Introduction A modification of the Fricke solution system to make it suitable for low-level dosimetric studies was proposed about three decades ago [1].

Slides:



Advertisements
Similar presentations
Spectrophotometers and Concentration Assays
Advertisements

Advanced Biochemistry Lab : Determination of Nitrogen and Crude protein Ms. Nadia Amara.
ANALYTIC METHODS II. PART Jana Švarcová.  Chromatography  Electrophoresis  Potentiometry  Titration  Spectrophotometry.
Chapter Eleven Ultraviolet-Visible Spectrophotometry
Introduction Radiosensitive polyacrylamide gels (PAG) provide a method of mapping dose distributions in 3D with sub-millimetre resolution [1]. Largely.
Fricke gel dosimeters for the measurement of the anisotropy function of a HDR Ir-192 brachytherapy source Mauro Carrara 1, Stefano Tomatis 1, Giancarlo.
Lic. Pedro Antonio Pérez.  To develop a simple and versatile dosimetric method capable of determining changes in matter (Xylenol Orange added Fricke.
Deciding between physical and chemical changes
Introduction A Fricke gel was the first dosimetric system to offer the possibility of making 3-D radiation dose measurements in a totally non-destructive.
Introduction Three-dimensional gel dosimetry is a novel method for radiation measurement motivated by the need to verify experimentally the doses produced.
Introduction Spectrophotometry has been the conventional technique for measuring optical density of irradiated gels [1]. Later, magnetic resonance imaging.
UV / visible Spectroscopy
Introduction Following Gore’s observation [1] that the well known method of Fricke dosimetry [2] was ideally suited to a “readout” by Nuclear Magnetic.
How much iron is in an iron tablet?
Identifying Unknown Substances
Lecture 2b. Electromagnetic Spectrum Visible range: = nm Ultraviolet: = nm Low energyHigh energy.
Determination of Iron in Water
Determination of Iron in Water
Precipitation Analysis Considering the formation of solid from solution. Q vs. Ksp Ion Analysis.
Test of the proposed method Introduction CCD Controller CCD Illuminator gel Filter 585nm Assembling the phantom before its irradiation. The phantom, ready.
TÍTULO DO TRABALHO NOMES DOS AUTORES ENDEREÇOS E DOS AUTORES INTRODUTION Gammacell 220 Series 39 is a irradiation device purchased by CDTN/CNEN in.
Evaluation of the Performance of the Fast Scanning Platform of an OCT System Malcolm Heard 1, Miguel Herrera 1, Geoffrey Ibbott 1 1 Department of Radiation.
Introduction to Analytical Chemistry
C2- Chemistry Analysing substances, making salts, acids and bases
CHAPTER 12 ELECTRODE POTENTIALS AND THEIR APPLICATIONS TO XIDATION/REDUCTION TITRATIONS Introduction to Analytical Chemistry.
Chemical Synthesis Module C6. Chemical synthesis: chemical reactions and processes used to get a desired product using starting materials called reagents.
Fig. 3 shows how a dose distribution that is initially relatively sharp becomes blurred with time, until after 16 hours, virtually no useful information.
Spectrophotometers and Concentration Assays
Technical development of a high resolution CCD-based scanner for 3-D gel dosimetry: (I) Scanner construction S J Doran, K K Koerkamp*, M A Bero, P Jenneson,
CALIBRATION METHODS. For many analytical techniques, we need to evaluate the response of the unknown sample against the responses of a set of standards.
CHAPTER 4 Analysis of Variance One-way ANOVA
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 H. Albus Basic Course Experiments to Demonstrate.
Correlation Forensic Statistics CIS205. Introduction Chi-squared shows the strength of relationship between variables when the data is of count form However,
Conclusions Despite being able to acquire successfully high resolution images of radiation dose, image quality is limited by hardware problems. Upgrading.
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
Analysing Acids and Bases
Investigation into the radiochromic (FXG) gel dosimeter: stability and uncertainty in optical measurements M A Bero, S J Doran and W B Gilboy Department.
Lab Session 5 What is the relationship between a substance’s color and the light it absorbs?
Colorimetric determination of manganese in steel
Spectrophotometry at a Glance
COLORIMETRY & SPECTROPHOTOMETR
Chapter 1: The Nature of Analytical Chemistry
Section 15.1 Forming Solutions 1.To understand the process of dissolving 2.To learn why certain substances dissolve in water 3.To learn qualitative terms.
Spectrophotometers and Concentration Assays Chapter 7.
THIN LAYER CHROMATOGRAPHY.
Experiments with Iron and Sulfur HW 1-2. Iron Filings and Sulfur Iron Filings Initial observation of iron filings: dark gray particles; attracted to a.
Fundamentals of Analytical Chemistry Eighth Edition.
Agarose Gel Electrophoresis
Chemical Calculations
Temporal Thin Film Stability Studies Using Silver Nanoparticles
Quantitative tests for proteins
Science- Chapter 9 Chemical Compounds
Unit 1 Revision: Reaction Rates
Introduction to Spectrophotometry
Prof. Sergiy Lavrynenko National Technical University “Kh. P. I
Photooxidation of Alcohols. Paul Linklater, Cathy McCullagh, Peter K.J. Robertson, Stephen Macmanusa Centre for Research in Energy + Environment, The.
Homogeneous Aqueous Systems
Quantitative tests for proteins
Lecture 2b Beer’s Lambert Law.
What type of reaction is this?
What type of reaction is this?
IYNT 2017 NANJING Team BULGARIA
Quantitative tests for proteins
Experiments with Iron and Sulfur
Agarose Gel Electrophoresis
Zlata Tofzikovskaya, Christine O’Connor and Mary McNamara.
Finding Out about Matter
Agarose Gel Electrophoresis
Titanium Dioxide Sensitized with Porphyrin Dye as a Photocatalyst for the Degradation of Water Pollutants Kevin Reyes, A.S. & Ivana Jovanovic, Ph.D. Department.
Clinical instrumental analysis
Presentation transcript:

Introduction A modification of the Fricke solution system to make it suitable for low-level dosimetric studies was proposed about three decades ago [1]. A xylenol-orange metal-ion indicator is added to the standard Fricke reagent allowing the radiation effects to be detected by a visible colour change. Ferric ions form a complex with xylenol whose maximum absorption is at approximately 550 nm, whilst ferrous ions do not form the same complex. Hence, changes in the ferric ion concentration result in proportional changes in the light absorption. This modified chemical dosimetry system was infused into agarose gel and the resulting visible changes were suggested to as an alternative to the MRI readout for 3-D dosimetry [2]. In this poster, we describe our method of producing the colour-change Fricke Xylenol-Orange Gelatin (FXG) gel and examine the following issues concerning its properties: How much more sensitive is the colour-change gel than its original UV-active predecessor? How stable is the gel to natural oxidation? How reproducible are the results? Investigation into the radiochromic FXG gel dosemeter: stability and uncertainty in optical measurements Acknowledgements MB is sponsored by the Radiation Protection Department, Atomic Energy Commission of Syria, Damascus References [1] B L Gupta, IAEA-sm-160, 421 (1972) [2] A Appleby, A Leghrouz, Med. Phys. 18, 309 (1991) [3] M J Day, Phys. Med. Biol. 35, 1605 (1990) Conclusions The radiochromic gel detector clearly has the advantage of being much more sensitive than other Fricke systems proposed to measure radiation dose distributions in three-dimensions. Unwanted side effects are its sensitivity to light, temperature and storage time. Nevertheless, in a long-term study results the dose- response of the system was reproducible to 10% despite the use of different batches of chemicals. S M A Bero, S J Doran and W B Gilboy Department of Physics, University of Surrey, Guildford, GU2 7XH, UK Figure 2: Change in the optical absorbance of FXG gel with time when stored under three different conditions Time (hours) Optical absorbance cm -1 Figure 3: Repeatability study for different batches of the FXG gel made using nominally the same production technique. Chemical batches and suppliers varied. relatively low melting point and hence very little loss of dissolved oxygen during gel manufacture; high degree of transparency (others materials, e.g., agarose and agar, are translucent); important role in the enhancement of the dosemeter chemical yield of Fe 3+ (hence no need for the addition of any other organic substances, such as benzoic acid). Materials and methods Gelatin powder (C 17 H 32 N 5 O 6 ) x was used for almost all studies and was employed because it has important properties for Fricke colour-change measurements: The other reagents used in our preparations were as follows: ferrous ammonium sulphate hexahydrate, Fe(NH 4 ) 2 (SO 4 ) 2 6H 2 O; the sodium salt of xylenol orange, C 31 H 28 N 2 O 13 SNa 4 ; sulphuric acid, purified water, obtained from a Milli-Q ion-exchange purification system (Millipore UK-Limited, Watford, England). The quality of the water was found to have a significant effect on the gel response. The system is usually made of two parts, the gel part, which provides 75% of the final volume and the active chemicals that make up the other 25%. The first part contains 5% (by weight of the final solution) gelatin powder, mixed with 75% of the dosemeter volume water, and is left for about 15 minutes to absorb. Then the water-gelatin mixture is heated and continuously stirred until the solid particles have completely dissolved and a clear solution is obtained. This occurs at about 40 o C, but in practice, heating is continued up to 45 o C. The active chemical part normally contains the following concentrations of reagent (calculated with respect to the final volume of the gel dosemeter): 0.5mM Fe 2+, 0.25mM H 2 SO 4, 0.1mM xylenol orange. The two parts were mixed together at about 35 o C and the resulting solution left to solidify in a fridge. Results Dose-Response: Fig. 1 shows a comparison between the optical absorbance dose-response curves for FXG (measured at 585 nm), non-radiochromic Fricke gel (at the “traditional” UV wavelength of 304 nm) and the conventional ferrous-sulphate solution dosemeter (also at 304 nm). The changes in the optical absorption are approximately 23 times larger in the FXG compared with that of the standard ferrous sulphate solution and it has been suggested [4] that using such a system, doses as small as 0.01Gy might be measureable. Stability under different storage conditions: It is well known that ferrous ions are naturally oxidised to ferric in the presence of dissolved oxygen and this process depends on the concentrations of ferrous ions as well as the oxygen in the aerated aqueous medium. It has been reported that the natural oxidation effect is proportional to the square of the initial Fe 2+ concentration and to the first power of dissolved oxygen. Over long periods, the formation of the colour complex is strongly influenced by the ambient temperature and light, as can be seen from Fig. 2. In this study, a change in the optical absorbance of about 7  cm -1 per hour of storage time was observed for samples kept in the dark at 4 o C. Repeatability of measurements: A long term study has been undertaken over three years, involving the manufacture of 25 separate batches of gel. In each case, 10 samples of a batch of gel were irradiated at each of a number of doses. Typical coefficients of variance of optical absorption within a gel batch were 0.14% at 440 nm and 1.3% at 585 nm. However, studying different dosemeter batches prepared with the same procedure revealed much larger variations in the dosemeter sensitivity to ionising radiation, as shown in Fig. 3. The overall coefficients of variance were 11% and 10% for wavelengths 440nm and 585nm respectively. Average dose response curve slopes were cm -1 Gy -1 and cm -1 Gy -1 respectively. Figure 1: Comparison between the optical dose response for “traditional” Fricke solution and Fricke gel (both at 304 nm, the standard UV spectrophotometry wavelength) and FXG gel at 585 nm, the peak of the absorption curve