The ProteomeWorks System is the global alliance of Micromass and Bio-Rad Laboratories dedicated to furthering proteomics research.

Slides:



Advertisements
Similar presentations
Les détecteurs de masse : une révolution en chromatographie 1ère partie : Introduction à la spectrométrie de masse Pr. Jean-Louis Habib Jiwan UCL – Département.
Advertisements

Introduction to MALDI-TOF MS
MALDI-TOF Mass Spectrometry and Introduction to Proteomics Dr. Steve Hartson Oklahoma State University Dept. Biochemistry and Molecular Biology Recombinant.
Mass Spectrometry in Life Science: Technology and Data-Evaluation H. Thiele Bruker Daltonik, Germany.
Mass Spectrometry in the Biosciences: Introduction to Mass Spectrometry and Its Uses in a Company Like Decode. Sigurður V. Smárason, Ph.D. New Technologies.
LC-MS Based Metabolomics. Analysing the METABOLOME 1.Metabolite Extraction 2.Metabolite detection (with or without separation) 3.Data analysis.
Proteomics The proteome is larger than the genome due to alternative splicing and protein modification. As we have said before we need to know All protein-protein.
PROTEIN IDENTIFICATION BY MASS SPECTROMETRY. OBJECTIVES To become familiar with matrix assisted laser desorption ionization-time of flight mass spectrometry.
Mass spec lecture. What kind of info can mass spec give you? Molecular weight Elemental composition (low MW with high resolution instrument) Structural.
Beta-Galactosidase Digest from 500 fmole Loaded on a 1-D Gel A. B. C. Bovine Serum Albumin Digest from 250 fmole Loaded on a 1-D Gel Automation of In-Gel.
LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata  Instrument Description  Data Acquisition  Data Processing.
Protein Identification with Mascot Software (Laxmana Rao Y. and Gopalacharyulu P.V.)
Basics of 2-DE and MALDI-ToF MS
Proteomics Informatics Workshop Part I: Protein Identification
Previous Lecture: Regression and Correlation
HOW MASS SPECTROMETRY CAN IMPROVE YOUR RESEARCH
FIGURE 5. Plot of peptide charge state ratios. Quality Control Concept Figure 6 shows a concept for the implementation of quality control as system suitability.
Proteomics Informatics – Overview of Mass spectrometry (Week 2) Ion Source Mass Analyzer Detector mass/charge intensity.
Basic Scheme of Biological Phenomena
My contact details and information about submitting samples for MS
Proteomics Informatics (BMSC-GA 4437) Course Director David Fenyö Contact information
Introduction to high-throughput analysis of proteins and metabolites by Mass Spectrometry The basic principle Brief introduction of techniques Computational.
Proteomics Informatics – Overview of Mass spectrometry (Week 2)
<Instant Notes, D. Kealey & P.J. Haines>
Evaluated Reference MS/MS Spectra Libraries Current and Future NIST Programs.
Tryptic digestion Proteomics Workflow for Gel-based and LC-coupled Mass Spectrometry Protein or peptide pre-fractionation is a prerequisite for the reduction.
Comparison of chicken light and dark meat using LC MALDI-TOF mass spectrometry as a model system for biomarker discovery WP 651 Jie Du; Stephen J. Hattan.
Introduction : Standard methodologies for enzymatic digestions have changed little in the past 40 years. The same process for sample incubation with trypsin,
Chapter 9 Mass Spectrometry (MS) -Microbial Functional Genomics 조광평 CBBL.
Mass spectrometry session. Summary Fiehn (1) Standardization important Reporting important, but has to be feasible Does not matter which MS instrument.
