Energy Performance Certificates

Slides:



Advertisements
Similar presentations
Day Topic: Finish Convection, Begin Radiation
Advertisements

Building Energy Rating
IX. REDUCING GREENHOUSE TEMPERATURE A. temperature regimes –range deg, stress above 90 deg.
Tas seminar/demonstration on Part L 2006 of the Building Regulations Presented by Alan Jones EDSL February
The Three Tiered Philosophy
Heating Ventilating And Cooling Sustainable Design Strategies
The Portland Street Building Back to “Select a building” Back to “Select a building” NatVent Presentation of the building Presentation of the building.
Sustainable Hotel Design Group 5 Presentation 4 Demand/Supply Matching.
ATA Melbourne Branch presentation April 2008 Jim Lambert
Chapter 5: Designing for Heating and Cooling 5.1 Organizing the problem a) Fenestration How much is optimum for the building? What should the form of the.
BRE Energy Efficient Office of the Future
Eurocode 1: Actions on structures – Part 1–2: General actions – Actions on structures exposed to fire Part of the One Stop Shop program Annex B (informative)
Ventilation Effectiveness & Indoor Air Quality Douglas Spratt February 2001.
1 ISAT Module III: Building Energy Efficiency Topic 6:Stead-State Building Loads z Fabric Loss z Ventilation Loss z Environmental Temperature z Steady-State.
Passive Cooling. Natural Ventilation Air Cooling Shades.
Building Australia’s Future Energy Efficiency Introductory Awareness Training AUSTRALIAN Greenhouse Office Supported by: Step by Step Application of BCA.
Buildings and Structures 2 Natural and Mechanical Ventilation.
Aperture Placement & Area. Aperture Refers to any daylight source – Windows – Skylights – Openings – Transparent or translucent surfaces Placement and.
Lesson 3 How does radon enter a home?. Slide 4-1 Predicted average indoor radon levels (U.S.) This map cannot be used to determine the radon level of.
Tools for Integrated Design ID seminar October Christian Hviid Industrial PhD-student Birch & Krogboe.
The Air We Breathe - Indoor Air Quality and Natural Ventilation Dr Yuguo Li Associate Professor Department of Mechanical Engineering The University of.
Thermal Management Solutions from APW President Systems
 Site  Requirements  Local Resources  Initial layout ideas  Brief material selection  Supply options.
Ventilation for Confined Spaces requires ventilation as follows: An employee may not enter the space until the forced air ventilation has eliminated.
Passive Technologies and Other Demand-Side Measures.
By Emmi Miller and Jenny Sulouff
Passive Heating. Uses the energy from the sun to keep occupants comfortable without the use of mechanical systems.
Building promoter: PROBAM nv Architect: Declercq E. The Keppekouter project Design issue Design issue Major findings Major findings Keppekouter building.
NatVent Architect: KHR A/S BRF Kredit headquarters Back to “Select a building” Back to “Select a building” Presentation of the building Presentation of.
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
Ventilation for Low Energy Buildings
The Velux Building NatVent Presentation of the building Presentation of the building The design issue The design issue The building concept The building.
PASSIVE HOUSING By Serena Mehta Passive housing or Passivhaus  “A Passivhaus is a building, for which thermal comfort can be achieved solely by.
The Town Hall of Zevenhuizen S.H. Liem, A.H.C. van Paassen M.Verwaal, H.F. Broekhuizen Delft, April 1998 Presentation of the building Presentation of the.
The European Office Building S.H. Liem, A.H.C. van Paassen M.Verwaal, H.F. Broekhuizen Delft, April 1998 S.H. Liem, A.H.C. van Paassen M.Verwaal, H.F.
Low Energy Building Design Presentation 1- Regulations Marc Smeed Edmund Tsang Graham Dow.
Windows and Doors. Typically once the roofing material has been installed/completed the windows and doors are installed. It’s important to install these.
The Renson Headquarters Renovation issue Renovation issue Major findings Major findings The RENSON- The RENSON- Headquarters More information... More information...
The EWZ building Presentation of the building Presentation of the building The design issue The design issue The building concept The building concept.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
NatVent WindowMaster Building Back to “Select a building” Back to “Select a building” Presentation of the building Presentation of the building Ventilation.
Air Movement and Natural Ventilation
Energy conservation strategies Buildings energy consumption depends on building envelop, efficiency of HVAC and lighting systems, amount of required fresh.
The Basler building The Basler building is situated in the city centre of Basel. This 10 storey, naturally- ventilated building, was built in The.
Site Location: Site Location: Gap Site at Bath Street and Pitt Street Plot: Plot: 50m x 50m Building Area: Building Area: 4000m 2 maximum Building Height:
Some Pointers for your assignment..  Passive solar heating is defined as using solar energy incident on windows, skylights, greenhouses, clerestories,
Building Envelope. Physical separator between interior and exterior spaces – Walls – Floors – Roofs – Fenestrations (any opening in the structure) – Doors.
4. INTERIOR LAYOUT  Good interior layout will facilitate many of the passive strategies recommended in this toolkit, in particular thermal mass, lighting.
Natural Ventilation Ar. Medha Deshmukh. Masters in Environmental Architecture.
Windows and doors Why do we have windows? – Light – Ventilation – Beauty – Energy (heat and cold, in and out) – View, etc.
Natural Ventilation. Natural Ventilation can found in any old building that doesn’t have any HVAC systems. Natural ventilation is able to provide a space.
VENTILATION AND FENESTRATION
GCSE ENERGY; THERMAL ENERGY TRANSFER 2
8. VENTILATION  When there is a difference between outdoor and indoor temperature, ventilation can be accomplished by natural means. Strategically placed.
VENTILATION AND AIR CONDITIONING Under the Subject Industrial Safety and Environment || ||
Unit 2: Chapter 2 Cooling.
Air Distribution Control
GREEN BUILDING MODEL Prashant Motwani (13MST0021)
Lesson 24 NATURAL CIRCULATION
Bell work Predict whether leaving the refrigerator door open on a hot summer day will help to cool the kitchen.
CHAPTER 3 VENTILATION.
. Level 3 Air Conditioning Inspections for Buildings 15. User Controls
Eurocode 1: Actions on structures –
Heat Loss and Gain Heat Loss and Gain
ATA Melbourne Branch presentation April 2008 Jim Lambert
5508BESG Services and Utilities Lecture 5
Smokes extraction principle
Presentation transcript:

Energy Performance Certificates Natural Ventilation PRESENTED BY

Ventilation Strategies Naturally ventilated buildings typically use less than half the energy of air conditioned buildings, and reduce capital costs by some 15 percent, and associated maintenance costs. Natural ventilation is also proven to improve occupant performance and reduce incidence of Sick Building Syndrome. (The Enviromental Illness Resource)

Ventilation Strategies Ventilation can be provided in a number of different ways, but each method can be categorized as either a natural ventilation system, a mechanical system or a combination of the two. The choice of ventilation systems is largely dependent on the following factors: • Predicted heat gains to the space. • Occupant usage patterns. • External noise levels and air quality. • The need to remove contaminated air. Natural ventilation is basically air that enters a building by natural means such as temperature difference and/or wind.

Ventilation Strategies The most basic natural ventilation system is the provision of openable windows. Windows can cause localized discomfort zones due to draughts and cold radiation in winter, or solar gain in summer. Occupants of naturally ventilated buildings with openable windows are generally willing to accept a wider range of internal temperatures than occupants of air-conditioned buildings with sealed windows.

Ventilation Strategies Windows with a large opening area provide the best summer ventilation, but large glazed areas can cause excessive overheating due to solar gain. Large window areas can also result in excessive glare, leading to the use of blinds and artificial lighting on bright days. A well designed and positioned window should allow adequate ventilation on warm, breezy days without causing unwanted draughts in the work area. Windows with an upper fanlight are well suited to this task.

Ventilation Strategies The problem of draughts and excessive heat loss caused by opening windows during the winter months can be avoided by the provision of trickle vents in the window frame. These are small weatherproof openings which maintain a low ventilation rate. Window mechanisms which can be finely set provide a useful addition to trickle vents during the spring and autumn when supplementary ventilation may be required. Friction stays on side and top-hung casement windows are particularly good in this respect.

Ventilation Strategies The use of powered window actuators enables multiple windows and other ventilation openings to be controlled as part of an automatic control strategy, such as a building management system (BMS). Manual control is also possible by means of push-button switches or hand-held infrared remote controls. Automatic control can be achieved in response to a range of parameters such as Internal and external temperature Wind speed and direction Solar gain Rain Air quality

Ventilation Strategies Single-sided ventilation Stale warm a air out Fresh air in Single-sided ventilation describes a space primarily ventilated by wind entering one or more openings within a single external wall. On days when there is little or no wind, limited ventilation is still possible if windows have top and bottom openings. This will enable convection currents in the space to expel warm air through the top opening and draw fresh air in at the bottom (known as stack ventilation). Large vertical openings are also effective, such as a horizontal sliding sash window.

Ventilation Strategies Cross ventilation Fresh air Stale, warm air Cross ventilation is a very effective way to achieve a high rate of ventilation and can be used in relatively deep-plan offices. Wind drives air through open windows on the windward side of the building and open windows on the opposite side allow stale air to escape.

Ventilation Strategies Stack Ventilation Stack ventilation describes the process of buoyant, warm air rising upwards in a building and exiting through one or more high-level openings. The air displaced from the building causes cooler fresh air to be drawn into the building through low-level openings, such as windows, and doors. The main benefit of stack ventilation is that the temperature difference between the inside and outside of a building is the driving force and can therefore provide ventilation on hot still days when there is little or no wind

Ventilation Strategies Night Cooling Night cooling refers to the operation of natural ventilation at night to purge excess heat from occupied spaces. It also uses the lower external temperature to reduce the temperature of the building fabric. A building with sufficient thermal mass that can be exposed to night time ventilation can reduce peak internal temperatures by 2-3°C. Night cooling offers the potential to minimise reliance on air conditioning and improve the internal conditions in naturally ventilated buildings. Good control of night cooling is required in order to achieve maximum free cooling whilst avoiding overcooling and subsequent re-heating or thermal discomfort the following day.

Ventilation Strategies Mixed-mode ventilation Mixed mode is a term that describes a system which combines natural and mechanical ventilation. The mechanical element can be extract, supply or a combination of the two, however it is typically a supply system. The mechanical element ensures that an adequate air flow is maintained when natural ventilation is inadequate. This is particularly useful at night when it can be used to purge heat from the building in readiness for the next day.

Local Mechanical Exhaust Follow LATEST Conventions Example Toilet – 2m high x 1m wide x 3m long 6m3 x 1000 = 6000 Litres x 10 Air Changes/Hour 60,000 Litres/Hour / 3600seconds (in an hour) 16.666 l/s divide by 3m length Equals 5.5 l/s/m2