Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee November 16, 2011 Mira Vowles, P.E., CEM.

Slides:



Advertisements
Similar presentations
eQuest Quick Energy Simulation Tool
Advertisements

HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Learning Outcomes Upon completion of this training one should be able to: Identify open loop and closed loop campus-type hydronic water system applications.
Ductless Heat Pumps in Residential Applications Proposed Research Plan.
Energy in Focus Energy Savings with Water Based Systems By Maija Virta Specialist of Indoor Environment Technology.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee September 28, 2011 Mira Vowles, P.E., CEM.
ASHRAE Presentation: VRF Overview Mitsubishi Electric Presenter: Phone number ©2011 Mitsubishi Electric& Electronics USA, Inc.
HVAC Systems Overview HVAC Overview - # 1 Tom Lawrence
VRF for the Seventh Plan Preliminary Approach and Data for a Variable Refrigerant Flow Measure for the Seventh Plan Regional Technical Forum January 21,
Active beams versus VAV with Reheat Analysis of May 2013 ASHRAE Journal article Ken Loudermilk Vice President, Technology & Developement.
Residential Variable Capacity Heat Pump Field and Lab Testing: Final Results 20 November 2013 Ecotope 1.
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
September 18, 2009 Critical Facilities Round Table 1 Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure.
 Install new air cooled high efficiency screw chiller (variable speed)  Install new fan coils with ECM motors and low temperature heating coils and proper.
Floating Head Pressure for Refrigeration Single Compressor Systems Michele Friedrich, PE – Sr. Engineer Dustin Bailey – Engineer PECI 11/2/2010.
CNN Center John Hester Turner Properties, Inc.. CNN Center Built in ,583,000 square feet on 18 floors Five structures joined by a common atrium.
1 Proposed Changes to the RTF’s Heat Pump Specifications Impact on Estimated Deemed Savings and C&R Discount Program Credits.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee April 25, 2012 Mira Vowles, P.E., CEM Emerging.
Premium Rooftop Unit (RTU) Retrofit Overview August 20, 2012 RTF RTU Working Group Mira Vowles, BPA 1.
Static Pressure Control Loop The purpose of the static pressure control loop is to maintain an optimal static pressure in the ductwork. The control loop.
SEEM Tool Overview Regional Technical Forum Member Orientation January 22, 2013.
1 Air Source Heat Pumps Potential Changes in the RTF’s Specifications & Savings Estimates and Their Impact on C&R Discount Program Credits.
Night Covers on Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
Air-Source Heat Pumps I North Seattle Community College HVAC Program Instructor – Mark T. Weber, M.Ed. Airsource Heat Pump 1.
DUCT EFFICIENCY AND HEAT PUMP PERFORMANCE Paul Francisco David Baylon Ecotope, Inc.
Retrofit Doors to Open Vertical Cases Provisional UES Proposal Presentation to the Regional Technical Forum August 30,
EvergreenEcon.com Heat Pump Water Heater Model Validation, Market Progress Assessment, and Process Evaluation RTF HPWH Sub-Committee Meeting October 15,
Prioritization of VC HP Measures Variable Capacity Heat Pump Measure RTF Sub-Committee June 22, 2011 meeting.
Rooftop Package HVAC Operations and Maintenance Measures: David Baylon Stan Price Bob Davis.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee March 27, 2013 Mira Vowles, P.E., CEM Emerging.
Lecture Objectives: Finish with HVAC Systems Discuss Final Project.
Foothill College & Space Science Center Bill Kelly Viron Energy Services (510) ext 13,
HVAC and DHW System Conversion Cost and Energy Use Assumptions for Direct Use of Natural Gas Analysis September 28, 2010.
July 26, 2014 Refrigeration Subcommittee Proposed Revision of Refrigeration Provisional Data Requirements.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee February 22, 2012 Mira Vowles, P.E., CEM.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee June 12, 2014 Mira Vowles, P.E., CEM Emerging.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee February 27, 2013 Mira Vowles, P.E., CEM.
GrocerSmart™ 4.0 RTF Approval of Software and Adherence to RTF Guidelines April 5, 2011.
PAGE 1 Sustainable Buildings 2030 © 2008 THE WEIDT GROUP Building Energy Benchmarks THE WEIDT GROUP.
Standard Protocol Development for Advanced RTU Control Retrofit August 15, 2013 Presentation to: Regional Technical Forum RTUG Subcommittee Sponsored by:
Deemed Savings Methodologies Reid Hart, PE Associate Director, Technical Research July 2009 – Regional Technical Forum.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump Sub-Committee Alternative Incentive Approaches BPA Energy.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee August 28, 2013 Mira Vowles, P.E., CEM.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee September 25, 2013 Mira Vowles, P.E., CEM.
Grocery VSD Measure Deemed Savings Reid Hart, PE & Ken Anderson September 28, 2010.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee July 24, 2013 Mira Vowles, P.E., CEM Emerging.
Greenbriar East Elementary School Fairfax, Virginia Michelle L. Siano Mechanical Option Spring 2005 Senior Thesis.
Energy Plus & Open Studio Class
Geothermal. Defining “Geothermal” Energy Dictionary definition – Relating to the internal heat of the earth The Earth acts as a giant solar collector,
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
Water is the Natural Choice Water: The Natural Choice For Efficiency – Unit efficiency versus Building System efficiency – Equipment Ratings EER and COP.
Water is the Natural Choice Water: The Natural Choice For Efficiency – Building System efficiency not just a unit rating – Equipment Ratings EER and COP.
A Reliable but Simplified Method for Measuring the Savings from Advanced RTU Control Retrofits February 13, 2013 Presentation to: RTF Commercial Rooftop.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump Sub-Committee Road-Mapping Session BPA Energy Efficiency.
VRF Applications in PNW RTF RTUG Meeting October 26, 2011 Kevin Campbell Reid Hart, PE Technical Research Group.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Performance Tested HVAC Presentation to the RTF January 5, 2010.
Green Server Room Construction Primary concerns when building a server room is size and cooling. Size can be diminished with the use of virtual servers.
Alexander Radkoff Mechanical Option | Spring 2014 Advisor: Dr. Stephen Treado 123 Alpha Drive Pittsburgh, Pennsylvania
GrocerSmart™ 4.0 RTF Approval of Software and Adherence to RTF Guidelines April 5, 2011.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Objectives Finish analysis of most common HVAC Systems
Types of HVAC Technology Used in Business Establishments
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Chilled Beam Performance:
Variable Refrigerant Volume
Frenger “Radiant” chilled beam performance at 1 Shelly St - Sydney
Case Study: Marks & Spencer Oxford Street
High Performance HVAC Installation
Calibrated Energy Models: One New Change
Presentation transcript:

Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Variable Capacity Heat Pump RTF Sub-Committee November 16, 2011 Mira Vowles, P.E., CEM Emerging Technology Project Manager BPA Energy Efficiency

Slide 2 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Meeting Agenda 1.EnergyPro Correction 2.Small Office Baseline Model Differences 3.Small Office VRF Heat Pump Model Differences 4.VRF Model Best Practice 5.Revised Definitions If we have time: –Discuss M&V best practice & standard protocol –Discuss compiling list of PNW VRF installations

Slide 3 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Seattle Small Office Energy Use Correction SEATTLE Energy Solutions Small Office RTU (kWh/SF)RTU (%) VRF (kWh/SF)VRF (%) Fan (kWh/SF) 6.473%0.727% Cooling (kWh/SF) 1.0*11%1.246% Electric (kWh/SF) 7.484%1.973% Heat (kBtu/SF) 4.716%2.427% Total (kBtu/SF) %8.9100% * Corrected to include duct loss adjustment

Slide 4 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Energy Solutions Small Office Model 7,200 square foot office modeled using EnergyPro 5 Baseline: Packaged rooftop air conditioner with gas furnace and constant volume fan ASHRAE system type 3 4 units, 6-8 tons each, fixed temp economizer, 1,080 cfm of OSA Included 28% cooling increase to account for conductive duct losses Included 37% fan energy increase to compensate for duct leakage VRF heat pump system with DOAS 2 Mitsubishi units, 10 to 12 tons each, no economizer, 1,080 cfm of OSA

