RTD and FLOWs at steady and pulsatile flow in systemic circulation

Slides:



Advertisements
Similar presentations
High frequency annular arrays can provide very good resolution in ultrasound bio-microscopy Numerical simulation of their imaging patterns is essential.
Advertisements

Technická univerzita v Liberci Magnetic Field of Massive Conductor at Low Frequency Martin Truhlá ř Faculty of Mechatronics, Informatics and Interdisciplinary.
Doppler echo & colour doppler -fazil bishara.  Blood is not a uniform liquid blood flow is pulsatile and is a very complex phenomenon!!!  Density provides.
Foundations of Medical Ultrasonic Imaging
Svetlana Marmutova Laminar flow simulation around circular cylinder 11 of March 2013, Espoo Faculty of Technology.
Master’s Dissertation Defense Carlos M. Teixeira Supervisors: Prof. José Carlos Lopes Eng. Matthieu Rolland Direct Numerical Simulation of Fixed-Bed Reactors:
1 Small-scale Mobile radio propagation Small-scale Mobile radio propagation l Small scale propagation implies signal quality in a short distance or time.
Self-propelled motion of a fluid droplet under chemical reaction Shunsuke Yabunaka 1, Takao Ohta 1, Natsuhiko Yoshinaga 2 1)Department of physics, Kyoto.
Momentum Heat Mass Transfer
DISTRIBUTION OF RESIDENCE TIMES FOR REACTORS PART I BY PUAN AZDUWIN BINTI KHASRI 10 DECEMBER 2012.
Ground-Water Flow and Solute Transport for the PHAST Simulator Ken Kipp and David Parkhurst.
EE 5340/7340, SMU Electrical Engineering Department, © Carlos E. Davila, Electrical Engineering Dept. Southern Methodist University slides can be.
ECE 501 Introduction to BME
Reactors . ä Reactor: a “container” where a reaction occurs ä Examples: ä Clear well at water treatment plant (chlorine contact) ä Activated sludge tank.
Transport Equations and Flux Laws Basic concepts and ideas 1.A concept model of Diffusion 2.The transient Diffusion Equation 3.Examples of Diffusion Fluxes.
06411 Micro Nucleating Bubble Engine Team Members Steven Nathenson Joseph Pawelski Joaquin Pelaez Andrew Pionessa Brian Thomson Project Sponsors Dr. Crassidis.
LINEAR SECOND ORDER ORDINARY DIFFERENTIAL EQUATIONS
Doppler Radar From Josh Wurman NCAR S-POL DOPPLER RADAR.
CAPILLARY VISCOMETER Motivation
ElectroScience Lab IGARSS 2011 Vancouver Jul 26th, 2011 Chun-Sik Chae and Joel T. Johnson ElectroScience Laboratory Department of Electrical and Computer.
Rudolf Žitný, Ústav procesní a zpracovatelské techniky ČVUT FS 2010 Flowrate Experimental methods E EXM5 Some pictures and texts were copied from.
Instructor: Lichuan Gui
Waves & Wave Properties Determining the Speed of Sound Lab
Wellcome Bienvenue Willkommen Bienvenido Добро пожаловать ようこそ 歡迎.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
LECTURE 9 CHROMATOGRAPHIC SEPARATIONS The “stuff” you do before you analyze a “complex” sample.
Display of Motion & Doppler Ultrasound
(PART B) By; Mrs Hafiza Binti Shukor ERT 208/4 REACTION ENGINEERING
Resident Categorical Course
SIZING PNEUMATIC SYSTEMS. Introduction Pneumatic systems are sized to meet output power requirements. The air distribution system is sized to carry the.
MSc and BSc projects for 2005/2006 Supervisor: Rune W. Time These projects are mainly intended for MSc thesis work, but may be simplified to BSc thesis.
Review: Simultaneous Internal Diffusion & External Diffusion
