Industrial Process Control: CONTROL OF HEAT EXCHANGER

Slides:



Advertisements
Similar presentations
OFF DESIGN PERFORMANCE PREDICTION OF STEAM TURBINES
Advertisements

Assumptions: Incompressible substance, B. Negligible heat transfer
Circulating Water System
HEATING AIR © Commonwealth of Australia 2010 | Licensed under AEShareNet Share and Return licence.
Moisture to water converter. Out Line : Abstract Introduction Heat Pump Heat Pump Components Conclusion.
Basic Refrigeration Cycle
STEAM TRAPS.
Refrigeration Flow Control
CHE 185 – PROCESS CONTROL AND DYNAMICS
Cooling As working temperatures rise, the strength of metals used reduces. This in turn will force manufacturers to use superior metals/alloys, which can.
CHAPTER V CONTROL SYSTEMS
3442 Industrial Instruments 2 Chapter 9 Controller Principles
COMMERCIAL REFRIGERATION
LECTURE#08 PROCESS CONTROL STRATEGIES
Section 5: Commercial Refrigeration
Chapter 3.2: Heat Exchanger Analysis Using -NTU method
2005/2006 I. Hydraulic and Pneumatic Systems1 Pressure reducing valves Task: They have the task to provide a constant secondary pressure p 2, independently.
CHE 185 – PROCESS CONTROL AND DYNAMICS
Control System Instrumentation
Lecture 3 Control valves.
Lesson 15 Heat Exchangers DESCRIBE the difference in the temperature profiles for counter-flow and parallel flow heat exchangers. DESCRIBE the differences.
Product Introduction.
Chemical Engineering 3P04 Process Control Tutorial # 2 Learning goals 1.The feedback cause-effect principle 2. Key element in the loop: The control valve.
Chapter 18 Control Case Studies. Control Systems Considered Temperature control for a heat exchanger Temperature control of a CSTR Composition control.
CONTROL VALVE - THEORY & SIZING
Chapter 3.1: Heat Exchanger Analysis Using LMTD method
Hydronic Mechanical Controls
Steam Traps Function and Types.
Cascade, Ratio, and Feedforward Control
P&ID Design and Equipment Selection
Process Operability Class Materials Copyright © Thomas Marlin 2013
Gas Chromatography Carrier Gas Flow Control Injector Port Column Column Oven Detector Recorder The GC system consists of gas supplies for the mobile phase.
Temperature Control Loop
Control System Instrumentation
CHAPTER 5: Mass and Energy Analysis of Control Volumes
Topic 5 Enhanced Regulatory Control Strategies. In the previous lecture…  Plant test  Interacting loops.
Solar Heating/Cooling/Dehumidifier Systems
PASTEURIZATION AND BLANCHING PURPOSE OF THE PROCESSES DESCRIPTION OF PROCESSING SYSTEMS ESTABLISHMENT OF THE PASTEURIZATION PROCESS DETERMINATION OF BLANCHING.
Refrigeration Cycles A Carnot cycle in reverse QL QH T s 2
Heat Transfer Su Yongkang School of Mechanical Engineering # 1 HEAT TRANSFER CHAPTER 8 Internal flow.
TITLE OF THE PROJECT:- AUTOMOBILE AIR CONDITIONING AIM OF THE PROJECT:- TO STUDY ABOUT AIR CONDITIONING SYSTEM OF AN AUTOMOBILE PRESENTED BY: INAMUL.
MISS. RAHIMAH BINTI OTHMAN
Session 6 - Agenda BREAK Activity Est. Time 1. Agenda
Chapter 10: Flows, Pumps, and Piping Design
James McIntyre VRF Training Manager V5 Key Components.
CENTIFUGAL PUMP OPERATION
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
Heat Transfer and Refrigeration Cycle
GROUND SERVICING OF VARIOUS SUB SYSTEMS
Induction System – carburetor circuit
Heat Exchangers and Condensers
CHAPTER V CONTROL SYSTEMS
Mass and Energy Analysis of Control Volumes
Simple Thermal Power Plant
TOPIC:- VAPOUR CYCLES CREATED BY:
Workshop for Flipped Class
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
HEAT EXCHANGER.
Maniks high efficiency Desuperheater for efficient heat transfer
Process Operability Class Materials Copyright © Thomas Marlin 2013
Process Equipment Design and Heuristics – Heat Exchangers
Control System Instrumentation
Control System Instrumentation
Step 2. Degree of freedom (DOF) analysis
Process Operability Class Materials Copyright © Thomas Marlin 2013
1 INTERNATIONAL MARITIME COLLEGE OMAN PROCESS TECHNOLOGY & SYSTEMS (TPTS & PT-TPTS) PE (TPTS & PT-TPTS) (Chapter-3) Chapter - 3 Distillation Systems Textbook.
12. Heat Exchangers Chemical engineering 170.
Presentation transcript:

Industrial Process Control: CONTROL OF HEAT EXCHANGER Nikhilbinoy.C Assistant Professor, ICE Department, N.S.S. College of Engineering, Palakkad.

Variable and Degrees of Freedom Control loops function on the basis of controlling one variable by manipulating the same or some other process variable. Maximum number of independently acting automatic controllers that can be placed on a process is called degrees of freedom. Degrees of freedom (DOF) = Number of variables – Number of equations

Terminology Types: Liquid-to-liquid heat exchanger Steam heater     Process Medium: - Process liquid Process Vapour Tube: - Through which cold fluid is flowing Types: Liquid-to-liquid heat exchanger Steam heater Condenser Reboiler Heat Transfer Medium: - Cooling liquid Cooling vapour Heating liquid Heating vapour Shell: - Filled with hot fluid    

Liquid-to-Liquid Heat Exchanger

Instrumentation and Control Cooler Here, the temperature of both process fluid and heat transfer fluid is changed. But the phase of these two fluids remains constant (as liquid). Heater               The fluid, whose temperature is relatively low, is flowing through the tube.   There are four temperature and two flow variables with one defining equation. DOF = 6 – 1 = 5

Instrumentation and Control TIC TIT TIT TIC Location of CV is desirably at heat transfer medium side. Mounted on the low temperature side. Provided positioner to minimize valve friction effect. Equal percentage valve is recommended, which will maintain control system gain under changing throughput condition. Keep the relationship between valve opening and temperature change constant.

Instrumentation and Control TIC TIT TIT TIC PID controller is used. ‘D’ is essential for long time lag, or sudden changes. ‘P’ is essential for relatively slowly nature systems. ‘I’ is essential to correct the temperature offset.

Instrumentation and Control Contradictory statements. Location of the thermal element is in between these two contradictory positions. TIC TIT TIT TIC Selection and location of thermal element is important. Be located far enough from the exchanger for adequate mixing. Close enough so that the introduced time delay will not be substantial.

Three Way Valves TIC If the process medium temperature is high, the TIC with respect to the measurement TIT opens the three way control valve, so that the flow rate of process medium through cooler is increased and flow rate of process medium through by-pass is decreased. So the temperature of process fluid is decreased, because more fluid is flowed through the cooler. TIC TIT TIT Diverter Valve Mixing Valve The limits within which process temperature can be controlled are function of the nature of the load changes expected and speed of response of the whole unit. In case the process time lag is too great, to allow for effective control during load changes, partially by-pass is used.

Three Way Valves Flow 100 0 100 Valve Opening Diverter Valve TIC Flow 100 0 100 Valve Opening TIT         Diverter Valve Three way valves are unbalanced designs. Normally provided with linear ports. Linear ports prevents the deviation from the relationship between valve movement and temperature changes. Equal percentage valve is used. Misalignment or distortion in a control valve installation cause binding, leakage at the seats, high dead band and packing friction. Due to high temperature service in three way valve.

Three Way Valves TIC TIC TIT TIT Diverter Valve Mixing Valve Due to high temperature service in three way valve, uniformity of valve temperature must be ensured. Temperature of fluid at all points of valve must be same. Diverted valve is favoured.