Session II Today’s Proteomics 台大生技教改暑期課程. What’s “proteomics” ? "The analysis of the entire protein complement expressed by a genome, or by a cell or.
INF380 - Proteomics-61 INF380 – Proteomics Chapter 6 – Mass Spectrometry – MALDI TOF The MALDI-TOF instruments are the simplest MS instruments suitable.
A Comprehensive Comparison of the de novo Sequencing Accuracies of PEAKS, BioAnalyst and PLGS Bin Ma 1 ; Amanda Doherty-Kirby 1 ; Aaron Booy 2 ; Bob Olafson.
Laxman Yetukuri T : Modeling of Proteomics Data
Untargeted Metabolomics: Tandem LC-MSMS. Column and Flow Rate Selection Insert Barnes table for flow rates and sensitivity gain. Reverse Phase and Normal.
INF380 - Proteomics-51 INF380 – Proteomics Chapter 5 – Fundamentals of Mass Spectrometry Mass spectrometry (MS) is used for measuring the mass-to-charge.
Supplement material to Ref. JASMS Ms. No Detection of an amine impurity and quality assessment related to this impurity of the UV MALDI matrix.
Lecture 9. Functional Genomics at the Protein Level: Proteomics.
In-Gel Digestion Why In-Gel Digest?
PEAKS: De Novo Sequencing using Tandem Mass Spectrometry Bin Ma Dept. of Computer Science University of Western Ontario.
Proteomics What is it? How is it done? Are there different kinds? Why would you want to do it (what can it tell you)?
The Future of Time-of-flight Mass Spectrometry
Automating Drug Metabolism Studies
Overview of Mass Spectrometry
Methods for LTQ Orbitrap A Guided Tour with Examples
Data Management Support for Life Sciences or What can we do for the Life Sciences? Mourad Ouzzani
Novel Peptide Identification using ESTs and Genomic Sequence Nathan Edwards Center for Bioinformatics and Computational Biology University of Maryland,
Salamanca, March 16th 2010 Participants: Laboratori de Proteomica-HUVH Servicio de Proteómica-CNB-CSIC Participants: Laboratori de Proteomica-HUVH Servicio.
Quantitative MALDI-TOF for Clinical Applications.
Deducing protein composition from complex protein preparations by MALDI without peptide separation.. TP #419 Kenneth C. Parker SimulTof Corporation, Sudbury,
2014 생화학 실험 (1) 6주차 실험조교 : 류 지 연 Yonsei Proteome Research Center 산학협동관 421호
What is proteomics? Richard Mbasu and Ben Richards.
Introduction to Liquid Phase Mass Spectrometry
김지형. Introduction precursor peptides are dynamically selected for fragmentation with exclusion to prevent repetitive acquisition of MS/MS spectra.
RANIA MOHAMED EL-SHARKAWY Lecturer of clinical chemistry Medical Research Institute, Alexandria University MEDICAL RESEARCH INSTITUTE– ALEXANDRIA UNIVERSITY.
Yonsei Proteome Research Center Peptide Mass Finger-Printing Part II. MALDI-TOF 2013 생화학 실험 (1) 6 주차 자료 임종선 조교 내선 6625.
Target Analyses in Parallel Reaction Monitoring Mode (PRM)
An introduction to Mass spectrometry. What is mass spectrometry? Analytical tool measuring molecular weight (MW) of sample Only picomolar concentrations.
Post translational modification n- acetylation Peptide Mass Fingerprinting (PMF) is an analytical technique for identifying unknown protein. Proteins to.
Peptide Mass Finger-Printing Part II. MALDI-TOF
Mass Spectrometry 101 (continued) Hackert - CH 370 / 387D
Mass spectrometry data enhancement software
Tandem MS.
Time of Flight Analyzers
Schematic of the principles of mass spectrometry (MS).
Proteomics Informatics David Fenyő
Proteomics Informatics –
Top-down protein identification.
Proteomics Informatics David Fenyő
Presentation transcript:

The ProteomeWorks System is the global alliance of Micromass and Bio-Rad Laboratories dedicated to furthering proteomics research.

The ProteomeWorks System ~ New Mass Spectrometry Systems ~ At Pittcon 2001 Micromass introduced a range of e- MS TM enabled MALDI-TOF MS / MS-MS & ESI LC-MS-MS systems and Mass-Informatics TM Software to leverage The ProteomeWorks TM System HT TM Q-Tof Ultima TM Q-Tof micro TM

Micromass’ new networked MALDI TOF-MS & sample management system “2D-gel-MS analyser for proteomics factories” HT TM [new instrument]

HT TM - Networked MALDI-TOF MS REFLECTRON Peptide Mass Fingerprinting LINEAR Intact Proteins

ELECTRO MAGNETIC GRIPPER TARGET PLATE CASSETTE 2 X - Y ROBOTIC ARM TARGET PLATE CASSETTE 1 HORIZONTAL AXIS MOTOR VERTICAL AXIS MOTOR BAR CODE SCANNER VACUUM LOCK LID IN COLUMN OUT COLUMN VERTICAL FLIGHT TUBE AND REFLECTRON HOUSING HT TM - Sample Management System 80 x 96/384-Sample Targets (bar coded)

HT TM - Networked MALDI-TOF MS Linear and reflectron ion optics options 80 x 96/384-Sample target management system Bar coded sample target plates Automated Laser Positioning System (ALPS) for sample target alignment and sample indexing Intelligent acquisition / calibration algorithm Web-enabled Client-Server Mass-Informatics for interrogation of non-redundant protein dB …converts samples into knowledge not ‘just’ spectra

ProteinLynx TM Global SERVER web-enabled Mass-informatics

ProteinLynx TM Global SERVER export to PDQuest Annotation Tools

PDQuest Annotation Tools C L I C K

MS & MS-MS Techniques for Peptide / Protein Analysis

Q-Tof Ultima TM family [new instruments] DDA TM Micromass’ SuperPremium family of MALDI MS-MS and ESI MS-MS systems for PROTEOMICS and structural analysis

DDA TM Q-Tof Ultima  …the SuperPremium family of MS-MS Q-Tof Ultima  MALDI The high throughput MALDI MS-MS Q-Tof Ultima  API The SuperPremium API LC-MS-MS Q-Tof Ultima  GLOBAL The flexible research platform for API LC-MS-MS / MALDI MS-MS

Q-Tof Ultima TM MALDI [new instrument] Dedicated MALDI MS-MS system V & W- OPTICS options ProteinLynx Global SERVER e-MS enabled

Q-Tof Ultima MALDI with V OPTICS 10,000 FWHM

Q-Tof Ultima MALDI with W OPTICS 20,000 FWHM

MALDI MS-MS is superior to PSD ADH 1 pm/µl PSD ADH 1 pm/µl Q-Tof Ultima MALDI MS-MS

ProteinLynx TM Global SERVER... Matching MS-MS spectra to dB of known protein or nucleotide sequence.

Q-Tof Ultima TM API [new instrument] Dedicated API (ESI) LC-MS-MS system V & W- OPTICS options DDA - Precursor Ion Discovery (patent applied for) – “Neutral Loss” – “Precursor Ion” – High resolution – Exact mass – Compatible with HPLC ProteinLynx Global SERVER e-MS enabled

Q-Tof Ultima API with W OPTICS 20,000 FWHM

Q-Tof Ultima TM API...comparison of V & W- OPTICS Resolution

The superior peptide sequence coverage provided by ESI MS-MS data enables de novo sequencing

Sequencing results from MS-MS of m/z 841.5

Q-Tof Ultima TM GLOBAL [new instrument] Flexible API & MALDI MS-MS research platform API / MALDI changeover without venting V & W- OPTICS options LC-DDA-MS – Precursor ion discovery – “Neutral Loss” – “Precursor Ion” – Exact mass ProteinLynx Global SERVER e-MS enabled

Q-Tof Ultima GLOBAL

Q-Tof micro TM [new instrument] Micromass’ finest API Q-Tof technology for structural analysis & protein characterisation … SMALLER SMARTER WIRED DDA TM

Q-Tof micro TM … SMALLER Z SPRAY TM nanoflow ESI inlet technology 5000 FWHM resolution 5ppm RMS exact mass measurement Dynamic External Calibration (DXC TM ) m/z range

Q-Tof micro TM …SMARTER …WIRED Data Directed Analysis (DDA) – Automates analysis of protein digests by LC-DDA-MS Precursor Ion Discovery (patent applied for) – “Neutral Loss” – “Precursor Ion” – High resolution – Exact mass Compatible with HPLC Maximising data quality

Data Directed Analysis DDA TM Exclusion of 1 + background ions

The New e-MS TM Enabled Mass Analysers of The ProteomeWorks TM System... msinnovation.com

The ProteomeWorks System is the global alliance of Micromass and Bio-Rad Laboratories dedicated to furthering proteomics research.