Keith Aaronson, Mark Slaughter, Edwin McGee, William Cotts, Michael Acker, Mariell Jessup, Igor Gregoric, Pranav Loyalka, Valluvan Jeevanandam, Allen Anderson,

Slides:



Advertisements
Similar presentations
Assisted Circulation MEDICAL MEDICAL  Drugs  EECP MECHANICAL  IABP ( Introaortic balloon pump)  VAD (Ventricular assist device)
Advertisements

Can Comparative Effectiveness Study Tell Us What Is The Best Therapy For Class IV Heart Failure? Beta blockers or LVADs?
Hemolysis in Patients Supported with Durable, Long-Term Left Ventricular Assist Device Therapy Jason N. Katz, MD,MHS; Brian C. Jensen, MD; Patricia P.
Study by: Granger et al. NEJM, September 2011,Vol No. 11 Presented by: Amelia Crawford PA-S2 Apixaban versus Warfarin in Patients with Atrial Fibrillation.
Estimating Benefit in Ambulatory Heart Failure Patients MedaMACS Progress Report 2014 Garrick C. Stewart, MD Brigham and Women’s Hospital.
Welcome Ask The Experts March 24-27, 2007 New Orleans, LA.
A Canadian View on Effective Use of VADS Value Based Care and the Role of INTERMACS in our Evolving Health Care Environment A Canadian View on Effective.
ACC 2015 Michael J Reardon, MD, FACC On Behalf of the CoreValve US Investigators A Randomized Comparison of Self-expanding Transcatheter and Surgical Aortic.
Equipoise Does Not Exist for REVIVE IT Andrew Boyle, MD Heart and Vascular Center Director, Florida Chairman of Cardiology Medical Director of Heart Failure,
Preliminary results from the C-Pulse OPTIONS HF European Multicenter Post-Market Study Holger Hotz, CardioCentrum Berlin, Berlin, Germany; Antonia Schulz,
Between May 2013 and June 2014, we implanted the C-Pulse device in 7 male and 1 female patients with a mean age ± SD of 61.1 ± 9.4 years. Four had ischemic.
Randomized Evaluation of Long- term anticoagulant therapY Dabigatran Compared to Warfarin in 18,113 Patients with Atrial Fibrillation at Risk of Stroke.
Advances In LVAD Patient Management
What have we learned? What is next? Panel B: Functional Capacity, Quality of Life and Outcomes H.Functional Capacity I.Neurocognitive Assessment J.Quality.
Coordinator Training Session: March 11, 2012 Major Changes in Data EntryMyers 1 What is the same? What is reduced/removed? What is added/expanded? INTERMACS.
The Long Term Multi-Center Extension of Dabigatran Treatment in Patients with Atrial Fibrillation (RELY-ABLE) study To reviewers and moderators: These.
A Validated Practical Risk Score to Predict the Need for RVAD after Continuous-flow LVAD SK Singh MD MSc, DK Pujara MBBS, J Anand MD, WE Cohn MD, OH.
Biventricular Failure – Total Artificial Heart Francisco A. Arabía, MD Director, CHSI Center for Surgical Device Management Cedars-Sinai Heart Institute.
Predicting Patients at Risk for Poor Global Outcomes after DT- MCS Therapy Suzanne V. Arnold, MD, MHA Saint Luke’s Mid America Heart Institute/UMKC May.
Periportal Fibrosis Without Cirrhosis Does Not Affect Outcomes Following Continuous Flow Ventricular Assist Device Implantation Jonathon E. Sargent, BS,
Contemporary Outcomes With the HeartMate II® LVAS
Blood Pressure Lability During Cardiac Surgery Is Associated With Adverse Outcomes Solomon Aronson, Edwin G. Avery, Cornelius Dyke, Joseph Varon, Jerrold.
Predicting Major Outcomes after MCSD Implant 1 Risk Factors for Death, Transplant, and Recovery James Kirklin, MD David Naftel, PhD.
Risk Assessment and Comparative Effectiveness of Left Ventricular Assist Device and Medical Management in Ambulatory Heart Failure Patients Assessment.
Author Disclosures Differences in Implantation-Related Adverse Events Between Men and Women Receiving ICD Therapy for Primary Prevention Differences in.
HeartWare HVAD: Risk Factors for Adverse Outcomes Mark S. Slaughter, MD Professor and Chair Department Cardiovascular and Thoracic Surgery University of.
Survival following VAD complications: implications for transplant priority. Todd Dardas, MD, MS May 16, 2015.
The VentrAssist U.S. Pivotal Bridge to Cardiac Transplantation Trial A Boyle, N Moazami, R John, G Ewald, A Anyanwu, S Pinney, S Desai, N Burton, J Teuteberg,
