System Features Interactive Digital Addressable Fire Detection and Alarm System. Designed for Small and Medium Sized Installations.

Slides:



Advertisements
Similar presentations
Nexus 1-8 Loop (XP95) Analogue Addressable Control Panels
Advertisements

ID to 8 Loop Intelligent Fire Alarm Panel
Eagle Trading & Agencies has been established from the ground up for selling, managing and implementing mid to large size projects in the field of fire.
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
ModCon® 75 Controller.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Troubleshooting Training Course.  Visual and General Test  Perform System Test (Mode  Perform System Test)  Identify The Error  If you need Technical.
Discovery 1-4 Loop Analogue Addressable Control Panels
6000 Series Recorders. The Best Paperless Graphic Recorder in the World.
CERTIFICATON EN Wireless Fire Detection.
Unit Test Calibration Training
In this presentation you will:
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
Crown DSi Series Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display.
Introduction System Schematic ~ LON-FO NC EC200 LOOPS 2-4 FIBRE OPTIC
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
HARPER CHALICE GROUP LIMITED “PROTECTOR” PulseSecure ™ Fully monitored double pole High and Low voltage Perimeter security system”
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Training.
G GE Power Management MMII Intelligent MCC Controller.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Confidential Document 1 EverAccess Product Overview By Julian Garcia.
Precept Conventional Control Panels
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Graphical Alarm Management System
ONYX Product Overview.
INTRUSION ALARM TECHNOLOGY
Addressable Fire Alarms
HiVision SNMP Software.
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
Networking All talk - Selective listen Network up to 15 active nodes + 17 passive nodes Nexus/Discovery panels, network repeaters, R3 19” racks, Alarm.
G4 Control and Management Solution for Data- Centers and Computer Rooms.
RP-2000 Series Deluge & Agent Releasing Panels
Fire Detection Presentation
An Introduction to the Windows-based PC Programming Tool Version 0.91
FG Wilson Access 4000 Control Panel
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Single Loop Analogue addressable fire control Panel
High Sensitivity Smoke Detection
ECP Extinguishing Control Panel. Extinguishing Control Panel General overview Technical overview.
An Introduction to the R3 19 inch Rack The R3 control system comprises a number of different plug in modules, each of which is dedicated to a particular.
1.Overview 2. Hardware 3. Software Interface 4. Triggering 5. Installation 6. Configuring.
HP900 (ESP Protocol) Analogue Addressable Control Panels
Protecting life, environment and property… 1 AutroMaster 5000: Version 4.0 Operation ID: AM5000_operation_eng_
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
BOOT MODE 1 BOOT MODE 2 BIOS COMMUNICATION DEFAULT CONTROLLER INVERT RELAY OPERATION ENABLE COMM FAIL RELAY CONTROL RELAY OFF / ON COMM.
KIDDE FIRE PROTECTION Vega Peer to Peer Networking.
Intelligent Detection Systems l integrity of system confirmed continuously l pre-alarm facility l high flexibility of system configuration l performance.
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
2 December, 2015 New Conventional Fire Control Panel.
Xplorer 1-2 Loop Analogue Addressable Control Panels From 1-2 loops EN54 2 & 4 Compliance Fully compatible with all Apollo XP95 and Xplorer devices Extensive.
All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Europe & Africa More Than.
New Product Developments World Leaders in Combustion Management Solutions New Products New Products.
Quick guide to ASIMON configuration For version 3.0 or greater SAFETY AT WORK Date: 3/18/2009.
The Future is Now The IP Solution for Life Safety, Area of Refuge & Emergency Communications.
Display System for 6400/6300 Protec Alarm Control Systems. Series of Graphic Screens shows all Addressable Devices and their status indication Complicated.
FireClass Addressable FC501 Part 2 - Panel Use. FC501 Engineering 3 in 1 Loops Up to 400mA current dynamically shared across 3 loop circuits Two versions.
Puissant Panel User Training Esc.. 09:11:35 ACTIVE # * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE.
Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic.
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
Emergency Voice Communication System ‘beyond expectations’
Draft UniNet-ID Sales Training For ESD Sales People & Estimators.
Morley – IAS Fire Systems
C1300 advanced circular chart recorder
Feature Benefit Feature Benefit Feature Benefit Feature Benefit
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Presentation transcript:

