Statistical Parametric Mapping Lecture 9 - Chapter 11 Overview of fMRI analysis Textbook: Functional MRI an introduction to methods, Peter Jezzard, Paul.

Slides:



Advertisements
Similar presentations
fMRI Methods Lecture6 – Signal & Noise
Advertisements

General Linear Model Beatriz Calvo Davina Bristow.
1st level analysis - Design matrix, contrasts & inference
Concepts of SPM data analysis Marieke Schölvinck.
1 st Level Analysis: design matrix, contrasts, GLM Clare Palmer & Misun Kim Methods for Dummies
Gordon Wright & Marie de Guzman 15 December 2010 Co-registration & Spatial Normalisation.
Statistical Parametric Mapping
Outline What is ‘1st level analysis’? The Design matrix
Section 1 fMRI for Newbies
Statistical Signal Processing for fMRI
Introduction to Functional and Anatomical Brain MRI Research Dr. Henk Cremers Dr. Sarah Keedy 1.
Basics of fMRI Preprocessing Douglas N. Greve
Statistical Parametric Mapping Lecture 10 - Chapter 12 Preparing fMRI data for statistical analysis Textbook: Functional MRI an introduction to methods,
MNTP Summer Workshop fMRI BOLD Response to Median Nerve Stimulation: A Comparison of Block and Event-Related Design Mark Wheeler Destiny Miller.
OverviewOverview Motion correction Smoothing kernel Spatial normalisation Standard template fMRI time-series Statistical Parametric Map General Linear.
Chapter 10 Lecture Mark D. Herbst, M.D., Ph.D..
The General Linear Model (GLM)
Haskins fMRI Workshop Part I: Data Acquisition & Preprocessing.
HELSINKI UNIVERSITY OF TECHNOLOGY LABORATORY OF COMPUTER AND INFORMATION SCIENCE NEURAL NETWORKS RESEACH CENTRE Variability of Independent Components.
Lecture 24: Cross-correlation and spectral analysis MP574.
Co-registration and Spatial Normalisation
The General Linear Model
With many thanks for slides & images to: FIL Methods group, Virginia Flanagin and Klaas Enno Stephan Dr. Frederike Petzschner Translational Neuromodeling.
Preprocessing of FMRI Data fMRI Graduate Course October 23, 2002.
Brain Mapping Unit The General Linear Model A Basic Introduction Roger Tait
SPM5 Tutorial Part 2 Tiffany Elliott May 10, 2007.
1 Hands-On Data Analysis Kate Pirog Revill and Chris Rorden Data from safety training –9 subjects –Finger-tapping task (12s tapping, 12s rest) –188 scans.
Keith Worsley Department of Mathematics and Statistics, and McConnell Brain Imaging Centre, Montreal Neurological Institute, McGill University Correlation.
Signal and noise. Tiny signals in lots of noise RestPressing hands Absolute difference % signal difference.
The basic story – fMRI in 25 words or less!. fMRI Setup.
FMRI Methods Lecture7 – Review: analyses & statistics.
Basics of fMRI Time-Series Analysis Douglas N. Greve.
Chapter 10 Lecture Mark D. Herbst, M.D., Ph.D.. Image Detail and Noise Two image characteristics that reduce the visibility of anatomy/pathology –Blurring.
Statistical Parametric Mapping
Statistical Parametric Mapping Lecture 11 - Chapter 13 Head motion and correction Textbook: Functional MRI an introduction to methods, Peter Jezzard, Paul.
Functional Brain Signal Processing: EEG & fMRI Lesson 14
FEAT (fMRI Expert Analysis Tool)
The General Linear Model (for dummies…) Carmen Tur and Ashwani Jha 2009.
SPM Pre-Processing Oli Gearing + Jack Kelly Methods for Dummies
Event-related fMRI SPM course May 2015 Helen Barron Wellcome Trust Centre for Neuroimaging 12 Queen Square.
Statistical Analysis An Introduction to MRI Physics and Analysis Michael Jay Schillaci, PhD Monday, April 7 th, 2007.
FMRI Modelling & Statistical Inference Guillaume Flandin Wellcome Trust Centre for Neuroimaging University College London SPM Course Chicago, Oct.
Idiot's guide to... General Linear Model & fMRI Elliot Freeman, ICN. fMRI model, Linear Time Series, Design Matrices, Parameter estimation,
The General Linear Model
The General Linear Model Guillaume Flandin Wellcome Trust Centre for Neuroimaging University College London SPM fMRI Course London, May 2012.
1 st level analysis: Design matrix, contrasts, and inference Stephane De Brito & Fiona McNabe.
The general linear model and Statistical Parametric Mapping I: Introduction to the GLM Alexa Morcom and Stefan Kiebel, Rik Henson, Andrew Holmes & J-B.
SPM and (e)fMRI Christopher Benjamin. SPM Today: basics from eFMRI perspective. 1.Pre-processing 2.Modeling: Specification & general linear model 3.Inference:
The general linear model and Statistical Parametric Mapping II: GLM for fMRI Alexa Morcom and Stefan Kiebel, Rik Henson, Andrew Holmes & J-B Poline.
The General Linear Model Christophe Phillips SPM Short Course London, May 2013.
The General Linear Model Guillaume Flandin Wellcome Trust Centre for Neuroimaging University College London SPM fMRI Course London, October 2012.
Parameters which can be “optimized” Functional Contrast Image signal to noise Hemodynamic Specificity Image quality (warping, dropout) Speed Resolution.
functional magnetic resonance imaging (fMRI)
Assessment of data acquisition parameters, and analysis techniques for noise reduction in spinal cord fMRI data  R.L. Bosma, P.W. Stroman  Magnetic Resonance.
The General Linear Model (GLM)
The general linear model and Statistical Parametric Mapping
The General Linear Model
Design Matrix, General Linear Modelling, Contrasts and Inference
The General Linear Model (GLM): the marriage between linear systems and stats FFA.
and Stefan Kiebel, Rik Henson, Andrew Holmes & J-B Poline
The General Linear Model (GLM)
The General Linear Model
The general linear model and Statistical Parametric Mapping
The General Linear Model
The General Linear Model (GLM)
The General Linear Model
The General Linear Model (GLM)
The General Linear Model
Predictive Neural Coding of Reward Preference Involves Dissociable Responses in Human Ventral Midbrain and Ventral Striatum  John P. O'Doherty, Tony W.
The General Linear Model
Presentation transcript:

Statistical Parametric Mapping Lecture 9 - Chapter 11 Overview of fMRI analysis Textbook: Functional MRI an introduction to methods, Peter Jezzard, Paul Matthews, and Stephen Smith Many thanks to those that share their MRI slides online

fMRI image example –array size 128x128x32 (2 mm x 2 mm x 5 mm) –FOV (256 mm x 256 mm x 160 mm) –time per point (full image volume) = 3 seconds (TR for this single shot EPI) –number of image volumes (time points) = 80 –time per session 3 sec x 80 = 240 sec ( 4 min) –4 blocks with finger movement each followed by a block of rest ~ 30 sec each –10 image volumes per block –BOLD signal higher during movement block –BOLD signal from brain location in primary motor area

Figure fMRI time series from a strongly activated voxel with visual stimulation. Signal is significantly larger than noise. Stimulus on 30 sec followed by off for 30 sec repeated for nine stimulus on and nine stimulus off epochs. (TR assumed = 3 sec)

The multiple time scales in fMRI - single shot GE EPI - time between readout data points (digitizer rate) –number of readout points determines duration time between middle of adjacent phase encode lines –number of phase encode lines determines duration TE which optimizes microscopic T2* signal time between slices –number of slices determines duration –correct slices to same time throughout volume for interleaved slice acquisition (all odd then all even) time between volumes (one per TR) –time points of interest for brain response –number of time points determines duration time between stimulation blocks –block duration determined by needs of experiment –used in regression analysis with general linear model to determine brain activation associated with stimuli Analysis and Experiment Design Acquisition protocol

