SOLDIER BIOLOGICAL CHEMICAL COMMAND (SBCCOM)

Slides:



Advertisements
Similar presentations
January 2012International Medcom, Inc How to Use the Radalert 100.
Advertisements

January 2012International Medcom, Inc How to Use the Inspector Alert.
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
(PLEASE SWITCH TO THE SLIDE SHOW MODE)
Improved Chemical Agent Monitor
HOW TO PMCS AND OPERATE RADIOLOGICAL DETECTOR
TLA. Replacing The Battery On the Back of the pager press in this button while moving the door away from the pager, then lift up. On the Back of the pager.
Training for Radiation Pagers Training for Radiation Pagers Berkeley Nucleonics Corporation 2955 Kerner Blvd. San Rafael, CA
 Description of PressurePro System  Identify system components  Display and Operational Modes  Sensor alerts  Checking of tire pressures  Manual.
Engineer Training Rear Operation Unit TJ8300 / TJ8500 Rear Operation Unit.
How to Use the Microphone System It’s as Simple as 0, 1, 2, 3!
March 2005 International Medcom How to Use the Inspector.
March 2006 Berkeley Nucleonics Corporation How to Use the palmRAD 907.
Syringe Pumps. Topics  Diagrams  Principles of Operation  Applications  Safety  Operation  Preventive Maintenance  Common Failure Modes  Troubleshooting.
© 2008 Masimo Corporation Includes a review on Carbon Monoxide Poisoning For Emergency Responders V.8 1 May 2011 Monitoring CO Poisoning with the Rad-57.
Radiological Equipment - Basic. Objectives For each radiation detection instrument: −Identify capabilities, limitations, and primary uses −Identify the.
Familiarization and Operation
SUPER PASS II Personal Alert Safety System Charles Montgomery Fire Chief Course Developed by Lt. Ricky Phillips Sam Johnson Assistant Chief.
Clean Air Box Usage & Care CABs RAMs CO Monitors.
MySOS User Guide.
MSA - ALTAIR 4X Gas Meter.
United States Army Combined Arms Center Troubleshooting TBC Workstation.
AccuMax Single Point Injection Operation (See Installation and Operation Manual for detailed instructions)
5:47 1: Default Clock State PM Alarm off, time set to 5:47PM. Hour
Radiological Equipment - Advanced. Objectives For each radiation detection instrument: −Perform advanced operating procedures −Become familiar with software.
Lesson Title DAGR Troubleshooting Lesson Number
DataLogger Operation - 1 DataLogger ® Operation Procedures.
2001, 2002 & 3012 Series Operation 2001, 2002 & 3012 Series Operation (See Installation and Operation Manual for detailed instructions)
1 Batteries & Battery Clips – Setup for Operation Follow these steps to prepare for battery-powered operation: 1.Place two battery clips, two charged batteries.
The Impulse “Switch” 1Daniel Overman DIS5274/10/2010.
Created by Curt Harrell & Jesse Kuzy for. Why are Fire Alarms Important?  If the fire is small enough to be extinguished with a hand-held fire extinguisher,
New Equipment Training (NET) Overview
FoamPro Features & Benefits. 139 FoamPro Systems 1600 Series 2000 Series 3012 Model AccuMax Series.
Alarm clock Pro plus | Introduction Pro plus The alarm clock that shows you when the mobile rings.
MySOS Device User Training
The Accentuator A Wireless Annotator on Steroids Projection Perfection A Wireless Remote That Does it All Designed for Professionals.
International Medcom How to Use the Radalert 50 March 2005 International Medcom
The Most Failsafe Sump Pump System Ever Manufactured.
Self Guided Tour of TagMate™QC Display Tag DATA Tag Data: PRINT TagMate™QC SETUP Display STATS Tags: START and READ SEND All Data to PC Additional Capabilities.
© 2008 Masimo Corporation RAD-57 EMS Carry Case Lightweight: 13 oz. Small: 6.2” x 3.0” x 1.4” Portable: operates on 4 “AA” batteries Supplied with high-visibility,
PN: TM rev:3 Administration Training. PN: TM rev:3 Course Overview Logging On Menu Screens »Edit Functions Options Configuration Users »View.
Model 1621M Trainer’s Guide. General Overview Model 1621M is a Geiger Meuller based Personal Radiation Detector (PRD) Complies with ANSI Used for.
MX6 iBrid Multi-Gas Monitor
MSA Five Star 4-Gas Monitor Air Monitoring Instrumentation.
TM Revision 2 Preventive Maintenance Course.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
AGENDA - TASK, CONDITIONS, STANDARDS - PACKAGE AND COMPONENTS - FRONT PANEL DISPLAY - ATTRIBUTES - USING THE RADIO - BATTERY OPERATIONS - HEADSET ILLISTRATION.
DLP LCD PANEL Programming
1 Verizon Technology California Public Utilities Commission Rulemaking Backup Power at the Customer Premises Technical Workshop June 5th, 2007.
INDEX WELCOME DISPLAY DEFAULT DISPLAY MAIN DISPLAY SYSTEM LAYOUT – P105 to P104 SYSTEM LAYOUT – P109 to P106 ROOMS P-109 to P-104 DISPLAY CHANGE SET POINTS.
BMC Medical Co., Ltd. Nov Training Course. 1 Table of Contents 1. CATALOGUE 2. INSTALL& DISASSEMBLE 3. SET UP.
The Sentry Personal Alarming Dosimeter and Rate Meter.
Detecting Instruments (For Contest Work Only) MSA Passport Personal Alarm.
MB99 Improved Chemical Agent Monitor (ICAM) SOLDIER and BIOLOGICAL, CHEMICAL COMMAND (SBCCOM) New Equipment Training (NET) Overview Name Project.
Electronic Dosimeter Canberra Mini-Radiac
Service Section Technical Training December 2005.
1. 2 INDEX MAIN DISPLAYS3-4 SYSTEM LAYOUT 5-6 ROOM P-109 DISPLAY7 ROOM P-108 DISPLAY8 ROOM P-107 DISPLAY 9 ROOM P-106 DISPLAY 10 ROOM P-105 DISPLAY 11.
InnoSys Park Brake Tool Master Control Panel Screens Revision A, 12Dec /12/20071.
Spring Hill Assembly1 InnoSys Park Brake Tool Master Control Panel Screens 1 3-Mar-2008.
16 February 2016 Connected Worker. © 2015 by Honeywell International Inc. All rights reserved. Connected Worker 1 Real Time Gas Detection, Real Time Telematics.
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
YEARLY MAINTENANCE. CLEANING OF CHARGER.
New Equipment Training (NET) Overview
Intro and T1 Troubleshooting
Command Maintenance Discipline Program (CMDP) Overview
How to Use the Inspector Alert
Command Maintenance Discipline Program (CMDP) Overview
Film badge: Measure and record radiation exposure due to gamma rays, X-rays, and Beta particles. Permanent record Cheaper Energy dependence Fading film.
Film badge: Measure and record radiation exposure due to gamma rays, X-rays, and Beta particles. Permanent record Cheaper Energy dependence Fading film.
Presentation transcript:

SOLDIER BIOLOGICAL CHEMICAL COMMAND (SBCCOM) Radiac Product Manager Ed Groeber DSN 987-5159

Overview Program Description Remove and install batteries Self check and turn on Rate and Dose modes Setting alarms Sleep mode Backlight Operator Maintenance

Simplified Operation Card System & Components Radiac Set AN/UDR-13 Case TM 11-6665-364-12 Simplified Operation Card Batteries

Additional Information Mission Detect and measure nuclear radiation from fallout and nuclear detonations Key Events Production Contract Award: May 96 First Delivery April 98 Due January 99 Team PM NBC Defense SBCCOM, Nuclear Research Corp., Dover, NJ User U.S. Army Capabilities Combined ratemeter and tactical dosimeter Settable autio and visual rate and dose alarm Measures doserate from .1-999cGy/hr Measures total dose from .1-999cGy Improvements over IM-93: Measures prompt dose including neutrons Has alarms and also measures rate Does not require separate charger Backlit display Rugged, reliable, and accurate

Batteries 4 AAA cells What happens when batteries replaced or installed? Low battery indication Install according to procedure in manual Do not force batteries into compartment 1) The AN/UDR-13 is powered by 4 1.5V AAA batteries. 2) When the batteries are replaced or installed, the AN/UDR-13 will be defaulted to SLEEP mode. To exit SLEEP mode, press the ON/OFF button to return the AN/UDR-13 to the Rate display. 3) A low battery indication (a “BAT” or “b”) on the display window of the AN/UDR-13 lets the user know it is time to replace the batteries. 4) Install/replace the batteries according to the procedure in the Operator’s Manual. Make sure the new batteries are inserted straight into the battery box. Ensure that the new batteries are fully seated before attempting to close the battery door. DO NOT force the batteries into the battery box. If one or more of the batteries are sticking up above the others, remove the batteries and re-insert them so that they are straight. DO NOT try to force the lid on the battery compartment shut.