Avoiding Cardiovascular Events through COMbination Therapy in Patients LIving with Systolic Hypertension The First Outcomes Trial of Initial Therapy With.
Development of a novel predictive model for mortality post continuous flow LVAD implant using Bayesian Networks (BN) N. A. Loghmanpour 1, M. K. Kanwar.
A Comparison of Albumin and Saline for Fluid Resuscitation in the Intensive Care Unit The SAFE Study Investigators N Engl J Med 2004: 350:
Risk Factors for Adverse Outcome after HeartMate II Jennifer Cowger, MD, MS St. Vincent Heart Center of Indiana Advanced Heart Failure, Transplant, & Mechanical.
Clinical Review AbioCor® Implantable Replacement Heart H Julie Swain M.D. Cardiovascular Surgeon Ileana Piña M.D. Heart Failure Cardiologist DRAFT.
Management of Gastrointestinal Bleeding in 2015 WITH SPECIAL FOCUS ON GI BLEEDING IN PATIENTS WITH LEFT VENTRICULAR ASSIST DEVICES (LVAD)
MCSRN Mechanical Circulatory Support Research Network
Mechanical Circulatory Support in Special Populations Renzo Y. Loyaga-Rendon MD.,PhD.. Assistant Professor Advanced Heart Failure Section University of.
Copenhagen University Hospital Rigshospitalet, Denmark
Analysis of Pump Thrombosis in the Intermacs Database Michael Acker William Measey Professor of Surgery Chief of Division of Cardiovascular Surgery Director.
Natural History of Heart Failure
Disclosure Statement of Financial Interest
PREVENtion of Pump Thrombosis Through Clinical Management (PREVENT) John M. Stulak, MD Mayo Clinic.
Michael S Kiernan, MD, SM Assistant Professor, Tufts University Medical Director Ventricular Assist Device Program, Tufts Medical Center.
Date of download: 6/3/2016 Copyright © The American College of Cardiology. All rights reserved. From: Risk Assessment and Comparative Effectiveness of.
INTERMACS Annual Meeting
Date of download: 7/9/2016 Copyright © The American College of Cardiology. All rights reserved. From: Results of the Destination Therapy Post-Food and.
These slides highlight a presentation at the Late Breaking Trial Session of the American College of Cardiology 52nd Annual Scientific Sessions in Chicago,
Update on the Watchman Device CRT 2010 Washington, DC
Total Artificial Heart (TAH): Survival Outcomes, Risk Factors,
James K. Kirklin, MD, Francis D. Pagani, MD, PhD, Robert L
INTERMACS 10th Annual Meeting March , 2016 Quality of Life
Jennifer A. Cowger, MD, Matthew A
Assist Devices for the Treatment of Cardiogenic Shock
The ADEMEX Trial Adequacy of PD in Mexico Reference
Intermacs and the Scientific Registry of Transplant Recipients (SRTR)
Αντιμετώπιση καρδιακής ανεπάρκειας προχωρημένου και τελικού σταδίου
Fifth INTERMACS annual report: Risk factor analysis from more than 6,000 mechanical circulatory support patients  James K. Kirklin, MD, David C. Naftel,
Late Follow-Up from the PARTNER Aortic Valve-in-Valve Registry
Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 (MOMENTUM 3) – Long Term Outcomes.
Cardiovacular Research Technologies
The following slides highlight a presentation at the Late-Breaking Clinical Trials session of the American Heart Association Scientific Sessions, November.
Long-term mechanical circulatory support (destination therapy): On track to compete with heart transplantation?  James K. Kirklin, MD, David C. Naftel,
Five-Year Outcomes after Randomization to Transcatheter or Surgical Aortic Valve Replacement: Final Results of The PARTNER 1 Trial Michael J. Mack, MD.
Impact of Marital Status on LVAD Mortality: A Single Center Experience Linda Njoroge MD, Mohamed Khayata MD, Kevin Charnas, Paul Bate, Madison Edge, James.
Welcome Ask The Experts March 24-27, 2007 New Orleans, LA.
Mandeep R. Mehra, MD, Nir Uriel, MD, Joseph C. Cleveland, Jr
Adverse events in contemporary continuous-flow left ventricular assist devices: A multi- institutional comparison shows significant differences  John M.
Durability of left ventricular assist devices: Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) 2006 to 2011  William L.
Linking Intermacs to the World:
Transcatheter versus medical treatment of symptomatic severe tricuspid regurgitation: a propensity score matched analysis Maurizio Taramasso MD, PhD from.
Presentation transcript:

Keith Aaronson, Mark Slaughter, Edwin McGee, William Cotts, Michael Acker, Mariell Jessup, Igor Gregoric, Pranav Loyalka, Valluvan Jeevanandam, Allen Anderson, Robert Kormos, Jeffrey Teuteberg, Francis Pagani, Steven Boyce, David Hathaway, Leslie Miller for the HeartWare ADVANCE Investigators Evaluation of the HeartWare HVAD Left Ventricular Assist System for the Treatment of Advanced Heart Failure: Results of the ADVANCE Bridge to Transplant Trial American Heart Association Scientific Sessions 2010

Presenter Disclosure Information Keith Aaronson, MD, MS FINANCIAL DISCLOSURE –Research Support: HeartWare*, Thoratec*, Terumo –Clinical Steering Committee: HeartWare –Personal remuneration: none –* My activities with HeartWare and Thoratec have been reviewed and approved by the University of Michigan Medical School Conflict of Interest Board and a management plan is in place. UNLABELED/UNAPPROVED USES DISCLOSURE –I will discuss investigational use of the HeartWare HVAD

HeartWare Ventricular Assist System HVAD miniaturized implantable blood pump –Pericardial placement – no pump pocket –Provides up to 10 L/min of flow –Centrifugal design, continuous flow –Hybrid magnetic / hydrodynamic impeller suspension –Optimizes flow, pump surface washing, and hemocompatibility Thin (4.2 mm), flexible driveline with fatigue resistant cables

Multi-site (30), prospective trial to evaluate the HeartWare HVAD as a bridge-to-transplant in the US Enrollment period was August 2008 to February 2010 All patients were followed for ≥ 180 days following implant or until earlier cardiac transplantation, device explant for recovery or death Treatment group was compared to a contemporaneous control group consisting of patients enrolled in the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) who received a commercially-available, durable, left ventricular assist device as a BTT ADVANCE Trial Design

Adult patients who received a primary LVAD as a BTT during the enrollment period Listed for transplant at time of implant BSA ≥ 1.2m 2 Serum creatinine ≤ 5 without dialysis Not on ventilator First VAD IABP only allowable preop circulatory support Treatment Group (n=137) Inclusion Criteria: age >18 years, BSA >1.2m 2, NYHA Class IV, listed UNOS Status 1A or 1B Standard LVAD/transplant exclusion criteria IABP only allowable preop circulatory support INTERMACS Control (n=499) * 2 excluded for liver enzymes >3x normal, 1 excluded for participation in another trial Derivation of Treatment &Control Populations n = 499 Enrolled (n = 3187) Patients excluded who did not meet criteria for primary analysis cohort n = 137 Enrolled (n = 157) - Screen failures (17) = Intent to Treat (140) - 3 patients* = Per Protocol Pop.

Primary Outcome –Success*, defined as survival on the originally implanted device, transplant or explant for ventricular recovery (must survive 60 days post- explant) at 180 days –Analysis adjusted by propensity score Predictors: age, gender, BUN, creatinine, BSA, right atrial pressure, prior sternotomy, INTERMACS profile Secondary Outcomes –Comparison of survival between treatment and control groups –Functional and QoL outcomes and AEs in the treatment group Functional status changes, measured by 6-min walk test QoL changes, measured by KCCQ and EuroQoL EQ-5D Incidence of SAEs * Per Protocol cohort ADVANCE Trial: Analyses

Control (n=499) P value 52.2 ± (24%) ± ± ± ± Treatment (n=140) Age (years)53.3 ± 10.3 Female Gender, n (%)39 (28%) BSA (m 2 )2.06 ± 0.28 BUN (mg/deciliter)25.3±13.5 Right atrial pressure (mmHg)10.8 ± 3.3 Serum creatinine (mg/dL)1.3 ± 0.4 Etiology - % Ischemic41% LVEF (%)17.8 ± 7.1 CI (L/min/m 2 )2 ± 0.5 PCWP (mmHg)23 ± 9 Mean arterial blood pressure (mmHg)77 ± 13 Intravenous inotropic agents, n (%) Any inotrope Two or more inotropes 115 (82%) 16 (11%) IABP35 (25%) ADVANCE Trial: Baseline Characteristics

