Investigation of Automated Sampling Techniques to Measure Total Mercury in Stream-Water During Storm-Events Department of Environmental Sciences, University.

Slides:



Advertisements
Similar presentations
Assessing Risk of Heavy Metals Input in Food Chain. 1. Introduction Among the many elements that occur in the natural environment about 60% of them are.
Advertisements

Year of Clean Water: National Water Monitoring Day Water Testing Kits.
Volunteer Water Monitoring Support through the UWSP Center for Watershed Science and Education Nancy Turyk Citizen-Based Monitoring Conference August 2004.
Overview of Environmental Contamination in Lao PDR Dr. Kesiny Phomkeona Department of Chemistry Faculty of Science National University of Laos.
The students in the Freshman Academy & the Green School Initiative are proud to present the following on- line tutorial about biodiesel production at HPHS.
Office of Water PittCon 2001 Status of EPA Method 1631 for the Determination of Low-Level Mercury Maria Gomez-Taylor Analytical Methods Staff U.S.
Fecal Colform Bacteria Contamination during Rain Events in Sayler’s Creek, Virginia Blake N. Robertson Senior Honors Research Under the Supervision of.
Module 6 Effluent Monitoring and Receiving Water Monitoring.
Water Quality Assessment of Osage Creek & West Fork, White and Kings Rivers 2008 & ½ 2009 Marc Nelson PhD, PE Nelson Engineering.
Collecting a Stormwater Sample Annual CMTA Marine Trades Exposition October 5, 2010.
2009 Water Quality Monitoring Report – Fish Creek Vaughn Hauser, B.Sc. Naomi Parker, B.Sc., BIT, CEPIT.
Max Jacobson Daniel Sigman Katye Altieri Sarah Fawcett.
Mercury Collection and Analysis in Ambient and Effluent Waters using EPA Method 1631 Overview of Sampling and Analysis William Telliard U.S. EPA Office.
Mercury Monitoring The FDEP Laboratory Perspective Timothy W. Fitzpatrick (850)
Suspended particle property variation in Gaoping Submarine Canyon Ray T. Hsu and James T. Liu Institute of Marine Geology and Chemistry, National Sun Yat-sen.
QA/QC Considerations for Sampling and Analysis Associated with EPA Method 1631 Chuck Wibby Wibby Environmental Seminar on Low Level Mercury Data and Analyses.
Acid distillation and solvent extraction methods 1,2,3,4 are widely used to determine monomethyl mercury (MMHg) content in sediments. During initial phases.
Importance of Quality Assurance Documentation and Coordination with Your Certified Laboratory Amy Yersavich and Susan Netzly-Watkins.
Riparian zone spiders as mercury sentinels Dr. Christopher Pennuto 1,2, Marley Smith 1, and Dr. Alexander Nazarenko 3 1 Biology Department, 2 Center for.
MOUNTAINS AT RISK. Alpine areas: early warning indicators Organisms on edge of environmental tolerance Same processes as downstream forested and grassland.
DRAFT Field Sampling Guidance To be used this field season by DEC and consultants Initial focus on soil, groundwater, and vapor intrusion Future versions.
QA/QC FOR ENVIRONMENTAL MEASUREMENT Unit 4: Module 13, Lecture 2.
Introduction to Air Pollution John Atkinson and Dr. Mark Rood Environmental Engineering and Science Program Department of Civil and Environmental Engineering.
Water Quality Monitoring and Parameter Load Estimations in Lake Conway Point Remove Watershed and L’Anguille River Watershed Presented by: Dan DeVun, Equilibrium.
Water Quality Monitoring and Parameter Load Estimations in Lake Conway Point Remove Watershed, L’Anguille River Watershed, and Bayou Bartholomew Presented.
Introduction Atmospheric mercury (Hg) deposition is a growing global concern, even in pristine regions far from point sources. Once deposited, it can be.
Monitoring Well Sampling. SAP (Sampling Analysis Plan) SAP (Sampling Analysis Plan) Frequency Frequency Purging Purging Pumps and Bailers Pumps and Bailers.
