VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.

Slides:



Advertisements
Similar presentations
Fire Behaviour Ventilation. Aim To provide students with information to give them an understanding of the behaviour of fire.
Advertisements

Chemical Fume hood or Biosafety Cabinet
AIR DISTRIBUTION (Additional information. Also see Chapter 18) General The proper delivery of air for heating, cooling, or ventilation is a crucial part.
Recirculated and Replacement Air
(Control of Substances Hazardous to Health Regulations,2004)
Production planning An Introduction to CoSHH (Control of Substances Hazardous to Health Regulations,2004)
An Introduction to CoSHH
Ventilation Systems As Control Measures. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit.
OSHA’s Respiratory Protection Standard 29 CFR
Welding, Cutting, & Burning. GENERAL HAZARDS General hazards of welding include: –Impact –Penetration –Harmful dust –Smoke –Fumes –Heat –Light radiation.
Local Exhaust Hoods. 2 Introduction:  Designed to capture and remove harmful emissions from various processes prior to their escape into the workplace.
BASIC PRINCIPLES IN OCCUPATIONAL HYGIENE
Zettl Group Safety Talk ~Fume Hoods~ 09/28/06 Takashi Ikuno.
EARLIER KITCHENS PRESENT DAY KITCHEN Common misconceptions of kitchen ventilation. In a commercial kitchen the prime concern of the owners, designers,
LOCAL EXHAUST VENTILATION …study of the principles associated with proper application of local exhaust ventilation (LEV) for control of airborne contaminants.
Presented on Behalf of The: Barbados Association of Professional Engineers by: Eng.: Dev Maharaj.
Passive Cooling. Natural Ventilation Air Cooling Shades.
Chemical Fume Hood  A type of local ventilation device that is designed to limit the user's exposure to hazardous or noxious fumes, vapors or dusts.
The gasses, fumes and dust produced by welding and cutting processes can be hazardous. There are 3 basic methods to protect personnel against hazardous.
Buildings and Structures 2 Natural and Mechanical Ventilation.
Introduction to heat Is this heat? When I touch it, it burns me. I can feel the heat at a distance The hot gases rise.
Spray Finishing Operations/Spray Booth March 9, 2009.
Industrial Ventilation - A major control measure Dr. AA, UTM.
Unit 6.2. Mechanical and mixed mode ventilation TB Infection Control Training for Managers at National and Subnational Level.
Control of Work Environment Hazards
General Ventilation General ventilation dilutes the concentration of the solvent in the air of a room or space. When small amounts of solvents are used.
HOT WORK PROCEDURES Welding and Hot Work, such as brazing or grinding present a significant opportunity for fire and injury. CCR Title 8 Sub Chapter 7,
Part 2 - Dilution Ventilation (General Ventilation)
Enclosure Fire Dynamics
Placing Vapor Distribution Systems and Appliances into Operation MODULE 5 Validating Combustion Air.
Welding Fumes and Gasses
Ventilation for Confined Spaces requires ventilation as follows: An employee may not enter the space until the forced air ventilation has eliminated.
Local Exhaust Ventilation
TRI MARTIANA.  A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants such as dust, fumes,
Indoor Air Quality Trina Redford Industrial Hygienist National Naval Medical Center IH Services North.
Saving Ventilation Dollars A Look at Economics of Ventilation.
HAZARD COMMUNICATION STANDARD HAZARD COMMUNICATION STANDARD Employees are: Informed of the Hazardous Chemicals in your workplace. Trained to work safely.
Unit 6.4. Filtration TB Infection Control Training for Managers at National and Subnational Level.
Air Quality Controls Engineering Controls Administrative Controls Personal Protective Equipment.
Eliminating and Controlling Dust & Noise Hazards July 2002.
Anhydrous Ammonia Emergency Preparedness v Information from the 2012 Emergency Response Guidebook v ID # 1005 v Guide # 125 v Name of Material Anhydrous.
Job Safety Analysis (JSA)
RESPIRATOR REFERENCES
Hot Work Procedures Fire Control. Cutting and Welding Where practicable all combustibles shall be relocated at least 35 feet from the work site Where.
Air Movement and Natural Ventilation
Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy’s National Nuclear.
انتظار میرود دانشجو در پایان جلسه بتواند: 1- اصول تهویه صنعتی را بیان کند. 2- اهداف تهویه صنعتی را شرح دهد. 3- تفاوت تهویه صنعتی و تهویه مطبوع را بیان.
Tyson Burt Mathieu Gagnon
PRINCIPLES OF CONTROL ...a discussion of the strategies and methods available to achieve control of health hazards.
AIR HANDLING SYSTEM © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Integrated Science 11 CMH Ventilation CREATED BY: Reynaldo Thomas.
VENTILATION AND FENESTRATION
PPT Basic Ventilation Bureau of Workers’ Compensation PA Training for Health & Safety (PATHS)
Health and Safety Unit 3 Sophie Bevan. COSHH What does it stand for? ‘The Control of Substances Hazardous to Health’ Regulations (2002) What does it.
Hierarchy of Hazard Control
VENTILATION AND AIR CONDITIONING Under the Subject Industrial Safety and Environment || ||
HAZARD CONTROL HIERARCHY
Prevention and Control of Influenza A (H1N1) in the Workplace Engr. Nelia G. Granadillos Chief, Environment Control Division Occupational Safety and Health.
Industrial Ventilation
CHAPTER 8 Ventilation.
BASIC PRINCIPLES IN OCCUPATIONAL HYGIENE
(Modified from University Of South Carolina)
BUILDING HEATING AND COOLING
Controlling Chemical Hazards
CHAPTER 3 VENTILATION.
An Introduction to CoSHH
Welding Fumes and Gasses
IMPORTANT NOTE TO CONSTRUCTION MANAGERS
Hot Work Procedures Fire Control.
Presentation transcript:

VENTILASI TRI MARTIANA

Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants such as dust, fumes, mists or vapours. Substitution or enclosure method Simple, cheap and effective

Types of Ventilation  Natural  General  Dilution  LEV

Natural Ventilation Natural movement of air entering and leaving openings such as windows, doors, roof ventilators as well as through cracks and crevices of a building Heated air rises, cool air below

General Ventilation A method of improving or maintaining the quality of air in the work environment with airflow A room or an entire building is flushed by supplying and exhausting large volumes of air throughout the area 1.Supply or forced ventilation 2. Exhaust or induced ventilation

Dilution Ventilation (DV) DV consists of general ventilation Uncontaminated outside air + inside air = diluting and reducing the concentration of air contaminants to acceptable levels to which a worker can be safely exposed for eight hours a day

LEV Capture or contain contaminants at their source before they escape into the work room environment System consists of one or more hoods, ducts, air cleaner and a fan LEVs remove contaminants rather than just dilute them

Use of Natural Ventilation Not suitable for processes which emit dust, fumes, mists or gas Rooms for chemical storage + 25% of floor area Half the ventilating area should be between floor level and a height of 2.25m from the floor

Use of Dilution Ventilation DV is usually applied to the control of contaminants in situation meeting these criteria: To control vapours (+organic) from low toxicity solvents To control contaminants released over such a large area or in such a manner that LEV is impossible, impractical or prohibitively expensive

Small quantities of contaminants released into the work room Rate of contaminant release should be reasonably constant to avoid inadequate dilution during periods of peak contaminant release No corrosion or other problems from the diluted contaminants in the work room air

Sufficient distance from the worker to the contaminants source to allow dilution to safe levels

DV is prohibited – control emission of very toxic air contaminants e.g., formaldehyde or other carcinogenic chemicals For effective DV, the exhaust outlet and air supply must be so located that all the air employed in the ventilation passes through the zone of contamination

Avoid re-entrance of the exhausted air. The advantages and disadvantages of DV are as follows:

Advantage Disadvantage Simplicity Low original cost Large volumes of dilution air needed Employee exposures are difficult to control near source

Use of LEV The most effective means of controlling air contaminants is to capture and remove the air contaminants at their source with LEV and to prevent them from being carried away by air currents into the breathing zones of the worker

Major release (toxic) of localized sources of contaminants. LEV consists of 4 parts: 1.Hoods (most important) 2.Ducts 3.Air cleaner device 4.Fan and motor

High pressure Venturi

The hood consists of 3 main types to contain and remove the air-borne contaminants. 1.Enclosures 2.Capturing hoods 3.Receiving hoods

Conclusion Ventilation – an effective way to control toxic air contaminants if substitution or enclosure method of control is not possible DV reduces contaminant concentrations by diluting them with fresh air. (not for toxic emission)

LEV capture or contain contaminants at their source before they are dispersed in the workroom LEVs need to be maintained, inspected and tested regularly to ensure that it is performing adequately

Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants such as dust, fumes, mists or vapours. Substitution or enclosure method Simple, cheap and effective

Types of Ventilation  Natural  General  Dilution  LEV

Natural Ventilation Natural movement of air entering and leaving openings such as windows, doors, roof ventilators as well as through cracks and crevices of a building Heated air rises, cool air below

General Ventilation A method of improving or maintaining the quality of air in the work environment with airflow A room or an entire building is flushed by supplying and exhausting large volumes of air throughout the area 1.Supply or forced ventilation 2. Exhaust or induced ventilation

Dilution Ventilation (DV) DV consists of general ventilation Uncontaminated outside air + inside air = diluting and reducing the concentration of air contaminants to acceptable levels to which a worker can be safely exposed for eight hours a day

LEV Capture or contain contaminants at their source before they escape into the work room environment System consists of one or more hoods, ducts, air cleaner and a fan LEVs remove contaminants rather than just dilute them

Use of Natural Ventilation Not suitable for processes which emit dust, fumes, mists or gas Rooms for chemical storage + 25% of floor area Half the ventilating area should be between floor level and a height of 2.25m from the floor

Use of Dilution Ventilation DV is usually applied to the control of contaminants in situation meeting these criteria: To control vapours (+organic) from low toxicity solvents To control contaminants released over such a large area or in such a manner that LEV is impossible, impractical or prohibitively expensive

Small quantities of contaminants released into the work room Rate of contaminant release should be reasonably constant to avoid inadequate dilution during periods of peak contaminant release No corrosion or other problems from the diluted contaminants in the work room air

Sufficient distance from the worker to the contaminants source to allow dilution to safe levels

DV is prohibited – control emission of very toxic air contaminants e.g., formaldehyde or other carcinogenic chemicals For effective DV, the exhaust outlet and air supply must be so located that all the air employed in the ventilation passes through the zone of contamination

Avoid re-entrance of the exhausted air. The advantages and disadvantages of DV are as follows:

Advantage Disadvantage Simplicity Low original cost Large volumes of dilution air needed Employee exposures are difficult to control near source

Use of LEV The most effective means of controlling air contaminants is to capture and remove the air contaminants at their source with LEV and to prevent them from being carried away by air currents into the breathing zones of the worker

Major release (toxic) of localized sources of contaminants. LEV consists of 4 parts: 1.Hoods (most important) 2.Ducts 3.Air cleaner device 4.Fan and motor

High pressure Venturi

The hood consists of 3 main types to contain and remove the air-borne contaminants. 1.Enclosures 2.Capturing hoods 3.Receiving hoods

Conclusion Ventilation – an effective way to control toxic air contaminants if substitution or enclosure method of control is not possible DV reduces contaminant concentrations by diluting them with fresh air. (not for toxic emission)

LEV capture or contain contaminants at their source before they are dispersed in the workroom LEVs need to be maintained, inspected and tested regularly to ensure that it is performing adequately