Hearing Aids and Hearing Impairments

Slides:



Advertisements
Similar presentations
Hearing and Deafness 1. Anatomy & physiology Chris Darwin Web site for lectures, lecture notes and filtering lab:
Advertisements

Perception Chapter 11: Hearing and Listening
Figures for Chapter 9 Prescription
Hearing Aids and Hearing Impairments Part II Meena Ramani 02/23/05.
An Update on Hearing Aid Testing
Verifying Open-Ear Fittings With Speech-Mapping
HEARING Sound How the Ears Work How the Cochlea Works Auditory Pathway
Hearing and Deafness 2. Ear as a frequency analyzer Chris Darwin.
Hearing and Deafness Outer, middle and inner ear.
Richard Baker University of Manchester
Pitch organisation in Western tonal music. Pitch in two dimensions Pitch perception in music is often thought of in two dimensions, pitch height and pitch.
HEARING WELL CLUB WHAT DOES YOUR AUDIOGRAM SAY ABOUT HEARING LOSS?
Desirable Properties in Modern Compression Schemes Challenges to Get the Best Out of Today’s Technology.
The nature of sound Types of losses Possible causes of hearing loss Educational implications Preparing students for hearing assessment.
Program.
Structure of human ear Understanding the processes of human auditory system are key for posting requirements for architectural acoustics. This gives us.
M.Sc. in Medical Engineering
Hearing Detection Loudness Localization Scene Analysis Music Speech.
HEARING MUSICAL ACOUSTICS Science of Sound Chapter 5.
Hearing and Deafness 1. Anatomy & physiology Chris Darwin Web site for lectures, lecture notes and filtering lab:
Fitting Formulas Estimate amplification requirements of individual patients Maximize intelligibility of speech Provide good overall sound quality Keep.
ANSI Overview Hearing Aid Testing and Verification What is ANSI?
TOPIC 4 BEHAVIORAL ASSESSMENT MEASURES. The Audiometer Types Clinical Screening.
Chapter 6: The Human Ear and Voice
Compression 101.
Applied Psychoacoustics Lecture 2: Thresholds of Hearing Jonas Braasch.
Mrs. Jameson ASL ANATOMY OF THE EAR Mrs. Jameson.
Figures for Chapter 6 Compression
Acoustics and Noise. Physics of Sound Sound is a response to pressure waves  = c = ° C in air Amplitude: Pressure [N/m 2 ] Intensity: Amplitude.
Hearing and Deafness Anatomy & physiology. Protection Impedance match Capture; Amplify mid-freqs Vertical direction coding Frequency analysis Transduction.
Meena Ramani 04/12/06 EEL 6586 Automatic Speech Processing.
Super Power BTE A great new Trimmer Family. The new & complete, fully digital Trimmer family ReSound is proud to introduce the complete new trimmer family,
BASIC OVERVIEW OF THE EAR AND HEARING LOSS The Ear.
KTH ROYAL INSTITUTE OF TECHNOLOGY Sound, the Auditory System, and Pitch Perception Roberto Bresin DT2350 Human Perception for Information Technology Copyright.
Audiograms How to read them and what they are.. Terms to know: Audiogram An audiogram is a means of recording the results of a hearing test. It will include.
Dynamic Range and Dynamic Range Processors
The Ear and How We Hear Notes on the EAR Ear is divided into three main sections:
Figures for Chapter 1 Introductory concepts
Physics Acoustics for Musicians
Airborne vs. bone conduction. Conduction hearing loss.
HEARING MUSICAL ACOUSTICS Science of Sound Chapter 5 Further reading: “Physiological Acoustics” Chap. 12 in Springer Handbook of Acoustics, ed. T. Rossing.
Analog vs. Digital “’A Hearing Perspective” Andy Raguskus, CEO SONIC innovations, Inc.
SOUND PRESSURE, POWER AND LOUDNESS MUSICAL ACOUSTICS Science of Sound Chapter 6.
IIT Bombay {pcpandey,   Intro. Proc. Schemes Evaluation Results Conclusion Intro. Proc. Schemes Evaluation Results Conclusion.
Loudness level (phon) An equal-loudness contour is a measure of sound pressure (dB SPL), over the frequency spectrum, for which a listener perceives a.
Hearing Sound and the limits to hearing Structure of the ear: Outer, middle, inner Outer ear and middle ear functions Inner ear: the cochlea - Frequency.
Prevalence and Causes of Hearing Loss. Prevalence of Hearing Loss Each year in the United States, more than 12,000 babies are born with a hearing loss.
Fundamentals of Sensation and Perception
EE Dept., IIT Bombay Workshop “Radar and Sonar Signal Processing,” NSTL Visakhapatnam, Aug 2015 Coordinator: Ms. M. Vijaya.
1 Sound Chapter The Nature of Sound Remember: -every sound is produced by an object that vibrates. -sound waves are compressional waves, which are.
SOUND PRESSURE, POWER AND LOUDNESS
HEARING MUSICAL ACOUSTICS Science of Sound Chapter 5 Further reading: “Physiological Acoustics” Chap. 12 in Springer Handbook of Acoustics, ed. T. Rossing.
대학원 생체신호처리 - 4 이상민.
The physics of hearing and other odds and ends. The range of human hearing The range of average human hearing is from about 15Hz to about 15,000Hz. Though.
Listen and Speak Clinic Hearing Aids in Pune
Hearing Loss and Hearing Aid Treatment Options
Saketh Sharma, Nitya Tiwari, & Prem C. Pandey
Hearing tests.
Loudness level (phon) An equal-loudness contour is a measure of sound pressure (dB SPL), over the frequency spectrum, for which a listener perceives a.
Loudness level (phon) An equal-loudness contour is a measure of sound pressure (dB SPL), over the frequency spectrum, for which a listener perceives a.
Audiograms Degree, Type and Configuration
Review: Hearing.
Loudness level (phon) An equal-loudness contour is a measure of sound pressure (dB SPL), over the frequency spectrum, for which a listener perceives a.
Mrs. Jameson ASL A Story About the Ear Mrs. Jameson.
Hearing, not trying out for a play
A Smartphone App-Based
Hearing Loss and Hearing Aid Treatment Options
Mrs. Jameson ASL A Story About the Ear Mrs. Jameson.
Fundamentals of Sensation and Perception
Fundamentals of Sensation and Perception
Presentation transcript:

Hearing Aids and Hearing Impairments Meena Ramani 02/21/05

Dramatic Decrease In Audibility & Intelligibility Original Speech 40dB conductive loss P. Duchnowski and P. M. Zurek, “Villchur revisited: Another look at automatic gain control simulation of recruiting hearing loss,” J. Acoust. Soc. Am., vol. 98, no. 6, pp. 3170-3181, Dec. 1995

Outline Facts on Hearing Loss Hearing Aids Cochlea-IHC and OHC Presbycusis Decreased Audibility Decreased Frequency Resolution Decreased Temporal resolution Decreased Dynamic Range Amplification Techniques Linear Compressive-Single/MultiBand

Facts on Hearing Loss in Adults One in every ten (28 million) Americans has hearing loss and the prevalence of hearing loss increases with age. While hearing aids can help about 95% (26 million) of them, only 6 million use hearing aids. WHY? Stigma associated with wearing a Hearing Aid (HA) Denial about one’s Hearing Loss (HL) Exorbitant cost (eg. A pair of Widex Senso Diva BTEs cost around $11,000) Current HAs do not meet user expectations

Hearing Aids- An Engineering perspective Area where vast improvement are possible 28 million Hearing Impaired people Huge Market($$$$) Circuit design and Signal processing personnel Circuit design: Low power: 1.3V Fast acting (delay < 10ms) Small size Lower cost Signal Processing: Biologically inspired/smarter algorithms Restore all effects of hearing impairment.

Anatomy of a Hearing Aid Microphone Tone hook Volume control On/off switch Battery compartment

Types of Hearing aids Behind The ear BTE In the Ear ITE Completely in the canal CIC In the Canal ITC

Cochlea-IHC and OHC Organ of corti: Inner Hair Cells (IHC) IHC/OHC 3 times more OHC Inner Hair Cells (IHC) Afferent <to brain> Outer Hair Cells (OHC) Efferent <from brain> Sharpen the traveling wave Provide an amplification for soft sounds(40-50 dB SPL) Damage in OHC/IHC Sensorineural Hearing Loss (SNHL) Currently we don’t sharpen the peak of the traveling wave OHCs are very mechanical..use a lot of oxygen…die first…mild-moderate loss..if IHC die then severe hearing loss Presbycusis

Presbycusis Type of Sensorineural Hearing Loss HL in aging ears; occurs due to damage in OHCs Mild 25-39 dBHL Moderate   40-68 dBHL Severe 70-94 dBHL Problems faced by people with presbycusis: Decreased Audibility Decreased Frequency Resolution Decreased Temporal resolution Decreased Dynamic Range

Decreased Audibility 90% of HI adults loose frequencies between 500Hz-4KHz HF components of speech (consonants) are weaker than the LFs. Loudness dominated by the LFs “Speech is loud enough but not clear enough!” To overcome this: HA has to provide more gain at HFs.

