Challenges for TPS Chunhua Men Elekta Software, Treatment Planning System BIRS Workshop Banff, Canada 3/12/2011.

Slides:



Advertisements
Similar presentations
Surface contour scanning system
Advertisements

بسم الله الرحمن الرحيم ﴿و قل رب زدنى علماً﴾ صدق الله العظيم.
Harvard Medical School Massachusetts General Hospital.
CLINICAL WORKSHOP Image-Guided Adaptive Brachytherapy for Gynaecology Hospital name Participants’ names and roles Vienna, November 2013.
RapidArc plan verification using ArcCHECK™
Managing uncertainty using robust optimization Timothy Chan University of Toronto BIRS radiation therapy workshop March 12, 2011.
10th Annual Lung Cancer Conference Radiation Oncology
Copyright ©2008 Accuray, Incorporated. All rights reserved E CyberKnife ® Robotic Radiosurgery System Radiosurgery System Comparisons.
Anatomy-based MLC Field Optimization for the Treatment of Gynecologic Malignancies Myriam Bouchard M.D. Nadeau S, Germain I, Raymond P.E., Harel F, Beaulieu.
Radiotherapy Planning Stephen C. Billups University of Colorado at Denver
D.G.Lewis Department of Medical Physics Velindre Cancer Centre Whitchurch, Cardiff RT-GRID: Grid Computing for Radiotherapy.
Dose Calculations A qualitative overview of Empirical Models and Algorithms Hanne Kooy.
Comparing the Streamline Diffusion Method and Bipartition Model for Electron Transport Jiping Xin Department of Mathematical Science, Chalmers University.
Department of Radiation Physics, Royal Derby Hospital
TREATMENT PLANNING PHOTONS & ELECTRONS Karen P. Doppke 3/20/2007.
The TrueBeam System ™ Clinic Name Presenter’s name Clinic location
Real-time tumor tracking with preprogrammed dynamic MLC motion and adaptive dose-rate regulation B.Y Yi, S. Han-Oh, F. Lerma, B. Berman, C. Yu.
Radiation Therapy (RT). What is cancer? Failure of the mechanisms that control growth and proliferation of the cells Uncontrolled (often rapid) growth.
1 Improved critical structure sparing with biologically based IMRT optimization X.Sharon Qi, Vladimir A. Semenenko and X. Allen Li Department of Radiation.
What is radiation therapy (RT)? Cancer treatment Tumor versus normal tissues External photon beam RT.
Quality Assurance: Manufacturer & Clinical Aspects  Alan Cohen, M.S. DABR  Paul Naine, MSc. MIPEM  Jim Schewe, PhD, DABMP Accuray Incorporated Elekta.
Radiotherapy for Brain Tumours What do I need to know? Dr Matthew Foote Radiation Oncologist Princess Alexandra Hospital Queensland.
THE DICOM 2013 INTERNATIONAL CONFERENCE & SEMINAR March 14-16Bangalore, India Experiences in building DICOM module for Proton radiation therapy planning.
WELCOME!!! FDA & MITA RT Meeting
Stereotactic Body Radiation Therapy (SBRT): The optimal indication for operable tumors in inoperable patients D.Katsochi 1, S.Kosmidis 1, A.Fotopoulou.
Volumetric Modulated Arc Therapy (VMAT)
Radiotherapy Planning for Esophageal Cancers Parag Sanghvi, MD, MSPH 9/12/07 Esophageal Cancer Tumor Board Part 1.
Impacting Radiotherapy Safety and QA with Device Improvements Benedick A Fraass, PhD, FAAPM, FASTRO, FACR Allen S. Lichter Professor of Radiation Oncology.
Radiotherapy Treatment Planning
Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator Andrew J Reilly Imaging Physicist Oncology Physics Edinburgh Cancer.
به نام خداوند بخشایندۀ بخشایشگر
Evaluation of New Pre-Treatment In-Air Patient Specific QA Software for TomoTherapy Treatments Lydia L. Handsfield¹, Quan Chen¹, Kai Ding¹, Wendel Renner²,
The external beam radiotherapy and Image-guided radiotherapy (2)
