term electrophoresis describe the migration of a charged particle under the influence of an electric field.
Chapter 3-Contd. Western blotting & SDS-PAGE
Quality Control of Product
Agarose gel electrophoresis BCH 333 [practical]. Agarose gel electrophoresis: is a method of gel electrophoresis used in biochemistry and molecular biology.
Protein Electrophoresis BIT 230. Electrophoresis Separate proteins based on Size (Molecular Weight - MW) SDS PAGE Isoelectric Point Isoelectric focusing.
SDS-Polyacrylamide Gel Electrophoresis
Polyacrylamide Gel Electrophoresis
Gel Electrophoresis Do you want a footer?.
Chemistry 4010 Lab It’s all about PROTEINS… It’s all about PROTEINS…
Qualitative Analysis of Product
18.7 Isolation, Purification, and Fractionation of Proteins (1)
Chapter Five Protein Purification and Characterization Techniques
Electrophoresis PAGE Dr Gihan Gawish.
Lab.8 8RBs0Ghg_48
5. SEPARATION AND DETECTION OF PROTEINS II SDS-PAGE Jana Vobořilová, Anna Kotrbová-Kozak, Vlasta Fürstová, Tereza Kopská.
Western Blotting.
Electrophoresis Ayat Zawawi.
In 1949, a team led by chemist Linus Pauling placed hemoglobin solutions from people with a disabling form of anemia and from healthy volunteers in an.
Dr Gihan Gawish 1. Hydrodynamic methods  Common experimental manipulations in biochemistry  centrifugation, dialysis and filtration are strongly influenced.
Cell fractionation and centrifugation
Gel electrophoresis.
Electrophoresis Defined as the migration of charged particles through a solution under the influence of an electric field. Many important biological molecules.
Agarose (Horizontal) Gel Electrophoresis Malasian word for seaweed is “agar-agar”. Agarose is derived from red seaweed. Electrophoresis means “carrying.
Separation of main plasma protein by using SDS-PAGE
Proteomics The science of proteomics Applications of proteomics Proteomic methods a. protein purification b. protein sequencing c. mass spectrometry.
Sedimentaion.
Gel Electrophoresis.
PROTEIN TECHNOLOGY By DR ZARINA ZAKARIA. Why to exploit protein Information about protein structure has led to a deeper understanding of the evolutionary.
ANALYTICAL CHEMISTRY CHEM 3811 CHAPTER 23 DR. AUGUSTINE OFORI AGYEMAN Assistant professor of chemistry Department of natural sciences Clayton state university.
Javad Jamshidi Fasa University of Medical Sciences, December 2015 Tools and Techniques for Studying Cells.
Separation techniques ?. Molecules can be separated: Chemically: by charge, by action with specific reagents Physically: by solubility, by molecular weight,
SDS-PAGE Ms. Nadia Amara.
Sodium Dodecyl Sulfate-PolyacrylAmide gel Electrophoresis [SDS-PAGE] Experiment 7 BCH 333[practical]
Semester 2 Final Review Part 1 Genetics, Biotechnology, Protein Synthesis and Evolution.
General Tests for Chemistry 101
Polyacrylamide Gel Electrophoresis. Electrophoresis Horizontal Agarose Gels Agarose forms a gel or molecular sieve that supports the movement of small.
Lab Session 9 IUG, 2012 TMZ.
Biotechnology. Gel Electrophoresis A technique that separates macromolecules on the basis of their rate of movement through a gel under the influence.
Analytical Approaches in Cell Biology BSCI 420 Sept 12, 2002 “Make everything as simple as possible, but not simpler” -Albert Einstein 1. Separation of.
Analytical biochemistry lab KAU-biochemistry dep. L. Nouf Alshareef
By-pooja kamble m.Sc-i. UNIT I:MICROTOMY,MICROSCOPY,CENTRI FUGATION 1.3-PRINCIPALS AND APPLICATIONS OF CENTRIFUGATION.
Gel Electrophoresis + restriction enzymes Lecturer: Bahiya Osrah.
Principles of chromatography
Tymoczko • Berg • Stryer © 2015 W. H. Freeman and Company
Bioseparation I Centrifugation. What is Bioseparation?  Purification or separation of a specific material of interest from contaminants in a manner that.
Quality Control of Product
ELECTROPHORETIC METHODS
Gel Electrophoresis.
Agarose Gel Electrophoresis
Using Gel Electrophoresis to Study Molecules
Agarose gel electrophoresis
Amino Acids, Peptides, and Proteins
By Zainab sajjad (117114) Ayesha Rehman (117115)
Lecture 2   ELECTROPHORESIS Electrophoresis is a separation technique that is based on the mobility of the ions in an electric field.. it is a Greek word.
Biotechnology.
# A mechanical method of seperating immiscible
Agarose gel electrophoresis
Hydrodynamic Techniques
INTRODUCTION TO ELECTROPHORESIS
DNA Agarose Gel Electrophoresis
Presentation transcript:

TECHNIQUES IN MOLECULAR BIOLOGY CENTRIFUGATION- Separation of molecules/macromolecules/organelles according to the size, shape, density & gradient ELECTROPHORESIS- Separation of molecules/macromolecules according to charge MICROSCOPY- Structural examination of minute molecule/macromolecule/organelle

CENTRIFUGATION http://ntri.tamuk.edu/centrifuge/centrifugation.html MATERIALS OR PARTICLES IN A SOLUTION CAN BE SEPARATED BY A CENTRIFUGE THAT USES THE PRINCIPLE OF CENTRIFUGATION CLASSES: -ANALYTICAL/PREPARATIVE -ULTRACENTRIFUGATION AND LOW SPEED -DIFFERENTIAL/ZONAL CENTRIFUGATION http://ntri.tamuk.edu/centrifuge/centrifugation.html

ANALYTICAL CENTRIFUGATION IS USED TO MEASURE THE SEDIMENTED PARTICLE PHYSICAL CHARACTERISTICS SUCH AS SEDIMENTATION COEFFICIENT AND MOLECULAR WEIGHT

PREPARATIVE CENTRIFUGATION TO SEPARATE SPECIFIC PARTICLES THAT IS REUSABLE TYPES: - RATE ZONAL - DIFFERENTIAL - ISOPYCNIC CENTRIFUGATION

ULTRACENTRIFUGATION AND LOW SPEED DEPENDS ON SPEED ULTRACENTRIFUGATION - THE SPEED EXCEEDS 20,000 RPM SUPER SPEED ULTRACENTRIFUGATION- THE SPEED IS BETWEEN 10,000 RPM-20,000 RPM LOW SPEED CENTRIFUGATION- THE SPEED IS BELOW 10,000 RPM

DIFFERENTIAL CENTRIFUGATION PARTICLES IN SAMPLE WILL SEPARATE INTO SUPERNATANT AND PELLET OR IN BOTH DEPENDING ON THEIR SIZE, SHAPE, DENSITY AND CENTRIFUGATION CONDITION THE PELLET CONTAINS ALL THE SEDIMENTED COMPONENT MIXTURE AND CAN CONTAIN MATERIALS THAT WAS NOT SEDIMENTED EARLIER

DIFFERENTIAL CENTRIFUGATION SUPERNATANT CONTAINS MATERIALS THAT ARE NOT SEDIMENTED BUT CAN BE SEDIMENTED WHEN CENTRIFUGATION IS DONE AT A HIGHER SPEED

DIFFERENTIAL CENTRIFUGATION

ZONAL CENTRIFUGATION SAMPLE IS APPLIED ON TOP OF SUCROSE OR CESIUM CLORIDE SOLUTION PARTICLE CAN BE SEPARATED ACCORDING TO SIZE & SHAPE (TIME-RATE ZONE) OR DENSITY (ISOPYCNIC)

