DNV GL © 2014 SAFER, SMARTER, GREENER DNV GL © 2014 HVAC_3 Quality Maintenance 1 Research Plan.

Slides:



Advertisements
Similar presentations
HVAC Research Roadmap Summary.
Advertisements

eQuest Quick Energy Simulation Tool
Lighting EMV Roadmap Update Jeorge Tagnipes California Public Utilities Commission March 25, 2014.
PERFORMING EFFECTIVE BUILDING SYSTEM RECOMMISSIONING STUDIES Joseph J. Watson, P.E. Booth # 312.
E3 Calculator Revisions 2013 v1c4 Brian Horii June 22, 2012.
Planning for Updates and Linkages to EM&V CALMAC February 17, 2004.
CPUC EM&V WO54 – Market Assessment & Market Effects Baseline Characterization Market Effects Study of Investor-Owned Utility Residential.
DNV GL © 2014 SAFER, SMARTER, GREENER DNV GL © 2014 HVAC Permit and Code Compliance Market Assessment - MAPC 1.
Ductless Heat Pumps in Residential Applications Proposed Research Plan.
MENG 547 LECTURE 3 By Dr. O Phillips Agboola. C OMMERCIAL & INDUSTRIAL BUILDING ENERGY AUDIT Why do we audit Commercial/Industrial buildings Important.
Action-Oriented Benchmarking Paul A. Mathew, Ph.D. Lawrence Berkeley National Laboratory Berkeley California Using CEUS Data to Identify and Prioritize.
Evaluation of Energy Savings for Strip Curtains Presented To RTF Scott Moore PECI Sr. Engineer June 2, 2009.
2005 LIEE Impact Evaluation Final Report January 23, 2007 Presentation to the Low Income Oversight Board West Hill Energy and Computing, Inc. with Ridge.
DNV GL © SAFER, SMARTER, GREENER DNV GL © ENERGY Industrial, Agricultural and LARGE Commercial- 4(IALC4) 1 PY2013 NRNC WHOLE BUILDING IMPACT EVALUATION.
BPA Pre-Pilot, Monmouth  14 homes with installed DHP, single zone, single compressor.  11 Monmouth, 2 Moses Lake, 1 Tacoma  Savings.
Overview of the 2009 LIEE Impact Evaluation Workshop 1: “Overview of Lessons Learned” October 17, 2011.
INDUSTRIAL, AGRICULTURAL AND LARGE COMMERCIAL (IALC) ROADMAP CUSTOM IMPACT EVALUATION WEBINAR TO PRESENT RESEARCH PLAN Presentation July 28, 2014.
DNV GL © SAFER, SMARTER, GREENER DNV GL © HVAC-4 Webinar at CPUC ENERGY HVAC-4 Deemed Measures Study, Year 1 1 Public.
© 2001 The Gas Company. All copyright and trademark rights reserved. High Efficiency Unit Heaters Workpaper Presentation Prepared for Cal TF Presentation.
SDG&E Small Business Energy Efficiency (SBEE) SoCal Gas Non-Residential Financial Incentives Program (NRFIP) Evaluation Results Steve Grover ECONorthwest.
Performance Metrics for Weatherization UGI LIURP Evaluation Yvette Belfort Jackie Berger ACI Home Performance Conference April 30, 2014.
EDISON INTERNATIONAL® SM Internal Use Only Page 1 Circulating Block Heater Alfredo Gutierrez Cal TF Work Paper Presentation October 23, 2014.
DHP for Houses with Electric FAF Research Plan: Revisions Adam Hadley, Ben Hannas, Bob Davis, My Ton R&E Subcommittee February 25, 2015.
Implementation Update of PG&E’s LIEE Budget Application Presentation to the LIOB March 24, 2009 Burbank, CA Frances Thompson.
M&V Part 2: Risk Assessment & Responsibility Allocation.
EnergySmart Grocer Program Evaluation Findings Summary PWP, Inc.
DNV GL © 2013 Confidential April 10, 2014 SAFER, SMARTER, GREENER DNV GL © 2013 Confidential September 8, 2014 Jarred Metoyer ENERGY HVAC Permit Study.
Reviewing the Audit Results. Defining a Quality Base Year is Key to Maximizing Project Value n Base year is the mutually agreed upon pre-retrofit annual.
Results from the California Energy Efficiency Potential Study – Existing Residential and Commercial Jean Shelton July 27, 2006 San Francisco, California.
BPA RTU Winter Operation Presented to: RTUG August 2010 Presented by: Kathryn Hile, The Cadmus Group Howard Reichmuth, New Buildings Institute.
July 26, 2014 Refrigeration Subcommittee Proposed Revision of Refrigeration Provisional Data Requirements.
EvergreenEcon.com ESA 2011 Impact Evaluation Research Plan Public Workshop #1 February 20, 2013 Presented By: Steve Grover, President.
– 2011 STUDIES & PILOTS Low Income Oversight Board Meeting San Diego, CA Energy Division June 2, 2010.