Treatment *ControlP value INTERMACS 1 INTERMACS 2 INTERMACS 3 INTERMACS (5.0%) 39(27.9%) 62(44.3%) 32(22.9%) 39(7.8%) 259(51.9%) 103(20.6%) 98(19.7%) <.002 Quartile 1 Quartile 2 Quartile 3 Quartile 4 12(8.8%) 28(20.4%) 51(37.2%) 46(33.6%) 145(29.2%) 131(26.4%) 107(21.5%) 114(22.9%) <.0001 Propensity Score INTERMACS Patient Profile *Safety Population (N=140) for INTERMACS Patient Profile; Per Protocol Population (N=137) for Propensity Score INTERMACS & Propensity Score

Control Group Success:90.1% Treatment Group Success:92.0% Difference:-1.9% 95% Upper Confidence Limit (UCL) on difference0.9% Principal Analysis: Noninferiority The UCL, 0.9%, is less than the prespecified 15% noninferiority margin. Treatment group success is noninferior to control (p<0.001) Secondary Analysis: Superiority Unadjusted: Difference = -1.9%, p = 0.62 Propensity score adjusted:Difference = -3.1%, p = 0.20 All results are from the Per Protocol cohort. For noninferiority analysis, p value one-sided; for superiority analysis, p values two-sided ADVANCE Trial Primary Outcome: Success

Days Post Implant Proportion of Patients 62.8% Alive 29.2% Transplant 3.6% Death 4.4% Device Exchange 92.0% Transplant or Alive ADVANCE Trial Treatment Group Outcomes (Per Protocol Population) Patients at Risk NOTE: Original device in place for all outcomes

Days Post Implant % Survival Event: Death (censored at transplant or recovery) ITT Population Patients at Risk Treatment Control ADVANCE Trial Secondary Outcome: Survival Days Post Implant TreatmentControl %96.6% %93.6% %90.2% %85.7% p =.39 HVAD Control

KCCQ n = 79 Better QoL / Best Health Status Worst QoL/ Health Status 6 Min Walk Clinical Summary │ Overall Summary 79 All paired differences p<0.001 EQ-5D VAS Δ = +77% Δ = +106% Δ = +91% Δ = +106% Quality of Life and Functional Capacity

Pagani, et al. Event Rate PPY †† 0.45 Not reported Adverse Events in Treatment Group (n = 140) Patients with Event # Events Event Rate PPY † Bleeding Requiring surgery21 (15.0%) GI bleeding13(9.3%) Infection Localized non-device34(24.3%) Driveline exit15(10.7%) Sepsis9(6.4%) Pump Pocket0(0.0%)00.0 Stroke Ischemic 2,3 10(7.1%) Hemorrhagic4(2.9%)40.05 TIA7(5.0%)70.08 †† Pagani, et al. JACC 54: , 2009; Patient-Years † Patient-Years 2 Five of 10 (50%) ischemic strokes occurred in first 48 hours following HVAD implant 3 Eight of 10 (80%) of ischemic stroke patients recovered to Modified Rankin Scores ≤ 3

Pagani, et al. Event Rate PPY †† Patients with Event # Events Event Rate PPY † Ventricular Arrhythmias11(7.9%) Right Heart Failure RVAD requirement4(2.9%)40.05 Inotropic support27(19.3%) Peripheral TE9(6.4%)90.10 Hemolysis2(1.4%)20.02 Hepatic dysfunction4(2.9%)40.05 Respiratory Failure27(19.3%) Renal Failure13(9.3%) Device Replacement Low INR thrombosis3(2.1%)30.03 Surgery related3(2.1%)30.03 Exchange for BiVAD1 (0.7%)10.01 TOTAL7(4.9%)70.07 †† Pagani, et al. JACC 54: , 2009; Patient-Years † Patient-Years Adverse Events in Treatment Group (n = 140)

Treatment assignment was not randomized and therefore relevant baseline characteristics may differ between groups Difficult to compare clinical trial outcomes to those of a national registry due to differences in data collection and adjudication Serial assessment of functional capacity and quality of life were limited by inability to collect data on some critically ill patients, possibly leading to underestimations of the true benefits of investigational device therapy ADVANCE Trial: Study Limitations

Implantation of the small, continuous-flow HVAD pump contained in the pericardial space was associated with a high probability of success (92%) at 180 days HVAD pump demonstrated noninferiority to contemporaneously implanted, commercially available ventricular assist devices – 1.4% 30-day mortality – 94% survival at 180 days, 91% survival at 360 days Favorable adverse event profile when used as a BTT Marked improvement in functional capacity and quality of life improvements similar to those obtained with cardiac transplantation ADVANCE Trial: Conclusions