Laser Scan detector RLS-3060 Basic information & installation of Laser Scan detector Basic information & installation of Laser Scan detector OPTEX CO., LTD. Nov Training purpose only. Do not duplicate.
Product Overview Laser Scan detector RLS-3060 utilizes ‘Time of Flight’ technology. RLS-3060 does not require any PC for operation. It can be connected to PTZ camera, video transmitter or DVR. RLS-3060 has 4 detection area segments and linked outputs. It can match PTZ control applications. RLS-3060 can recognize the size, speed and distance of objects within the 30M range. Processing with our detection algorithm, it recognize human targets and avoids false alarm factors.
Training purpose only. Do not duplicate. Product Features 30m radius for 190 degrees Vertical and horizontal detection area Unique detection algorithm Four independently adjustable detection areas for PTZ camera control Four independent N.O. outputs Form C master alarm output Automatic area setting function Environmental disqualification circuit Trouble output Tamper output
Training purpose only. Do not duplicate. Why Laser LASER is an acronym for Light Amplification by Stimulated Emission of Radiation Laser is an artificial light that does not exist in nature. It has unique characteristics, that makes it different than “ordinary” light. Monochromatic Laser light is extremely pure and consists of a very narrow spectral range. It enables the separation of emitted light from the detector and other sources. Directional The laser can be collimated and travels over long distances with little spread. It enables the detector to achieve a very high resolution detection area.
Training purpose only. Do not duplicate. What is Laser There are gas lasers, solid-state lasers, liquid lasers and semiconductor lasers. According to medium to make laser light, the wavelength of light is different. A semiconductor laser is small in size and has very low power consumption. X-RayUltraviolet-RayVisible LightMicrowaveTV Wave K (nm ) 400K Infrared GaN(Gallium nitride) 400 nm - Blue-violet laser, in Blu-ray Disc and HD DVD drives AlGalnP 650 nm - DVD drives, Laser pointers AlGaAs 780 nm - Compact Disc Redscan 905 nm - Redscan InGaAsP1310 nm - fiber-optic communication REDSCAN utilize 905nm wavelength Laser (Near Infrared)
Training purpose only. Do not duplicate. What is Laser Why near infrared? Near infrared has a high penetrative characteristic compared to other wavelengths and is invisible. It is preferred for intrusion detection e.g. video surveillance. How affect human health? Redscan’ s laser is Max mW It is classified as Class 1 of Laser Safety Standard. (Complies with 21 CFR and except for deviations pursuant to Laser Notice No. 50 & IEC ) It does not affect human health. Not visible to human eye USA Food and Drug Administration Center for Devices and Radiological Health
Training purpose only. Do not duplicate. Construction of Laser Laser Diode Avalanche Photo Diode TX optic RX optic Scanning mechanism Signal processing Output
Training purpose only. Do not duplicate. Detection principle Scanning mechanism LDADD TX optic RX optic Signal processing Time of Flight (TOF) method By calculating the time during which a emitted beam returns after hitting the object, the distance to the object can be measured. Sensing resolution = 0.25 degree At 100ft. (30m) distance, detection width is only 5 inch. (13cm). Redscan is sampling every 0.25 degree. It means that Redscan protects 180 degree area with 720 beams and 190 degree area with 760 beams.
Training purpose only. Do not duplicate. Detection areas REDSCAN, RLS-3060 can be installed vertically, horizontally or at an angle. Therefore a horizontal or vertical or inclined detection area can be achieved Detection range is 100ft. (30m) radius, 190 degree.
Training purpose only. Do not duplicate. Detection areas REDSCAN, RLS-3060 can be installed vertically, horizontally or at an angle. Therefore a horizontal or vertical or inclined detection area can be achieved Detection range is 100ft. (30m) radius, 190 degree.