Data Mining to Aid Beam Angle Selection for IMRT Stuart Price-University of Maryland Bruce Golden- University of Maryland Edward Wasil- American University.
Applications of Geant4 in Proton Radiotherapy at the University of Texas M.D. Anderson Cancer Center Jerimy C. Polf Assistant Professor Department of Radiation.
1 4D: Adaptive Radiotherapy & Tomotherapy Bhudatt Paliwal, PhD Professor Departments of Human Oncology & Medical Physics University of Wisconsin Madison.
MIT and James Orlin © More Linear Programming Models.
Institute for Advanced Radiation Oncology
Medical Accelerator F. Foppiano, M.G. Pia, M. Piergentili
Integrating the Health Care Enterprise- Radiation Oncology Use Case: In Vivo Patient Dosimetry Editor: Juan Carlos Celi - IBA Reviewer: Zheng Chang – Duke.
Dosimetric discrepancies due to positional errors in MLC movement during stereotactic lung VMAT A. Abbas, T. Karan, S. Kim, D. J. Moseley, M. M. Taremi,
1 A Comprehensive Study on the Heterogeneity Dose Calculation Accuracy in IMRT using an Anthropomorphic Thorax Phantom S Davidson 1, R Popple 2, G Ibbott.
The Answer to Your Dosimetry Needs
1 Radiotherapy, hadrontherapy and treatment planning systems. Faiza Bourhaleb INFN-Torino University Med 1er-Morocco  Radiotherapy  Optimization techniques.
A Tumour Control Probability based approach to the development of Plan Acceptance Criteria for Planning Target Volume in Intensity Modulated Radiation.
TPS & Simulations within PARTNER D. Bertrand, D. Prieels Valencia, SPAIN 19 JUNE 2009.
“RADIATION ONCOLOGY 101” FOR THE HTM SERVICE PROFESSIONAL
Karolina Kokurewicz Supervisors: Dino Jaroszynski, Giuseppe Schettino
Flair development for the MC TPS Wioletta Kozłowska CERN / Medical University of Vienna.
Understanding Radiation Therapy
The Effects of Small Field Dosimetry on the Biological Models Used In Evaluating IMRT Dose Distributions Gene Cardarelli,PhD, MPH.
Treatment Chart Record of patients radiation therapy history. Must contain: History and diagnosis Rationale for treatment Treatment plan Consent Documentation.
Beam specific PTV incorporating 4DCT for PBS proton therapy of thoracic tumors Minglei Kang, PhD Authors: Liyong Lin1*, Minglei Kang1*, Sheng Huang1,
Medical Dosimetry Presented by (Add Hospital name) in conjunction with The American Association of Medical Dosimetrists.
Understanding Radiation Therapy Lecturer Radiological Science
Radiotherapy treatment planning technology: present and future
Fast & Accurate Biophotonic Simulation for Personalized Photodynamic Cancer Therapy Treatment Planning Investigators: Vaughn Betz, University of Toronto.
Second Generation Radiotherapy C-Arm RT Treatment Modalities
Extending intracranial treatment options with Leksell Gamma Knife® Icon™ Key Statements from Customer Perspective by University Medical Centre Mannheim.
Very High Energy Electron for Radiotherapy Studies
Implementation of Object Spot Avoidance in Proton Pencil Beam Treatment on Whole Breast with Implant Metal Injector Peng Wang, PhD, DABR, Karla Leach,
Fig. 4. Percentage of passing rate between clinical and 544 plans.
Insert tables Insert figure
Volumetric Modulated Arc Therapy (VMAT) versus Intensity Modulated Radiation Therapy (IMRT) for Anal Carcinoma Heather Ortega, BSRT(T), CMD, Kerry Hibbitts,
Radiation Oncology Department, Bank of Cyprus Oncology Center.
Second Generation Radiotherapy C-Arm RT Treatment Modalities
Clinical Radiation Oncology NMT232 L 10
Chapter 17 Intensity-Modulated Radiation Therapy
FOUNDATIONS OF MODERN SCIENTIFIC PROGRAMMING
GHG meeting at ESTRO36 May, 2017
Presentation transcript:

Challenges for TPS Chunhua Men Elekta Software, Treatment Planning System BIRS Workshop Banff, Canada 3/12/2011

Overview Challenges Conclusions Outline

Radiation Therapy Treatment Planning System treatment planning system (TPS) for radiation therapy allows dosimetrists, physicists, and physicians to create, select, and verify the treatment plans for their patients efficiently with high quality Good

Radiation Therapy Techniques  Delivery techniques: 1) external beam 2) brachytherapy  Linear accelerator x-ray (external beam): 1)Conventional linear accelerator - categorized by the modulation techniques: i.3D CRT ii.Conformal arc iii.IMRT (step-and-shoot, dMLC) iv.VMAT 2)Neurosurgery (Gamma Knife, CyberKnife) 3)TomoTherapy

Roles of TPS in Radiation Therapy  Tumor and OAR contouring  Forward planning (3D CRT, conformal arc) 1)Beam setup (isocenter, beam angles, etc.) 2)Dose calculation  Inverse planning (IMRT, VMAT) 1)Beam setup (isocenter, beam modality, beam angles/arcs, etc.) 2)Prescriptions 3)Dose calculation and plan optimization  Plan evaluation, QA, export, etc.

Why Challenges Exist?  The increasing complexity of treatment techniques: more and more components are involved in treatment o 3D CRT → conformal arc → IMRT → VMAT → … MLC moving, gantry moving, couch moving, next? o photon, electron → proton→ carbon→ ion→ …  Higher and higher request on plan quality o Static → Dynamic: robust /4D planning and adaptive RT: be able to handle motion (inter-fractional and intra-fractional)  More efficient treatment o reduced MU / treatment time  More efficient planning o on-line / real-time planning

Big Picture: Challenge 1 Can you offer a strong, integrated single product which includes all state of the art technologies and supports technological innovation, enable changing practice trends, with very high efficiency?  Implement different components from different vendors?  Supporting all modalities?  Hybrid treatment planning?  Quickly implement new emerging techniques?

Big Picture: Challenge 2  Can you let me know what is the best achievable plan?  The fact: current TPSs ask user to specify prescriptions (tumor prescribed dose, DVH constraints, etc.) and/or optimization parameters (weighting factors, penalty thresholds, etc.) o Pre-setting weighting factors is a weighted sum method (a branch of multi-criteria optimization) o Same prescriptions/parameters may lead to very different plans using different TPSs; slightly different prescriptions/parameters may lead to very different plans o Different physicians may choose different plans as the “best” ones  The possible solution o More sophisticated multi-criteria optimization / decision making methods o The optimization of a given system vs. the design of the optimal system

Big Picture: Challenge 2 - Two Facts (from Wikipedia )  “Instead of being a unique solution to the problem, the solution to a multi-objective problem is a possibly infinite set of Pareto points” o Question: How to identify finite set of solutions provided to user? o Pre-calculating plans and interactive planning are time- consuming and may hit-and-miss o User needs a fast algorithm!  “There are many MCDA / MCDM methods in use today. They all claim that they can accurately solve this type of problem. However, often different methods may yield different results for exactly the same problem”

Big Picture: Challenge 3 Goal: Implement biologic information into optimization and predict biological outcome at course and fraction level  Background: radiobiological response of tumor and normal tissue is dependent on many factors: cell sensitivity to radiation, cell cycle, hypoxia,...  Currently: static CT (only electron density information)  Ideally: integrate more biological information into planning (patient level, organ level, voxel level?)

Cell Response Cell cycle Monaco (from Elekta) has implemented cell sensitivity, but just a single value at this moment M: Most sensitive S: least sensitive Cell sensitivity

Hypoxia and Re-oxygenation

Big Picture: Challenge 3 –cont.  Difficulty #1: Acquiring biological information before planning and during treatment: MRI, PET, and ?  Difficulty #2: Accurate modeling of the biological response - huge mount of data needed  Difficulty #3: Uncertainty or variation of biological outcome during treatment

 Can you further improve IMRT treatment quality? o Beam orientation optimization (BOO) has been investigated by many researchers, but none works well (in terms of effectiveness and efficiency) The angles are chosen based on user’s experience o In most TPSs, IMRT treatment plans are developed using a two- stage process (fluence map optimization problem is followed by a leaf-sequencing stage). The treatment quality gets worse a lot in Stage 2. Direct aperture optimization has been investigated for many years, but only simulated annealing algorithm has been used in commercial TPS which is a heuristic-based method and time-consuming Can you improve VMAT treatment quality? Small Picture: Optimization Technique Related Challenges

 The accuracy of input data for 4D/robust optimation  Adaptive RT (workflow, efficiency, CBCT image quality, dose accumulation, etc. )  Dose calculation: pencil beam – fast but inaccurate; Monte Carlo – accurate but slow  Auto-contouring  And more… Small Picture: Non-optimization Technique Related Challenges

Non-technical Challenge  How to minimize the gap between the research outcomes and clinical applications? o Fact 1: research outcomes lead to clinical applications o Fact 2: clinical applications are far behind research outcomes

 There are many technical and non-technical challenges for TPS  To overcome the challenges 1.Much more research work is needed 2.More researchers from various research areas need to be involved in: imaging, data processing, modeling / optimization, and more... 3.More radiobiologists, radiologists, radiation oncologists and medical physicists input is required 4.More vendors need to be involved 5.Overall, more collaborations are needed Conclusions