© 2010 Cerilliant Corporation | 811 Paloma Drive | Round Rock, TX Uncertainty in the micro-ROI measurement was estimated following the guidelines.
Characterizing Storm Water Runoff from Natural Gas Well Sites in North-Central Texas Paul F. Hudak and David J. Wachal Department of Geography University.
HydrometJanuary AMS Short Course on Instrumentation1 HydrometeorologicalMeasurements Melanie A. Wetzel Desert Research Institute University of.
PROPAGATION OF ERROR.  We tend to use these words interchangeably, but in science they are different Accuracy vs. Precision.
Implementation of the USEPA Methods Update Rule to 40 CFR : Field Filtration & Preservation Gerard Marzec, James Broderick and Karen Moore, PhD NYC Department.
West Fork of the White River Stream Restoration Monitoring Dan DeVun Ecological Conservation Organization (501)
Collection and Preservation of Water and Wastewater Samples
Dr. Matt Helmers Assistant Professor and Extension Agricultural Engineer Dept. of Agricultural and Biosystems Engineering Iowa State University How is.
1. Introduction The Big Darby Creek is categorized as a national scenic river with an array of biological species. Since this is one of the last pristine.
Titration and Buffers Chemistry Department Minneapolis Community & Technical College Intro to Chemistry Chem1020 Lab 1.
U.S. Department of the Interior U.S. Geological Survey Water-Quality Monitoring: Data Collection and Analysis Strategies for Designing Program.
Abandoned Mine Lands Assessment of the North Yuba Watershed.
Focus on the Headwaters The Shenandoah Watershed Study / The Virginia Trout Stream Sensitivity Study Rick Webb Department of Environmental Sciences University.
Summary of Water Quality Data Analysis from the Storm Water Management Ponds of Central Park Fredericksburg, VA Dr. Michael L. Bass Miña Recta, Diana Gutierrez.
Timeline Impaired for turbidity on Minnesota’s list of impaired waters (2004) MPCA must complete a study to determine the total maximum daily load (TMDL)
Geologic controls on the chemical stream water response to atmospheric pollution (acid and Hg deposition) in Shenandoah National Park Ami Riscassi Drew.
Results and Discussion The above graph depicts FC colony plate averages for each sample site. Samples are ordered from upstream to downstream as indicated.
Findings Is the City of Oberlin a source or a sink for pollutants? Water quality in Plum Creek as a function of urban land cover Jonathan Cummings, Tami.
Our Case Study. Rationale for study The TMDL model assumes that there is no decrease in seepage during low flow conditions, basing its calculations on.
William Telliard U.S. EPA Office of Science and Technology
Introduction The Equipment The Terms The Process Calculations
Methylmercury Production in Groundwater Watershed Hg Research Program at SERC Deposition Transport Watershed retention Methylation MDN site MD00 Stream.
Water quality sensors provide insight into the suspended solids dynamics during high flow events in the Lamprey River, NH Nicholas K. Shonka and William.
STORMWATER SAMPLING OF OIL PRODUCTS USING SEMIPERMEABLE MEMBRANE DEVICES (SPMDs) Per-Anders Bergqvist, *Lina Ulčinienė, *Viktoras Račys and *Audronė Žaliauskienė.
Titration Analysis.
Clean Sampling of Mercury
Think about answering the questions: Who? What? Where? When? Why? How? Before your volunteers begin collecting data.
 Water Quality Variability in a Bioswell and Concrete Drainage Pipe, Southwest Lincoln, Nebraska Jessica Shortino, B.S. University of Nebraska-Lincoln.
Elizabeth Keily, Daniel Boehling, Arif M. Sikder, S
Determination of TKN by Subtraction using ASTM D and ASTM D
Water quality characterization of the Pebble prospect area in Southwestern Alaska Comparison of PLP and independent science team scope, methods, and results.
Status of EPA Method 1631 for the Determination of Low-Level Mercury
Overview of EPA Method 1631, Revision E By Roy W
Conclusions & Future Work
Heavy metals concentration of Fecal Solids of Recirculating Aquaculture System for Renewal Feed Resource for Sea Cucumber Anisuzzaman Md, Feng Jin, Ga-Hyun.