Training purpose only. Do not duplicate. Conventional PIRLaser Scan Sensor REDSCAN REDSCAN detector has 190 degree detection area. Therefore, No dead spots Very flexible and Precise detection area setting REDSCAN REDSCAN has the capability to recognize the intrusion location in 4 detection area segments and is linked to 4 outputs. Therefore, Ideal match for PTZ camera preset control Benefits of Redscan Vertical detection area Horizontal detection area
Training purpose only. Do not duplicate. Connection (Analog) Power supply Alarm outputs for each area (A1,A2,B1,B2) × 4 Tamper output Self check trouble output Environmental trouble output Master Alarm output (N.O./N.C.) Ethernet port(RJ-45) Analog PTZ REDSCAN PC Power supply 24VDC/AC Peripheral equipment * Set up * Update software DVR
Training purpose only. Do not duplicate. PTZ preset control Connection (IP connection) PTZ preset control Power supply 24VAC/DC TCP/IP Alarm information Detected human position Environmental signal Trouble signal Tamper output Ethernet port ( RJ-45 ) IP PTZ camera REDSCAN Switch UDP * Set up * Update software Analog Can receive generic event codes Generic Event Code PC with Video/Alarm management software or NVR
Training purpose only. Do not duplicate. Feature RLS-3060 generates the generic event codes from its communication port. PTZ preset control by RLS-3060 via NVR or VMS which has the capability to receive generic event codes through an IP network. IP connection (Generic event code) Communication methods Send generic codes to assigned port on UDP Code format XXXX_y1 to y9 *“XXXX”: ID number of the RLS-3060 unit (4 –6 bytes). Number is RLS + the host address of the RLS Default: RLS126 * y: Status code of RLS-3060 (18 bytes) * When no event, “ ⊔ “(space) is generated. (Space is expressed as “ ⊔ ”, for convenience.) Example.) When the unit detects in A2 area and also the laser window get dirt, the following event code is generated. “RLS126MOA2 ⊔⊔⊔⊔⊔⊔⊔⊔⊔⊔⊔⊔ SO“. IP address and port number which the RLS-3060 send the event code to can be changed. * Default value IP address: Port number: 1234
Training purpose only. Do not duplicate. Visualized detection area Easy parameter and detection area setting on PC software REDSCAN PC Ethernet port(RJ-45) Redscan Manager Software
Training purpose only. Do not duplicate.Specifications
For reliable installation of Redscan
Training purpose only. Do not duplicate. Selection of detection pattern Vertical detection area It creates an invisible wall. Suitable for inside / outside of perimeter fence / wall or immediate perimeter of building to control PTZ preset. The minimum interruption time is 100msec. So, need to install unit where people can not run through the detection area otherwise install the unit at an angle. (0 to 45 degree) Horizontal detection area It creates a fan like semicircular area. Suitable for open area and field zone protection with cameras. Installation height of detector recommended at 28 inch (70cm). If there is a possibility that people can crawl under the area, set the unit at an angle or use multiple units or consider a back-up detector.
Training purpose only. Do not duplicate. Planning installation Site survey and hints to planning the location of detector What does the system protect? Perimeter line, just around the building, between building and perimeter? Select the detection pattern, vertical or horizontal detection patterns. How big is the site? Calculate the detection distance required, both in length and width. Then, consider how many Laser Scan detectors are required. Are there any potentials of False alarms/Miss alarm? Are there any bushes, trees, vehicles or any objects to obstruct the beam path? Laser beam can not detect beyond the obstructions. Unnecessary areas can be masked. But, as much as possible, the detection area should be set not to see any unnecessary area. Confirm the detection area can be covered by camera Miss alignment of detection area and camera view means that the operator can not see the crucial image on the screen. The detection area should be within camera view. Location of Laser Scan Detector The detection area is approx. 100 ft. (30m ) radius, 190 degree and the thickness of beam is approx. 8 inch (20cm) at 100 ft. (30m) distance. When mounted with a vertical detection pattern, the unit should be installed at a position for the beam to hit the ground squarely.
Training purpose only. Do not duplicate. Correct installation Power cables ·As with any electrical wiring, the longer the wire run, the greater the electrical resistance and therefore voltage drop. Use the recommended wire as the per the instructions. Note, increasing the number of detectors powered by the same wire, results in a voltage drop proportional to the number of units added. ·Never run wiring overhead, where accidental damage can occur, while passing underneath. ·Avoid exposed wiring, protect by running wiring through conduit.
Training purpose only. Do not duplicate. Installation procedures – Vertical detection pattern 1.Mounting the unit 2.Detection Area setting 3.Sensitivity setting 4.Offset setting.
Training purpose only. Do not duplicate. Installation hints for Vertical detection pattern Installation should be conducted strictly in accordance to the Installation Instructions supplied with the unit. 1. Mount the unit ·The mounting height should be up to 15m (Approx. 50ft.). Recommended height: m (Approx. 23 – 50 ft.) ·Mount the unit on a wall or other solid surface. An unstable installation could cause false alarms. ·Direct or strong reflected sunlight on the face of the detector can affect the performance of detection. Do not face to sun, long grasses or water surface to prevent false alarms.
Training purpose only. Do not duplicate. Installation hints (1). Detection Area setting
Training purpose only. Do not duplicate. Installation hints (2). Detection angle setting
Training purpose only. Do not duplicate. Installation hints (3)
Training purpose only. Do not duplicate. Installation hints (4) 3. Detection Area setting
Training purpose only. Do not duplicate. Detection mode selection
Training purpose only. Do not duplicate. Advantage for Installation ・ Auto mode (Auto learning) By using this mode, the unit can determine the contours of the site and set the detection area automatically. (The detection range is within the area which is set by the range selector dial.) Vertical detection area Ground Manual setting The unit follows uneven ground and produce uniform detection coverage. Note: Detector mounting is critical to achieve maximum detection performance.
Training purpose only. Do not duplicate. Offset setting
Training purpose only. Do not duplicate. Early detection for fence lines!! REDSCAN can detect a person: Lifting, Climbing or Cutting fences Early detection for fence lines!! REDSCAN can detect a person: Lifting, Climbing or Cutting fences Advantage for Installation Normally it’s difficult to create detection areas outside of fence lines, however REDSCAN can do that.
