2013 RESIDENTIAL COMPLIANCE SOFTWARE PROJECT Program Advisory Committee (PAC) Meeting July 17, 2012 Bruce Wilcox, P. E. Berkeley CA

Slides:



Advertisements
Similar presentations
O AK R IDGE N ATIONAL L ABORATORY U. S. D EPARTMENT OF E NERGY 1 Building Data Entry NEAT/MHEA Common Errors Oak Ridge National Laboratory Weatherization.
Advertisements

Chapter 3. HVAC Delivery Systems
Presents 2012 Revisions to the NC Energy Code For Residential Building started after March 1, 2012.
J.B. Speed School of Engineering University of Louisville KEEPS Energy Management Toolkit Step 2: Assess Performance & Opportunities Toolkit 2J: Building.
EarthCraft: Insulating Strategies Energy Efficient Insulation Systems by Church Hill Homes.
November 20, 2012 Bruce Wilcox, P. E. Berkeley CA
HEAT LOSS & HEAT GAIN HEAT FLOW. Heat flows from high temperature to low temperature There are 3 types/methods of heat flow/transfer: 1.Conduction- through.
eQuest Quick Energy Simulation Tool
Heating, Ventilating, and Air-Conditioning
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
“Do not take anyone’s advice as to how this building should be assembled.”
Heating, Ventilating, and Air-Conditioning (HVAC)
2009 Washington State Energy Code Residential Sections
The Three Tiered Philosophy
NetZero & Hearth Products California Energy Commission Climate zones Appliance standards TDV – Time Dependent Valuation LCC – Lest Cost Calculation 2007.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov Energy Movement WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
An Affordable Energy Efficient Home Utilizing Solar and Wind Power and Solar Hot Water John Gardner, PE.
1 Meeting ASHRAE Fundamentals, Standard 55 & 62.1 with Chilled Beams Displacement Ventilation.
The House as a System 1. Air Temperature and Water Vapor.
C A L I F O R N I A E N E R G Y C O M M I S S I O N 2013 Building Energy Efficiency Standards Residential Zoned AC Discussion August 18, 2011.
Heat Loss & Gain Calculations 1. How Heat Moves in Homes Conduction is the transfer of heat through solid objects, such as the ceilings, walls, and floors.
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
Standardized Curriculum WAP Training Plans and Resources.
ENERGY STAR Multifamily High Rise Program Testing and Verification Protocols Webinar – Part II August 2011.
Chapter 4: Air Leakage Control: Materials and Techniques
 On average, home heating uses more energy than any other system in a home  About 45% of total energy use  More than half of homes use natural gas.
Massachusetts “Stretch” Energy Code Marc Breslow Executive Office of Energy & Environmental Affairs.
Adriana Galue Wolfgang Custom Finishes HOME ENERGY STATS Biggest energy consumers Space heating – 34% Appliances and lighting – 34% Refrigerator.
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
MECHANICAL ASPECTS OF MICHIGAN UNIFORM ENERGY CODE MIAM DOHERTY INN CLAIRE, MICHIGAN MARK RILEY.
Arkansas Energy Code 2004 Compliance
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
Brought to you by: Connecticut Energy Code Frederick F. Wajcs Senior Energy Engineer Northeast Utilities February 10, 2011.
BEM CLASS 5 Building Thermodynamics – 2 Air-conditioning Load Calculation – latent heat, solar and internal gains.
Massachusetts New Homes with ENERGY STAR ® The sponsors of the Massachusetts New Homes with ENERGY STAR are Bay State Gas, Berkshire Gas, Cape Light Compact,
Precedent Analysis arc 572 UT Solar Decathlon 2009 BLOOMhouse University of Texas at Austin I 2007 ARCHITECTURE I INTERIOR I TECHNOLOGY I SOCIETY architecture.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – December 2012eere.energy.gov Energy Movement WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Important variables Water: Air: Conversion:
Part 2: Buildings as a System Lee F. Ball Jr., PhD
Update on the SEEM Simulation Program Larry Palmiter and Ben Larson August 4, 2008 Ecotope Inc. Presented at Regional Technical Forum Portland, Oregon,
Objectives Finish talking about ways to minimize ventilation losses Discuss role of ducts in building energy use Describe coheating test methodology Interpret.
Michael Logsdon, Ben Larson, David Baylon 13 December th Avenue NE, Seattle, WA (206)
CALRES Update Phase 1 Progress Report April 22, 2009 Bruce Wilcox Phil Niles Ken Nittler.
Insulation and Infiltration
Ben Larson 1 November th Avenue NE, Seattle, WA (206)
Michael Logsdon, Ben Larson, David Baylon 13 December th Avenue NE, Seattle, WA (206)
 On average, home heating uses more energy than any other system in a home  About 45% of total energy use  More than half of homes use natural gas.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
INTRODUCTION TO HEAT LOAD HEAT LOAD12 3 TOPICS COVERED INTRODUCTION DESIGN CONSIDERATIONS DEFINITIONS/CONCE PT/FORMULA THE FORM LOAD COMPONENTS –External.
HVACR416 - Design Pressure Measurement Part 1. Why Measure? Need to Make Sure: All combustion appliances vent properly All HVAC systems are installed.
HEATING AND COOLING SYSTEMS
Title 24 Report Generator Robert Scott R ASENT Solutions Nov. 20, 2012.
1 1 Weatherization & Indoor Air Quality Impacts of Weatherization on Air Quality and Comfort Inside Your Home Prepared with the assistance of Jed Harrison,
VENTILATION AND FENESTRATION
Day 2 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Zone 4 R-38 Ceilings U-0.35 Windows, Doors R-13 Walls R-19 Floors R-10 Foundations.
NORTHWEST ENERGY EFFICIENCY ALLIANCE Affordable Performance Home Initial thoughts…… November 2011.
Day 4 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Technical Seminar on Application and Technical Specification June 2016
Chapter 32 Heating, Ventilation, and Air Conditioning.
Heat transfer Steady state conditions not for dynamic systems in buildings through walls, roofs, floors, windows, doors building structures and U-values.
Part 16 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Truss Heel Heights and Energy Code Requirements
Mark Hydeman, PE of Taylor Engineering
CONFIDENTIAL Technical Seminar on Application and Technical Specification 21 June 2016 Rezza Arif Bin Mustapa Kamal Senior Engineer Project And Application.
Introduction – Who am I? Environmental Project Manager – Trident Technical College Mechanical Engineer Licensed Builder South Carolina Accredited Commercial.
Adding Zones to Existing Systems
Announcements Exam 1 Next Class (Thursday, March 14th):
Presentation transcript:

2013 RESIDENTIAL COMPLIANCE SOFTWARE PROJECT Program Advisory Committee (PAC) Meeting July 17, 2012 Bruce Wilcox, P. E. Berkeley CA

7/17/2012Wilcox Residential Compliance Software Project RESIDENTIAL SOFTWARE COMPLIANCE PROJECT GOALS  Provide public software for 2013 Standards compliance  Improve accuracy, particularly in cooling, to support zero net energy goals  Foster collaborative software environment for the future

Project Technical Team  Bruce Wilcox Prime Contractor, Project Manager, Technical Lead  Chip Barnaby CSE Lead Programmer  Scott Criswell Compliance Manager Lead Programmer  Dave Krinkel Development Plan  Phil Niles CSE chief scientist  Robert Scott Compliance Form Generator  Ken Nittler Compliance Ruleset  Marc Hoeschele DHW Simulation  Doug Herr DHW Programmer  John Proctor HVAC modeling 7/17/2012Wilcox Residential Compliance Software Project 3

3 rd Party Tool Building Energy Code Compliance (CBECC) Compliance Manager Software HERS Ruleset 2013 Title-24 Compliance Ruleset & TDV Compliance Report Generator CSE Simulation Engine Transfer of building model (multiple arrows imply transfer of multiple building models) Transfer of compliance reports Diagram key: Inter-process communication of data and/or API calls Pale Blocks Possible future modules DHW Engine Compliance Data Registry 2013 Title-24 weather data Compliance User Compliance Data Repository

7/17/2012Wilcox Residential Compliance Software Project 5 Current Project Schedule

7/17/2012Wilcox Residential Compliance Software Project 6 CSE SIMULATION ENGINE STATUS  Energy calculation for “typical” buildings done and testing: Integrated & improved 2008 attic and duct models Multiple conditioned and unconditioned zones Pressure flow inter zone air flow network for infiltration, natural ventilation, mechanical ventilation and duct leakage State of the art ASHWAT window model Variable convective films and mass for all surfaces Sky temperature and radiant heat transfer for all surfaces Improved air conditioning model with latent load calculation

7/17/2012Wilcox Residential Compliance Software Project 7 CSE SIMULATION ENGINE STATUS  Not done yet: HVAC sizing for the simulation Central fan cooling ventilation (Nightbreeze etc.) Other HVAC systems:  Heat pumps  Hydronic and other unducted heating  Evaporative condensers Multi-segment duct model

