Repeatability of Anterior and Posterior Corneal Higher- Order Aberrations in 4 mm, 6 mm and 8 mm diameters measured by Pentacam System Jadwiga Wojtowicz.

Slides:



Advertisements
Similar presentations
Evaluation of Higher Order Aberrations in Eyes with Dohlman/Boston Keratoprosthesis and Comparison with Penetrating Keratoplasty and Normal Eyes K.Stasi.
Advertisements

Aberrometry and the Tear Film — Understanding new methods —
Asymmetric Keratoconus Study: Novel Tomographic Parameters to enhance sensitivity to detect abnormalities in eyes with normal axial curvature maps from.
Authors have no financial interest
Swept Source Optical Coherence Tomography for Evaluation of Posterior Corneal Changes after Refractive Surgery Dr. Tommy Chung Yan Chan Dr. Vishal Jhanji.
Comparison of corneal astigmatism measured with 3 devices Mariko Shirayama, M.D, Li Wang, M.D, PhD, Mitchell P. Weikert, M.D, Douglas D. Koch, M.D. Cullen.
Correlation Of Corneal Contour With Higher Order Ocular Aberrations (HOA) In Indian Eyes Manish Chaudhary MS Amit Gupta MS Advanced Eye Centre, Postgraduate.
Corneal Biomechanics, Pachymetric Progression Profile and Corneal Volume: Indices for Detecting Ectasia and Screening Refractive Candidates Renato Ambrósio.
Purpose We studied the interdevice agreement of three systems in the different measurements of the corneal and anterior segment biometric parameters. The.
David Zadok MD, Isaac Avni MD
Outcome of refractive surgery in keratoconus suspect eyes
Wavefront Sensing of the Human Eye
Nizar S Abdelfattah, M.D.1, Marina Israel2, Nermin Osman, M.D.3,
Evaluation of Corneal Parameters and Spherical Aberration After DSAEK Measured with Pentacam System Orkun Muftuoglu, Pawan Prasher, R. Wayne Bowman, Steven.
Effects of IOP Lowering Agents on Myopic Regression after Refractive Surgery Lim, Taehyung M.D., Hong, So Jin M.D., Cho, Beom Jin M.D., Ph.D. Chung Kyu-Hyung.
Correlation Between Corneal Biomechanics and Wavefront Aberrations Alejandro Rivera, MD Private Practice Mexico City The author has no financial interest.
Evaluation of Interface Reflectivity and Corneal Aberrations following DSAEK Hamid Khakshoor, MD Professor of Ophthalmology Mashhad University of Medical.
Characterization of Higher Order Ocular Aberrations (HOA) In ‘Normal’ Versus Myopic Eyes To Study The Effect Of Myopia On Higher Order Aberrations Amit.
Comparison of Wavefront and Corneal Aberration Changes after Advanced Corneal Surface Ablation and Femtosecond Thin Flap LASIK Tahra AlMahmoud, MBBS 1,
Occurrence of Retinal Detachment After Cataract Surgery Peter Jeppesen MD, PhD and Thomas K. Olsen, MD, DMSc Department of Ophthalmology Århus University.
A Fellow Eye Comparison of Aberrations, Modulation Transfer Function and Contrast Sensitivity After AcrySof IQ and AcrySof Natural IOL Implantation. Mayank.
Evaluation of Zonal Equivalent Keratometry Readings After LASIK Timmy Kovoor, MD Orkun Muftuoglu, MD V.Vinod Mootha, MD Steven Verity, MD R. Wayne Bowman,
ASCRS 08 Changes Of Higher Order Aberrations After Excimer Laser Treatment For Moderate Myopia by Means of Preoperative Wavefront Aberration Levels using.
The authors have no financial interest in the subject matter of this poster Yinfei Xu, Peter S. Hersh, MD, David S. Chu, MD Institutional Affiliations.
World Cornea Congress VI Michael K. Smolek & Panagiotis Kompotiatis Department of Ophthalmology LSU Eye Center of Excellence, New Orleans The authors.
ROTATING SCHEIMPFLUG TOPOGRAPHIC PARAMETERS IMPORTANT IN DISTINGUISHING NORMAL FROM KERATOCONIC CORNEAL MORPHOLOGICAL FEATURES Clayton Falknor, MD, Orkun.
Rajendra Gyawali Consultant optometrist, Male’ Eye Clinic Maldives
Khairidzan Mohd Kamal MD
LADARVision4000 Vs VISX CustomVue LADARVision4000 Vs VISX CustomVue CustomCornea CustomCornea A Comparison of Wavefront Guided Refractive Surgery outcomes.
Predicting visual performance from wavefront quality metrics in cataract Konrad Pesudovs Katja Ullrich NH&MRC Centre for Clinical Eye Research, Flinders.
Reproducibility of Optical Measurements in Pseudophakic eyes Using Double-Pass Measurement System St Thomas Hospital, London Anish Dhital, David Spalton,
ELEVATION AND PACHYMETRY VALUES IN NORMAL CORNEAS OBTAINED BY GALILEI ASCRS Boston April Vision Sana Research Group Vision Sana Research Group.