RATE-ZONAL CENTRIFUGATION

ISOPYCNIC-ZONAL CENTRIFUGATION

SEDIMENTATION COEFFICIENT WHEN CELL COMPONENTS ARE CENTRIFUFED THROUGH A GRADIENT SOLUTION, THEY WILL SEPARATE INTO THEIR OWN ZONE OR LINE/LAYER THE RATE WHEN THE COMPONENT SEPARATES IS CALLED AS SEDIMENTATION COEFFICIENT OR THE s VALUE (SVEDBERG UNIT ) 1 S = 1 X 10-13 SECONDS

SEDIMENTATION COEFFICIENT VALUES PARTICLE OR SEDIMENTATION MOLECULE COEFFICIENT LYSOSOME 9400S TOBACCO MOSAIC VIRUS 198S RIBOSOME 80S RIBOSOMAL RNA MOLECULE 28S tRNA MOLECULE 4S HEMOGLOBIN MOLECULE 4.5S

SPEED OF CENTRIFUGATION A PARTICLE THAT IS ROTATING WILL HAVE A PULLING FORCE IN A FORM OF MAGNITUDE TO SPEED FUNCTION AT DEFINED ANGLE (ROTATION SPEED) AND CENTRFUGATION RADIUS (THE DISTANCE BETWEEN THE SAMPLE CONTAINER AND THE ROTOR CENTRE)

SPEED OF CENTRIFUGATION 2 WAYS OF EXPRESSING THE PULLING FORCE: a) RELATIVE CENTRIFUGATIONAL FORCE-RCF (g) b) ROTATION PER MINUTE (rpm)

RELATIVE CENTRIFUGATIONAL FORCE THE PULLING FORCE OF CENTRIFUGATION IS BASED ON OR RELATIVE TO THE STANDARD GRAVITATIONAL FORCE FOR EXAMPLE 500x g MEANS THAT THE PULLING FORCE IS 500 TIMES BIGGER THAN THE STANDARD GRAVITATIONAL FORCE

RELATIVE CENTRIFUGATIONAL FORCE EQUATION R.C.F. = 1.119 x 10 -5 (rpm2) r rpm=rotation per minute r=radius (in cm) UNIT g

ELECTROPHORESIS THE MOVEMENT OF CHARGED PARTICLE IS INFLUENCED BY ELECTRICAL CURRENT ELECTROPHORESIS IS THE METHOD OF SEPARATING MACROMOLECULE SUCH AS NUCLEIC ACID AND PROTEIN ACCORDING TO SIZE, ELECTRICAL CHARGE AND PHYSICAL PROPERTIES SUCH AS DENSITY ETC SEPARATION IS AIDED BY A MATRIX SUCH AS POLIACRYLAMIDE OR AGAROSE

ELECTROPHORESIS PRINCIPLE: SEPARATION OF MACROMOLECULE DEPENDING ON TWO PROPERTIES: WEIGHT AND CHARGE ELECTRICAL CURRENT FROM THE ELECTRODE WILL PUSH THE MOLECULE AND AT THE SAME TIME THE OTHER ELECTRODE WILL PUT IT MOLECULES WILL MOVE ALONG THE PORES THAT ARE FORMED BETWEEN THE INTER-WOVEN MATRIX THAT ACTS LIKE A SIEVE TO SEAPARATE THE MOLECULE ACCORDING TO THEIR SIZE

ELECTROPHORESIS ELECTRICAL CURRENT WILL FORCE THE MACROMOLECULE TO MOVE ALONG THE PORES THE MACROMOLECULE MOVEMENT DEPENDS ON THE ELECTRICAL FIELD FORCE, THE MOLECULE SIZE AND SHAPE, THE SAMPLE RELATIVE HYDROPHOBIC PROPERTY, IONIC STRENGTH AND THE TEMPERATURE OF THE ELECTROPHORESIS BUFFER DYEING WILL AID THE VISUALISATION OF MACROMOLECULE IN THE FORM OF SEPARATED SERIES OF STRIPES

