ASAB New Additions Extended Bypass Models Ethernet Modules Remote Control Panel
Extended Bypass ASAB Soft Starters New Range 9 Models 255A ~ 1000A 2 Frame Sizes 2 Voltage Range 200 ~ 525 VAC 380 ~ 690 VAC Protection IP20 with finger-guard kit IP00 Approvals
Extended Bypass ASAB Soft Starters Advantages Lower installed cost Save on labour costs Smaller total solution footprint Self-contained phase arms Easy to service Save training Little heat-dissipation during run Prolong lifetime
ASAB G3 Frame Size 255A ~ 425A 255A ~ 425B Frame Size: Top or bottom inputs, outputs accessible from bottom IP20 Finger Guard kit available
ASAB G4 Frame Size 500A ~ 1000A 500A ~ 1000B Frame Size: Inputs and outputs accessible from top and bottom Door panel for easy access IP20 Finger Guard kit available
Ethernet Modules New Range EtherNet/IP Modbus TCP Profinet Easy installation via top and bottom retaining clips Compatible with ASAC & ASAB soft starters Each module features two Ethernet ports for easy daisy- chain configuration Enclosure, connection to starters same as the fieldbus communications modules
Remote Control Panel Full graphical LCD display Replicate built-in ASAB display functionality and contents Operate in parallel to built-in ASAB display and interface Parameter Upload/Download capable Transfer parameters between ASAB soft starters Can be removed and attached while soft starter is operational
Remote Control Panel Dedicated RCP connection on ASAB soft starters ASAB 23A ~ 220A ASAB 255A ~ 1600A Remote mountable keypad with up to 3m cable IP65 capable (with mounting kit provided)