1 Modeling Needs and Considerations for Energy Efficiency Ex Ante and Ex Post Savings Estimates Workshop: Energy Modeling Tools and their Applications.
Demand Response and the California Information Display Pilot 2005 AEIC Load Research Conference Myrtle Beach, South Carolina July 11, 2005 Mark S. Martinez,
BPA M&V Protocols Overview of BPA M&V Protocols and Relationship to RTF Guidelines for Savings and Standard Savings Estimation Protocols.
Experience you can trust. Phase 1: Cataloguing Available End-Use and Efficiency Load Data September 15, 2009 End-Use Load Data Update Project.
GrocerSmart™ 4.0 RTF Approval of Software and Adherence to RTF Guidelines April 5, 2011.
Deemed Savings Methodologies Reid Hart, PE Associate Director, Technical Research July 2009 – Regional Technical Forum.
New Construction Studies Performed by: MAESTRO/CALMAC Evaluation Showcase ● Pacific Energy Center ● July 26-27, 2006 EM&V of the Statewide Savings By Design.
Grocery VSD Measure Deemed Savings Reid Hart, PE & Ken Anderson September 28, 2010.
Utilities’ Update on Energy Savings Assistance Program Studies Ordered in D LIOB Meeting August 21, 2013 Sacramento, California.
BPA Impact Evaluation Policies QSSI. 2 Drivers: Industry Best practice, Power Act, RTF Guidelines, confidence savings.
PNW RoofTop Unit Working Group - RTUG – RTU Savings Research Project Phase 3 December 15, 2009.
Experience you can trust. Californial Industrial Energy Efficiency Potential CALMAC/MAESTRO Meeting San Francisco, CA July 27, 2006 Fred Coito
1 Summary of Reviews: Workpapers Approved by the California Technical Forum Part 2 Meeting: California Technical Forum January 28, 2016 Jeff Hirsch/Kevin.
Regional Air Source Heat Pump Performance and Savings Research and Evaluation Project Proposed Scope of Work and Estimated Budget February 10, 2004.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Performance Tested HVAC Presentation to the RTF January 5, 2010.
Click to edit Master title style 1 Energy Savings Assistance Program And California Alternate Rates for Energy (CARE) Program Proposed Decision.
Reminder about the Filed Trip Tomorrow 8 am St. Edward's University We will meet at 8:00 am at the south entrance of the new Science building (visitor.
GrocerSmart™ 4.0 RTF Approval of Software and Adherence to RTF Guidelines April 5, 2011.
2016 PG&E DATA CENTER BASELINE STUDY Jeff Stein, PE Brandon Gill, PE.
Metering and Measuring of Multi-Family Pool Pumps, Phase 1 March 10, 2016 Presented by Dan Mort & Sasha Baroiant ADM Associates, Inc.
Heat Pump Program Evaluation Baseline Practice and Conditions.
DNV GL © 2016 SAFER, SMARTER, GREENER DNV GL © 2016 HVAC 3 Quality Maintenance Program Year Impact Evaluation.
New Refrigeration Measures -Status Report- & -Request for Input- September 13, 2010.
Contract: EIE/07/069/SI Duration: October 2007 – March 2010Version: July 7, 2009 Ventilation for buildings Energy performance of buildings Guidelines.
Weather-Sensitive ERS Pilot Project Proposal March 7, 2013 TAC Meeting.
Formation of a Market Analysis Subcommittee Charlie Grist and Jennifer Light RTF Policy Advisory Committee February 19, 2016.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Performance Tested HVAC Presentation to the RTUG January 19, 2010.
1 Detailed EM&V Approach for each of BGE’s Proposed Conservation Programs January 10, 2008.
Local Government Partnerships Impact Evaluation Research Plan Itron Study Manager: John Cavalli CPUC Study Manager: Jeremy Battis July 20,
DNV GL © 2016 SAFER, SMARTER, GREENER DNV GL © 2016 HVAC 1 Upstream HVAC Program Year Impact Evaluation.
HVAC-4 Deemed Measures Uncertainty Study, Year 2
Lecture Objectives: Discuss Final Project
Best Practices in Residential Energy Efficiency
Py2015 California statewide on-bill finance
Energy Efficiency Evaluation Update Energy Division
Resource Adequacy Demand Forecast Coincidence Adjustments
Heat Pump Water Heaters: Evolution to a “California Essential”
Presentation transcript:

DNV GL © 2014 SAFER, SMARTER, GREENER DNV GL © 2014 HVAC_3 Quality Maintenance 1 Research Plan

DNV GL © 2014 Research Plan Objectives and Presentation Outline  Estimate Energy Savings from Quality Maintenance and related activities  Focus is on Commercial HVAC Maintenance – Includes Statewide QM Programs for SCE and PG&E – Includes PG&E AirCarePlus and SDG&E programs which are not within Statewide QM  OUTLINE – Background on Development of the Plan – Background on previous evaluation issues – Overview of plan components (gross and net savings) – Key measures evaluated – Types of Data Collection and Analysis – Public Comment Posting Instructions – Questions 2

DNV GL © 2014 Research Plan Development  Why not just do an analysis of customer bills? – Rigorous billing analysis requires a year of bills before and after an intervention where the intervention is expected to achieve 10% or more savings. – Maintenance occurring over multiple visits creates a problem that there is never a full year between events – The measures may be expected to save 10% of treated HVAC loads, but not 10% of total building usage. – It would not tell us any measure-level information, only building level and program level. – A very expensive evaluation using end-use metering has similar issues  Why are current estimates based on building simulations? – Workpaper and DEER estimates have to be created before programs occur – Evaluation goal is to estimate savings for this program cycle AND improve future workpaper and DEER estimates 3 Billing Analysis and metering do not provide measure level information and do not allow direct improvement of future workpaper and DEER estimates

DNV GL © 2014 Research Plan Development Process Methodology Evolution through the Research Plan Development Process Pre/Post Monitoring for site visits as in evaluation. Site level analysis using combination of spreadsheet and DOE-2* model analysis. *DOE-2 and eQuest are essentially the same thing, just different user interface. Post-maintenance site visits, recreation of pre-maintenance condition. Focus on five high impact measures and use spreadsheet models to determine impact of each measure. Expansion of ride along visits to include coil cleaning assessment. Site level analysis using either spreadsheet custom analysis and/or a DOE-2 building model for each site. Post-maintenance site visits with addition of pre-maintenance visits to determine baseline if program data is insufficient to determine baseline state. Analysis not at a site level, but at program level using DOE-2 to model DEER prototype buildings in the appropriate CA climate zones for each IOU. Model HVAC inputs are informed by field and lab data. 4