6300

6300 System Features Interactive Digital Addressable Fire Detection and Alarm System. Designed for Small and Medium Sized Installations such as Nursing Homes Hotels and Offices Fully Conformant to EN54 Requirements Recessed Option Range of Finishes. Networkable (Up to 32 Panels) 1 , 2 and 4 Loop options. 191 Devices Per Loop

6300 System Features Controls and Displays. Silence/Sound Alarms/Reset/Accept 80 Character LCD Display Twin Fire LEDs 32 Zonal Fire LEDs Full Fault Monitoring LEDs Optional Low Noise Printer

6300 System Features

6300 Front display LCD display General fire LEDS Fire ZONE display Status LEDs Control buttons Thermal printer

6300 Status LEDs Fault - illuminates with a general fault. System fault - illuminated when the processor has failed. Alarm fault - problem with the internal alarm circuits. Fire link fault - problem with the fire station link Power-supply status - illuminated in a healthy condition (GREEN) Test - illuminates when the system is in engineers test mode. Pre-alarm - illuminates when a devices is approaching a fire condition Alarms disabled -sounders are isolated Fire link active -signal to the fire brigade active (if link fitted) Disablement - illuminates when a devices has been isolated. Fire link disabled - fire station link isolated

System Features LCD in a quiescent condition Lower line User Message Upper line Current time & date System Normal 20/1/09 15:35:31 ASM - HUNGARY Liquid Crystal Display - The 80, large character liquid crystal display will under normal quiescent conditions display the current time and date with the option to also display a 40-character user’s message such as the site name or installation company. In an alarm or fault condition the LCD will display the device Loop, address and Zone number and up to 40 characters of user definable location text, programmable on site using Protec 6300/WinTEXT windows based software. LCD in a fire condition Upper line Zone, Loop and address number Lower line User definable Location text Fire 01 of 01 Zone 32 Loop 1 address 191 Building 2, Ground Flr, East Wing Rm 12

6300 System Features Thermal Printer 40 Character On Demand Real Time Data for Fire and Fault Condition Prints Device Number and Location Text Prints Event Reports Prints Device Configuration Prints Programming Matrix Prints List of Devices becoming contaminated. Thermal Printer Fire in Zone 32 31/7/00 22:50:20 Loop 1 Address 191 Building 2, Ground Flr, East Wing Rm 12 Typical fire print-out

6300 Fire LEDs General fire LEDs 32 Fire ZONE LEDs

6300 Control buttons Accept - the fault buzzer to be muted (not all events) Previous -allows previous events or menu options to be selected. Next -allows the next event or menu options to be selected. Menu - allows access to the menu options. Sound alarms - activates all sounders on the system Silence - Allows all sounders to be silenced following either a fire or sound alarms event. Reset - allows the system to be fully reset following a fire event.

Maximum of 4 repeater / mimics from a Master 6300 6300 Standalone Maximum of 4 repeater / mimics from a Master 6300 6300 Master 6300 Repeater 6300 Mimic 6300 Repeater 6300 Repeater

Max Network distance NOT to exceed 8Km (5 miles) 2 Core network Max 32 x 6300 per Network 1 Km Max between Nodes Max Network distance NOT to exceed 8Km (5 miles)

6300 Network break Network break 3 & 4

X300 Software X300 WIN TEXT - Free software to allow client to write their own device text files (PC Only). X300 Engineer - software charged, to allow engineer to write their own program and download to control panel DONGLE PROTECTED.

Device Text Editor Device Text can be edited to suit the site layout A print out of the device text is available

Matrix X300 Matrix - The system cause and effects can be configured using the X300 WINPROG matrix editor. Outputs can be configured as alarm or control O/Ps Selectable Sound settings C&E program Overview shows the cause and effect for the whole system. Matrix delay setting set via ‘Timeouts’ editor Misc settings - refer to next slide Group text to detail C&E areas X300 setting refer to slide

Miscellaneous 24 non Latching Fire Devices and 24 latching non fire devices Pulse times for output groups Miscellaneous Keyswitch Inputs The walk test function allows access in User Menu

X300 Button Fire Link Delay allows delays on all individual devices or groups of devices The Fire Link output can be programmed for all of the options listed Different languages are supported Network Input Filtering allows a panel to display all events from chosen network panels Check the panel overlay Sensitivity Settings can be changed for individual devices or groups of devices The internal charger is the S9000 EN54 but external chargers can be utilised.