Training purpose only. Do not duplicate. Advantage for Installation REDSCAN saves time for design & installation and therefore costs. The REDSCAN automatically detects and learns the contours of the ground wherever you install!!, even for uneven ground. Ex. Active photo beam 60m REDSCAN 60m
Training purpose only. Do not duplicate. Advantage for Installation REDSCAN automatically adjusts for environmental changes. (When the Auto mode switch P2 selected. If P1 position selected, detection area is fixed.) REDSCAN can refresh the ground shape automatically every hour for changes in snow or vegetation growth. Auto Refresh area learning
Training purpose only. Do not duplicate. Advantage for Installation It is not necessary to install several sensors on a building surface. REDSCAN brings a new installation design concept to the market. REDSCAN can make an invisible wall, it will provide the optimum solution for building surface protection!!
Training purpose only. Do not duplicate. Advantage for Installation It is not necessity to install sensors with fence line for perimeter security. REDSCAN will bring a new installation design to save time and cost. REDSCAN can be installed at an angle to a wall, reducing installing cost dramatically!! A1 A2 B1 B2
Training purpose only. Do not duplicate. Perimeter surveillance for Narrow boundary!! REDSCAN can installed in a narrow boundary zone. Perimeter surveillance for Narrow boundary!! REDSCAN can installed in a narrow boundary zone. Advantage for Installation
Training purpose only. Do not duplicate. No risk to run through at high speed Risk to run through at very high speed Recommended Installation [ Human running ]
Training purpose only. Do not duplicate. 0 degree angle Min. 33sec at 100m can be detected Possible to run at this speed RISK of Running Through Recommended Installation 20 degree angle : Min. 15sec at 100m speed can be detected Impossible to run at this speed * Sensitivity setting : H, Width of Human : 30cm, Human height : 170cm [ Human running ] Video
Training purpose only. Do not duplicate. Recommended Installation
Training purpose only. Do not duplicate. Recommended Installation
Training purpose only. Do not duplicate. 0 ( zero ) degree angle vertical installation RLS-3060 CAN DETECT detect target 35cm height in the following case 35cm height 0 degree angle DETECTION Recommended Installation
Training purpose only. Do not duplicate. 0 ( zero ) degree angle vertical installation RLS-3060 will NOT detect target 30cm height in the following case 30cm height 0 degree angle NO DETECTION Recommended Installation
Training purpose only. Do not duplicate. Over 30 ( zero ) degree angle vertical installation RLS-3060 CAN DETECT target 30cm height in the following case 30cm height 30 degree angle DETECTION !! Recommended Installation
Training purpose only. Do not duplicate. No Angle Vertical Mount But no chance to crawl Right surface on the wall or fence 0 degree angle vertical mount Crawling may happen OK NG Detection No Detection Recommended Installation
Training purpose only. Do not duplicate. Recommended Installation Maximum detection distance (m) Mounting Height (m)
Training purpose only. Do not duplicate. Recommended Installation [ Water’s edge] Offset Installation on Water’s edge Angle installation with Vertical mode Water reflection may cause false alarm Video
Training purpose only. Do not duplicate. Installation procedures - Horizontal Detection Pattern 1.Mounting the unit 2.Wiring 3.Detection Area setting 4.Masking far area
Training purpose only. Do not duplicate. Installation hints for horizontal detection pattern Installation should be conducted strictly in accordance to the Installation Instructions supplied with the unit. 1. Mount the unit ·The mounting height should be around 28 inch. (70cm) in order for the beam to hit waist / hip of people. ·Mount the unit on a wall or a solid surface. An unstable installation could be a cause of false alarms. ·If there are obstacles in the laser path, it can not detect beyond the obstacles. ·Direct or strong reflected sunlight on the face of the detector can affect the performance of detection. Do not face to sun, grasses, water surface to avoid affection. ·Do not install the Redscan unit sideways.
Training purpose only. Do not duplicate.. Detection Area setting Installation hints (1)
Training purpose only. Do not duplicate. Installation hints (2). Detection Area setting
Training purpose only. Do not duplicate. Advantages for Installation Auto mode (Auto learning) By using this mode, the unit can check the shape of the site and set the detection area automatically. (The detection range is within the area which is set by the range selector dial.) Horizontal detection area
Training purpose only. Do not duplicate. Advantages for Installation Auto mode (Auto Tracing) By using this mode, within the 100ft. (30m) radius 190 degree arc, you can make the necessary detection area by pushing set button and walking the perimeter of required area.
Training purpose only. Do not duplicate. Laser scan beam needs to be kept parallel to ground. Recommended Installation Sloping ground NO DETECTION DETECTION!! Horizontal installation Sloping ground situation DETECTION!! Sloping ground
Training purpose only. Do not duplicate. There is a risk to detect though glass windows. Please do not use P1 mode. Please make detection area by P2 mode or REDSCAN MANAGER. Recommended Installation Glass window Through the glass window
Training purpose only. Do not duplicate. Thank you very much. All information is provided as references without any warranty of any kind, either expressed or implied, including but not limited to fitness for a particular use. Any user shall assume the entire risk as to the accuracy and use of these information.