1 Power Quality Mary Santori, P.E. Senior Engineer September 12, 2013.

Slides:



Advertisements
Similar presentations
POWER QUALITY BACKGROUND & ELEC-SAVER TVSS
Advertisements

Outage Reporting Hierarchy Background Data Capture Structure Next Steps.
1 POWER QUALITY -- Bhanu Bhushan -- June, How close is the supply voltage waveform to sinusoidal, and how close are the supply voltage and frequency.
DISPUTES & INVESTIGATIONS ECONOMICS FINANCIAL ADVISORY MANAGEMENT CONSULTING Early Lessons Learned from DOE-EPRI Framework Experience Melissa Chan MA DPU.
 E4 Electrical Installation #1 Power Distribution.
Power Quality: A Closer Look Joe Watson APPA – Engineering & Operations Technical Conference April 18, 2005.
PRESENTED TO THE IEEE LONG ISLAND CONSULTANT’S NETWORK
1 Pacific Gas & Electric Company MTS: Evolution of the Electric Distribution System Manho Yeung, Senior Director, System Planning and Reliability PG&E.
Lecture 26 Distribution Systems Professor Tom Overbye Department of Electrical and Computer Engineering ECE 476 POWER SYSTEM ANALYSIS.
Disconnect Switches There are many purposes for disconnect switches in substations and power lines. They are used to isolate or deenergize equipment for.
ABS Ennin, George Coleman, David Dadson & Anthony Ansah
White Papers – publication: IEEE PES Transactions – note these papers are not overly technical, may not be appropriate placement. T&D World – good audience.
Power Distribution Harmonics Case Study of 285-3F Chiller Plant Michael W. Harmon Principle Engineer Savannah River Nuclear Solutions, LLC Savannah River.
Metropolitan Planning Council Roundtable Discussion November 17, 2011 ComEd J. Tyler Anthony Senior Vice President, Distribution Operations.
Rulemaking PacifiCorp Responses to ALJ Ruling May 26, 2015.
Transient Overvoltages
Section 3 TRANSMISSION & DISTRIBUTION US Bulk Power Transmission System Transmission & Distribution (T&D) Components New T& D Technologies This product.
2. Terms and definitions1 # Terms and Definitions # Voltage Sags and Interruptions.
Electric Infrastructure Workshop Gulf Power Company January 23, 2006.
SDG&E Electric Reliability Reporting CPUC Workshops May 26-27, 2015.
4/22/2017 WHAT IS THERMOGRAPHY?
APPA 2005 E&O Technical Conference Memphis, TN April 19, 2005
POWER SYSTEM PROTECTION. Power system Generators Transformers Transmission lines »Underground cables »Overhead lines Distribution systems.
Lecture 1 – Power Quality INTRODUCTION TO POWER QUALITY Power Quality phenomenon-Terms and definitions-Various Power events in power quality - causes for.
Transformer Taking the ratio of the two equations
Prepared By :.  Introduction  Techniques Used  Case Study  Advantages  Application  Conclusion OUTLINE.
Medium Voltage products Energy reliability & revenue improvement Speaker: Jean-Yves Pocthier - Schneider Electric France Technical solution for improvement.
© ABB PTMV - 1, ABB Overhead Distribution Systems.
2. Terms and definitions1 # Voltage Sags and Interruptions.
IAEC Reliability Webinar Presented by: Regi Goodale and Ethan Hohenadel December 11,
1 Overview of Reliability Requirements XYZ Cooperative Date: abc.
Presentation Identifier (Title or Location), Month 00, 2008 Cost and Benefit Analysis Framework: Update EPRI Smart Grid Advisory Meeting October 14, 2009.
Oncor Electric Delivery Intelligent Grid at Oncor Electric Delivery SWEDE Conference Alan Bern – SCADA / Automation Manager May 1, 2008.
Frankfurt (Germany), 6-9 June 2011 Louise Jakobsen, Danish Energy Association – Denmark – Session 3 – Paper 0811 Louise Jakobsen, Danish Energy Association.
Understanding Power Quality Monitoring
1 Power Quality EKT 451 CHAPTER 8. 2 Introduction Utilities transmit electricity over power lines into home as an alternating current (AC) wave. This.
Utility Engineers, PC.  Generation  Transmission  Distribution.
EECE 887 Distribution System Engineering CHAPTER 1 Power Delivery Systems.
POWER HOUSE.
Introduction  Utilities transmit electricity over power lines into home as an alternating current (AC) wave.  This is how power travels through wiring.
Glades Electric Cooperative Infrastructure Miles of Line 2,213  Overhead Dist.2,180  UndergroundDist. 33  Transmission 87 16,402 meters Average 7.
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Preventing Voltage Sags and Interruptions. # Equipment supplier awareness: # Customers level protection: # Utility level protection: - Sag magnitude and.
Bywater Reliability Update Gary Huntley Entergy New Orleans, Inc. Regional Manager Entergy New Orleans, Inc. July 28, 2010.
What makes substation work?
Uninterruptible Power Supply Improves Reliability at The Australian Synchrotron Sean Murphy – ARW 2013 Melbourne.
SMJE 2103 Power Quality, Reliability and Availability.
Distribution systems basic techniques and radial networks.
Interconnected Generation Preliminary Engineering Work Related to Fees.
Power Quality Issues Power Electronics Group.
AUTOMATIC CIRCUIT RECLOSER
Power System Protective Relaying-Part One
6 Week industrial Training Presentation
CRICOS No J a university for the world real R Aging Equipment Replacement in Power Systems, Using Reliability and Cost Considerations By Dr. Ghavam.
STUDY OF ELEMENTS OF A 220/132/33KV SUBSTATION
Prepared By: Theo Laughner, PE
Power Quality at Solar Distributed Generation Facilities
E4 Electrical Installation
Overhead Distribution Systems
Advanced Fuse-Saving Techniques
35kV Assessment SWEDE 2007 May 10, 2007.
E4 Electrical Installation
Basics of electrical engineering
Protective Relaying Conference
Interconnection of AES With The Grid
Review of Distribution Network Protection
Ahmed Kulab Moh. Abed Foaad Al-Habeel
Customized gis applications for Electric DISTRIBUTION Utilities
Presentation transcript:

1 Power Quality Mary Santori, P.E. Senior Engineer September 12, 2013

2 Topics discussed Causes of Disturbances Normal utility operations that can cause problems with sensitive equipment How Xcel Energy works with customers on power quality issues Reliability Key Indices and Outage Causes Preventive Maintenance

3 Causes of disturbances On-site interference Caused by loads inside a facility affecting the power in such a way as to cause other loads to malfunction Neighboring interference Caused by loads outside a facility affecting the power in such a ways as to cause other loads to malfunction Natural phenomena and accidents Events such as lightning, storms, cars hitting power poles and dig-ins to underground cable Utility operations and problems Normal utility operations or malfunctioning utility equipment

4 Normal utility operations that can cause problems with sensitive equipment Protective devices operating under fault (i.e. breakers, fuses, reclosers) Normal equipment operation (i.e. capacitor bank switching) Single phase events (one phase of a three phase service is out) – Recommend phase protection Xcel Energy RMS voltage guideline: + 5% secondary, + 10% primary and transmission

5 Typical Electric Utility Distribution Layout

6 Typical Electric Utility Capacitor Bank Switching Waveform at Customer

7 Process for power quality issues Gather background information from customer Try and correlate disturbance to utility events Set Recording Meters if Needed Review Findings and Discuss Mitigations

8 Step 1: Review Issue With Customer What happened? Dates and times (important to keep log) Note anything else that happened in facility at the same time Discuss customer’s electrical layout If customer has monitoring, note location of meters (service entrance ideal)

9 Step 2: Correlate Disturbance to Xcel Energy Electrical System If 0 volt condition, review outage logs If voltage sag condition, review outages on transmission system and neighboring taps and feeders If voltage sag or surge condition, review distribution lines device operation (i.e. capacitor banks and voltage regulators)

10 Step 3: Set Recording Meters if Needed Monitor current and voltage at customer’s transformer or service entrance Possibly monitor at neighboring customers

11 Step 4: Review Findings and Discuss Mitigations After reviewing monitoring data, may need to repeat Step 2 Note current and voltage relationship Utility mitigation may include investigating malfunctioning equipment (cap bank, voltage regulator, etc..) Customer mitigation may include installing ride through equipment, soft start on motors, etc..

12 Reliability Indices Reported to the MN PUC (many different formats) SAIFI – System Average Interruption Frequency Index Total Number of Sustained Customer Interruptions Total Number of Customers CAIDI – Customer Average Interruption Duration Index Total Customer Minutes of Sustained Outages Total Number of Sustained Customers Interruptions SAIDI – System Average Interruption Duration Index Total Customer Minutes of Sustained Outages Total Number of Customers MAIFI – Momentary Average Interruption Frequency Index Total Number of Customer Momentary Interruption Events Total Number of Customers

13 Outages Causes (by customer minutes)

14 Preventive Maintenance Efforts Vegetation Management – Continual Condition Assessment/5-Year Maintenance Cycle Infrared Testing – Semiannual Condition Assessment Substation Transformers Circuit Breakers Surge Arrestors Bushings Regulators Animal Control – Ongoing/Condition Based Capacitor Banks – Annual Condition Assessment (Metro Areas) Upgrading with Centralized Controls

15 Customer Reliability Opportunities Customer owned back-up generation UPS Auto or Manual Transfer Phase Loss Protection Transient Voltage Surge Suppression

16 Power Quality Consultants (Note: Xcel Energy does not recommend any one consultant) EPRI, Mark Stephens, Hunt Electric, OlympiaTech, Parsons Electric, ColliSys, Hypertect,

17