GROUNDWATER QUALITY ASSESSMENT OF THE PINEY POINT AQUIFER
Olga Ogburn Background
Hydrogeologic Investigations of the Silver Lake Wetland
Environmental sampling and monitoring
Unit 1 Clicker Review.
Setback area relative to drainage area Runoff volume, mean of 4 events
Acid-Base Titration. Acid-Base Titration. Acid-Base Titration.
Victoria Schoenwald Undergraduate Program
Presentation transcript:

Investigation of Automated Sampling Techniques to Measure Total Mercury in Stream-Water During Storm-Events Department of Environmental Sciences, University of Virginia Introduction High-flow events (storms, snowmelt) are a dominant transport mechanism for total mercury (Hg T ) from the terrestrial to the aqueous environment. High-gradient headwater catchments are a primary source of downstream contamination because they store large pools of Hg in soils and sediments. Consistent, high-frequency event-sampling of headwater streams is rare, however, because of the unpredictability of high flows, remoteness of sites, and the difficulties associated with the ultra-clean sampling procedures (Shanley et al., 2008). The use of automated sampling techniques with an ISCO ® sampler has been demonstrated in several studies for trace metals and two studies for Hg (Nelson et al., 2007; Lawson and Mason, 2001). The errors associated with using automated techniques for Hg T sampling, however, has not been systematically evaluated in the literature. This research focuses on quantifying the relative errors associated with using an automated sampling system for streamwater Hg T analysis and establish quality assurance guidelines for future sampling campaigns. Objectives Methods Conclusions Acknowledgements Ami L. Riscassi*, Todd M. Scanlon Results Materials What’s next? FP/Teflon ® lined caps FP/Teflon ® tubing (30 ft.) FP /Teflon ® strainer (made from tubing) FP /Kynar ® connectors/fittings C-flex pump tubing for peristaltic pump ISCO ® 2900 automated sampler glass bottles for ISCO samples FP/Teflon ® bottles for grab samples Literature Cited Amber ‘Dirty Hands’ Converse (UVA master’s student) provided analytical assistance and Kelly Hokanson (UVA undergraduate) provided field assistance. Susie Maben and Frank Deviney, of the Shenandoah Watershed Study (SWAS), provided historical streamwater chemistry data. Funding was provided through the NSF Career Grant, the DOE Graduate Assistantship in Areas of National Need (GAANN) fellowship, and the EPA Science to Achieve Results (STAR) fellowship. Figure 1. Grab sampling streamwater for Hg analysis (USGS photo taken from Shanley et al., 2002). Figure 2. ISCO automated sampler (right) at Paine River in Shenandoah National Park, Virginia. Figure 3. Teflon sample line and strainer. 1) Quantify the cumulative errors associated with automated sampling for Hg T analysis. Potential errors are determined for a) sequential sampling with the same strainer, sample & pump tubing b) empty sample bottles left open c) samples left open in an ISCO 2) Determine when it is appropriate to use automated sampling techniques * Corresponding author: Ami Riscassi Lawson, N. M., and R. P. Mason (2001), Concentration of mercury, methylmercury, cadmium, lead, arsenic,and selenium in the rain and stream water of two contrasting watersheds in Western Maryland, Water Research, 35(17), Nelson, S.J. et al. (2007), Mass balances of mercury and nitrogen in burned and unburned forested watersheds at Acadia National Park, Maine, USA, Environmental Monitoring and Assessment, 126, Shanley, J. B., et al. (2008), Comparison of total mercury and methylmercury cycling at five sites using the small catchment approach, Environmental Pollution, 154, All experiments were conducted with water from a local stream (Staunton River) during base flow conditions. Hg T concentration of streamwater used in the experiments was 0.29 ppt. Analysis of major cations/anions has not yet been completed, but mean concentrations