CE 548 Introduction to Process Analysis and Selection
Display of Motion & Doppler Ultrasound
CHROMATOGRAPHY Chromatography basically involves the separation of mixtures due to differences in the distribution coefficient.
Sarah Gillies Ultrasound Sarah Gillies
© 2014 Carl Lund, all rights reserved A First Course on Kinetics and Reaction Engineering Class 12.
Introduction 1. Similarity 1.1. Mechanism and mathematical description 1.2. Generalized variables 1.3. Qualitative analysis 1.4. Generalized individual.
Slides courtesy of Prof M L Kraft, Chemical & Biomolecular Engr Dept, University of Illinois at Urbana-Champaign. L23-1 Dead Zone Review: Nonideal Flow.
HYDRAULICS of steady and pulsatile flow in systemic circulation Motivation Experimental techniques for measurement pressure and flowrate How to calculate.
R.Žitný, J.Thýn Department of Process Engineering CTU in Prague, Faculty of Mechanical Engineering Acknowledgement: Research.
Wet Stack Fine Particulate Method/CEMS Development Measurement Technology Workshop January 29, 2013.
INTRODUCTION Many heat and mass transfer processes in column apparatuses may be described by the convection – diffusion equation with a volume reaction.
Flow In Circular Pipes Objective ä To measure the pressure drop in the straight section of smooth, rough, and packed pipes as a function of flow rate.
revision Transfer function. Frequency Response
1 Blend Times in Stirred Tanks Reacting Flows - Lecture 9 Instructor: André Bakker © André Bakker (2006)
Ch 4 Fluids in Motion.
FLOW THROUGH GRANULAR BEDS AND PACKED COLUMN
Urban Water Global water aspects
Automatic Equalization for Live Venue Sound Systems Damien Dooley, Final Year ECE Progress To Date, Monday 21 st January 2008.
© 2015 Carl Lund, all rights reserved A First Course on Kinetics and Reaction Engineering Class 33.
Blood Flow Detection > by the Doppler principle > by Electromagnetic principles © D. J. McMahon 2014 rev
Measurements in Fluid Mechanics 058:180 (ME:5180) Time & Location: 2:30P - 3:20P MWF 3315 SC Office Hours: 4:00P – 5:00P MWF 223B-5 HL Instructor: Lichuan.
Ultrasound Learning Objectives: Describe the properties of ultrasound;
Guidelines for OLGA 2000 Slugtracking
Electrodes of heater are perforated - cross flow from lateral channels should improve uniformity of temperatures in central channel. However, R.Žitný,
ERT 208/4 REACTION ENGINEERING: Distribution of Residence Times for Reactors (PART A) By; Mrs Hafiza Binti Shukor ERT 208/4 REACTION ENGINEERING SEM 2.
DYNAMIC BEHAVIOR OF PROCESSES :
In  Out  Generation or Removal  Accumulation
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
Chemical Reaction Engineering II Notes 5 1Dr. A. Okullo.
CFD Simulation & Consulting Services Hi-Tech CFD | Voice: Optimizing Designs of Industrial Pipes, Ducts and.
BME 312 BIOMEDICAL INSTRUMENTATION II LECTURER: ALİ IŞIN
Energy Loss in Valves Function of valve type and valve position
Radio Coverage Prediction in Picocell Indoor Networks
Prepared BY: Helwan University Faculty Of Engineering
Residence Times Distribution for Reactors
HYDRAULICS of steady and pulsatile flow in systemic circulation
Distribution of Residence Times for Reactors
Two-Microelectrode Voltage Clamp of Xenopus Oocytes: Voltage Errors and Compensation for Local Current Flow  W. Baumgartner, L. Islas, F.J. Sigworth 
Presentation transcript:

RTD and FLOWs at steady and pulsatile flow in systemic circulation EXPERIMENTAL METHODS 2010 PROJECT RTD RTD and FLOWs at steady and pulsatile flow in systemic circulation Motivation Dispersion of matter in systemic circulation. Stimulus response method for system identification. Flow distribution and flowrate evaluated from transit time distributions. What is the effect of flow pulsation upon flowrate distribution in a branched system Task prepared within the project FRVS 90/2010

EXPERIMENTAL METHODS 2010 PROJECT RTD Residence times INLET OUTLET Fast particle (short residence time) Residence time  = time spend by a particle inside a continuous system between inlet and outlet. RTD Residence time distribution E() = histogram of residence times  of all particles passing through outlet. Applications of E(): Prediction of chemical reactions yield, transport of farmaceuticals, evaluation of active and stagnant volumes, diagnostics,… There are generally different RTDs for plasma and RTDs of blood particles. Different RTD exists at steady and pulsatile flow.

Stimulus response experiment EXPERIMENTAL METHODS 2010 PROJECT RTD Stimulus response experiment INLET OUTLET All particles passing through inlet at time interval (tI,tI+dt) are marked “red” Unit IMPULSE stimulus E()=impulse response Experiments: “Red particles” – tracers (dyes, radionuclides, salts,…) are quickly injected to inlet. Detectors monitor concentration of tracer at outlet (impulse response). In our case the tracer is KCl solution and reflective particles injected from syringe, detectors are electric conductivity probes.

Response by Convolution EXPERIMENTAL METHODS 2010 PROJECT RTD Response by Convolution Convolution enables to calculate response to an arbitrary stimulus function. It is possible to calculate impulse response E(t) by deconvolution from measured stimulus and response. cin(t), cout(t) concentration of tracer at inlet and outlet of a continuous system cin Convolution of stimulus and RTD function cout E Fourier transform of convolution t [s] Mean time of response = mean time of stimulus + mean residence time Variance of response = variance of stimulus + variance of E

RTD of pipe at convective regime EXPERIMENTAL METHODS 2010 PROJECT RTD RTD of pipe at convective regime Laminar flow and short residence times: diffusion can be neglected and residence times can be calculated from velocity field. The diffusion free regime is characterized by where Q-flow rate, L-pipe length, Dm-diffusion coefficient. Example: C~1000 at aorta, arteries, vena cava. Residence time distribution E() is the response to infinitely short impulse (delta function) cin E() cout Analytical solution exists also for response to a pulse of a finite width (violet line). Time of the first appearance is not affected, only mean response time is increased.  (s) First appearance time =4s

Laboratory model of circulation EXPERIMENTAL METHODS 2010 PROJECT RTD Laboratory model of circulation Simulated part - pressure or conductivity transducers alternatively Cresto Platinum wires

NODES of simulation model EXPERIMENTAL METHODS 2010 PROJECT RTD NODES of simulation model Y [m] 19 Data file defines the coordinates x,y,z of all 29 nodes 18 16 15 28 17 27 14 22 20 29 7 9 12 25 24 6 21 26 8 5 10 11 13 4 3 Conductivity probes. Q-flowrate, C-response (defined in form of table) 23 2 1 -0.4 -0.3 -0.2 -0.1 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 X [m]

ELEMENTS of simulation model EXPERIMENTAL METHODS 2010 PROJECT RTD ELEMENTS of simulation model V5(14,16,15,27,d3,d4,d4) V6(17,18,19,28,d3,d4,d4) P6(7,17,d3) V7(20,22,21,29,d3,d4,d4) P5(9,14,d3) P7(6,20,d3) V3(8,9,10,25,d2,d3,d3) 25 V2(5,6,7,24,d2,d3,d3) P4(8,11,d3) P3(4,8,d2) V4(11,12,13,26,d3,d4,d4) P2(3,5,d2) Nodal indices V1(2,3,4,23,d1,d2,d2) Data files define connectivity of PIPES (2-node elements) DIVISION (3-node elements) P1(1,2,d1)

RESPONSEs generated by PIPES EXPERIMENTAL METHODS 2010 PROJECT RTD RESPONSEs generated by PIPES x2,y2,z2 Q2 ,c2(t) d x1,y1,z1 ,Q1, c1(t) Convolution realized by FFT, and by inverse transformation.