7/17/2012Wilcox Residential Compliance Software Project 8 ENERGY CALCULATION RULES  Will be documented in the 2013 Residential ACM Reference Manual following the Compliance Manager data model organization  Prescribe the user inputs for compliance calculations  Explain how those inputs are used to set up the CSE and DHW calculations for the Proposed and Standard Design  Specify the Reporting and Verification required  For this presentation, focus is on new rules and rules that have changed To accommodate new and improved algorithms To respond to changes in the 2013 Standard

7/17/2012Wilcox Residential Compliance Software Project 9 RULES CATAGORIES  The Building/Project  Conditioned Zones  Attics  Other unconditioned zones

7/17/2012Wilcox Residential Compliance Software Project 10 THE BUILDING/PROJECT RULES Standards Version Dwelling Units Solar Construction Assemblies Cooling and Heating Subsystems Fan Subsystems Distribution Subsystems HVAC Systems Ventilation Systems Zoning Air Leakage and Infiltration

7/17/2012Wilcox Residential Compliance Software Project 11 STANDARDS VERSION  New Input: Standards Version Compliance 2014: through December 2014 (with current Federal Air Conditioning efficiency requirements Compliance 2015: any time (with 2015 Federal Air Conditioning Requirements)  Standard Design: AC efficiency at specified Federal level  Reporting: Standards Version SEER & EER if Compliance 2015

7/17/2012Wilcox Residential Compliance Software Project 12 DWELLING UNITS  Inputs For each dwelling unit type in the building input  Conditioned Floor Area (CFA)  Number of bedrooms For Multi-Family input the number of each dwelling unit type  Calculate the Indoor Air Quality (IAQ) Ventilation CFM for each unit type  Standard Design: Same Unit Types as Proposed Design  Reporting: Unit Types and minimum IAQ ventilation CFM’s for verification.

7/17/2012Wilcox Residential Compliance Software Project 13 SOLAR  For single family and town houses if  standards version is “Compliance 2015”  and Zone is 9-15  Then input the kWdc of the proposed Photovoltaic system (minimum 2 kWdc)  Calculate the PV compliance credit as the smaller of:  PV Generation Rate (kTDV/kWdc) * kWdc  Max PV Cooling Credit * Standard Design Cooling Energy (kTDV)

7/17/2012Wilcox Residential Compliance Software Project 14 SOLAR  PV Credit:

7/17/2012Wilcox Residential Compliance Software Project 15 CONSTRUCTION ASSEMBLIES  Replaces 2008 Joint Appendix 4 U-factor Tables  U-factor calculated in Compliance Manager for Prescriptive compliance and user feedback  U-factor is not an input to the CSE Simulation  Creates Layered constructions for CSE input  Material layers selected from CEC approved library  Flexible R values for insulation layers  Separate frame and cavity surfaces for frame constructions  Reporting: to be determined

7/17/2012Wilcox Residential Compliance Software Project 16 COOLING SUBSYSTEMS  Improved Cooling Algorithm  Adds calculation of indoor humidity and latent load  Evaporator air flow and conditions affect sensible heat ratio  New relationship based on R410 refrigerant  New input for fan motor type: PSC or BPM  Drop cooling size credit Little used No consensus on calculation or energy savings  New input, algorithm and report for bypass duct (TBD)

7/17/2012Wilcox Residential Compliance Software Project 17 HEATING SUBSYSTEMS Standard Gas Furnace algorithm unchanged from 2008 RACM (but the Federal minimum efficiency changes) New air source heat pump algorithm, inputs and reporting to be developed

7/17/2012Wilcox Residential Compliance Software Project 18 Fan Subsystems  Component of  Cooling and Heating systems  Ventilation Cooling systems  IAQ Ventilation systems Inputs  CFM  W/CFM  Type (PSC, BPM) Model  Fan operates at specified CFM in Airnet  Fan heat added to air stream

7/17/2012Wilcox Residential Compliance Software Project 19 Distribution Subsystems  Ducts in unconditioned spaces are an important component:  Cooling and Heating systems  Cooling, Heating and Ventilation systems Same model as 2008 with added features:  Multiple duct systems located in any zone (attic and crawl for example)  Improved treatment of insulation thickness and conductivity  Duct segments for accuracy and to support input of reduced area, buried ducts etc  Operates in ventilation mode to accurately model CFI IAQ ventilation systems

7/17/2012Wilcox Residential Compliance Software Project 20 HVAC Systems  An HVAC system is a collection of one or more of the following components:  cooling subsystem  heating subsystem  fan subsystem  Distribution subsystem Examples  Split system cooling subsystem, gas furnace, PSC furnace fan, ducts in attic  Whole house fan  Bathroom exhaust for IAQ ventilation  All components of a system use the distribution subsystem