Slide 5 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Energy Solutions & PECI Small Office RTU Gas-Pack Model Differences 1.Energy Solutions used EnergyPro and PECI used eQuest 2.Energy Solutions included significant Baseline duct losses 3. PECI included two-speed fans (fan at 35% when no heating or cooling loads) 4. PECI included server room which requires minimal heating

Slide 6 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Energy Solutions & PECI Small Office VRF Heat Pump Model Differences 1.Energy Solutions used EnergyPro Mitsubishi VRF performance modules 2. PECI used the eQuest “BSUG method” (PVVT model with compressor VSD and post processing heat recovery analysis) 3. PECI’s model doesn’t include refrigerant pipe losses 4. PECI included ventilation fan with 2.5” static pressure, while Energy Solutions used DOAS with unknown static pressure

Slide 7 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Seattle RTU Fan Energy Use Summary

Slide 8 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Small Office RTU Gas-Pack Modeled HVAC Energy Use Comparison

Slide 9 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Small Office RTU Gas-Pack Modeled HVAC % Use Comparison

Slide 10 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Small Office VRF HP Modeled HVAC Energy Use Comparison

Slide 11 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Small Office VRF HP Modeled HVAC % Use Comparison

Slide 12 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Building Simulation Program Issues  Due to the complexity of VRF systems (both VRF HR and VRF HP), building simulation programs are needed to estimate site-specific savings;  How can the accuracy of the building simulation programs be verified?  What are the important metrics?  Monthly energy use and average monthly temperature  Other?  Can building simulation programs provide these important metrics for verification purposes?

Slide 13 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N VC HP Building Simulation Model Best Practices –EnergyPro –TRACE –eQuest –Other?

Slide 14 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Modeling VC HP with TRACE TRACE can explicitly model VC HP, both heat pump and heat recovery systems: –Algorithms are based on Daikin empirical model –Inputs based on first generation Daikin VRV equipment modify to match current generation equipment or other manufacturer Heating COP or Cooling KW/ton Condensing Fan power consumption KW/ton Select unloading curve, compressor power consumption curve, condensing fan curve and cycling point as appropriate Based on April 15, 2009 BSUG meeting presentation

Slide 15 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Modeling VC HP with TRACE continued TRACE airside simulation When space temperature rises above the cooling setpoint, the cooling coil supplies air at a constant, cooling-supply-air-temperature until the setpoint is met; rejected heat is supplied to the refrigerant condenser loop. When space temperature drops below the heating setpoint, the heating coil supplies air at a constant, heating-supply-air-temperature until the setpoint is met, and the heat is removed from the refrigerant condenser loop. The default minimum reheat is 10%, or it can be entered on a room by room basis. When the heating and cooling coils are inactive, the minimum supply airflow at the mixed-air temperature is assumed; fan heat is, included. Based on April 15, 2009 BSUG meeting presentation

Slide 16 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Modeling VC HP with eQUEST Model as PVVT Water Source Heat Pump system Zone the building in the same manner as the design for representative heat recovery modeling Select a water cooled condenser with a condenser water loop Create one system per zone Create separate condenser water loops for each VRF condenser and zero out the pump energy Change the fan efficiency ratio and electric boiler EIR to reflect VRF efficiencies Based on April 15, 2009 BSUG meeting presentation

Slide 17 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Modeling VC HP with eQUEST continued Model as PVVT Air Cooled Heat Pump Create one system per zone Change to variable compressor speed Label systems and zones to according to which condenser each zone is connected to Create hourly reports with total heating and cooling energy use for each system Use spreadsheet to find simultaneous heating and cooling for each system, and sum the savings –This methodology is felt to be a conservative approach, which has been accepted by the USGBC on the Portland Mercy Corp LEED building –DOE-2 VRF system curves need to be developed Based on April 15, 2009 BSUG meeting presentation

Slide 18 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N How Accurate are Baseline and VC HP Models? –PNW EUI’s –EnergyPro EUI’s –eQuest EUI’s –How can we verify model accuracy?