RESPONSEs generated by WYES EXPERIMENTAL METHODS 2010 PROJECT RTD RESPONSEs generated by WYES Given c1(t) x2,y2,z2 Q2,c2(t) x3,y3,z3 Q3,c3(t) Intermediate response d1 x4,y4,z4 x1,y1,z1, Q1,c1(t) final response It is alternatively possible to characterize the whole wye as a perfectly mixed vessel. In this case the both responses c3 and c2 will be identical PROBLEMS: 1. Derive impulse response of perfectly mixed vessel Emixed(t) 2. How to modify the responses in the case that detectors record not the tracer concentration but the flowrate of tracer (e.g. radiotracer – counter records rate of decays in the whole outlet).

Simulation in MATLAB MATLAB M-files available at http: EXPERIMENTAL METHODS 2010 PROJECT RTD Simulation in MATLAB MATLAB M-files available at http: Simulation proceeds according to M-file RTD.m in steps Reading input files xyzq,seq,cp,cv (txt) defining nodes, flowrate and elements Definition of time scale, time steps, and stimulus function at entry node 1. Evaluation of responses sequentially in all elements (sequence is defined in vector seq). Responses are evaluated by FFT in functions function cout=convpipe(t,n,dt,cin,d,l,q) tmean=pi*d^2*l/(4*q); for i=1:n if t(i)<tmean/2 e(i)=0; else e(i)=tmean^2/(2*t(i)^3); end fcin=fft(cin); fe=fft(e); fcout=fcin.*fe; cout=ifft(fcout)*dt;

Simulation in MATLAB MATLAB M-files available at http: EXPERIMENTAL METHODS 2010 PROJECT RTD Simulation in MATLAB MATLAB M-files available at http: Input data files: xyzq.txt x y z q (nodal coordinates and flowrates) seq.txt e1 e2 … (sequence of evaluated elements, +pipes, -wyes) cp.txt i j d (pipe -indices of nodes and diameter) cv.txt i j k l d1 d2 d3 (wye - indices of nodes and diameters) TASK: 1. Modify input files according to parameters of your experiment 2. Compare calculated and measured concentration responses 3. Evaluate flowrates in branches from the shortest/mean transit times

Experiments: UVP velocities EXPERIMENTAL METHODS 2010 PROJECT RTD Experiments: UVP velocities Ultrasound Doppler effect for measurement velocity profiles Piezotransducer is transmitter as well as receiver of US pressure waves operating at frequency 4 or 8 MHz. Short pulse of US waves is transmitted (repetition frequency 244Hz and more) and crystal starts listening received frequency reflected from particles in fluid. Time delay of sampling (flight time) is directly proportional to the distance between transducer and the reflecting particle moving with the same velocity as liquid. Received frequency differs from the transmitted frequency by Doppler shift Δf, that is proportional to the component of particle velocity in the direction of transducer axis. http://biomechanika.cz PROBLEMS: What is spatial resolution of velocity, knowing speed of sound in water (1400 m/s) and sampling frequency 8 MHz ? Calculate flowrate in a circular pipe from recorded velocity profile (given angle )

Experiments: flowrates EXPERIMENTAL METHODS 2010 PROJECT RTD Experiments: flowrates Flowrate can be identified also from the stimulus response experiments Mean residence time Shortest residence time (time of the first appearance) Cross-correlation of stimulus and response functions http://biomechanika.cz

LABORATORY REPORT EXPERIMENTAL METHODS 2010 PROJECT RTD Front page: Title, authors, date Content, list of symbols Introduction, aims of project, references Description of experimental setup Experiments with injection of tracer at a steady state regime. Record responses and pressures. Evaluate flowrate from recorded pressure drop. Check Re and flow regime. Evaluate flowrate from recorded responses and transit times. Evaluate flowrate from velocity profiles recorded by UVP monitor. Simulation (steady state). Modify input files and M-files according to measured flowrates and concentration profile at inlet. Evaluate theoretical responses at nodes with conductivity detectors. Adjust flowrate pulsation and repeat tracer experiments. Evaluate flowrate distribution at pulsatile flow and compare relative flowrates with steady state case. Conclusion (identify interesting results and problems encountered)