High spatial resolution measurement of depth-of-interaction of a PET LSO crystal Aliz Simon a László Balkay b, István Chalupa b, Gábor Kalinka a, András.

Slides:



Advertisements
Similar presentations
Instruments for Radiation Detection and Measurement Lab # 4.
Advertisements

Advanced GAmma Tracking Array
Saeedeh Ghaffari Nanofabrication Fall 2011 April 15 1.
PET Design: Simulation Studies using GEANT4 and GATE - Status Report - Martin Göttlich DESY.
Recent news about SiPM based applications R&D in DESY Nicola D’Ascenzo University of Hamburg - DESY.
Chapter 8 Planar Scintigaraphy
Paul Sellin, Radiation Imaging Group Charge Drift in partially-depleted epitaxial GaAs detectors P.J. Sellin, H. El-Abbassi, S. Rath Department of Physics.
Geant4 simulations for the calorimeter prototypes D. Di Julio, J. Cederkäll, P. Golubev, B. Jakobsson Lund University, Lund, Sweden.
Geant4 simulations for the calorimeter prototypes D. Di Julio, J. Cederkäll, P. Golubev, B. Jakobsson Lund University, Lund, Sweden.
GEANT4 simulations for the Lund R 3 B prototype Douglas Di Julio Lund University, Lund, Sweden.
GAMMA RAY SPECTROSCOPY
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
Lecture 11  Production of Positron Emitters, Continued  The Positron Tomograph.
experimental platform
Instruments for Radiation Detection and Measurement Lab # 3 (1)
X-ray Diffraction Outline Crystals and Bragg Diffraction
Very High Resolution Small Animal PET Don J. Burdette Department of Physics.
Workshop on Physics on Nuclei at Extremes, Tokyo Institute of Technology, Institute for Nuclear Research and Nuclear Energy Bulgarian Academy.
X-Ray Medical Imaging Physics – IB Objectives
ON THE EFFICIENCY OF A LIDAR-TYPE SINGLE-SIDED GAMMA-RAY TOMOGRAPHY APPROACH Tanja Dreischuh, Ljuan Gurdev, Dimitar Stoyanov, Christo Protochristov*, Orlin.
Paul Sellin, Radiation Imaging Group Charge Drift in partially-depleted epitaxial GaAs detectors P.J. Sellin, H. El-Abbassi, S. Rath Department of Physics.
Fundamental Limits of Positron Emission Tomography
Scanning Electron Microscope (SEM)
Paul Sellin, Radiation Imaging Group Time-Resolved Ion Beam Induced Charge Imaging at the Surrey Microbeam P.J. Sellin 1, A. Simon 2, A. Lohstroh 1, D.
Crystal channeling 2009 A. Afonin, IHEP, Protvino New results of use and research of crystals at U-70. A.Afonin, IHEP, Protvino 4- th Crystal channeling.
AIR CORE SCINTILLATION DOSIMETER SUMMARY We have shown that Cerenkov light can be reduced to a negligible level in scintillation dosimetry by using an.
Position sensitive scintillation detectors for the trigger system in the space experiment NUCLEON Supervisors: Anatoliy I. Kalinin a Students: Irina Cioara.
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
Chris Hall Monash Centre for Synchrotron Science Monash University, Melbourne, Australia.
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Experimental Nuclear Physics Some Recent Activities 1.Development of a detector for low-energy neutrons a. Hardware -- A Novel Design Idea b. Measure the.
Seoul National University Functional & Molecular Imaging System Lab Progress in Nuclear Imaging Mikiko Ito, PhD Dept. of Nuclear Medicine, Seoul National.
ATF2 background and beam halo study D. Wang(IHEP), S. Bai(IHEP), P. bambade(LAL) February 7, 2013.
Geant4 User Workshop, Catania, Italy, 15th October, 2009
Development of a Segmented Planar Germanium Imaging Detector
Christoph Gabor, ASTeC HIPPI—Meeting (WP 5) 26 th – 28 th September 2007 Non—destructive transverse emittance measurement device The Front End Test Stand.
Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of.
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
Impact of Axial Compression for the mMR Simultaneous PET-MR Scanner Martin A Belzunce, Jim O’Doherty and Andrew J Reader King's College London, Division.
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
PSD-V, London, September 1999 Two dimensional readout in a liquid xenon ionisation chamber V.Solovov, V.Chepel, A.Pereira, M.I.Lopes, R.Ferreira Marques,
Scintillators suitable for PET applications must be characterized by a high efficiency for gamma-ray detection, determined by a high density and atomic.
Calibration of uniformity between LYSO crystals Zhigang Wang Institute of High Energy Physics, CAS The Third International Workshop on the High.
Lecture 12  Last Week Summary  Sources of Image Degradation  Quality Control  The Sinogram  Introduction to Image Processing.
Acquisition time6 min1 min 12 s Collimator height25 mm (Anger)12 mm (HiSens) Detector1 layer, 1 pixel / hole3 layers, 1 pixel / hole3 layers, 4 pixels.
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
The T506 Experiment: Electromagnetically-induced Radiation Damage to Solid-State Sensors Test Facilities Users Workshop SLAC, September Bruce Schumm.
Thickness of CZT detector 110 MeV140 MeV DETECTOR A (1 mm CZT + 5 mm CZT) DETECTOR B (1 mm CZT + 10 mm CZT) DETECTOR C (1 mm CZT + 15 mm CZT) A. Generation.
Medical Physics.
PET Imaging Positron Emission Tomography
V.Aulchenko 1,2, L.Shekhtman 1,2, B.Tolochko 3,2, V.Zhulanov 1,2 Budker Institute of Nuclear Physics, , Novosibirsk, Russia Novosibirsk State University,
+ Voxel Imaging Pizza Gianluca De Lorenzo. + Positron Emission Tomography April Gianluca De Lorenzo.
by students Rozhkov G.V. Khalikov E.V. scientific adviser Iyudin A.F.
P.E.T. Positron Emission Tomography
Laser wakefield accelerated electrons
PET Activities at UiO NFR Review E. Bolle*
MeV Ion Microbeams and Radiation Biology at the University of Surrey
Introduction to Scanning Electron Microscope by Sameer S
Development of a Compton Camera for online range monitoring
CELLION Technical Report
Diagnostics of FRIBs beam transport line
Reconstructions with TOF for in-beam PET
AQUA-ADVANCED QUALITY ASSURANCE FOR CNAO
OTR based measurements for ELI-NP Gamma Beam Source
Application of Nuclear Physics
Function and Structure in
Development of a Large Area Gamma-ray Detector
First demonstration of portable Compton camera to visualize 223-Ra concentration for radionuclide therapy Kazuya Fujieda (Waseda University) J. Kataoka,
一种基于晶体间光分享原理的深度测量PET探测器
Presentation transcript:

High spatial resolution measurement of depth-of-interaction of a PET LSO crystal Aliz Simon a László Balkay b, István Chalupa b, Gábor Kalinka a, András Kerek c, József Molnár a, Dezső Novák a, Attila Sipos a, János Végh a a Institute of Nuclear Research of the Hungarian Academy of Sciences, Debrecen, Hungary b Positron Emission Tomograph Center, University of Debrecen, Hungary c Royal Institute of Technology, Stockholm, Sweden International Workshop on Radiation Imaging Detectors University of Glasgow, July 2004

Outline Background Basic concepts of PET Challenges in small animal PET Our motivation Experimental Device under study Nuclear microprobe Microbeam irradiation of an LSO crystal ResultsPulse height spectra and maps as a function of position from the detector Depth of interaction Conclusions

Basic concept of PET PET scanner of PET Center, University of Debrecen

Challenges in small animal PET Increased Spatial resolution is needed Human body PETSmall animal PET Physical sizeHuman body:70 kgRat:300g, mouse30g Spatial resolution~10 mm (~1 ml in volume)<1mm (<1µl in volume) [1] A. F. Chatziioannou: Molecular imaging of small animals with dedicated PET tomographs, European Journal of Nuclear Medicine 29 (1): JAN 2002 Limitations of spatial resolution: positron range (~0.7mm tissue equivalent) non-collinearity of the annihilation photons parallax error [1] [2] A. Braema, et al., Novel design of a parallax free Compton enhanced PET scanner, NIMA 525 (2004) 268. Parallax error Schematic drawing of a PET device. The parallax error, influencing emission points far from the ring centre, is schematically shown.[2] A photon impinging on the entrance face of a detector with an oblique angle with respect to its axis can be detected not in that detector but in an adjacent one.

Different approaches to solve the DOI problem Improved and complex detector setup: (a) Phoswich detector approach (b) Stack approach (c) Detection of the light at the opposite bases of the scintillator The parallax error can be reduced or eliminated by measuring the interaction point of the photon along the detector. Depth of interaction DOI Our aim was to investigate the effect of DOI on a LSO scintillator with high resolution

Sample Commercially available LSO (Lutetium Oxyorthosilicate) 1x1x10 mm 3 crystal wrapped in a Teflon light reflector. A ~0.70 mm wide, vertical cut along the Teflon enabled us to irradiate the crystal itself. Measurement High resolution irradiation with a 2MeV He 2+ beam at a nuclear microprobe (beam size: 3x3  m 2, ion rate: 300Hz) Sequential scans of 1x1 mm 2 areas along the 10 mm long crystal DAQ with standard NIM Experimental details

Nuclear microprobe components B: analyzing magnet; C: condenser lens; S: beam steerer; Ob: object collimator; Ap: aperture collimator; P: vacuum pumps. Particle Detector Accelerator Probe Formning Lens System X-Y Scan Coils Si(Li) Detector Computer Display M.B.H. Breese, D.N. Jamieson, P.J.C. King: Materials analysis using a nuclear microprobe

Device under study LSO Crystal Block LSO crystal 1mm 0.7mm 1mm 10mm LSO crystal Teflon wrapping Hamamatsu Photomultiplier R5600

Intensity map 1x1mm 2 scan area, full energy window 128x128 pixel Pulse height spectrum of an 1x1mm 2 area (512 channel) Counts/Channel Channel number Results counts low high

Intensity maps counts Mean energy maps counts

Selected area spectra of 100  mx1mm areas are extracted 500  m

Pulse height spectra as a function of depth

Pulse height spectra of vertical areas (left centre and right ) between 5mm and 6 mm

Focused micro-ionbeam irradiation is a perspective technique to study the position sensitive characterisics of a PET detector. Conclusions We have demonstrated that the interaction between the generated light and detector can be studied with high lateral resolution (from  m up to mm). Further advantage of the ion beam irradiation that there is no Compton-scattering  there is no Compton-background in the spectrum. The mean value of the pulse height spectrum (~ position of the full energy peak) is characteristic to the DOI. Our results confirm previous gamma measurements on LSO crystal with similar geometry and wrapping. There is no difference between spectra collected from the left and right region of the crystal. By varying the beam energy the penetration depth of the ions can be changed giving opportunity for the real 3D light collection mapping. (2mm projected range for 20 MeV protons)

Acknowledgements This work was supported by the Hungarian Scientific Research Fund Contract No. OTKA T34381 and National Office of Research and Technology Contract No. 1/0010/2002.