DNV GL © 2014 WO32 Challenges Difficulty coordinating with program implementers for pre/post maintenance visits. Solution: Coordination for pre/post visits not necessary as pre-maintenance and post-maintenance samples are now addressed differently, at ride-alongs for coil cleaning and recreation at post visits. HVAC efficiency measurements are not robust because mixed air temperature and relative humidity measurements were unreliable. Solution: Different method for mixed air temperature and relative humidity determination. Maintenance occurs over a period of 3 years so the pre-maintenance condition and post- maintenance condition can be significantly separated in time with poorly defined retrofit date. Solution: Not attempting pre/post monitoring. Site attrition and data issues caused smaller sample size than planned Solution: Conservative estimates of data sample points attained from site visits, and less attrition expected. Diagnostic tests to determine over or under charge give incorrect result when other faults are present (non-condensables, line restriction, low airflow.) Solution: Weigh in/out procedure for determining correct refrigerant charge 5

DNV GL © 2014 Overview of the Plan Impact Evaluation Gross Savings eQuest Model Workpaper Data Tracking Data Field DataLab DataNet to Gross Net to Gross Model Participant Survey Data Contractor Survey Data 6

DNV GL © 2014 Tracking Data 7 Non-Residential QM Measures and Savings Ranked by Percent of Total Non ‑ Residential QM Savings (Q1 – Q6)

DNV GL © 2014 Field Data Collection Methods Current 2015 program participants Collect data on coil cleaning measures 45 Ride Along Visits Completed program participants Collect data on RCA, economizer, thermostat and supply fan control measures 55 Post-Maintenance Visits 8

DNV GL © 2014 Ride Along Site Visits  Examples of the types of data we plan to collect at ride along visits: – Data to evaluate the evaporator and condenser coil cleaning measures such as – Suction pressure before and after cleaning – Discharge pressure before and after cleaning – Outdoor air temperature – Return air temperature – Supply air temperature – Baseline information such as: – Thermostat settings and EMS over-rides – Supply fan operating schedule – Economizer operational and if not note damper position 9

DNV GL © 2014 Post Maintenance Site Visits  Examples of data we plan to collect at post-maintenance visits – RCA measure – Weight of refrigerant in the system – Economizer measures – Economizer minimum setting airflow – Economizer maximum setting airflow – Economizer changeover setpoint and control strategy – Thermostat measure – Thermostat schedule and temperature settings – Supply Fan measure – Supply fan schedule 10

DNV GL © 2014 HVAC Instrumentation 11

DNV GL © 2014 Ex Post Savings Methodology  Still in development  Baseline data is incomplete.  Base savings on eQuest models of DEER building prototypes with non- faulted systems as the baseline, similar to the workpaper calculations.  We will collect data to improve workpaper assumptions. Where that is not possible we will use existing workpaper assumptions.  Coil cleaning: determine EIR/discharge pressure relationship from laboratory experiments. Measure discharge pressure change. Use EIR change in model.  RCA: determine EIR/% full charge relationship from laboratory experiments. Measure charge. Use EIR change in model  Thermostats and Supply Fan: determine schedule and use in model  Economizer: Model based on minimum, maximum airflow, changeover setpoint, and control strategy. 12

DNV GL © 2014 Budget TaskBudget Task 1: HVAC PCG Reporting, Project Administration, and QC $125,000 Task 2: Develop Research Plan$160,000 Task 3: Staff Training and Field Procedure Pilot$290,000 Task 4: Interim Report$90,000 Task 5: Commercial QM Program Impact Assessment$600,000 Task 6: NTG Analysis$140,000 Task 7: Final Report$150,000 Total$1,555, Table 17: Project Budget by Task

DNV GL © 2014 SAFER, SMARTER, GREENER Posting Comments px; select “ ” program cycle and search “HVAC”. Public comment may be posted to the Public Document Area through Friday May 15, px 14 Jennifer McWilliams (mobile)