7/17/2012Wilcox Residential Compliance Software Project 21 Cooling Ventilation Systems  Natural ventilation through openable windows  Mechanical Cooling Ventilation Whole House Fan Integrated Central Fan (Nightbreeze, Smartvent etc)

7/17/2012Wilcox Residential Compliance Software Project 22 Window Ventilation Cooling  Same inputs, defaults and reporting as 2008  Effectiveness reduced by 50% to reflect behavior and experience  Available from dawn to 11 PM  Modeled as envelope holes in airnet

7/17/2012Wilcox Residential Compliance Software Project 23 Whole House Fan Ventilation Cooling New measure for 2008  Input is total CFM of fans and W/CFM  Effectiveness reduced by 75% to reflect average behavior  Available from dawn to 11 PM (requires windows to be opened)  Modeled as exhaust fan from conditioned zone to attic in airnet  CFM and W/CFM from CEC fan listing Standard Design and default:  2 CFM/CFA at 0.1 W/CFM in single family in Zones 8-14 Reporting: Proposed CFM and W/CFM

7/17/2012Wilcox Residential Compliance Software Project 24 Integrated Central Fan Ventilation Cooling New measure for 2013  Available any hour of the day  Modeled as supply fan from outdoors to zones with relief to attic in airnet  Controlled on current vent setpoints and indoor-to-outdoor delta T  Fixed speed systems (Smartvent etc) input fixed CFM and fan W  Variable speed systems (Nightbreeze, etc) use manufacturer certified max CFM, W/CFM and off max functions Reporting: Type, CFM, W/CFM Verification:  Type, CFM & W/CFM at max flow  Duct leakage in air conditioning mode with damper normally closed (but not specially sealed)

7/17/2012Wilcox Residential Compliance Software Project 25 Indoor Air Quality Ventilation Systems Same functional requirements as 2008 New 2013 requirement to verify whole house outdoor ventilation CFM for each dwelling unit. Reporting:  Type, CFM for each dwelling unit, W/CFM Verification:  Type, CFM of outdoor air, and W/CFM if not default.

7/17/2012Wilcox Residential Compliance Software Project 26 Zoning the Building  Zoning the spaces in the building is optional (recommended for added accuracy even for single zone systems) A 40 ft2 opening will be assumed between adjacent zones Building components such as ceilings, floors, walls, windows and point source internal gains (such as the kitchen) must be assigned to the correct zone Heating and cooling, up to the CSE sized capacity of the system assigned to the zone, are assumed to be delivered to each zone as required to meet the scheduled set points. The location of duct system return grills must be input The Standard Design building has the same zoning as the proposed design.

7/17/2012Wilcox Residential Compliance Software Project 27 Zonal Systems  The cooling system zonal thermostats are deleted and all spaces operate in cooling at the conditioned zone set points  The heating system zonal thermostats and schedule are maintained for systems that meet the current requirements for that credit  An algorithm will be developed to model the impact of bypass ducts on cooling system performance

7/17/2012Wilcox Residential Compliance Software Project 28 Air Leakage and Infiltration  Envelope air leakage is a building level characteristic  Input is Air Changes at 50 Pascals (ACH50) measured according to the CEC approved method (copied from Resnet).  Default and Standard Design is 5 ACH50 for single family and multi-family homes 7 ACH50 for Townhouse leakage measured as a single unit  A lower value may be used for single family and townhouses if verified  Reporting: ACH50 if other than default

Envelope Air Leakage (ACH50)

7/17/2012Wilcox Residential Compliance Software Project 30 Air Leakage Distribution  Envelope air leakage is located at the building surfaces

Leakage Location Single Family

7/17/2012Wilcox Residential Compliance Software Project 32 Airnet Holes  The leakage in a surface is represented by 2 holes spaced vertically at 25% and 75% of the height of the surface  If the air in the space is warmer than air outside, air density (stack effect) causes air to flow in the bottom hole and out the top hole.  If the air in the space is colder the flow goes the other way

7/17/2012Wilcox Residential Compliance Software Project 33 Wind and Mechanical Effects  Holes are needed on each side because wind pressure is different on each side of the building (upwind, downwind and parallel sides assumed, wind is not orientation specific).  Fans and duct leaks change the pressure uniformly on the whole space  The combined pressure on each hole is the sum of the wind, stack and fan pressure (which may add or cancel each other)