PROTEIN ELECTROPHORESIS PROTEIN HAS A POSITIVE OR NEGATIVE NET CHARGE AS A RESULT OF THE COMBINATION OF CHARGED AMINO ACIDS CONTAINEDIN THEM THE MATRIX THAT IS USUALLY USED FOR PROTEIN SEPARATION IS POLIACRYLAMIDE TWO DIMENSIONAL GEL ELECTROPHORESIS- PROTEIN SEPARATION ACCORDING TO ISOELECTRICAL POINTS AND MOLECULAR WEIGHT

2-D PROTEIN ELECTROPHORESIS FIRST STEP/DIMENSION: PROTEIN SEPARATION ACCORDING TO ISOELECTRIC POINT (PROTEIN CONTAINS DIFFERENT POSITIVE AND NEGATIVE CHARGE RATIO) -ELECTROPHORESIS IS DONE ON THE GEL IN THE FORM OF TUBE; PROTEIN WILL MOVE IN A SOLUTION WITH DIFFERENT pH GRADIENT

2-D PROTEIN ELECTROPHORESIS FIRST STEP/DIMENSION: -PROTEIN WILL STOP WHEN IT REACHES THE pH WHICH IS EQUAL TO ITS ISOELECTRIC POINT i.e WHEN THE PROTEIN DOES NOT HAVE A NET CHARGE. + BASIC - ACIDIC

2-D PROTEIN ELECTROPHORESIS SECOND STEP/DIMENSION: PROTEIN SEPARATION BY MOLECULAR WEIGHT ELECTROPHORESIS IS DONE IN AN ORTHOGONAL DIRECTION FROM THE FIRST STEP; SODIUM DODECYL SULPHATE (SDS) IS ADDED + -

2-D PROTEIN ELECTROPHORESIS

1-D PROTEIN ELECTROPHORESIS PROTEIN IS SEPARATED BY ITS MOLECULAR WEIGHT ONLY THE TECHNIQUE IS ALSO KNOWN AS POLIACRYLAMIDE GEL ELECTROPHORESIS (PAGE) OR SDS-PAGE IF SDS IS PRESENT DURING SAMPLE PREPARATION SIMULATION OF 1-D ELECTROPHORESIS http://www.rit.edu/~pac8612/electro/ Electro_Sim.html

SDS-PAGE TO SEPARATE PROTEIN WITH THE SIZE OF 5 - 2,000 kDa PORES IN BETWEEN THE POLIACRYLAMIDE MATRIX CAN VARIES FROM 3%-30% THE PROTEIN SAMPLE IS IN THE FORM OF PRIMARY STRUCTURE (SAMPLE IS BOILED WITH SDS AND -MERCAPTOETHANOL PRIOR BEING LOADED ONTO GEL)

SDS-PAGE PROTEIN IS STAINED USING COOMASIE BLUE OR SILVER NON-DIRECTIONAL STAINING CAN BE DONE: -ANTIBODY BOUND WITH RADIOISOTOPE OR ENZYME, FLUORESENCE DYE

SDS-PAGE SDS FUNCTION: NEGATIVELY CHARGED DETERGENT THAT BINDS TO THE HYDROPHOBIC REGION OF THE PROTEIN MOLECULE; AS A RESULT THE PROTEIN BECOMES A LONG POLIPEPTIDE CHAIN AND FREE FROM OTHER PROTEINS AND LIPIDS

SDS-PAGE -MERCAPTOETHANOL FUNCTION: TO BREAK DISULPHIDE BONDS SO THAT PROTEIN SUBUNIT CAN BE ANALYSED

NUCLEIC ACID ELECTROPHORESIS AGAROSE OR POLIACRYLAMIDE IS THE MATRIX USUALLY USED TO SEPARATE NUCLEIC ACID IN A TECHNIQUE KNOWN AS AGAROSE GEL ELECTROPHORESIS SAMPLE CONTAINING DNA IS LOADED INTO WELLS LOCATED NEAR TO THE NEGATIVELY CHARGED ELECTRODE DNA THAT IS NEGATIVELY CHARGED WILL BE ATTRACTED TO THE POSITIVE ELECTRODE