calculated from 10 yrs of weekly baseflow samples indicate basic parameters are as follows: 6.7 pH, 18 μS conductivity, 86 μeq/L alkalinity, 44 μeq/L SO 4, 23 μeq/L Cl, and DOC 0.7 mg/L. Equipment test (water 5° C) : Empty bottle test: All samples were preserved within one hour of collection with 100% BrCl solution (5 ml/L). Samples were analyzed within a week of preservation for unfiltered Hg T on a Tekran 2600 Cold Vapor Atomic Fluorescence Spectrophotometer (CVAFS) at the University of Virginia Lab. The relative percent difference (RPD) for field duplicates was <15%. Equipment test Hg T concentrations of streamwater sampled with an ISCO were elevated compared to ‘grab’ samples. Hg T contamination ranged from 0.00 to 0.84 ppt. The relative percent difference (RPD) between grab and ISCO samples ranged from 0.2 to 94%. The largest RPD’s are associated with baseflow samples immediately following a highly concentrated sample (25 or 50 ppt), a situation which is atypical in the natural environment. Empty bottle test Mean Hg T contamination of uncapped empty bottles ranged from 0.07 to 0.25 ppt for the 3 and 7 day periods tested. Greater contamination was observed in open bottles with other samples (0.29 vs 0.10 ppt). Uncapped sample test All uncapped samples lost Hg T ranging from 0.1 to 4.8 ppt. The RPD of [Hg T ] between ‘grab’ and ISCO samples ranged from 10 to 30%. Air temperature range: (25-58°F) (1) Repeat the bottle experiments in a heated environment (‘summertime’). (2) Concurrent manual stream sampling (middle of water column) and ISCO automated stream sampling during storm event. Figure 4. Staunton River, Va. Figure 5. Set-up of ISCO line test. Figure 6. Set-up of ISCO bottle test for contamination/evasion. Figure 7. Tekran 2600 and Dr. Babi. Uncapped sample test: ISCO programmed to rinse line 3X before sample collection ISCO samples streamwater (white vat) Manual sample poured from vat directly to bottle (‘grab’ sample) ISCO samples Hg-spiked streamwater (red vat) Manual sample poured from vat directly to bottle (‘grab’ sample) Rinse off outside of strainer with 50 ml streamwater (black vat) ISCO samples streamwater (white vat)... Repeat for [Hg] spike: 0.5, 5.0, 25.0, & 50.0 ppt 2 sets of uncapped empty bottles in ISCO without samples 2 sets of uncapped empty bottles in ISCO with samples ( ppt) First bottle sets collected after 3 days and second sets after 7-days, and all bottles filled with streamwater of known [Hg T ] 2 sets of ISCO bottles filled with streamwater, and streamwater spiked with 0.5, 5.0, 25.0, and 50.0 ppt Hg First bottle set collected after 3-days and second at 7-days. Figure 8. Hg T concentration of ‘grab’ and ISCO samples. The X-axis indicates the spiked Hg T concentration in ppt. Absolute difference and (RPD) are labeled above the respective data. Figure 9. Hg T concentrations of streamwater poured into a unopened bottle, and poured into empty bottles that had been left open in an ISCO. Absolute difference (ppt) is labeled above the respective data. Figure 10. Hg T concentrations of samples left uncapped for 3 and 7-days in an ISCO. The X-axis indicates spiked [Hg T ]in ppt. Maximum absolute difference and RPD are labeled above the respective data. The cumulative errors of using an ISCO automated streamwater sampler resulted in a RPD in Hg T concentration ranging from: 8-10% for 50 ppt, 11-15% for 25 ppt, 2-20% for 5ppt, % for 0.8 ppt, and 5-120% for 0.3 ppt. ISCO automatic samplers can be used to measure streamwater for Hg T when concentrations are above 5 ppt (2 20%). The EPA Method 1631 specifies that the RPD between field duplicates should be less than 20%. All materials used in automated sampling are fluoropolymer (FP) (except pump tubing) and are cleaned by soaking in a heated (75 °C) 4N HCl acid vat for 12 hrs., rinsed 3X with DI, dried under a clean bench, and double bagged until use. Sample bottles are cleaned according to EPA protocol.