APM Automation Solutions Ltd. The New 3DLevelScanner Software Eran Perlstein, Customer Support Director.

Slides:



Advertisements
Similar presentations
Questions & Answers Eran Perlstein, Customer Support Director.
Advertisements

DSL-2730B, DSL-2740B, DSL-2750B.
© 2010 APM Automation Solutions Ltd. All rights reserved. APM Automation Solutions Ltd. 11 APM Customer Support Technical Training Part 5 Operation & Troubleshooting.
DAP-1520 FAQ’s Wireless AC750 Dual Band Range Extender.
DSL-2870B How to Change ADSL Username and Password in your modem router How to Change Wireless Channel in your modem router How to Open Ports in your modem.
Chapter 6 Chapter 6: Server Configuration. Chapter 6 Learning Objectives n Explain how to use the tools in the Control Panel n Install and configure the.
© 2007 APM Automation Solutions Ltd. All rights reserved. Contact Rubi Dan: APM Automation Solutions Ltd. 11 APM Customer Support Technical.
© 2008 Cisco Systems, Inc. All rights reserved.Cisco ConfidentialPresentation_ID 1 IT Essentials PC Hardware and Software 4.1 Instructional Resource Chapter.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
Chapter 22 All About SCSI.
14.1 © 2004 Pearson Education, Inc. Exam Planning, Implementing, and Maintaining a Microsoft Windows Server 2003 Active Directory Infrastructure.
11 INSTALLING WINDOWS XP Chapter 2. Chapter 2: Installing Windows XP2 INSTALLING WINDOWS XP  Prepare a computer for the installation of Microsoft Windows.
MCDST : Supporting Users and Troubleshooting a Microsoft Windows XP Operating System Chapter 9: Troubleshooting Power Management and I/O Devices.
Lesson 18: Configuring Application Restriction Policies
© 2010 APM Automation Solutions Ltd. All rights reserved. APM Automation Solutions Ltd. 11 APM Customer Support Technical Training Part 1 Technology.
TECHNICAL TRAINING PART 3 COMMUNICATION APM Customer Support May 2011 APM Annual International Partners Conference 1.
A Quick Review of Unit 1 – Recognizing Computers Computing Fundamentals © CCI Learning Solutions.
MZ790 Print Driver and RINC Software Install and Setup These instructions are to assist you in installation and setup of the MZ790 Print Driver and RINC.
AccuMax Multi-Point Injection Mechanics
ClubRunner Connect. Communicate. Collaborate. ClubRunner and Rotary International Database Integration Introduction and Overview Introduced: November 2010.
®® Microsoft Windows 7 Windows Tutorial 10 Improving Your Computer’s Performance.
1. 2 LXU800 User’s Manual 1.Installation – Windows XP UI Features Introduction Data Connection & Disconnection.
Chapter 8 All About SCSI.
DWR-113 FAQ’s 3G WiFi Router.
The MVL Multi-Scanner System ACCURATE VOLUME MEASUREMENT OF BULK SOLIDS IN PRACTICALLY ANY KIND OF WIDE SILOS, OPEN BINS AND LARGE STORAGES May 2011 APM.
Configuring the MagicInfo Pro Display
AT91SAM9261-EK WinCE 6.0 DEMO ATMEL AT91 Application & Support Group
Windows XP Professional Windows XP Professional Overview Install and Upgrade Windows XP Pro Customize and Manage Windows XP Pro Troubleshoot Common Windows.
Tutorial 11 Installing, Updating, and Configuring Software