Balancing the Three Way Valve TIC TIT A manual balancing valve is installed in the exchanger by-pass line. This valve is so adjusted that the resistance offered by heat exchanger to flow equals the resistance offered by this hand valve.

Two Two-Way Valves TIC If it is unable to use three-way valve due to temperature and other considerations, two two- way valve is used to improve the performance. Linear plugs are used to get the same performance of three-way valve. Cost is increased. Price of three-way valve is 65% of two two-way valves. Capacity of three-way valve is equal to capacity of single ported two-way valve (equal to 70% of capacity of double ported two-way valve). TIT FO FC

Steam Heater Loop components, accessories, sensor location and time lag considerations discussed in liquid-to-liquid heat exchanger is also applicable here. Use of equal percentage valve is more pronounced here. High rangeability is required due to high variation in condensate pressure.

Instrumentation and Control   Used to increase the temperature (to heat) of process fluid. Phase (dynamics) of process fluid is not changed. Phase (dynamics) of heat transfer medium is changed from steam to water. Due to the change in dynamics, the outlet flow rate is almost constant, only the inlet flow rate varies with respect to the performance of steam heater. So control valve is located at the inlet side (except at some special conditions). Due to the change in dynamics, the temperature of heat transfer medium is independent of the heat transfer process. Therefore the number of variables are 4. DOF = 4 – 1 = 3    

Instrumentation and Control Condensate line is a function of load when the temperature is controlled by steam inlet. Low load and low operating temperature results in a below atmospheric condensing pressure. This condensate pressure is not sufficient to discharge the condensate (liquid) through the steam tap, which accumulates inside the exchanger. More and more heat transfer area will cover up, resulting in a corresponding increase in condensate pressure. When this pressure rises sufficiently to discharge the trap, the condensate is suddenly blown up (a big upset). The control of temperature is impossible in this special case. FC TIC TIT

Control Valve in the Condensate Line Reduces the blown up problem. Cost is the another advantage, because the size of the control valve is small here. Has no effect on steam pressure. Accurate temperature control is not possible. Due to change in dynamics. FC TIC TIT TIT TIC

Level Controller Low condensing pressure is a result of the combination of low load and high heat transfer surface area. Reducing heat transfer area will prevent vacuum. Level controller is used instead of steam trap. FC TIC TIT LT LIC

By-pass Control TIC Advantages and disadvantages of this system are similar to liquid-to-liquid heat exchanger. By-pass gives additional degrees of freedom. Flow rate of liquid through the by-pass line is the additional variable. PIC PIT TIT FO

Cascade Loop on Steam Heater The change in dynamics has great effect on the steam pressure. Dynamics may change with respect to steam purity, etc. To reduce the effect of load changes, steam pressure is also controlled. SP PIC TIC PIT TIT

Condenser

Instrumentation and Control Used to condense the process vapour to liquid. Phase (dynamics) of the process fluid changes from vapour to liquid. Phase (dynamics) of the heat transfer medium remains constant (as liquid). The number of variables are four. DOF = 4 – 1 = 3

Instrumentation and Control Process Vapour Source Process Vapour Source PIT PIC FO FO TIT TIC Condensate Accumulator Condensate Accumulator Both of these throttle the cooling water flow through the condenser. For efficiency, water velocity through the condenser should be such that its residence time does not exceed one minute.

Instrumentation and Control When it is not desirable to throttle the cooling water, this system is used. Exposed condenser surface is varied to control the rate of condensation. When recondensables are present, a constant purge is used to remove inert. Non-symmetricity. Process Vapour Source Vent PIT PIC FO Condensate Accumulator

Reboiler and Vaporizer

Instrumentation and Control Used to vaporize the process liquid by using steam. Phase (dynamics) of the process fluid changes from liquid to vapour. Phase (dynamics) of the heat transfer medium changes from vapour to liquid. Both medium have the change of phase. The number of variables are two. DOF = 2 – 1 = 1

Instrumentation and Control Only variable to control is the rate of steam. TIT TIC FC

Remember??! Even if not so perfect, the inclusion of by-pass will increase the number of degrees of freedom. Effective for the processes which have a very small DOF.