Slide 19 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N

Slide 20 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N

Slide 21 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Small Office Baseline EUI Comparison Whole building Mean EUI = 75 (kBtu/SF), with a Standard Deviation of 13 (kBtu/SF)

Slide 22 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Medium Office Baseline EUI Comparison Whole building Mean EUI = 67 (kBtu/SF), with a Standard Deviation of 25 (kBtu/SF)

Slide 23 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Small Office VRF HP & Getting to Fifty EUI Comparison Whole building Mean EUI = 48 (kBtu/SF), with a Standard Deviation of 13 (kBtu/SF)

Slide 24 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Small Office VRF HP HVAC EUI Comparison HVAC EUI Mean = 9 (kBtu/SF), with a Standard Deviation of 1 (kBtu/SF)

Slide 25 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Medium Office VRF EUI Comparison Whole Building EUI Mean = 43 (kBtu/SF), with a Standard Deviation of 8 (kBtu/SF)

Slide 26 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Small Office VRF Savings Comparison Savings EUI Mean = 13 (kBtu/SF), with a Standard Deviation of 12 (kBtu/SF)

Slide 27 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Medium Office VRF Savings Comparison Savings EUI Mean = 11 (kBtu/SF), with a Standard Deviation of 3 (kBtu/SF)

Slide 28 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Office Building Definition  A building used primarily for office functions, including desk-work, reading and light equipment (computer, copier, printer, telephone, etc.) use.  Office occupancies are further defined by  overall occupant densities between 50 and 300 square feet per person,  overall lighting power densities up to 1 watt per square foot, and  overall equipment plug loads up to 1.5 watts per square foot.

Slide 29 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N VRF System Definition Variable refrigerant flow (VRF) systems, either heat-pump or heat-recovery styles, providing heating and air- conditioning, and typically consisting of: 1.Outdoor unit(s) with inverter driven compressor(s) and condenser fan providing improved part-load and low- ambient performance, 2.Multiple indoor units with multi-speed fans, electronic expansion devices, integrated zone temperature controllers and no electric resistance heating capacity, 3. Refrigerant piping between the outdoor and indoor units, 5. Ventilation provided by either natural ventilation or a dedicated outside air system (DOAS).

Slide 30 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N VRF System M&V Best Practice? –Meter baseline and VRF system electricity use for representative period, project to annual savings –Use calibrated Building Simulation model to predict annual savings and monthly electricity use –Verify savings by comparing actual monthly electricity use to predicted monthly electricity use

Slide 31 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N VRF System M&V Standard Protocol? –Use whole building regression analysis spreadsheet with representative period pre- and post- monthly electricity billing data and hourly average OSA temperature, –if savings are temperature dependant, over 15% of whole building electricity use and there are no other significant changes to electricity use, the whole building regression analysis spreadsheet can provide an confidence interval for savings

Slide 32 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Based on Energy Solutions EnergyPro model

Slide 33 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Based on Energy Solutions EnergyPro model

Slide 34 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Use Whole Building Analysis for VRF ROB Electricity Savings M&V? –Energy Solutions EnergyPro model predicts monthly electricity savings ranging between 21 and 33% –For the Small Office (7,200 SF) the monthly electricity savings ranging between 1,900 and 2,200 kWh Next Step: use whole building regression analysis spreadsheet, using EnergyPro model predicted monthly electricity use and Seattle hourly average OSA temperature

Slide 35 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Next Meeting –Scheduled for 12/21/11 at 9 am –Move to 12/14/11 at 9 am? Potential Topics: –Compare actual RTU annual fan kWh/SF to models –Develop VRF savings estimates (IEER plus fan?) –Compile list of PNW VRF installations & brainstorm how to “mine” for useful information –Develop M&V best practice and standard protocol –Develop research plan to verify model accuracy –NEEA RTU Replacement Discussion