Remote Service Solutions ATS 8550
Hands-On Virtual Computing
Ircon ® ScanIR ® 3 Linescanner How to work with Snapshots? Confidential Rev. A 07/2013.
6.1 Using AMO After this class, you will be able to: Install AMO
Home Media Network Hard Drive Training for Update to 2.0 By Erik Collett Revised for Firmware Update.
Sage Metering Service Department
APM Automation Solutions Ltd. Inventory Management - 3DMultiVision Software and MVL System Eran Perlstein, Customer Support Director.
1 1 Local vs. remote intelligence A quick look at two different architecture management systems Copyright Nitrosoft 2010.
Windows Vista Inside Out Chapter 22 - Monitoring System Activities with Event Viewer Last modified am.
11 SUPPORTING APPLICATIONS IN WINDOWS XP PROFESSIONAL Chapter 9.
© 2010 APM Automation Solutions Ltd. All rights reserved. APM Automation Solutions Ltd. 11 APM Customer Support Technical Training Part 4 Configuration.
Ordering Tool Guideline
APM Automation Solutions Ltd. Special Installation Solutions Adi Idel Director of Engineering.
APM Automation Solutions Ltd. Good Installation Practice Guidelines Eran Perlstein, Customer Support Director.
Partners’ Webinar 01/31/2013 Karol Jarkovsky Solution Architect Upgrading Kentico.
APM Automation Solutions Ltd. RMA Procedure Eran Perlstein APM Customer Support 1.
6 th Annual Focus Users’ Conference 6 th Annual Focus Users’ Conference Import Testing Data Presented by: Adrian Ruiz Presented by: Adrian Ruiz.
11 INSTALLING AND MANAGING HARDWARE Chapter 6. Chapter 6: Installing and Managing Hardware2 INSTALLING AND MANAGING HARDWARE  Install hardware in a Microsoft.
SMS Software Distribution. Overview  Explaining How SMS Distributes Software  Managing Distribution Points  Configuring Software Distribution and the.
Module 8 : Configuration II Jong S. Bok
World Leaders in Combustion Management Solutions New Product Developments Autoflame Sales Meeting 2011 New Product Developments.
1 ARC reporting ARCCerny Verze INTERNET ARC events reporting Control panel 3. PSTN Telephone network - CID 1. GSM network – GPRS IP CID.
WEEK 11 – TOPOLOGIES, TCP/IP, SHARING & SECURITY IT1001- Personal Computer Hardware System & Operations.
Cscape EnvisionFX Horner APG, LLC March 7, EnvisionFX - What Does it Do? Graphical interface allows easy transfers of data to and from the PC and.
Microsoft ® Official Course Module 6 Managing Software Distribution and Deployment by Using Packages and Programs.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
Submitted by: DRPU Software Team Site:
Xxx Presentation, No 1 Copyright © TAC AB Engineering Classic Networks1.
Chapter 9 Advanced Assembly Modeling Techniques. After completing this chapter, you will be able to perform the following: –Create design view representations.
Communication.
3DVision GPRS connection
Complete Of Installation
Configuration and Monitoring
5708 startup and commissioning
New GPRS (GSM1318)modem wizard
5708 Models and Peripherals
SCADA, DCS and PLC.
GPRS Troubleshooting.
Pilot Watcher Product Overview V5.3
Commissioning – Remote monitoring
Chapter 11: Printers IT Essentials v6.0 Chapter 11: Printers
Presentation transcript:

APM Automation Solutions Ltd. The New 3DLevelScanner Software Eran Perlstein, Customer Support Director

Agenda Major differences between old and new versions of the 3DLevelManager –What we have now –Coming Release –Configuration Wizard –Advanced Parameters –3D Image –Grades Analysis –Using the Tabs in technician mode Troubleshooting May 2011APM Annual International Partners Conference2

What We Have Now Current versions in use: –3DlevelManager –3DLevelScanner FW –Locator –Modem Wizard –3DVision / 3DMultiVision May 2011APM Annual International Partners Conference3

Coming Release Due by the end of Q2 –3DlevelManager –3DLevelScanner FW –Locator 2.0 –Modem Wizard –3DVision / 3DMultiVision Note: Version numbers are subject to change May 2011APM Annual International Partners Conference4

General Major release of firmware requires a compatible software The new FW has several major changes in the algorithm The compatible SW has less features and parameters to configure The parameters are set and adjusted automatically by the new algorithm in the FW May 2011APM Annual International Partners Conference5

Configuration Wizard In step 2 – the bottom part can be asymmetrical, cone or pyramid, can be with the emptying point in any offset from the center of the vessel May 2011APM Annual International Partners Conference6

Configuration Wizard Step 7 – removed: Media Type (Frequency) and Process condition –In the new FW the frequency and the process condition are set automatically by the algorithm May 2011APM Annual International Partners Conference7

Advanced Parameters Most of the configuration parameters are not available any more All fields are in a single tab Removed: –Window size –Transmission Power –Extrapolation –Grades Filter –Rates and Capacity (exist in the configuration wizard) –CFAR sensitivity –Good SNR –Compressed pulses Added (moved from Extended Calibration Tab): –Dumping Time –Offset –Material angle May 2011APM Annual International Partners Conference8

3D Image New graphic design, similar to 3DVision Advanced settings: –Adding the scanner –Viewing filling and emptying points –Selecting material color –Display X, Y and Z axis –Option to save the 3D image –Various view modes –And more… Playing the stored 3D movie from the log files The installation package requires Microsoft.NET Framework 3.5 SP1 Note: If it is not possible to install the.NET Framework the 3DLevelManager installation package will install the existing visualization May 2011APM Annual International Partners Conference9

Grades Analysis Grades are calculated on 9 separated directional transmissions Additional view collects all transmissions on the same graph Grades Analysis and False Echoes Mapping to be executed for troubleshooting May 2011APM Annual International Partners Conference10

Functions in The Tabs View Most of the fields were moved into the advanced configuration window: –Dumping time –Offset –Steepest Material Slope –Historic Log Only two functions are left in the tabs: –Extended Calibration Tab – False Echo Mapping –Output Tab – Current Simulation and Output Mode May 2011APM Annual International Partners Conference11

Troubleshooting Remote Connection  It is recommended to have an option to connect to a remote site to provide immediate support  The options are:  Using 3DLinkPro – provide access to the scanners directly  Using TCP/IP – provide access to the scanners directly, requires assistance of local IT / system administrators  Using a 3G GSM USB stick – allowing to take control over the computer without the need of local IT  Taking control over the customer’s computer, by Logmein, Teamviewer, Showmypc, Webex, etc. May 2011APM Annual International Partners Conference12

Troubleshooting Scanner Behavior 1.Check and confirm the configurations with the customer and by actual measurements (Silo dimensions, Position of Scanner and Rates) 2.Check scanner orientation 3.Clean scanner (it always help even if there is small layer of dust inside the horns) 4.Upgrade to the most updated FW, reset to factory defaults and reconfigure manually (save the configuration file and upload it as reference) 5.Follow filling and emptying processes 6.Perform Grades analysis 7.Based on all information an educated conclusion can be made, for example:  Further fine tuning using the Advanced Parameters  False Echoes Mapping May 2011APM Annual International Partners Conference13

Troubleshooting GPRS Communication From the office 1.Check SIM card plan with the provider, confirm the possibility to send and receive SMS, GPRS is available and the quote / package limitation has not been reached 2.Call the SIM card number to verify an existing line 3.Send SMS to the SIM card, can be to reset the LinkPro: HW MODEM RESET On-Site 1.Check power supply to the 3DLinkPro, confirm same power supply to the scanners and LinkPro, check that the ratings are above 1 Ampere for the LinkPro and 120mA for each scanner, make sure there is mutual ground between the LinkPro and the scanners 2.Confirm that the RS-485 bus has two 120 Ohm resistors, one at each end of the bus 3.Use the Modem Wizard to configure and test the LinkPro and SIM card, set operation mode of the LinkPro according to the country May 2011APM Annual International Partners Conference14

Troubleshooting RS-485 Communication  Check that the connection between all scanners is Daisy chain  Confirm that the cable in use is suitable for RS-485 – has 120 Ohm impedance, twisted-pair, shielded  Make sure the shield is grounded on one end  Two 120 Ohm resistors must be connected on the communication lines at the ends of the RS-485 lines  Make sure that all scanners have same power supply, if not all must have the same grounding for communication reference  Each scanner has a different polling address May 2011APM Annual International Partners Conference15