Tier 1A Storage Procurement 2001/2002 Andrew Sansum CLRC eScience Centre.

Slides:



Advertisements
Similar presentations
Storage Procurements Some random thoughts on getting the storage you need Martin Bly Tier1 Fabric Manager.
Advertisements

Managing A Large Farm: CSF Andrew Sansum 26 November 2002.
ChooseIT and SetIT up An introduction to purchasing your computer and installing your Desktop or Laptop.
A CASE FOR REDUNDANT ARRAYS OF INEXPENSIVE DISKS (RAID) D. A. Patterson, G. A. Gibson, R. H. Katz University of California, Berkeley.
Hard Disk Drives Chapter 7.
RAID (Redundant Arrays of Independent Disks). Disk organization technique that manages a large number of disks, providing a view of a single disk of High.
NAS vs. SAN 10/2010 Palestinian Land Authority IT Department By Nahreen Ameen 1.
Operating Systems ECE344 Ashvin Goel ECE University of Toronto Disks and RAID.
Martin Bly RAL CSF Tier 1/A RAL Tier 1/A Status HEPiX-HEPNT NIKHEF, May 2003.
SAN Last Update Copyright Kenneth M. Chipps Ph.D. 1.
Reliability Week 11 - Lecture 2. What do we mean by reliability? Correctness – system/application does what it has to do correctly. Availability – Be.
NFS Tricks and Benchmarking Traps Daniel Ellard and Margo Seltzer FREENIX June 12, 2003.
Chapter 3 Chapter 3: Server Hardware. Chapter 3 Learning Objectives n Describe the base system requirements for Windows NT 4.0 Server n Explain how to.
Hard Disk Drives. ATA is the current standard, it uses regular molex power connectors and IDE cables. SATA is a newer product (also SATA2 is already in.
© 2009 IBM Corporation Statements of IBM future plans and directions are provided for information purposes only. Plans and direction are subject to change.
Challenges choosing storage systems for experimental data Nick Rees.
Data Storage Willis Kim 14 May Types of storages Direct Attached Storage – storage hardware that connects to a single server Direct Attached Storage.
Secondary Storage Unit 013: Systems Architecture Workbook: Secondary Storage 1G.
Lecture 33: Chapter 5 Today’s topic –Cache Replacement Algorithms –Multi-level Caches –Virtual Memories 1.
BACKUP/MASTER: Immediate Relief with Disk Backup Presented by W. Curtis Preston VP, Service Development GlassHouse Technologies, Inc.
Sponsored by: PASS Summit 2010 Preview Storage for the DBA Denny Cherry MVP, MCSA, MCDBA, MCTS, MCITP.
Storage Survey and Recent Acquisition at LAL Michel Jouvin LAL / IN2P3
XP Practical PC, 3e Chapter 17 1 Upgrading and Expanding your PC.
1 Chapter Overview CD-ROM and DVD Drives Advanced Hard Disk Drives SCSI Drives.
Day 10 Hardware Fault Tolerance RAID. High availability All servers should be on UPSs –2 Types Smart UPS –Serial cable connects from UPS to computer.
Terabyte IDE RAID-5 Disk Arrays David A. Sanders, Lucien M. Cremaldi, Vance Eschenburg, Romulus Godang, Christopher N. Lawrence, Chris Riley, and Donald.
1 Some Management Issues. 2 Scope  Procurement  Contracts  Legal.
Chromium OS is an open-source project that aims to build an operating system that provides a fast, simple, and more secure computing experience for people.
How to buy a PC Brad Leach David Howarth James Sawruk Andrew U.
XP Practical PC, 3e Chapter 18 1 Buying a PC. XP Practical PC, 3e Chapter 18 2 Buying a PC In this Chapter, you will learn: –Where to begin looking for.
Savings and Investment Unit Project Student Name.
CERN IT Department CH-1211 Genève 23 Switzerland t Experience with Windows Vista at CERN Rafal Otto Internet Services Group IT Department.