Device Editor Unique Serial Number Sensitivity settings are changeable. LOOP No Address No. Zone – Geographical Representation – up to 32 zones. Alt. display shows more options for the device. Input Group - 96 Output Group - 96 Reset Class resets the device to the default setting.

6400

6400 System Features Distributed Network System. Designed for Medium to Large sized buildings such as hotels, Offices, Universities and Hospital Sites. EN54 Compliant DCN (Display Control Node) LPN (Loop Processing Node) Distributed Loop and Sounder Wiring

6400 System Features 6400 DCN Accessed Via hinged Lockable Door Main Fire Lamps Quarter VGA Graphics LCD Display Backlit Zonal display UP TO 100 Zones Fault Lamps

6400 System Features 6400 DCN Sound Alarms, Silence, Accept and Reset Buttons Access to Menu Keys On demand Low Noise 40 Character Printer Qwerty Key Board

Location text displayed during fault & Fire

Alarm text displayed only for Fire

6400 System Features 6400 LPN Processes Loop Data Network Communication Implementation of Cause and Effects Sounder Circuitry Auxillary Changeover Contacts 127 devices per loop either 2 Loop (2LPN) or 4 loop (4LPN) Two Full Duplex RS232 Ports for Graphics and Programming 6400 LPN

6400 System Features & = 6400 DCN/LPN Combining DCN and LPN in single Point Enclosure. Combination gives fully functional system functions and controls in a stand alone panel. DCN/LPN often used as Master Panel for a fully networked system

all use the same Processor PCB RDN / LCD / Mimic The 6400 RCN, LCD and MIMIC all use the same Processor PCB

Repeat Display Node Menu / Select / Mute / Silence and Repeat Buttons Optional Printer Node on the Network Can be Combined with LPN

6400 LCD Repeater Listen Only Device Menu / Silent / Mute Buttons No System Controls Not a Node on the Network but sits on Network. Loop Powered version available.

Mimic Repeater Customised Illuminated Mimic Display LEDS activated by appropriate zone Node on Network Customised Control Options

6400 Secure Network Interconnects all Node Options All nodes are accessible from any 6400/DCN location. Wired as a loop. Dual Channel Fault Tolerant RS 485 No Single fault disables the system. Can act as Stand Alone Up to 99 Nodes on Network Wired as Copper or Fibre Optic

6400 Secure Network 99 NODES per NETWORK 2 CORE RS485 NETWORK 1 KM Max Single and Dual Break safety 99 NODES per NETWORK 1 KM Max

Graphics RS232 1 x GRAPHICS PER DCN MAX 20 Mtrs Windows Based Large Sites – Full Display and Control. Touch Screen option. Zoom Levels Event Logging System available RS232 1 x GRAPHICS PER DCN MAX 20 Mtrs

6400

6000 PLUS Sensors Temperature Optical Op/ht/co Op/Ht Low Profile Design Advanced Fire Sensing Technology Electronic Sounders High Intensity LED Warning Beacons Speech Enhanced Talking Sounder Semi Flush Option and Fast Fix Base. All Incorporated in to the Sensor Head Temperature Optical Op/ht/co Op/Ht

6000 PLUS Sensors Base Options Fast Fix Recessed Base. Standard Base

6000 PLUS Sensors Recessed Fast Fix Bases Step 1 Wire base to diagram shown. Fit and commission sensor, or leave sensor commissioning until after false ceiling is fitted. Step 4 Rotate screw covers to reveal screws. Step 2 Pull sensor/base combination, or base only through ceiling tile hole. (121mm dia) Step 5 Tighten screws until resistance is felt, and clamps have engaged ceiling tile. Do not overtighten Step 3 Push trim onto base. Rotate clockwise to lock trim in position. Push base back through false ceiling so trim is flat to ceiling. Step 6 Rotate screw covers back to original position.

Interactive Algo-Tec evaluates the data of each fire sensor and is able to learn from the information received. This may simply be to recognise that a sensor is becoming contaminated or in a dirty environment and to automatically increase the alarm threshold to compensate for the background levels (Threshold compensation). More complex Algo-Tec functions include the ability to discriminate between certain fire and non-fire conditions, filtering out certain environment stimuli, such as steam from a hotel bathroom, and increasing the sensitivity of a sensor (6000 plus OPHT) when an increase in temperature is detected. The net effect of the interaction between the sensors and the Algo-Tec decision making is enhanced performance, through immunity to false alarm and more responsive fire detection.