B1B1 GzGz GxGx GyGy refocus acquire 2D Gradient Echo Echo Planar Imaging(EPI) Multi-slice volume 128x128x32 Interlaced all odd then all even slices - timing difference 1.5 sec 96 phase encode steps Time per slice (96 ms ) TE = 30 ms (time with zero phase encoding) T2* of GM ~ 50 ms (~ time of last phase encode here) Time per volume (TR = 3 sec) Readout sampling rate = 227 kHz Readout spacing = 4.4 us Pixel bandwidth = 1775 Hz Phase encode spacing = 1 ms

Pre-Processing Calculate magnitude image from k-space data (usually done automatically by MRI system) Slice timing correction (event related designs) –temporal interpolation of voxel time courses to same time point for each volume Motion correction –rotation and translation to align each image volume (rigid body transform) Noise reduction –spatial smoothing (remove noise but preserve anticipated activations) Value normalization –adjust each image volume to have same mean value Temporal filtering –high-pass to remove baseline shifting –low-pass to reduce random noise further Removes artifacts and conditions data for subsequent statistical analyses.

For short duration epochs of 10 seconds or less slice timing correction is important.

Temporal translation requires interpolation. Here TR = 3 sec. All odd slices were acquired first (0-1.5 sec) followed by the even slices ( sec), so adjacent slices were sampled 1.5 seconds apart.

For long duration epochs such as the 30 second blocks in our finger tapping example slice timing differences are comparatively small (1.5 sec) so correction not absolutely necessary. Shifting the model uses separate models for even and odd slices, which is not preferred.

Pre-Processing Calculate magnitude image from k-space data (usually done automatically by MRI system) Slice timing correction –temporal interpolation of voxel time courses to same time point for each volume Motion correction –rotation and translation to align each image volume (rigid body transform) Noise reduction –spatial smoothing (remove noise but preserve anticipated activations) Value normalization –adjust each image volume to have same mean value Temporal filtering –high-pass to remove baseline shifting –low-pass to reduce random noise further Removes artifacts and conditions data for subsequent statistical analyses.

linear displacement (mm) scan or volume number Figure 11.6 (bottom)

angular displacement (radians) scan or volume number Figure 11.6 (top) radians ~ 0.57 degrees 1 degree ~ radians

Pre-Processing Calculate magnitude image from k-space data (usually done automatically by MRI system) Slice timing correction –temporal interpolation of voxel time courses to same time point for each volume Motion correction –rotation and translation to align each image volume (rigid body transform) Noise reduction –spatial smoothing (remove noise but preserve anticipated activations) Value normalization –adjust each image volume to have same mean value Temporal filtering –high-pass to remove baseline shifting –low-pass to reduce random noise further Removes artifacts and conditions data for subsequent statistical analyses.

Spatial Filtering Figure D or 3D spatial filter to improve SNR but preserve anticipated activations. To do this recommend that FWHM of filter to be smaller than activation extent. Here FWHM of Gaussian filter is 5 mm. Issues with differences in pixel and slice spacing for index (not mm) based filters. Suggestion: Use 2D filter to match the averaging introduced by thick slices. Before spatial filtering. After spatial filtering.

Pre-Processing Calculate magnitude image from k-space data (usually done automatically by MRI system) Slice timing correction –temporal interpolation of voxel time courses to same time point for each volume Motion correction –rotation and translation to align each image volume (rigid body transform) Noise reduction –spatial smoothing (remove noise but preserve anticipated activations) Value normalization –May adjust each brain volume to have same mean/median value (required for multi-subject studies) Temporal filtering –high-pass to remove baseline shifting –low-pass to reduce random noise further Removes artifacts and conditions data for subsequent statistical analyses.

Pre-Processing Calculate magnitude image from k-space data (usually done automatically by MRI system) Slice timing correction –temporal interpolation of voxel time courses to same time point for each volume Motion correction –rotation and translation to align each image volume (rigid body transform) Noise reduction –spatial smoothing (remove noise but preserve anticipated activations) Value normalization –adjust each image volume to have same mean value Temporal filtering –high-pass to remove baseline shifting –low-pass to reduce random noise further Removes artifacts and conditions data for subsequent statistical analyses.

