KX-TDA200/100 System (Production Version 2.02)

Slides:



Advertisements
Similar presentations
Introducing the Panasonic KX-TD500
Advertisements

KX-TDE and KX-NCP DSP Impact, August 2010, V1.0 EVERY CALL MATTERS KX-TDE and KX-NCP Series OneNet.
EVERY CALL MATTERS NCP500 Express New Business Editions NCP500X/V New Business Editions v1.0, Nov
Confidential1 Panasonic Communications Co., Ltd. Office Network Company Edition Sep., 2005 Chapter 2 System Capacities / Resources KX-TDA600 System.
Product Technical Document
TDE600 v3 | DSP Impact, Oct Presentation Ver. 1.0 EVERY CALL MATTERS SYSTEM ENHANCEMENTS IMPACT ON DSP KX-TDE600 v3.
KX-NS8188 E1 Adapter KX-NS8290 PRI Adapter Product Information
NS1000 Version 2 Document for SE and Sales Training
KX-TDE100/200 System (Version 1.0)
KX-NS1000 Version 2 Call Distribution.
KX-TDE/NCP Version 8 Product Information
KX-NS1000 PBX to PBX Networking For step by step : 16 May, 2012.
Feature Introduction for sales
Technical Training of New Features
NS1000 V3.0 - System Resource and Peripheral Incensement -
KX-TDE600 Pure IP Telecommunication System
KDX 30/60 System.
Agenda Introduction System Overview Product Proposition
1 TDE NCP Version 5 Product Information. 2 Enough capacity when employee increases in future KX-TDE/NCP Version 4 IP Phone Max.128 Additionally Call Center.
V-SIPGW to V-SIPGW Connection
Unified-PCMC Ver. 7 TDA100D ver. 5.1 support TDE/NCP ver. 4.2 support
Panasonic Communications Solutions Group Why Panasonic?
KX-TDE100/200 System (Version 1.0)
New Product KXTDA30KXTDA30. TDA30 Strategy Maximum Port Maximum Trunk Maximum Extension TDA30 32 (+4 IP) The CCU is supplied 0 lines, 4 SLT.
KX-TVM50/200 VM Integration with TDA system
Document for Technical and Sales Training KX-NS300 Basic Specification
KX-TDA200/100 System (Ver.2.0) Chapter 6.0 Enhanced Items
1 Speaker Name: System Overview Detailed Version for Sales Engineers Network Communications Platform.
Installing Offline configurator
TDA100D Contents 1 Target Customer
Proposed TDA Firmware Enhancements
KX-NCP1000 KX-NCP500 MPR V1.0 Not Final Not Final 25 Aug. 2008
Panasonic Communications CO.,LTD.
Hybrid IP PBX.
Legacy-GW Features Rev Jan., 2013.
Panasonic Communications Co., Ltd. Communication Network Company
New Features/Functions Ver.3
New Features/Functions Ver.4 (Edition-7)
Voice Processing Systems KX-TVM50AL KX-TVM200AL Panasonic delivers new levels of communication ease and efficiency to help business to be more productive.
New Hardware – Peripheral - 1
2. Fax Server (Unified Message)
KX-TDE100/200 System (Version 1.0)
Business type Education Institutions No.P019 Problem 1 These days, we hear a lot about people trespassing on school property and want to manage this risk.
Confidential1 Panasonic Communications Co., Ltd. Office Network Company Edition th July, 2007 Chapter 9 Other Functions (2) KX-TDE100/200 System.
Confidential1 Panasonic Communications Co., Ltd. Office Network Company Edition th July, 2007 Chapter 2 General Installation Procedure KX-TDE100/200.
KX-TDA600 System (Product Version 2.01)
Understanding the TDE Series 2009 Edition KX-TDE Hybrid IP PBX Features Distribuidor Autorizado Part 2 Dec-2009.
KX-NS1000 Basic Specification
Unified PC Maintenance Console (PCMC) - 1
NS series V4.2 - Summary - Rev Mar., 2015.
KX-TDA600 System (Product Version 2.01)
Unified PC Maintenance Console
Confidential1 Panasonic Communications Co., Ltd. Office Network Company Edition th July, 2007 Chapter 6 High Density CS KX-TDE100/200 System (Version.
KX-TDE600 Updated Information 1. MEC (Memory Expansion Card) - MEC-2M initially mounted on MPR - Optional MEC-6M (TDE0105) to increase the logging buffer.
Confidential1 Panasonic Communications Co., Ltd. Office Network Company Edition th July, 2007 Chapter 10 FAQ KX-TDE100/200 System (Version 1.0) KX-TDE100/200.
1 1 TDE KX-TDE Free Slot (Physical slots) Support TDE MPRV.2 & TDA MPRV.5 Features - Supporting ESVM2/4 card (High quality recording, DISA-AA/Queuing.
Document for Technical and Sales Training KX-NS500 Basic Specification
KX-TDA/TDE/NCP System
New BTS Products Sales Training
NSX1000/2000 V2.0 - Simultaneous Maintenance -
KX-HTS Step by Step Guide SIP Trunk
Document for Technical and Sales Training KX-NS700 Basic Specification
KX-HTS Technical Note FAQ : Frequently Asked Questions
KX-NS300 Basic Specification October 14, 2017 This document explains basic specification of KX-NS300 version 1. It is recommended to know basic specification.
KX-NS1000 Step by Step Guide Network Survivability
KX-NS1000 Step by Step Guide PBX to PBX One-look Network Stacking Card
KX-NS Step by Step Guide Activation Key
KX-NS Step by Step Guide SIP Trunk to SIP Trunk
Panasonic System Networks PBX SE team
KX-NS Step by Step Guide Initial Setup
Presentation transcript:

KX-TDA200/100 System (Production Version 2.02) Chapter 1 System Capacity and System Resources Panasonic Communications Co., Ltd. Office Network Company Edition 1.0 31 May, 2006 Confidential 1

Index 1. System Capacity 2. System Resources

Function 1. System Capacity

1.System Capacity(1/14) Full free slot for TDA100/200 < Card (1/3) > OLD NEW (Ver.3) Line Type TDA100 TDA200 Line Type TDA100 TDA200 Trunk 4 8 Trunk 6 8 Extension 4 8 Extension 6 8 Total 5 10 Total 6 11 free slots 1 to 10 free slots 1 to 11 free slots 1 to 5 free slots 1 to 6

1.System Capacity(2/14) Card Type Maximum Number KX-TDA100 KX-TDA200 LCOT / DID / E&M / BRI 6 8 T1 / E1 / PRI 4 IP-GW DHLC / DLC / SLC / IP-EXT CSIF CTI-Link 1 MEC RMT OPB3 PSU-S 64 x PSU-M 128 PSU-L 512 Terminal Equipment Type KX-TDA100 KX-TDA200 W/O MEC W/I MEC EXT 64 160 128 256 SLT 96 T76 DPT T7560/65 DPT Other DPT 32 APT 24 IP-PT DSS Console 8 CS PS VM 2 Door phone 16 Door opener Ext. Sensor Ext. Relay

1. System Capacity(3/14) < Card (2/3)> TDA100 New Old Card Type PRI, E1, T1, IPGW, CSIF Max. 4 Max. 2 Max. 2 cards for PRI/E1/T1/IPGW/CSIF Max. 4 cards for PRI/E1/T1/IPGW/CSIF New Old

1. System Capacity(4/14) < Card (3/3)> TDA30 Card Type New Old Yes No

1.System Capacity(5/14) < Port > TDA100 w/o MEC(1/2) KX-TDA100 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 32 Main Unit TDA100 KX-T76xx DPT (D-XDP) 32 Other DPT Card Installation KX-T7640 DSS Console Slot 1 DLC16 Other DSS Console Slot 2 DLC16 APT Slot 3 LCOT16 Cell Station for DLC/DHLC card Slot 4 LCOT16 Cell Station for CSI/F card Slot 5 LCOT16 IP-PT * Slot 6 LCOT16 SLT * N/A N/A Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH N/A Second VM Unit 0 CH N/A *) PSU type is not effect by SLT/IP-PT numbers. Result Total Power Factor : 64 PSU Type : Power-S Total PT+SLT : 64 MEC Card : Not Required Total:64+64=128 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