NUCLEIC ACID ELECTROPHORESIS DNA WITH A BIGGER SIZE WILL MOVE SLOWER THAN THE SMALLER SIZE WHICH MOVE FASTER STAINING IS DONE USING ETHIDIUM BROMIDE (EtBr) THAT ENABLES THE VISUALISATION OF NUCLEIC ACID; EtBr IS INSERTED BETWEEN THE BASES ON THE NUCLEIC ACID EtBr IS ORANGE IN COLOUR WHEN LIT-UP BY ULTRA-VIOLET LIGHT

NUCLEIC ACID ELECTROPHORESIS

MICROSCOPY ONE OF THE EARLIEST TECHNIQUE TO STUDY MACROMOLECULE PRINCIPLE: TO ENLARGE SMALL IMAGES TYPES OF MICROSCOPY ACCORDING TO THE SIZE OF IMAGE ENLARGEMENT - LIGHT MICROSCOPE (300nm-2mm) - ELECTRON MICROSCOPE (0.15nm-100m)

LIGHT MICROSCOPE IMAGE ENLARGEMENT PRINCIPLE: LIGHT FROM BELOW OF THE MICROCOPE GOES THROUGH THE CONDENSOR TO FOCUS THE LIGHT TO THE SPECIMEN. LIGHT FROM THE SPECIMEN IS RECOLLECTED BY THE OBJECTIVE LENSE TO FORM AN IMAGE

LIGHT MICROSCOPE TYPES OF LIGHT MICROSCOPE : BRIGHT-FIELD MICROSCOPE DARK-FIELD MICROSCOPE PHASE-CONTRAST MICROSCOPE FLUORESENCE MICROSCOPE (UV) (FLUORESCIN/RHODAMIN)

ELECTRON MICROSCOPE PRINCIPLE: -ELECTRON IS USED (NOT LIGHT) TO ENLARGE IMAGE -SPECIMEN MUST UNDERGO A SERIES OF PREPARATION PROCESSES SUCH AS COATING WITH THIN LAYER OF GOLD TO ALLOW EMITTED ELECTRON TO COLLIDE TO AND THEN RECOLLECTED TO FORM IMAGE ON THE SCREEN

ELECTRON MICROSCOPE TYPES: 1) TRANSMISSION ELECTRON MICROSCOPE -ELECTRON GOES THROUGH THE SPECIMEN AND IMAGE IS RECOLLECTED ON A FLUORECENS SCREEN -THE INNER STRUCTURE OF THE SPECIMEN CAN BE SEEN

ELECTRON MICROSCOPE TYPES: 2) SCANNING ELECTRON MICROSCOPE -ELECTRON IS FOCUSSED TO THE SPECIMEN AND THEN REEMITTED (SCANNED) TO THE DETECTOR AND IMAGE IS SEND TO THE SCREEN FOR VIEWING -THE OUTER STRUCTURE CAN BE SEEN

ELECTRON MICROSCOPE SCANNING ELECTRON MICROSCOPE MOSQUITO IMAGES BY SCANNING ELECTRON MICROSCOPE

OTHER TECHNIQUES CHROMATOGRAPHY -PAPER: PROTEIN SEPARATION BY USING FILTER PAPER AS THE MATRIX -ION-EXCHANGE -GEL FILTRATION -AFFINITY -HIGH PRESSURE LIQUID CHROMATOGRAPHY (HPLC)

OTHER TECHNIQUES RADIOISOTOPES FOR MOLECULE TAGGING : 32P, 131I, 35S, 14C, 45Ca, 3H - RIA, ‘PULSE-CHASE’ EXPERIMENT, AUTORADIOGRAPHY ANTIBODY (MONOCLONE/POLYCLONE) FOR TAGGING MOLECULE: EIA, IF, ELISA X-RAY DIFFRACTION ANALYSIS: PROTEIN STRUCTURE DETERMINATION DNA RECOMBINANT TECNOLOGY