12. Health, Safety and Environment (Tasks 10 & 11)

Slides:



Advertisements
Similar presentations
MATERIAL SAFETY DATA SHEET
Advertisements

Hazard and Operability Study
Hazard Survey Dow Fire and Explosion Index is the most popular form of hazard survey. A formal systematized approach using a ranking form (similar to an.
Risk Analysis For: ES-317Y and ES Plant Design Project at UWO By: R.A. Hawrelak, P.Eng. - Lecturer Dept of Chem & Biochem Eng’g Dow Chemical –
Where We Go Wrong In Distillation Towers Dick Hawrelak Presented to ES317Y in 1999 at UWO.
Where We Go Wrong In Line Sizing Dick Hawrelak Presented to ES317Y in 1999 at UWO.
Reading a Material Safety Data Sheet v An MSDS is written information about the chemicals you are exposed to in shop/work v Every chemical in a shop must.
PLANT DESIGN (I) Prof. Dr. Hasan farag.
Storage Tanks Selection and Sizing CBE Oct 02
© BLR ® —Business & Legal Resources What’s the Big Deal? Flammable and combustible liquids: Are easily ignited and ignite with explosive force Burn.
Fires and Explosions.
OMNI FACILITY SERVICES Copyright  Progressive Business Publications Material Safety Data Sheets.
Hazardous Materials Emergency Response Training.
23 killed, 130 Injured, $1,300MM damage
Safe Handling of Flammable and Combustible Liquids
Hazardous Materials Response
1 Flammable and Combustible Liquids INSY 3020 Spring 2006.
Material Safety Data Sheets MSDS. What are they used for? A Material Safety Data Sheet (MSDS) is designed to provide both workers and emergency personnel.
1 Chemical Process Safety. 2 Outline of Lecture on Chemical Process Safety Inherent Safety Hazard Identification Risk Assessment Fire Protection.
Material Safety Data Sheets
Pressure Safety Valve Design Presented to ES-317 at UWO in 1999 Dick Hawrelak.
M.S.D.S.. MSDS MSDS Provides Information What is it Who makes or sells it Where the company is located Why it’s hazardous How you can be exposed to.
Chemical Safety Labels NFPA- National Fire Protection Assoc. MSDS – Material Safety Data Sheets.
CNG STATION & GARAGE MODIFICATION CODES & STANDARDS Graham Barker Business Development Manager.
MSDS = Material Safety Data Sheet
Where We Go Wrong In Vessel Design Dick Hawrelak Presented to ES-317Y in 1999 at UWO.
FLAMMABLE AND COMBUSTIBLE LIQUIDS
Copyright © Flammable & Combustible Liquids.
Process Hazard Analysis DOW Fire & Explosion Index ChE 258 Chemical Process Safety University of Missouri - Rolla.
Where We Go Wrong In Pump Design Dick Hawrelak Presented to ES317Y in 1999 at UWO.
CONCEPTS TO PREVENT FIRES & EXPLOSION
Dow Fire and Explosion Index (FEI) Dick Hawrelak Presented to ES317Y in 2001 at UWO.
Dr Daniel Colbourne 36th Meeting of the Open-ended Working Group of the Parties to the Montreal Protocol – Side Event UNEP.
ERT 312 SAFETY & LOSS PREVENTION IN BIOPROCESS HAZARDS IDENTIFICATION Prepared by: Miss Hairul Nazirah Abdul Halim.
Ohio Hazmat & WMD Technician
Hazard Communication. SAFETY The purpose of OSHA Hazard Communication Standard is to ensure that the hazards of all chemicals produced or imported are.
Flammable and Combustible Liquids
LABORATORY SAFETY Chemical Hazard Label. What is a MSDS sheet? A Material Safety Data Sheet (MSDS) is designed to provide both workers (students and staff.
MSDS Material Safety Data Sheet
ERT 312 SAFETY & LOSS PREVENTION IN BIOPROCESS INTRODUCTION TO RELIEF
Flammable and Combustible Liquids Presented by Martina Schmeling Adapted From OSHA.
CXS490 Carbon Dioxide Systems
Florida Operations Level Hazardous Materials Training Unit 2.2 Physical and Chemical Properties.
Handling and Storage of Hazardous Chemicals direct.com/assets/ite ms/c126.jpg.
Material Safety Data Sheets Interpreting and Understanding Information on a MSDS.
Safe handling, Storage, and Disposal of Chemicals
02-1 Hazardous Materials Incident Considerations l Chapter 2 –Hazardous Materials Reference Sources.
Introduction to Hazardous Evaluation Techniques Guidelines for Hazardous Evaluation Procedures (1992 by AIChE). Second Edition with Worked Examples. Center.
PLANT DESIGN.
Hazardous Materials Subpart H. Subpart H Standards Compressed Gases Acetylene Hydrogen Oxygen Nitrous Oxide Flammable.
Environment Presentation to CBE 497 By R.A. Hawrelak 12 Feb, 2002.
Flammable and Combustible Liquids. Introduction !The two primary hazards associated with flammable and combustible liquids are explosion and fire !Safe.
Explosion An explosion is a rapid expansion of gases resulting in a rapid moving pressure or shock wave. The expansion can be mechanical or it can be.
FLAMMABLES. 1. PROPERTIES OF FLAMMABLES Combustion (redox) reactions Solids, gases, most commonly liquids Fire Tetrahedron Ignition sources External-
What does WHMIS mean? W Workplace H Hazardous M Materials I Information S System WHMIS is a Canada wide hazard communication system developed to provide.
March 2004 Material Safety Data Sheets Hazard Communications Training for Employees.
© 2012 Delmar, Cengage Learning Chapter 11 Engineering Controls.
ERT 312 SAFETY & LOSS PREVENTION IN BIOPROCESS HAZARDS IDENTIFICATION
FLAMMABLE AND COMBUSTIBLE LIQUIDS 1 Bureau of Workers’ Comp PA Training for Health & Safety (PATHS) OSHA 29CFR PPT
Flammable and Combustible Liquids Standard 29 CFR Part City of Council Bluffs Presented by: SilverStone Group © 2006, 2012 Zywave, Inc. All rights.
Fault Tree Analysis for Fatality Prevention Dr. Steven A. Lapp President - Design Sciences, Inc.
Flammable Liquids Directorate of Training and Education
Process Safety Management Soft Skills Programme Nexus Alliance Ltd.
Misuse of Combustible Gas Meters Supervisor Training 1/11/08.
Dow Fire and Explosion Index (FEI)
2. Hazards Survey Suitable for identifying hazards for equipment design, layout, storage etc. Can be as simple as survey of inventory/stock of hazardous.
Risk Management and Mitigation
Flammable & Combustible Liquids
HAZOP Guidewords Base Set
Dow Fire and Explosion Index (FEI)
Presentation transcript:

12. Health, Safety and Environment (Tasks 10 & 11) By R.A. Hawrelak for Dr. A. Prakash 19 Feb 02

Today’s Objectives Identify Hazards – Hazard Analysis. Mitigate Process Hazards. Minimize Environmental Impact. Prepare a Safety and Environmental Mission Statement (RAH). “Our group endeavored to design the safest plant possible. This included ….”

Fire & Explosion & Toxic Hazards Upper flammable limit (UFL or UEL). Lower flammable limit (LFL or LEL). Auto-ignition temperatures. Flash point temperature. Polymerization potential. Toxic data & carcinogen rating, ca. Spill mitigation (foam, water).

Steps to Prevent Hazards Relief devices – PSVs, PRDs, PVRVs Leak detection – where and how. Emergency Block Valves, EBVs. Dikes / Drainage – away from equipment. Flares / Ventilation – where and how. Fire Water Supply – Looping in ISBL. 0.25 usgpm/sf water on all hc vessels. Reactive Chemical and PHA Reviews.

Steps to Prevent Hazards – cont’d Layout - FEI Separation Within ISBL. Intrinsically Safe Electrical Equipment. Harden Control Room to withstand 1 Ton of TNT at 200 ft. or 1 Ton of TNT at 100 ft. Remote Storage for Hazardous Chemicals. Greenbelt Separation for Municipal Planning. Cradle to Grave Safety Training Programs. Operating Discipline for change of command. Emergency Response Drills – Dry Runs.

Product Stewardship Safety doesn’t end at the company fence line. Companies with a good PS program provide safety training to their customers. Companies must respond to LOC Spill situations for all products being delivered to their customers. Goal No. 1: Dow ER team will be in the air within 1 hour of notification.

Hazard Communication Up-to-date process flow diagrams and P&IDs. Proper labeling. MSDS (Material Safety Data Sheets) Required to include MSDS of products (AP). Required to include MSDS of feeds. (RAH) Required to include MSDS of intermediates. (RAH) http://eng-dellsrv02/nioshdbs

Liquid Classification - NFPA National Fire Protection Association Basis – NFPA 325 Reactivity (Nr) Flammability (Nf) Health (Nh)

Reactivity (Nr) The reactivity factor, (Nr), can be obtained from a qualitative description of the instability (or reactivity with water) of the substance, mixture or compound at ambient temperatures as follows:

Flammability (Nf) Flash point by closed-cup method. Boiling point at standard pressure 14.7 psia.