1.System Capacity(6/14) < Port > TDA100 w/o MEC(2/2) KX-TDA100 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 32 Main Unit TDA100 KX-T76xx DPT (D-XDP) 32 Other DPT Card Installation KX-T7640 DSS Console Slot 1 DLC16 Other DSS Console Slot 2 DLC16 APT Slot 3 PRI Cell Station for DLC/DHLC card Slot 4 PRI Cell Station for CSI/F card Slot 5 PRI IP-PT * Slot 6 PRI SLT * N/A N/A Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH N/A Second VM Unit 0 CH N/A *) PSU type is not effect by SLT/IP-PT numbers. Result Total Power Factor : 64 PSU Type : Power-S Total PT+SLT : 64 MEC Card : Not Required Total:64+120=184 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

1.System Capacity(7/14) < Port > TDA200 w/o MEC(1/2) KX-TDA200 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 64 Main Unit TDA200 KX-T76xx DPT (D-XDP) 64 Other DPT Card Installation KX-T7640 DSS Console Slot 1 DLC16 Other DSS Console Slot 2 DLC16 APT Slot 3 DLC16 Cell Station for DLC/DHLC card Slot 4 DLC16 Cell Station for CSI/F card Slot 5 LCOT16 IP-PT * Slot 6 LCOT16 SLT * Slot 7 LCOT16 Slot 8 LCOT16 Total Port Number of KX-TV (DPT Integration) Slot 9 LCOT16 First VM Unit 0 CH Slot10 LCOT16 Second VM Unit 0 CH Slot11 LCOT16 *) PSU type is not effect by SLT/IP-PT numbers. Result Total Power Factor : 128 PSU Type : Power-M Total PT+SLT : 128 MEC Card : Not Required Total:128+112=240 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

1.System Capacity(8/14) < Port > TDA200 w/o MEC(1/2) KX-TDA200 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 64 Main Unit TDA200 KX-T76xx DPT (D-XDP) 64 Other DPT Card Installation KX-T7640 DSS Console Slot 1 DLC16 Other DSS Console Slot 2 DLC16 APT Slot 3 DLC16 Cell Station for DLC/DHLC card Slot 4 DLC16 Cell Station for CSI/F card Slot 5 PRI IP-PT * Slot 6 PRI SLT * Slot 7 PRI Slot 8 PRI Total Port Number of KX-TV (DPT Integration) Slot 9 First VM Unit 0 CH Slot10 Second VM Unit 0 CH Slot11 *) PSU type is not effect by SLT/IP-PT numbers. Result Total Power Factor : 128 PSU Type : Power-M Total PT+SLT : 128 MEC Card : Not Required Total:128+120=248 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

1.System Capacity(9/14) < Port > TDA100 with MEC(1/4) KX-TDA100 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 64 Main Unit TDA100 KX-T76xx DPT (D-XDP) 64 Other DPT Card Installation KX-T7640 DSS Console Slot 1 DLC16 Other DSS Console Slot 2 DLC16 APT Slot 3 DLC16 Cell Station for DLC/DHLC card Slot 4 DLC16 Cell Station for CSI/F card Slot 5 IP-EXT16 IP-PT * 32 Slot 6 IP-EXT16 SLT * N/A N/A Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH N/A Second VM Unit 0 CH N/A *) PSU type is not effect by SLT/IP-PT numbers. Result Total Power Factor : 128 PSU Type : Power-M Total PT+SLT : 160 MEC Card : Required Total:160+0=160 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

1.System Capacity(10/14) < Port > TDA100 with MEC(2/4) KX-TDA100 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 64 Main Unit TDA100 KX-T76xx DPT (D-XDP) 64 Other DPT Card Installation KX-T7640 DSS Console Slot 1 DLC16 Other DSS Console Slot 2 DLC16 APT Slot 3 DLC16 Cell Station for DLC/DHLC card Slot 4 DLC16 Cell Station for CSI/F card Slot 5 LCOT8/16 IP-PT * Slot 6 LCOT8/16 SLT * N/A N/A Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH N/A Second VM Unit 0 CH N/A *) PSU type is not effect by SLT/IP-PT numbers. Result Total Power Factor : 128 PSU Type : Power-M Total PT+SLT : 128 MEC Card : Required Total:128+32=160 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

1.System Capacity(11/14) < Port > TDA100 with MEC(3/4) KX-TDA100 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 64 Main Unit TDA100 KX-T76xx DPT (D-XDP) 64 Other DPT Card Installation KX-T7640 DSS Console Slot 1 DLC16 Other DSS Console Slot 2 DLC16 APT Slot 3 DLC16 Cell Station for DLC/DHLC card Slot 4 DLC16 Cell Station for CSI/F card Slot 5 PRI IP-PT * Slot 6 PRI SLT * N/A N/A Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH N/A Second VM Unit 0 CH N/A *) PSU type is not effect by SLT/IP-PT numbers. Result Total Power Factor : 128 PSU Type : Power-M Total PT+SLT : 128 MEC Card : Required Total:128+60=188 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