7/17/2012Wilcox Residential Compliance Software Project 34 Multi-Zone  Gets pretty complicated…  There is also a hole between each pair of zones (door or stair)  Then we add Windows..  The Compliance Manager calculates the size and location of each hole  The Airnet calculation finds the air pressure in each zone that makes the air flows in the entire network balance

7/17/2012Wilcox Residential Compliance Software Project 35 CONDITIONED ZONES Dimensions and Location Internal Gains Exterior Surfaces Ceilings below Attics Exterior Walls Surfaces between Zones Interior walls, ceilings and floors Slab on grade floors Raised Floors

7/17/2012Wilcox Residential Compliance Software Project 36 Zone Location and dimensions  Location and dimensions added for Airnet Floor to floor height Elevation of the bottom of the Zone Window head height of the top windows  Zone types and thermostats are unchanged except The zonal cooling thermostats are deleted

7/17/2012Wilcox Residential Compliance Software Project 37 Surfaces Surface inputs unchanged except for Construction instead of U-factor Airnet holes automatically created in each wall, floor and ceiling. Hole size proportional to area as fraction of total area of surface type in building Ceilings below Attics  Defined in the conditioned space zone below  Air net hole to attic automatically created in each surface Floors, roofs and ceilings between zones  Dimensions and constructions must be entered in one zone  Openings defaulted to 40 square feet between conditioned zones in the same dwelling unit  Air net holes to unconditioned zone automatically created in each surface

7/17/2012Wilcox Residential Compliance Software Project 38 Windows  Window and skylight inputs and reporting unchanged  Shade operation for windows Interior shades half open during day, 80% closed at night Automatically operated exterior shades closed when air conditioning. Rules to be developed.

7/17/2012Wilcox Residential Compliance Software Project 39 Thermal Mass  Inside the zone light mass and surfaces are fixed: Light mass (Cair) is 2 BTU/CFA Interior wall with one side area equal to CFA Interior floor if multi-story zone Furniture made of 2.5” wood with one side are equal to 2 times the CFA No change to slab floors (default 80% carpet, 20% bare)

7/17/2012Wilcox Residential Compliance Software Project 40 HERS II Internal Gain  Internal gains according to HERS II formulas and schedule Appliance efficiency and fuel types default in both Proposed and Standard Design If multi-zone, specify the zone where point sources (such as kitchen) are located Added latent fraction to HERS II gains:

7/17/2012Wilcox Residential Compliance Software Project 41 Sensible Internal Gain Comparison

7/17/2012Wilcox Residential Compliance Software Project 42 UNCONDITIONED ZONES  Attic Floor Area Ventilation Attic Edge  Other zones (optional) Crawl Spaces Basements Garages

7/17/2012Wilcox Residential Compliance Software Project 43 Attic  Attic floor area defined by ceiling areas of zones below  Attic ventilation is no longer a compliance variable 1/300 soffit ventilation assumed Vent area increased if needed to provide a minimum of CFM/375 ft2 free area for cooling ventilation fan relief  Insulation in the attic Input is R value Insulation type (cellulose, fiberglass, foam, etc) is not a variable Assume R = 2.6/inch (light blown fiberglass)

7/17/2012Wilcox Residential Compliance Software Project 44 Attic Edge - Not Part of the Attic

7/17/2012Wilcox Residential Compliance Software Project 45 Attic Edge  Solution is to treat the attic edge area as a cathedral ceiling No heat flow to the attic from this area Attic floor area (and volume) reduced by the edge area Tapered insulation cross section (and truss path) on left above can be approximated by 2 rectangular sections on the right that provide nearly the same steady state heat flow and can be simulated as a 1 dimensional surfaces in CSE

7/17/2012Wilcox Residential Compliance Software Project 46 Attic Edge  Inputs Roof Pitch Distance from top plate to roof deck, default 3.5” Ceiling Insulation and Below deck insulation R Length of attic edge  For simplicity not an input  Assume 3 times the square root of Attic Floor Area  Compliance Manager generates the cathedral surfaces  Standard Design: default geometry with Prescriptive R  Reporting: Heel height for verification if not defaulted

7/17/2012Wilcox Residential Compliance Software Project 47 Other Unconditioned Spaces  Modeling (optional) for improved accuracy and flexibility Crawl Spaces Basements Garages  Rules to be developed  Default: Current rules (not modeled as zones)  Standard Design: Same modeling as proposed  Reporting: to be developed

7/17/2012Wilcox Residential Compliance Software Project 48 Other RACM Topics To Be Developed  Domestic Hot Water  Additions/Alterations  Testing