CASPUR Site Report Andrei Maslennikov Lead - Systems Karlsruhe, May 2005.
1 Selecting LAN server (Week 3, Monday 9/8/2003) © Abdou Illia, Fall 2003.
Comparing Disk Benchmark Tools Chris Brew FNAL. Why? We are about to start testing a number of Storage Solutions We are about to start testing a number.
Martin Bly RAL Tier1/A RAL Tier1/A Report HepSysMan - July 2004 Martin Bly / Andrew Sansum.
IT253: Computer Organization
1/14/2005Yan Huang - CSCI5330 Database Implementation – Storage and File Structure Storage and File Structure.
RAL Site Report Andrew Sansum e-Science Centre, CCLRC-RAL HEPiX May 2004.
IST Storage & Backup Group 2011 Jack Shnell Supervisor Joe Silva Senior Storage Administrator Dennis Leong.
JLAB Computing Facilities Development Ian Bird Jefferson Lab 2 November 2001.
Performance tests of storage arrays Irina Makhlyueva ALICE DAQ group 20 September 2004.
Chapter 12 – Mass Storage Structures (Pgs )
D ISCOVERING IDE D EVICES. IDE OVERVIEW The hard drive controller is responsible for converting signals made by the system CPU to signals that the hard.
Disk Interfaces Last Update Copyright Kenneth M. Chipps Ph.D. 1.
Tier1 Andrew Sansum GRIDPP 10 June GRIDPP10 June 2004Tier1A2 Production Service for HEP (PPARC) GRIDPP ( ). –“ GridPP will enable testing.
Phase II Purchasing LCG PEB January 6 th 2004 CERN.ch.
IDE disk servers at CERN Helge Meinhard / CERN-IT CERN OpenLab workshop 17 March 2003.
Tier1A Status Andrew Sansum 30 January Overview Systems Staff Projects.
RAL Site report John Gordon ITD October 1999
RAL Site Report John Gordon HEPiX/HEPNT Catania 17th April 2002.
ISCSI. iSCSI Terms An iSCSI initiator is something that requests disk blocks, aka a client An iSCSI target is something that provides disk blocks, aka.
STORAGE ARCHITECTURE/ MASTER): Disk Storage: What Are Your Options? Randy Kerns Senior Partner The Evaluator Group.
Linux IDE Disk Servers Andrew Sansum 8 March 2000.
STORAGE ARCHITECTURE/ MASTER): Where IP and FC Storage Fit in Your Enterprise Randy Kerns Senior Partner The Evaluator Group.
Tier1A Status Martin Bly 28 April CPU Farm Older hardware: –108 dual processors (450, 600 and 1GHz) –156 dual processor 1400MHz PIII Recent delivery:
RALPP Site Report HEP Sys Man, 11 th May 2012 Rob Harper.
A UK Computing Facility John Gordon RAL October ‘99HEPiX Fall ‘99 Data Size Event Rate 10 9 events/year Storage Requirements (real & simulated data)
The RAL Tier-1 and the 3D Deployment Andrew Sansum 3D Meeting 22 March 2006.
1 CEG 2400 Fall 2012 Network Servers. 2 Network Servers Critical Network servers – Contain redundant components Power supplies Fans Memory CPU Hard Drives.
RAID Presentation Raid is an acronym for “Redundant array of independent Drives”, or Redundant array of inexpensive drives”. The main concept of RAID is.
Dave Newbold, University of Bristol14/8/2001 Testbed 1 What is it? First deployment of DataGrid middleware tools The place where we find out if it all.
10/18/01Linux Reconstruction Farms at Fermilab 1 Steven C. Timm--Fermilab.
CERN Disk Storage Technology Choices LCG-France Meeting April 8 th 2005 CERN.ch.
Bernd Panzer-Steindel CERN/IT/ADC1 Medium Term Issues for the Data Challenges.
CMSC 611: Advanced Computer Architecture
Integrating Disk into Backup for Faster Restores
DSS-G Configuration Bill Luken – April 10th , 2017
Experiences and Outlook Data Preservation and Long Term Analysis
Focus on your business, Not File Storage:
Presentation transcript:

Tier 1A Storage Procurement 2001/2002 Andrew Sansum CLRC eScience Centre

Purpose of Talk To make available experience gained during the 2001 Tier1A procurement Thanks to the Tier 1 Procurement team: Roger Barlow, John Gordon, Roger Jones, Dave Kelsey, Ian MacArthur, Dave Newbold

Procurement Objectives Obtain at least 40TB of disk capacity –Simple and reliable - no surprises –Professionally built/installed –Linux O/S installed/configured –Commodity prices Force solution to: –No more than 2TB/server. –Require 10MB/s per 100GB storage Technology unconstrained by tender

Timetable 21 September - Planning meeting 12 October - Tenders to EJ 2 January - Tender closed (20 responses) 15 January - Evaluation/Shortlisting meeting. 8 February - Finished benchmarking. Meeting to select successful bidder 15 February - Order placed 27 March - Physical Installation complete 18 April - Systems installed - Service starts

Solutions Offered Internal IDE with PCI 3ware controller External SCSI/IDE RAID controllers PCI based SCSI RAID. External drives External SCSI RAID controllers Fibre Channel/SAN solutions Network attached storage (NetApp)

Only Shortlist SCSI/IDE Very competitive price Avoids complications of Internal PCI based RAID controllers “New technology” - accept some risk associated with this choice. Try and minimise

Price/TB after RAID ware IDE External SCSI/IDE PCI/SCSI External SCSI 50 NAS

Choosing a disk drive IDE or SCSI? –Conflicting responses. No evidence offered that SCSI is more reliable. Manufacturer’s reputation –No objective information available –Ensure diagnostic tools/support available Drive performance: differences exist, but are they significant? Rely on benchmark. Avoid drives with problems/issues (recent IBM drives) Very newest drives have additional risk

IDE/SCSI RAID Systems Intel based controllers (12 drive) –Zero-D ( –RAIDstorage ( –Transtec ( Intel i960 Based controllers (8 drive): –Older and slower - don’t buy these (Akhter) Infotrend IFT6300 (PowerPC) (8 drive) – (supplied by a number of companies - eg Streamline )

Benchmark Mainly used IOZONE but sanity check using Bonnie Well defined protocol (stability): –128MB system memory –New, empty, 150GB filesystem –Standard script Careful choice of kernel/filesystem Take care of Driver/Firmware updates

5400v7200 Sequential ext3

5400v7200 Stride Read

ZeroD v 3ware (6800) ext2

ZeroD v IBM FAST ext2/2.4.5-ext2

2 RAID5 Arrays+S/W Stripe

NFS Performance Not fully tested: 40MB/s write 30MB/s read

Post Tender Experience 6 Months of running experience –Initially many drive read errors - reported as remapped blocks on console. Bad batch of disks - now being replaced by Maxtor –Concern over method and algorithm used by controller to handle block read errors (when drives not ejected promptly remap area can overflow). Working with vendor. Since August reliability is much better. Solution can probably be made to work well but some way to go yet.

Latest Concerns(1) In preparing for this year’s purchase the following issues arose: 1) Most IDE manufacturers are downgrading warranty from 3--> 1 years. Some (eg Maxtor) are introducing enterprise class IDE disks at what is presumably a premium price 2) Short term disk capacities: – We bought 80GB*7200rpm – Maxtor's new Enterprise class 7200 rpm is already available up to 250GB. –Not sure about availability though. 320GB 5400 rpm drives also available. 3) Short term RAID controller enhancements –16 drive units available for Acusys controller –12 drive units now available for Infotrend. – Unlikely to get significantly faster controllers in the next few months.

Latest Concerns(2) 4)RAID controller speed Big concern because controllers are no faster than last purchase, bigger disks plus bigger RAID arrays means less performance per GB storage. Do we care - maybe. 5) Only really two manufacturers of external IDE RAID controllers (cf lots of PCI based solutions). 6) Serial ATA RAID controllers will be available very soon now. IDE is becoming more mainstream for the enteprise - possibly we will see more external RAID controllers in the future.

Conclusions Tender process was very successful –Wide range of solutions offered –Wide range of skills identified –Some competitive prices SCSI/IDE has good characteristics for larger HEP installations Too early to say if technology choice correct Establish a relationship with RAID supplier