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
Partial Coherence Interferometry Failure Rate in a Teaching Hospital Leslie A. Wei 1,2, BA, Nickolaus P. Katsoulakis 2, MD, Theodoros Filippopoulos 3,
Analysis of Ocular Wavefront Aberrations in Post Penetrating Keratoplasty Eyes with Two Different Hartmann-Shack Aberrometers Adriana S. Forseto 1, MD;
1 Non-contact Specular Microscopy for Evaluation of Corneal Endothelium in Early Fuchs’ Endothelial Corneal Dystrophy Jianyan Huang 1, MD, PhD; Tudor Tepelus.
The Effect of Corneal Anterior Surface Eccentricity on Astigmatism after Cataract Surgery Choul Yong Park MD 1 Sung Jun Lee MD 1 Prabjot Channa MD 2 Roy.
LONG TERM OUTCOMES OF RESTOR IOL IMPLANTATION Lori Dao, Orkun Muftuoglu, V. Vinod Mootha, Steven M. Verity, R. Wayne Bowman, H. Dwight Cavanagh, James.
Evaluation of Corneal Tomography in Primary Pterygium Sahil Goel, MD (Presenting Author), Murugesan Vanathi MD *The authors have no financial interests.
Futoshi Taketani, MD,PhD,
بسم اللة الرحمن الرحيم. Limbal relaxing incisions versus penetrating limbal relaxing incisions for the management of astigmatism in cataract surgery Sara.
Sherman W. Reeves, MD, MPH 1,3,4 ; Jacob A. Kozisek, OD 1,2 ; Noumia Cloutier-Gill, OD 1,2 ; David R. Hardten, MD 1,2,3,4 Accuracy of Scheimpflug Imaging.
Ocular functional optical zone following hyperopic LASIK/PRK: Analysis based on polychromatic retinal image quality Mitchell P. Weikert, MD Li Wang, MD,
Jae Lim Chung MD, MBA 1,3 ; Jin Pyo Hong MD 2,3 ; Kyoung Yul Seo MD, PhD 3 ; Eung Kweon Kim MD, PhD 3 ; Tae-im Kim MD, PhD Noo Ne Eye Hospital, Seoul,
Financial Disclosure: Medical Director–Galilei R&D Consultant, Ziemer Group AG, Port, Switzerland Consultant & Territory Manager for.
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Authors: Leonidas Traipe Magdalena Rios Edison Villagra Allister Gibbons Marcelo Hidalgo Claudia Goya Authors have no financial interest.
Wavefront-guided Ablation Retreatment in Myopic Eyes Engy M Mohamed MD, Orkun Muftuoglu MD, R.Wayne Bowman MD, V. Vinod Mootha MD, H. Dwight Cavanagh MD,PhD,
Minimizing Risk in Visian ICL Implantation.
F.I. Camesasca, MD Zeiss Invent ZO Aspheric IOL: Long-Term Results of Refractive and Aberrometric Analysis F. I. Camesasca* P. Vinciguerra.
Evaluating Post Laser Refractive Surgery Corneal Thickness Using Artemis-2 Very High Frequency Arc-Scanning Ultrasonography Versus Pentacam * † Sharon.
CATz for Highly Irregular Corneas after Keratorefractive Surgery Hamed M. Anwar, MD, FRCS Alaa El-Danasoury, MD, FRCS 1 Institutional affiliation: Magrabi.
Date of download: 6/22/2016 Copyright © 2016 American Medical Association. All rights reserved. From: Effects of Graft Thickness and Asymmetry on Visual.
Corneal CXL in Pediatric Patients with Progressive Keratoconus Stephanie Wise, Christian Diaz, Karolien Termote, Paul J. Dubord, Martin McCarthy, Sonia.
CORNEAL ENDOTHELIAL PROFILE AFTER FERRARA RING IMPLANTATION Leonardo Torquetti, MD, PhD Paulo Ferrara, MD, PhD Paulo Ferrara Eye Clinic Belo Horizonte.
Department of Ophthalmology, University of Ulsan College of Medicine,
Characteristics of Primary Angle-Closure Glaucoma Patients with Normal Intraocular Pressure at the First Visit Won Hyuk Oh1, Bum Gi Kim1, Joo Hwa Lee2.
Charlotte ROHART1, Gilles Chaine1, Damien GATINEL2
Wavefront Optimized Retreatment after Prior Wavefront
Corneal High-Order Aberrations in Keratoconus
Refractive outcomes of intraoperative wavefront aberrometry versus optical biometry alone for intraocular lens power calculation Zina Zhang MD1, Logan.
Comparison of Single-Scheimpflug and Dual-Scheimpflug Pachymetry Measurements and Effect of Decentration World Cornea Congress VI April 7-9, 2010.
MP Weikert, M Shirayama, L Wang, DD Koch
Comparison of corneal powers obtained from four different devices
Eric Dai MD, Pawan Prasher MD, James McCulley MD, R. Wayne Bowman MD.
Asociación Para Evitar La Ceguera En México
Mohamed A Guenena, MD Helga P Sandoval, MD, MSCR Kerry D Solomon, MD
Preoperative Distribution of Higher Order Aberrations in Patients Undergoing LASIK Perry S. Binder, MS MD.
Lasik decentration with the VISX ActiveTrak™ System
Age-related difference in Lasik Treatment
Presentation transcript:

Repeatability of Anterior and Posterior Corneal Higher- Order Aberrations in 4 mm, 6 mm and 8 mm diameters measured by Pentacam System Jadwiga Wojtowicz MD, Orkun Muftuoglu MD, Engy Mohamed MD, V. Vinod Mootha MD, R.Wayne Bowman MD, H. Dwight Cavanagh MD, James P. McCulley MD, FRCOphth. UT Southwestern Medical Center. Department of Ophthalmology. Aston Ophthalmology Clinic, Dallas, TX. Financial Disclosure for all authors: *JPM: Consultant for Alcon Inc. (Fort Worth, TX) *JW, OM, EM, VM, DC: none Acknowledgements: Supported in part by an unrestricted research grant from Research to Prevent Blindness, Inc., New York

INTRODUCTION Eye aberrations plays a role in degrading retinal image quality.1 The distribution of the optical higher-order aberrations (HOAs) of the anterior and posterior cornea are essential for understanding the physiological optics of the eye and enhanced the outcomes of wavefront-guided therapies. It is well known that pupil diameter aperture changes influence HOAs. 2 Evaluating the intra-subject variability of anterior and posterior corneal HOAs at different pupil diameter areas with Pentacam will allow us: To evaluate corneal HOAs distribution in normal subjects. The variability of repeated scans measured with the Pentacam system. Liang J, Williams DR. Aberrations and retinal image quality of the normal human eye. J Opt Soc Am A 1997;14:2873-2883 Buhren J, Kuhne C, Kohnen T. Influence of pupil and optical zone diameter on higher-order aberrations after wavefront-guidede myopic LASIK. J Catract Refract Surg 2005;31:2272-80

METHODS Scheimpflug system (Pentacam Oculus, Inc.) was used to measure HOAs. Inclusion criteria: no symptoms or signs of ocular disease, other than refractive error, detected by history, slit lamp examination and fundoscopy Exclusion criteria: Dry eye patients Non-contact lens wearers Retinal disease Any systemic disease, the use of any eye-drops or oral medication that might affect the ocular surface. Six consecutive measurements were performed in each subject in both eyes in one visit by the same operator. The parameters analyzed were Zernike coefficients from 3rd to 8th orders from anterior and posterior cornea within a 4mm, 6mm and 8 mm diameter pupil area.