Temporal Filtering Figure Time course of “single voxel” before temporal filtering (top) and after high-pass filtering and overlaying of the expected time course model. High-pass filtering removes low frequency non-physiologic modulation of activations in this example. Baseline was restored in this example.

Statistical analysis of activation images “univariate analysis” - analyze each voxel’s time course independently “multivariate analysis” - incorporates spatial relationships with temporal analysis “model-based analysis” - a model of expected response is compared with the data “model-free analysis” - effects of interest searched for based on other criteria (i.e. statistical independence of spatial or temporal components).

General Linear Model (GLM) y(t) measured signal from a voxel at time t. x(t) predicted model of stimulus signal (with HRF correction). c model constant. e(t) error between the model and measured data.  unitless parameter indicating how changes in y(t) relate to changes in x(t) (i.e. dy/dx =  ). n number of images. t n x dt where dt is the time between images (TR for EPI). [nx1] Seek best fit between modeled and measured signals for “each” voxel. Regression analysis.  should be high in voxels activated by stimulus and low in others. [nx1]

General Linear Model (GLM) Model equation with two predicted stimulus time courses. Time is left off here to simplify the model equation.  1 and  2 parameters indicate how changes in models x 1 and x 2 relate to changes in the measured signal y. Assumes that dy/dx 1 =  1 and similarly dy/dx 2 =  2. The model variables x 1 and x 2 are often called “explanatory variables” or EVs. The ratio of  s gives relative predictive power of the EVs. Seek best fit between modeled and measured signals for each voxel. Multiple regression analysis.

General Linear Model (GLM) Multiple regression assumptions –linearity of relationships –Explanatory variables are independent –the same level of relationship throughout the range of the explanatory variables ("homoscedasticity"), i.e. beta is constant. –variables can be continuous –absence of outliers –data whose range is not truncated (unnaturally). The model being tested must be correctly specified. –The exclusion of important causal variables or the inclusion of extraneous variables can markedly change beta and error values and hence the interpretation of the importance of the explanatory variables. –cross-product terms can be used to study interactions

Figure Square wave pattern of stimulation (solid) and predicted response x(t) (dots) after convolution with a hemodynamic response function (HRF) model. The model has both delay and smoothing effects. Note the similarity to the measured response from Figure 11.2 (lower right) except for noise. The predicted stimulation waveforms run from -0.5 to +0.5, but we can run them from 0 to 1 without a problem since the GLM constant can account for baseline offset of the data. t x(t) HRF area = 1

Data from Figure 11.3 is sometimes displayed graphically as an image with time increasing from top to bottom and signal level increasing from left to right. For each time point (row) the graphic image brightness represents the signal level. The expected signal is called the explanatory variable or EV. This is x(t) in the GLM equation. When using more than one EV a “Design Matrix” simplifies representation.

EV 1 EV 2 Figure Example of “design matrix” with two explanatory variables (each predicted from stimulus pattern convolved with the HRF). [nx1][nx2][2x1] 2 = the number of EVs (explanatory variables) n =the number of time points (fMRI images) DESIGN MATRIX “c” can be included in the design matrix. [nx1]

Figure Modeling of an interaction between stimuli. EV 1 and EV 2 model separate stimuli, while EV 3 models the interaction, i.e. accounts for the response when both stimuli are applied together. Interaction is assumed to be present. EV 1EV 3EV 2

Figure The model (design matrix) used in the GLM analysis of the heat-warm experiment. EVs 1 and 5 model pain and warm. EVs 3 and 7 model conditioning to pain and warm. Even EVs are temporal derivatives; used to allow phase shifting during fitting (details later chapter). EV 1EV 2EV 3EV 4EV 5EV 6EV 7EV 8

Statistical Parametric Map Figure Significant differences between two subject groups in the pain-warm contrast study.

Figure (Bottom) Mean of 18 subjects high-resolution 3D images following alignment with the MNI-152 template (top). fMRI volumes are transformed to the template so overlaying SPM can be done since both experience same align blurring.

Figure Stages in the rendering of activation onto a high-resolution structural image. 3D surface with activation volume in red produced by Mango.

FSL slides help with these basic concepts see GLM.ppt at