Health (Nh)

Example Ethylene Oxide Nh = 2 Nf = 4 Nr = 3 When describing a feedstock, the following description is found in many Dow reports: “Ethylene Oxide (Nh=2, Nf = 4, Nr = 3) is a basic feed for the plant.” ….

NIOSH National Institute for Occupational Safety and Health. Online Pocket Guide to Chemical Hazards http://www.cdc.gov/niosh/npg/npgdname.html Exposure limits, flash points, toxicity. NIOSH also has a Liquid Classification

Vapor Pressure Needed to determine operating pressure of storage vessels at ambient conditions. If Vapor pressure drops below atmospheric pressure, air can leak into vessels storing flammables. Big hazard. To keep pressure above atmospheric pressure heat vessel, or use inert pad / depad system with safe disposal of vents.

Antoine Constants Log10(P) = A + B/(t+C) P is in psia T is in degrees Centigrade Select three sets of temperature and vapor pressure in desired temperature range. 3 Eqns – 3 unknowns. Solve for A, B, C. Beware, there are many forms of this eqn. and the constants are not common to each eqn. RAH CD program available to determine A,B,C.

Vapor Pressure of EO

The Enthalpy Chart The engineer’s best friend. Determine when flashing situations exist. Know how to calculate the % flash. Mass balance F = 100 = V + L Heat balance = Hf(100) = V(Hv) + L(HL) Two equations, two unknowns. Any flash above 30% will atomize all the liquid – really big hazard.

The Enthalpy Chart

Hazards of Two Phase Flow

Hazards of Water Hammer

Maldistribution Maldistribution of flow in lines, headers, exchangers and reactors often results in equipment failure or LOC.

Entrainment Liquid entrainment by a vapor is still one of the biggest problems in a chemical plant. Entrainment can destroy mass and energy balances. Entrainment leads to 2-phase flow vibration problems and ultimately LOC. Good Knock-out pot design minimizes entrainment.

Pressure Safety Valves PSVs required by law for all pressure vessels with a Design Pressure greater than 15 psig. PSVs and PVRVs are installed on vessels below 15 psig to prevent LOC. Many design bases are used. Designer must follow company practice. Design methods too complex for this course. Methods available on RAH CD.

Pressure Vessels (>15 psig DP) Select Design Pressures and Design Temperature from worst case operating conditions. Note flange rating. Examine depressuring to 14.7 psia for minimum Design Temp & Mtls of Constr. U.S. law requires a risk mgt plan, rmp, on worst case flammable and all toxic storage tanks. http://www.epa.gov/ceppo/tools/rmp-comp/rmp-comp.html Free download.

U.S. EPA rmp vs CDN MIACC Major Industrial Accidents Council of Can. Storage of 400,000 lbs of EO - toxic MIACC 2 pt. buffer zone 293m @ 1E-06. RAH 3 pt. buffer zone 600m @ 1E-08. rmp endpoint is ERPG2 = 50 ppmv rmp gives 24 km. for ER plan. A dispersion study > 6.6 km. for ER plan. All companies in Sarnia now use U.S. rmp.

Emergency Response Data B-M Heavy Gas Dispersion Model. LC10 @ 320m. (2 hr exposure). LC01 @ 535m. (2 hr exposure). IDLH @ 1,900m. (30 min. exposure). ERPG2 Dose @ 5.7 km by D = ò C2(dt) where C = ppmv and dt = time. ERPG2 ER Dist. @ 6.6 km for 50 ppmv.

Hazard Techniques

Dow Fire and Explosion Index Dow Fire and Explosion Index is a basic standard around the world. Dow F&EI is used for separation of adjacent unit operations to minimize probable loss. Insurance rates determined by FEI. CD Version – computerized FEI with 3 examples plus PowerPoint presentation.

FEI

Dow FEI Credit Factors

Unit Analysis Summary

FEI Separation Results

HAZOPS HAZOP was developed by Lawley (1974) of ICI. Based on early account by Elliott & Owen (1968). Hazop studies are carried out by an experienced, multidisciplinary team. Review all physical aspects of a process (lines, equipment, instrumentation) to discover potential hazards. PowerPoint presentation available.

Example For Hazop Review

After a Hazop

End of Safety Presentation Good luck in applying your safety knowledge to your final 497 report.