METHODS Statistical Analysis SigmaStat 2.03 Software (Systat Software Inc, Richmond, California, USA) was used. To study the intra-subject reproducibility of ocular HOA, SD and coefficient of variation (CV= SD/mean) were calculated.

Coefficient of variation (CV) of Corneal HOA RESULTS The study group consisted of 50 eyes from 25 normal subjects (13 females and 7 males). The mean age was 31 + 8 years Coefficient of variation (CV) of Corneal HOA Anterior Posterior Corneal HOA 8 mm 6 mm 4 mm 8mm 6mm 4mm Spherical 2.1 8.5 13.6 7 6.5 12.1 Coma 7.3 12.4 31.7 9.3 16.3 35 Trefoil 21 23 32 22 28 CV expressed as % Among the different zernike terms generated by Pentacam, Spherical aberrations was the most repeatable

Mean and SD for absolute Zernike coefficients from anterior and posterior corneal HOAs for 8, 6 and 4 mm diameter pupil area. Anterior Posterior Zernike Mode 8 mm 6 mm 4 mm 8mm 6mm 4mm Z3-1 0.541± 0.150 0.304± 0.094 0.143± 0.062 1.057± 0.579 0.622± 0.280 0.399±0.216 Z 3-3 0.137± 0.085 0.134±0.83 0.162± 0.078 0.487± 0.277 0.353±0.196 0.350± 0.173 Z4-0 1.381±0.160 0.551±0.102 0.162± 0.042 2.640± 0.633 1.404±0.303 0.503± 0.114 Z4-2 0.166 ± 0.077 0.109±0.059 0.056± 0.029 0.562± 0.258 0.356±0.172 0.172± 0.081 Z4-4 0.140 ± 0.101 0.139±0.071 0.087± 0.037 0.722± 0.315 0.594±0.225 0.313± 0.138 Z 5-1 0.052 ± 0.029 0.039±0.018 0.013± 0.006 0.527± 0.215 0.185±0.119 0.040±0.022 Z5-3 0.130 ± 0.061 0.076±0.036 0.022± 0.010 0.243±0.111 0.155±0.078 0.042± 0.024 Z5-5 0.113 ±0.037 0.052±0.030 0.015± 0.009 0.340 ±0.214 0.210±0.146 Z6-0 0.034 ± 0.022 0.015±0.009 0.002± 0.001 0.022± 0.104 0.099±0.052 0.014± 0.008 Z6-2 0.060± 0.030 0.023±0.011 0.004± 0.002 0.175± 0.082 0.089±0.039 0.017± 0.011 Z6-4 0.102± 0.037 0.044±0.019 0.008± 0.003 0.281±0.134 0.130±0.071 0.029± 0.027 Z6-6 0.089± 0.063 0.035±0.016 0.006± 0.003 0.385±0.243 0.163±0.104 0.026± 0.011

Pentacam image for anterior corneal HOAS

Pentacam image for posterior HOAS

CONCLUSIONS Corneal higher-order aberrations between third and sixth order derived by Pentacam showed more repeatability for both anterior and posterior cornea. Spherical HOAs showed higher repeatability than coma and trefoil. However Shankar et al 1, reported poor repeatability for HOAs measured with Pentacam, who exported the topographical maps to an external software for the analysis. More variability for Zernike polynomials was found within smaller measured zone. The Zernike distribution in normal subjects for the posterior cornea showed greater values than the anterior cornea, with the exception of Z4-0 1. Shankar H, taranath D, Santhirathelagan ChT, Pesudovs K. Repeatability of corneal first-surface wavefront aberrations measured with Pentacam corneal topography. J. cataract Refract Surg. 2008;34:727-734.