Decreased Frequency Resolution Asymmetry of traveling wave Eg. Reverse Audiogram OHCs do not sharpen the traveling wave. Decreases the ability to distinguish close frequencies Upward spread of masking low frequencies mask more than high frequencies Normals and HI: Poor resolution at high intensities To overcome this: HAs less gain at LFs Try to remove noise before entering HA. Beamforming

Decreased Temporal Resolution Intense sounds mask weaker sounds that immediately follow them. To overcome this: Fast acting compression <Problem: Changes the speech cues; decreases intelligibility though it increases audibility!>

Dynamic Range of Hearing The practical dynamic range could be said to be from the threshold of hearing to the threshold of pain Sound level measurements in decibels are generally referenced to a standard threshold of hearing at 1000 Hz for the human ear which can be stated in terms of sound intensity: Equal Loudness Contours

Decreased Dynamic Range/Recruitment SNHL increases threshold of hearing much more than the threshold of pain; thus decreases the Dynamic Range of the ear. To overcome this: HA has to provide Compression; cut down amplification as sound gets louder.

Decreased Dynamic Range/Recruitment Figure 7.1. Typical loudness growth functions for a normal-hearing person (solid line) and a hearing-impaired person (dashed line). The abscissa is the sound pressure level of a narrowband sound and the ordinate is the loudness category applied to the signal. VS, very soft; S, soft; C, comfortable; L, loud; VL, very loud; TL, too loud. Figure 7.2. The response of a healthy basilar membrane (solid line) and one with deadened outer hair cells (dashed line) to best-frequency tone at different sound pressure levels (replotted from Ruggero and Rich 1991).The slope reduction in the mid-level region of the solid line indicates compression; this compression is lost in the response of the damaged cochlea.

Linear Amplification Figure 7.3. Loudness growth functions for a normal-hearing listener (solid line), a hearing-impaired listener wearing a linear hearing aid (short dashed line), and a hearing-impaired listener wearing a compression hearing aid (long dashed line with symbol). HA wearer adjusts gain, using volume control, as the level of environment changes.

Compressive Amplification Slope=1/Compression Ratio Imitates compression carried out by OHCs Fast Acting/Syllabic Compression: Attack time~5ms Release time~60ms Choose release time To avoid distortion To normalize loudness from phoneme to adjacent phoneme for syllabic compression Figure 7.4. Typical input-output function of a compression hearing aid measured with a pure tone stimulus at multiple levels. The function depicted shows linear operation at low and high input levels, and 3 : 1 compression at mid-levels. Different compression hearing aids have different compression ratios and different levels over which compression occurs.

Time Constants: Overshoot and Undershoot Affects Intelligibility Makes consonants be identified as plosives Reduce effects: Clipping overshoot Delaying gain Undershoot: When release time isn't that large, then forward masking lowers the affect of undershoot Figure 7.5. A demonstration of the dynamic behavior of a compressor. Top: Level of the input signal Middle: Gain that will be applied to the input signal for 3 : 1 compression, incorporating the dynamics of the attack and release time constants. Bottom: The level of the output signal, demonstrating overshoot (at 0.05 second) and undershoot (at 0.15 second).

Singleband/Wideband Adjust gain across all frequencies equally Preserves spectral shape over short time scales; speech cues Choose gain based on highest level; Spectral peak Speech has multiple spectral peaks. Inadequate selection of gains. Figure 7.7. Amount of compression applied to music by a wideband compressor (squares) and a multiband compressor (circles).The compression was measured by comparing the peak/root mean square (rms) ratio of the music into and out of the compressor over different frequency regions. The open symbols on the left show the compression ratio calculated from the change to the broadband peak/rms ratio. The filled symbols show the change to the peak/rms ratio in localized frequency regions.

Multiband Compressor Normally upto 20 bands are used with varying compression ratio per band. Adjust gain/compression in each band independent from other Change in spectral contrast across bands may cause perceptual consequences though it restores normal loudness. STI<Speech Intelligibility Measure> of compressed speech does not correlate to Listening tests. With more experience people who use multiband HAs get adjusted to the change in spectral shape/cues. Typically vowel perception is not affected as much as consonant perception Overamplification occurs at crossover between bands<To avoid this increase overlap between bands so that gain at a frequency is controlled by more than 2 bands>