Self Check and Turn On ON/OFF button CLR/TEST for Self Check 1) The ON/OFF button is used to turn ON and OFF the Radiac Set. * To turn the unit ON, press and hold the ON/OFF button until a series of numbers (0-4) start to be displayed. You can release the button as soon as the first number appears. This will be followed by a full display. * To turn the unit OFF, press the ON/OFF button until the word “OFF” followed by three dashes appears. Then release the ON/OFF button. 2) The AN/UDR-13 has a built-in self check function that determines whether it is operating normally or if any fault occurs. CLR/TEST button is used for this purpose. Press and hold the CLR/TEST button until the entire display is shown (888 plus all of the icons). The UDR-13 will proceed through an automatic self-check. If it terminates in a flashing “9”, the unit is operating correctly. After 10 seconds, the unit will revert to the rate mode. If a flashing “0” is shown, the unit has a fault. Turn it off and then back on and try the self-test again. If the test ends in a flashing “0”, notify your supervisor. The CLR/TEST button is also used to change the alarm set point for Rate and Dose.

Rate and Dose Modes Rate button Dose button Default to rate mode 1) The RATE button is used to put the AN/UDR-13 into the RATE mode. Rate is the instantaneous amount of radiation being measured. The combination of the RATE button and the ALARM button is used for Rate Alarm Setting. The RATE button when combined with the ON/OFF button will put the AN/UDR-13 into SLEEP mode. 2) The DOSE button is used to put the AN/UDR-13 into the DOSE mode. Dose is the accumulated amount of radiation measured or absorbed over a period of time. Press the dose button until the DOSE icon appears at the top of the display and brackets are displayed. After a few seconds, the total dose will be displayed. The combination of the DOSE button and the ALARM button is used for Dose Alarm Setting. 3) After ten seconds, the AN/UDR-13 will be defaulted to Rate mode after the dose is read.

Setting Alarms ALARM + RATE Button ALARM + DOSE Button Set values Set Audible, Visual, Both or none How do I test alarm without radiation source? The AN/UDR-13 has an alarm feature to permit selection of Rate or Dose Alarms and the level at which these alarms are activated. 1) The combination of the RATE button and the ALARM button is used for Rate Alarm Setting. 2) The combination of the DOSE button and the ALARM button is used for Dose Alarm Setting. 3) Set values are the threshold levels of Rate and/or Dose to be set for these alarms to activate. 4) The alarm includes audible and distinct visual features which are visible day and night. There are also switching functions for “visual”, “audio”, “visual and audio”, or none by sequentially pressing the ALARM button. 5) The alarm can be tested by setting the Rate and/or Dose alarms to zero.

Sleep Mode >1000 hours of battery life Wakes up every 5 minutes Will alarm if preset levels exceeded Will alarm on prompt radiation Setting and un-setting sleep mode 1) To preserve the battery life, the AN/UDR-13 includes a function called SLEEP mode that will extend the battery life from approximately 100 hours to approximately 1000 hours. The AN/UDR-13 passively monitors radiation while in SLEEP mode. 2) When in SLEEP mode the AN/UDR-13 wakes up every 5 minutes to display the current Rate then goes back to SLEEP mode. 3) If either alarm is exceeded, the AN/UDR-13 will go into the normal operating mode and the appropriate alarm will sound. In addition, the AN/UDR-13 will wake up at any time it is exposed to a nuclear burst. 4) The AN/UDR-13 can be set to enter the SLEEP mode or it can be unset to discontinue the SLEEP mode. To enter the SLEEP mode when the unit is on, press the RATE button and hold it. While holding it, press the ON/OFF button until the display shows “SLP” followed by “---”. Release the buttons and the display will show the SLEEP icon at the top of the display. To exit sleep mode, press the ON/OFF button until a “0” and the alarm icons on the left side of the display appear. Release the button and the unit will return to the RATE mode.

Backlight LIGHT button Why can’t I see the light? 1) The AN/UDR-13 has a back light feature that allows the operator to see the display in the dark. Press and release the LIGHT button and the display light will stay on for approximately 6 seconds. 2) The light can not be seen in daylight or in a well-lit environment because the UDR-13 is equipped with secure-lighting. Secure-lighting ensures the display will not emit excessive light that can be readily detected in the field by image intensifier devices and that it is compatible with night vision goggles. Cup your hands around the display window or test the UDR-13 in a darkened room to be able to observe the display light.

Operator Maintenance Cleaning Inspection Battery replacement Replace carrying case The Operator Maintenance of the AN/UDR-13 includes cleaning, inspection, battery replacement, carrying case replacement, etc. 1) Use a clean soft cloth to remove dust, moisture, and loose dirt from the outside surfaces of the Radiac Set or Set components. It may be washed with soap and water. 2) Inspect to observe any visual damage to the AN/UDR-13. Inspect the battery cover gasket for deterioration and the battery contacts for corrosion. 3) Replace the batteries when the low battery indication appears on the display window of the AN/UDR-13. 4) When the carrying case is worn out or damaged, replace it with the new one.