6000 Plus Sensors Optical Sensor • Heat Sensor & Optical Sensor • Dual Technology High Performance • Multi Criteria High Performance Optical Smoke, Heat and CO Sensor • Independent Channel Control • Day/Night Operation • Protec Algo-TecTM 6000PLUS Protocol • Devices Display Address Number • Easy To Address • FASTTM Addressing • Reduced False Alarms • Electronic Sounder • High Intensity LED Beacon • Voice Enhanced ‘Talking’ Sounder with selectable msgs Optical Sensor

6000 Plus Sensors Temp Sensor • Heat Sensor & Optical Sensor • Dual Technology High Performance • Multi Criteria High Performance Optical Smoke, Heat and CO Sensor • Independent Channel Control • Day/Night Operation • Protec Algo-TecTM 6000PLUS Protocol • Devices Display Address Number • Easy To Address • FASTTM Addressing • Reduced False Alarms • Electronic Sounder • High Intensity LED Beacon • Voice Enhanced ‘Talking’ Sounder with selectable msgs Temp Sensor

6000 Plus Sensors Op/Ht/Co Sensor • Heat Sensor & Optical Sensor • Dual Technology High Performance • Multi Criteria High Performance Optical Smoke, Heat and CO Sensor • Independent Channel Control • Day/Night Operation • Protec Algo-TecTM 6000PLUS Protocol • Devices Display Address Number • Easy To Address • FASTTM Addressing • Reduced False Alarms • Electronic Sounder • High Intensity LED Beacon • Voice Enhanced ‘Talking’ Sounder with selectable msgs Op/Ht/Co Sensor

6000 Plus Sensors Op/Ht Sensor • Heat Sensor & Optical Sensor • Dual Technology High Performance • Multi Criteria High Performance Optical Smoke, Heat and CO Sensor • Independent Channel Control • Day/Night Operation • Protec Algo-TecTM 6000PLUS Protocol • Devices Display Address Number • Easy To Address • FASTTM Addressing • Reduced False Alarms • Electronic Sounder • High Intensity LED Beacon • Voice Enhanced ‘Talking’ Sounder with selectable msgs Op/Ht Sensor

6000 / Beam

Loop Powered Sounder (2 wire) 6000 / SSR 2 Loop Powered Sounder (2 wire) No of addresses - 1 address No of Cables - 2 cables Alarm Current - 5 mA Quiescent Current - 0.5 mA DB Output - 101 dB (@ 1m) Colour - RED or White

6000 / ZAI Connections 6000 Loop 6000 Loop Max 1 amp Load Mains Supply Max 1 amp Load Max 20 x 3000 detectors 8k2 or 100uF EOL 10k EOL Alarm Circuit Detection Circuit

Volt free changeover contacts 6000 / Micco Connections 6000 Loop 6000 Loop NO switch 47K EOL Volt free changeover contacts 240 VAC (5amp)

Loop Test Unit Compatible with all current Protec 6000 series and 6000 plus Series devices Enables rapid confirmation of correct loop wiring Allows verification of correct number and type of loop devices User may activate a single output at a time Retrieves analogue values from devices Drives 6000PLUS talking sounders Robust construction Easy to read display Can be powered from mains (via supplied charger), or internal batteries

Bar-Codes documentation

Bar-code sticker removable Device Bar-Codes 2 x Removable Bar-codes Rear of 6000 Sensor Device Serial Number Bar-code sticker removable 1 x Fixed Bar-code

Bar-Codes documentation

Download of Serial Nos Serial Numbers entered into 6400 software editor program Device Serial number Bar-Code sticker Bar-Code Reader

(Remote Visual Address Verification) RVAV (Remote Visual Address Verification)

Advantages UK Manufacture – All Sensors and Panels made in same factory Fast Addressing – Saves time on site no Switches Identification - Devices can be traced via serial numbers etc. Combined Sensors – Optical/Heat and Optical/Heat/CO Integrated Sounders/LED Beacons/Talking Sounders/Isolators Systems - Small Medium and Large Systems catered for.