Department of Radiation Oncology Henry Ford Health System

Slides:



Advertisements
Similar presentations
Orthogonal and Least-Squares Based Coordinate Transforms for Optical Alignment Verification in Radiosurgery Ernesto Gomez PhD, Yasha Karant PhD, Veysi.
Advertisements

In the past few years the usage of conformal and IMRT treatments has been increasing rapidly. These treatments employ the use of tighter margins around.
The Tomotherapy Experience at Advocate Good Samaritan Hospital
MAMMO QC – covered in week 8
Experience, Expertise and a Commitment to Excellence™
Copyright ©2008 Accuray, Incorporated. All rights reserved E CyberKnife ® Robotic Radiosurgery System Radiosurgery System Comparisons.
IGRT Prostate – the ADHB experience Nicola Gordon Imaging Specialist RT ADHB.
Varian _ Dynamic Targeting TM Image-Guided Radiation Therapy Scott Johnson, PhD Varian Medical Systems Palo Alto, California Varian _.
The TrueBeam System ™ Clinic Name Presenter’s name Clinic location
Alamance Regional Cancer Center 2012
Arizona’s First University. Feasibility of Image-Guided SRS for Trigeminal Neuralgia with Novalis.
Estimating 3D Respiratory Motion from Orbiting Views Rongping Zeng, Jeffrey A. Fessler, James M. Balter The University of Michigan Oct Funding provided.
1. The physics behind SBRT
COMPUTED TOMOGRAPHY - I RAD 365 CT - Scan
Results The measured-to-predicted dose ratio criteria used by the RPC to credential institutions is , however for this work, a criteria of
Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator Andrew J Reilly Imaging Physicist Oncology Physics Edinburgh Cancer.
بسم الله الرحمن الرحيم و قل رب زدنى علماً ﴿و قل رب زدنى علماً﴾ صدق الله العظيم.
Quality Control in Radiation Therapy, A New Concept: Dosimetry Check
Vertebral Fractures After Stereotactic Ablative Radiotherapy of Lung Tumors Todd A. Aguilera MD PhD 1, Nicholas Trakul MD PhD 2, David B. Shultz MD PhD.
Performance Analysis of an Optoelectronic Localization System for Monitoring Brain Lesioning with Proton Beams Fadi Shihadeh (1), Reinhard Schulte (2),
Safety Consideration Software limits on robot controller Limit switches on the robot “wrist” to prevent excess rotations Limit switches on the vertical.
External Beam Radiation Therapy Special Procedures
The external beam radiotherapy and Image-guided radiotherapy (2)
Kelly Younge, Ph.DKelly Younge, Ph.D Don Roberts, Benedick Fraass, Daniel McShan, and Martha Matuszak University of Michigan, Department of Radiation Oncology,University.
Software Development For Correction of Gradient- Nonlinearity Distortions in MR Images T.S. Lee, K.E. Schubert Computer Science CSUSB R.W. Schulte Radiation.
In vivo dosimetry Eirik Malinen Eva Stabell Bergstrand Dag Rune Olsen.
1 4D: Adaptive Radiotherapy & Tomotherapy Bhudatt Paliwal, PhD Professor Departments of Human Oncology & Medical Physics University of Wisconsin Madison.
Performance and Quality Improvement Session the SRS/SBRT Scientific Meeting 2014 May 10, 2014 Title Goes Here Must conform to HIPAA Standards Limit Presentation.
I. Introduction Objectives  To solve geometric problem(misalignment) in cone-beam computed tomography (CBCT) system.  To adjust X-ray focal spot using.
Application of a 2-D ionization chamber array for dose verification of dynamic IMRT with a micro-MLC Fujio ARAKI, PhD 1, S. TAJIRI 2, H. TOMINAGA 2, K.
Institute for Advanced Radiation Oncology
6. Clinical implementation and SBRT quality assurance
DEPT OF RADIATION ONCOLOGY Clinical Evaluation of a Novel 4D-CBCT Reconstruction Scheme Based on Simultaneous Motion Estimation and Image Reconstruction.
Araki F. Ikegami T. and Ishidoya T.
COMPUTED TOMOGRAPHY - I RAD 365 CT - Scan
Somvilai Mayurasakorn, MD. Division of Therapeutic Radiology and Oncology, Faculty of Medicine, Chiang Mai University Somvilai Mayurasakorn, MD. Division.
Outcomes of Stereotactic Ablative Radiotherapy (SABR) for a Second Primary Lung Cancer (SPLC): Evidence in Support of Routine CT Surveillance C. J.A. Haasbeek,
Stereotactic Radiosurgery (SRS)
The Role of Cyberknife Stereotactic Body Radiation Therapy in the Treatment of Localized Prostate Cancer David M. Spellberg M.D., FACS Naples Urology Associates,
Principles and Practice of Radiation Therapy
The Role of Cyberknife Stereotactic Body Radiation Therapy in the Treatment of Localized Prostate Cancer David M. Spellberg M.D., FACS Naples Urology Associates,
Carmel McDerby Clatterbridge Centre for Oncology, Merseyside,UK
Varian Medical Systems
A virtual simulator in an multivendor radiotherapy department, an overview of the commissioning process Geert Pittomvils, Lobke Mommaerts, Frederic Crop,
Rapid Arc Treatment Verification: post evaluation on Delta-4 and proposal of a new verification protocol G. Pittomvils 1,,L. Paelinck 1, T. Boterberg 1,
Pei Hailong X-RAD 225CX/SMART COMMISSIONING, QA AND FACILITIES MANAGEMENT.
A Clinical Audit in Stereotactic Radiotherapy Lucy Richley Bristol Haematology and Oncology Centre 8 th June 2007.
What is the volume of a hula hoop?
Technical Innovations and Patient Support in Radiation Oncology
SIMULATION CHECK LIST IMAGING PROTOCOL.
Martin J Murphy PhD Department of Radiation Oncology
Dr. Malhar Patel DNB (Radiation Oncology)
Impact of Obesity on Medical Imaging and Image-Guided Intervention
Treatment Plan Validation of the Xoft AXXENT™ X-ray Source
Extending intracranial treatment options with Leksell Gamma Knife® Icon™ Key Statements from Customer Perspective by University Medical Centre Mannheim.
Radiological Sciences Department Ph.D., Paris-Sud 11 University
Very High Energy Electron for Radiotherapy Studies
INTRODUCTION RESULTS DATA ANALYSIS DISCUSSION METHODS REFERENCES
LumiCal mechanical design, integration with LDC and laser alignment
Linac Commissioning Overview
An Investigation of the Effect of Window and Level Controls on the accuracy of the ExacTrac Patient Repositioning System Dan Goldbaum and Russell Hamilton.
Orthogonal and Least-Squares Based Coordinate Transforms for Optical Alignment Verification in Radiosurgery Ernesto Gomez PhD, Yasha Karant PhD, Veysi.
Volumetric Modulated Arc Therapy (VMAT) versus Intensity Modulated Radiation Therapy (IMRT) for Anal Carcinoma Heather Ortega, BSRT(T), CMD, Kerry Hibbitts,
Technical Innovations and Patient Support in Radiation Oncology
Novalis Frameless Radiosurgery
Thijs Perik, Jochem Kaas, Frits Wittkämper 
Add your title here Performance and Quality Improvement Session
Add your title here Performance and Quality Improvement Session
GHG meeting at ESTRO36 May, 2017
Circles
Presentation transcript:

Department of Radiation Oncology Henry Ford Health System Publishing Title: Evaluation of the Systematic Accuracy of Cutting Edge Technology for Stereotactic Radiosurgery Treatment  Session title: Physics 1 - Innovative Planning and Delivery Strategies Date/Time: 2014-09-16 13:00 Location: Room D-1 Monitor number: 3 Ning Wen Department of Radiation Oncology Henry Ford Health System 2799 W. Grand Blvd Detroit, MI48202

The Edge system at Henry Ford E: 6XFFF, 10XFFF 2.5XFFF, HD120MLC OSMS x 3 IR camera Calypso x 3 PerfectPitch® 6D Couch MV Detector aS1200, 43x43 cm2 Calypso

EDGE E2E Phantom (Prototype) Outer cube dimensions: 15 x 15 x 15 cm3, density 0.45 g/cm3 Trackable using kV, MV radiographic imaging (16x 5mm diameter BB’s made of ceramics Al2O3) CBCT (densities: 0.25, 0.45, 1.05 and 1.42 g/cm3) Calypso (Beacon® transponders are not removable) OSMS Interchangable inner cubes (7 x 7 x 7 cm3) Single film plane for all 3 orthogonal isocenter planes, density=1.05 g/cm3 Two orthogonal film planes, density=1.05 g/cm3 5 mm diameter tungsten BB in center (W-L test) Mechanical accuracy < 5/100 mm Image Courtesy from Varian

Winston Lotz Test Results Gantry Rotation Gantry-Collimator-Couch Rotation

Multiple Targets Single Isocenter Test Auto + Manual Auto   Central BB 56.5 mm BB 65 mm BB 92 mm BB Mean 0.30 0.44 0.52 0.47 Std 0.08 0.19 0.13 0.15 Max 0.71 0.84 0.65 Min 0.17 0.14 0.43 0.25   Central BB 56.5 mm BB 65 mm BB 92 mm BB Mean 0.56 0.51 0.62 0.63 Std 0.24 0.43 0.35 Max 0.84 0.80 1.18 Min 0.16 0.20 0.05

Summary Coincidence of isocenters of the imaging systems and Linac is within 1 mm. The localization accuracy of the Edge platform can achieve submillimeter level. The targeting accuracy for multiple lesions with shared isocenter is promising. However lesion size and the distance from the isocenter should be evaluated before planning. Other factors (CT, MR, imaging fusion, contour, tumor motion) should be considered in the SRS/SBRT treatment.