RMS alarm under IHA decontamination 2012. 9. 25 Shin-Kori Nuclear Power Plant Korea Hydro & Nuclear Power.

Slides:



Advertisements
Similar presentations
The cleaning procedures for Operating Suites are broken into 2 groups.
Advertisements

Functions of a Greenhouse Competencies
EMERGENCY MEDICAL MANAGEMENT OF RADIATION CAUSALTIES IN HOSPITAL Module XVII.
Chemical Fume hood or Biosafety Cabinet
 Knowledge of the proper procedures in the special handling, use, storage, and disposal of hazardous materials and wastes.
Radiological Emergency Procedures FOR ALL ISOTOPES 1.Prevent others from entering the affected area or coming into contact with the potentially radioactive.
2 3 Risks are present whenever people are in contact with:  Natural or organic materials  Substances of animal origin  Food and food products  Organic.
Protocol for Chemical Spills By Gordon Krueger Environmental Safety Specialist University of Northern Iowa Environmental Health and Safety.
Critical Task Based Job Hazard Analysis Example Step 1: As part of the Walkdown Start with the major work activities and list them as tasks in the JHA.
Laboratory Fume Hoods In accordance with Title 8 CCR Section , Ventilation Requirements for Laboratory-Type Hood Operations. California State University.
Ventilation Systems As Control Measures. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit.
Liquid Carbon Dioxide Solid carbon dioxide is converted to liquid which quickly converts to gas.
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Industrial Ventilation - A major control measure Dr. AA, UTM.
Review Topic: Laboratory Safety Answer the question then go to the next slide for the answer.
9. Cleanroom Testing and Monitoring. Purposes for initial test: Fulfill the design –working correctly and achieving the contamination standards Bench-mark:
Infection Prevention and Control
Intervention for Chronic and Emergency Exposure Situations Basic Concepts of Emergency Preparedness Personal Protective Equipment, Devices and Procedures.
Introduction Hazards are an inherent component of the workplace whether we recognize them or not. Some are easy to spot and are known by almost everyone.
Employee Training 60-Minute Annual Training Certification Process Personal Protection Equipment CLICK HERE TO START.
Module 6 Exposure Control and Personnel Monitoring.
Steam Traps Function and Types.
ALARA Programs & Occupational Dose Trend in Wolsong NPP Korea Hydro & Nuclear Power Co., Ltd Wolsong Nuclear Power Plant Unit 3&4.
What is infection? An illness caused by the spread of micro-organisms (bacteria, viruses, fungi or parasites) to humans from other humans, animals or the.
Tulane University - Office of Environmental Health & Safety (OEHS) Personal Protective Equipment For Tulane Employees Who Have the Potential to Use PPE.
Personal Protective Equipment
PERSONAL PROTECTIVE EQUPMENT  To define personal protective equipment requirements and indications for use in patient care PURPOSE.
1 AFPC Norm Decontamination Facility Plant (NDF) 1.Introduction - The passage of produced water through pipe work and plants leads to the built up of Norm.
VENTILASI TRI MARTIANA. Introduction A good and effective ventilation system is necessary in a workplace which have processes that emit air contaminants.
Authorization and Inspection of Cyclotron Facilities Authorization for the Decommissioning of the Facility.
Radiation Safety Management KHNP Lee Eung-Il HANUL Unit4 Steam Generator Replacement.
Respiratory Safety Public Safety Murray State University.
1 Management of Occupational Exposure Dose using Entrance/Exit Processing System in Shika Nuclear Power Station Takeshi Masaki Nuclear Power Dept. Hokuriku.
MODULE “PROJECT MANAGEMENT AND CONTROL” RADIATION PROTECTION SAFE DECOMMISSIONING OF NUCLEAR POWER PLANTS Project BG/04/B/F/PP , Programme “Leonardo.
IAEA International Atomic Energy Agency Radiation Protection Issues in Nuclear Installations (NPP & RR) Laszlo Sagi Radiation Safety and Monitoring Section.
LEAD SAFETY PROGRAM. REFERENCES 29 CFR CFR MCO F CHAPTER 17 BASE INSTRUCTION Lead Abatement 29 CFR MCO F HUD.
Radionuclides Sampling Procedures. The purpose of these slides is to demonstrate recommended sampling techniques. This presentation includes: supplies.
Introduction to Biohazards: Risk Management
Chapter One Basic Concepts in Refrigeration Basic Concepts in Refrigration1.
States of Matter and Phase Change. Phase Change Diagram.
MODULE “PROJECT MANAGEMENT AND CONTROL” SAFETY ASSESSMENT DURING DECOMMISSIONING SAFE DECOMMISSIONING OF NUCLEAR POWER PLANTS Project BG/04/B/F/PP ,
Changes of State Chapter 3 Section 2. Changing State By removing or adding energy, a substance can lose or absorb energy, its temperature can change,
What Employees Should Know Division of Risk Management State of Florida Loss Prevention Program.
Program Objectives n Define “Decontamination”. n Identify the steps in the decon process. n Demonstrate, by building, a decontamination reduction zone.
Environmental Safety 7.31 Safety in the workplace
Asbestos Safety Today’s topic is Asbestos Safety. This training is required by OSHA’s Asbestos Standard (29 CFR ). You will learn: About the dangers.
IAEA International Atomic Energy Agency. IAEA Dr. Abraham Gregorio de Rosa,Sp.Rad Radiologist in HNGV Dili, Timor Leste 2 Perspectives on regulatory models.
adiation safety management practices in 19th preventative maintenance of Kori unit 4 and future plans.
Mercury Spills and Cleanup Procedures Prepared by: Sarah Neumann Date: 03/08/04.
Space Suits By Aidan, Chandler, Matt and Riley
The Improvement of ALARA for the Steam Generator Maintenance Radiation Safety Department The 3 rd Plant, Ulchin Nuclear Power Site.
Reference: Diversified Health Occupations. Required by many health care facilities To be worn when lifting or moving Effectiveness is controversial, reminds.
Chain of infection 1 Prof. Hamed Adetunji. Course Overview At the end of this lecture and the activities that follow, student will be able to: List the.
Health and Safety Unit 3 Sophie Bevan. COSHH What does it stand for? ‘The Control of Substances Hazardous to Health’ Regulations (2002) What does it.
RESPIRATORY TRAINING. Objectives + Why are respirators are necessary + Capabilities & Limitations + Inspecting & Maintaining + Medical Clearance & Fit.
Gasunie is one of the biggest gas infrastructure companies in Europe. Within the company, we give safety the highest priority; it forms the basis of our.
Confined Spaces - General. Confined Space-General + Many, or perhaps even most, workplaces have something on the premises that would be correctly termed.
Hierarchy of Hazard Control
States of Matter Phase Change
Program Objectives Define “Decontamination”.
Natural activity and inhalation problems Wim Erkens (Thermphos)
Radiation Safety Management
Occupational Radiation Protection during High Exposure Operations
ALARA Programs & Occupational Dose Trend in Wolsong NPP
RADON Seamus Doyle Health & Safety Manager.
Sewage Treatment.
Gasunie is one of the biggest gas infrastructure companies in Europe
NRC Event Number – Event Date
The Improvement of ALARA for the Steam Generator Maintenance
Disaster Site Worker Safety
Presentation transcript:

RMS alarm under IHA decontamination Shin-Kori Nuclear Power Plant Korea Hydro & Nuclear Power

INTRODUCTION During the Operation, Occurring the Radiation Particle Appropriate Protection Dose reduction Protection from Internal Exposure As Low As Resonably Achievable

Title : IHA Cleaning operation Period : ~ Purpose : Removal of the foreign substance attached to IHA Operation personnel : 12person INTRODUCTION

WORK PLACE refueling pool area S/G cavity B S/G cavity A UCSA & upper Air Plenum Area P/H E/H IHA storage Area

Dry Ice Cleaning Theory

1. Sublimate Material 2. Carbon Dioxide Created by Compressing and Cooling 3. Liquefied At a Low Temperature 4. Sublimation as to supply heat to the surround and foreign objects fall as expended Dry Ice Features

Work Procedure 1. Spray DryIce on the IHA 2. The operator wears a mask 3. Work environment Spatial Dose = 5μSv/hr, No airborne particle 4. Work with the Radiation Safety Manager

Attached Boric acid

Cleaning of Boric acid

LCSA Cleaning Cleaning internal IHA

Radiation Monitor Alarm During the Dryice spray, Alarm occurs in the Radiation Monitoring System(RMS) The alarm Caused by Radioactive particle Workers complete the decontamination, and leave the workplace Airsampling is Performed, Checking Exposure Radioactive Particles blow into the air with the dryice

RMS Alert / High

RMS Line Drawing

Precaution

Precaution 1. Tent is installed in the workspace 2. Workers are wearing a mask 3. Discharged to the outside from inside the tent through the air ventillation 4. More Clothes on the outside, In order to prevent additional contamination

Results 1. Workers are not internal Exposure 2. Total External Dose = 0.9man-mSv(total : 10person) This Dose is due to the spatial dose 3. IHA thoroughly cleaned 4. Radiation Monitoring System was normal operation

Comparison on decontamination Before work / After work

Conclusion 1. Radioactive Particle Floats in the Air. It causes Internal exposure. 2. Maybe necessary Paricles occuring in the workplace should not be entered into the human body 3. IMA cleaning need something like the size of the tent because of the size and installed to perform the operation.