1.System Capacity(12/14) < Port > TDA100 with MEC(4/4) KX-TDA100 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 32 Main Unit TDA100 KX-T76xx DPT (D-XDP) 32 Other DPT Card Installation KX-T7640 DSS Console Slot 1 DLC16 Other DSS Console Slot 2 DLC16 APT Slot 3 PRI Cell Station for DLC/DHLC card Slot 4 PRI Cell Station for CSI/F card Slot 5 PRI IP-PT * Slot 6 PRI SLT * N/A N/A Total Port Number of KX-TV (DPT Integration) N/A First VM Unit 0 CH N/A Second VM Unit 0 CH N/A *) PSU type is not effect by SLT/IP-PT numbers. Result Total Power Factor : 64 PSU Type : Power-S Total PT+SLT : 64 MEC Card : Not Required Total:64+120=184 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

1.System Capacity(13/14) < Port > TDA200 with MEC(1/2) KX-TDA200 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 128 Main Unit TDA200 KX-T76xx DPT (D-XDP) 128 Other DPT Card Installation KX-T7640 DSS Console Slot 1 DLC16 Other DSS Console Slot 2 DLC16 APT Slot 3 DLC16 Cell Station for DLC/DHLC card Slot 4 DLC16 Cell Station for CSI/F card Slot 5 DLC16 IP-PT * Slot 6 DLC16 SLT * Slot 7 DLC16 Slot 8 DLC16 Total Port Number of KX-TV (DPT Integration) Slot 9 LCOT First VM Unit 0 CH Slot10 LCOT Second VM Unit 0 CH Slot11 LCOT *) PSU type is not effect by SLT/IP-PT numbers. Result Total Power Factor : 256 PSU Type : Power-L Total PT+SLT : 256 MEC Card : Required Total:256+48=304 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

1.System Capacity(14/14) < Port > TDA200 with MEC(2/2) KX-TDA200 Power Supply Unit & MEC Calculation Tool Input Total Number of Telephone / CS PBX Selection KX-T76xx DPT 128 Main Unit TDA200 KX-T76xx DPT (D-XDP) 128 Other DPT Card Installation KX-T7640 DSS Console Slot 1 DLC16 Other DSS Console Slot 2 DLC16 APT Slot 3 DLC16 Cell Station for DLC/DHLC card Slot 4 DLC16 Cell Station for CSI/F card Slot 5 DLC16 IP-PT * Slot 6 DLC16 SLT * Slot 7 DLC16 Slot 8 DLC16 Total Port Number of KX-TV (DPT Integration) Slot 9 PRI First VM Unit 0 CH Slot10 PRI Second VM Unit 0 CH Slot11 PRI *) PSU type is not effect by SLT/IP-PT numbers. Result Total Power Factor : 256 PSU Type : Power-L Total PT+SLT : 256 MEC Card : Required Total:256+90=346 Power-S/M is for KX-TDA100. Power-M/L is for KX-TDA200. Power-M supports up to 128 points. Power-S supports up to 64 points.

Function 2. System resource

2.System Resources (1/4) TDA100/TDA200 TDA30 Resources New Old Network DSS Key(TDA0920) 250 32 Quick Dial 80 (4 digits) 80 (4 digits) Quick Dial with MEC card 80(4digits)+4,000(8digits) 80 (4 digits) ICD Group 128 64 ICD Group Member 32 32 ICDG Member(sales C mode) 128 TDA30 Quick Dial with MEC card 80(4digits)+1,000(8digits) 80 (4 digits)

2.System Resources (2/4) Network DSS Key Network PBX ID up to 8 NDSS TDA0920 is required. Network DSS Key Network Data Transfer NDSS Key Table Network PBX ID up to 8 NDSS up to 250

2.System Resources (3/4) Quick Dial expansion Up to 80 without MEC With MEC Basic Memory MEC Memory Up to 80 without MEC Up to 4,000 with MEC

2.System Resources (4/4) ICD Group expansion Sales Company Level Miscellaneous Enable 128 extensions ICD Group ICD Group Member 128 ICD groups 128 extensions