Heat Recovery Ventilator Be used with AC system, Create a healthy life.
Content Product lineup Futures Structure & Dimensions Fan performance Specifications
Product line-up Model Air flow( m 3 /h) Power Supply HRV ~240V, 50Hz,1Ph HRV HRV HRV HRV HRV Model Air flow( m 3 /h) Power Supply HRV V,50Hz,3Ph HRV
Futures Energy saving Fresh-air and exhaust air cross the heat exchanger. Temperature exchanging happens. Fresh-air can get a great deal of energy from exhaust air. High efficiency. Thanks to the high quality paper-core heat-exchanger. 1.Good moisture permeability and air tightness Energy exchanging efficiency up to 74% 2. Good anti-combustibility More safety and reliability 3. Excellent tear resistance and aging resistance 4. Small air resistance.
High efficiency exchanger, saving more energy Heat recovery calculating equation (Winter) Indoor supply air temp. = (indoor air temp. – outdoor air temp.)* temp. recovery efficiency + outdoor temp. Example 14.8 ℃ = (20 ℃ – 0 ℃ )*74% + 0 ℃ Futures
Compact design and low noise Adopt sound absorption material, low noise. Compact design, easy installation and maintenance. Easy for installation Installed under girderInstalled at anomalous space Model:CE-HRV-200
Futures Different modes for your choice Exhausting mode (Hi Mid Low fan speed can be chosen) Air supply mode (Hi Mid Low fan speed can be chosen) By pass mode (Hi Mid Low fan speed can be chosen) Heat exchanging mode (Hi Mid Low fan speed can be chosen) Auto mode In this mode,the unit will run at heat exchange mode or by pass mode judge by OD temp. and ID temp. with low speed air flow.
Futures Introduction of By pass mode In this mode,there’s no heat exchanging happened,so saving energy. For example: If outdoor temp. is lower than indoor, we don’t need heat exchanging but we need flesh air.We can choose by pass mode. Remark: this mode only available for HRV-200~1000. Introduction of Heat exchanging mode In this mode,supply air flow = exhaust air flow. Fresh-air and exhaust air cross the heat exchanger.Then heat exchanging happen.
Futures Thanks to different modes The yearly AC load reduced 15% Yearly energy saving 15% Saving 20% energy Saving 6% energy Saving 2% energy By pass modeSupply/Exhaust mode Heat exchanging mode
Wired controller KJR-27B/E standard to choose different mode and timer function. Flexible control method Futures Central controller CCM03 realize On/Off function together with VRF indoor units
CE certification has been obtained. RoHS directive also. Certification Futures
The unit can diagnose itself by the LED inside the E-box. Self diagnosis function Futures
Structure & Dimensions
CE-HRV-200
Structure & Dimensions ModelLL1WW1W2HCGNN2 HRV Φ HRV Φ HRV Φ HRV Φ HRV Φ CE-HRV-300~1000
Structure & Dimensions CE-HRV-1500 CE-HRV-2000
Fan performance
ModelCE-HRV-200CE-HRV-300CE-HRV-400CE-HRV-500CE-HRV-800 Air volume(m3/h) Static pressure(Hi) (Pa) CoolingTemp. efficiency (%)60 Enthalpy efficiency(%)50 HeatingTemp. efficiency (%)65 70 Enthalpy efficiency (%)55 60 Power supply (V-ph-Hz)220~ Motor TypeAsynchronous Motor Power (W) Current (A) Dimension (L*W*H) mm666*580*264744*599*270744*804*270824*904* *884*388 Net/Gross Weight(kg)22/4623/4830/5735.5/ /91.5 Noise level dB(A) ControllerKJR-27B/E Specifications
ModelCE-HRV-1000CE-HRV-1500CE-HRV-2000 Air volume (m3/h) Static pressure(Hi) (Pa) CoolingTemp. efficiency (%)60 Enthalpy efficiency (%)50 HeatingTemp. efficiency (%)70 Enthalpy efficiency (%)60 Power supply (V-ph-Hz)220~ Motor TypeAsynchronous Motor Power (W) Current (A) Dimension (L*W*H) mm1116*1134* *1200*540 Net/Gross Weight(kg)59/95160/200175/215 Noise level dB(A) ControllerKJR-27B/E Specifications