Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques.

Slides:



Advertisements
Similar presentations
Exercise Physiology McArdle, Katch, & Katch – Ch. 16
Advertisements

Body Composition. Body Composition Densitometry Measurement of body density by underwater weighing Density= body mass(kg) Body volume(l) %body fat.
Medical Interventions Mrs. Stewart Central Magnet School
MRI- Magnetic resonance imaging
Body Composition.
Body Composition. Body Composition Densitometry The difference in weight in a person in air and after submerging in water can be used to work out volume.
Restricted © Siemens AG 2013 All rights reserved.siemens.co.uk/education Topic 15: A peep inside Siemens Education.
Nuclear Medicine Spring 2009 FINAL. 2 NM Team Nuclear medicine MD Nuclear medicine MD Physicist Physicist Pharmacist Pharmacist Technologist Technologist.
Information Technology for the Health Professions, 2/e By Lillian Burke and Barbara Weill ©2005 Pearson Education, Inc. Pearson Prentice Hall Upper Saddle.
Chapter 4 Radioactivity and Medicine A CT scan (computed tomography) of the brain using X-ray beams.
Computed Tomography. Introduced in 70’s Principle: Internal structures of an object can be reconstructed from multiple projections of the object.
Magnetic Resonance Imaging
Clinical Assessment of Body Composition Marta Van Loan, Ph.D USDA, Western Human Nutrition Research Center
PHYSICS IN NUCLEAR MEDICINE: QUANTITAITVE SPECT AND CLINICAL APPLICATIONS Kathy Willowson Department of Nuclear Medicine, Royal North Shore Hospital University.
Medical Imaging. X-Rays What is a Routine X-Ray? The X-ray has been called one of the most significant advances in all of medical history. It is used.
Body Composition Techniques 2
Bone Mineral Density Testing March 29, Introduction Osteoporosis is a systemic skeletal disorder characterized by decreased bone mass and deterioration.
Skinfold Measures.
 Definition: describes the percentages of fat, bone, muscle, and fluid that make up body weight.  Because muscular tissue takes up less space in our.
Sport Books Publisher1 Body Composition. Sport Books Publisher2 Body Composition There are three interrelated aspects of the human physique: Size (volume,
Saira Ahmad UOG. CAT Scans CAT Scans ( Computerized axial tomography) Topic:
Chemistry and Imaging. Body Chemistry In order to be an effective health care professional, an individual must have an understanding of basic chemistry.
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University.
 An individual who performs radiography, radiation therapy, or nuclear medicine technology.
Body Composition Techniques
Nuclear Energy Effects and Uses of Radiation
Medical Imaging Technology
MEDICAL IMAGING.
3/13/2009IB Physics HL 21 Ultrasound Medical Imaging Physics – IB Objectives I.2.7Describe the principles of the generation and the detection of ultrasound.
Magnetic Resonance Imaging
1 Nuclear Radiation Natural Radioactivity A person working with radioisotopes wears protective clothing and gloves and stands behind a shield.
The Nucleus and Radioactivity
NS 210 Unit 6 Seminar Anthropometrics. Anthropometry Definition – The measurement of body size, weight and proportions – Adherence to technique is critical.
 Marie Curie ( ) and Pierre Curie ( ) were able to show that rays emitted by uranium atoms caused fogging in photographic plates. ◦ Marie.
Chapter 31 Nuclear Energy; Effects and Uses of Radiation.
Illinois State University Introduction to Body Composition Chapter 1.
Medical Imaging X-rays CT scans MRIs Ultrasounds PET scans.
Chapter 32 Radiochemical Methods. Introduction… Radiochemical methods tend to be labor intensive and generate liquid waste due to the chemical separations.
Illinois State University Body Composition: Children and Maturation Chapters 8 and 9.
4-Jun-161 ULTRASOUND IMAGING Lec 1: Introduction Ultrasonic Field Wave fundamentals. Intensity, power and radiation pressure.
Medical Procedures – Ionizing –X-Ray –CT Scan (Computed Tomography) –Nuclear Medicine Medical Procedures – Non-Ionizing –Ultrasound –MRI (Magnetic Resonance.
Methodology PET and MRI scanning How do we investigate the brain?
Section 1Nuclear Changes Section 1: What is Radioactivity?
Radiology started with simple traditional x-ray technology.
Radiation Sources in medicine diagnostic Radiology
Introducing cross- sectional imaging Dr.Ahmed S. Tawfeek FIBMS(Rad.)
Physiological psychology Are boys better at three point turns than girls?
DEFINITION: Describes the percentages of fat, bone, muscle, and fluid that make up body weight Factors that affect a person’s body composition: Heredity.
Body Composition Techniques. DIRECT ASSESSMENT The only direct methods for body composition assessment are dissection or chemical analysis Brussels Cadavre.
Unit 9, Chapter 30 Radioactivity. Vocabulary Terms  radioactive  alpha decay  beta decay  gamma decay  radiation  isotope  radioactive decay 
Brain Imaging Techniques
 This depends on a property of nuclei called spin.  Gyroscope: Principle: As long as its disc remains spinning rapidly the direction of the spin axis.
THE RELATIVE COMPARISON OF BODY FAT TO LEAN BODY MASS (MUSCLE, BONE, ORGANS). OR FAT WEIGHT COMPARED TO FAT FREE WEIGHT BODY WEIGHT = 200 LBS. %BODY FAT.
NS 215 Unit 6 Seminar Anthropometrics. Week 6 is HERE!! How was your week?
Medical Physics.
Nuclear Radiation Today Chapter 10.3 Notes. Where is radiation? Radiation is everywhere—the form of nuclear radiation that occurs naturally is called.
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
MAGNETIC RESONANCE IMAGING by PRADEEP V.EPAKAYAL. Mem.no L.
MEDICAL IMAGE ANALYSIS. Introduction Technology today is extremely advanced and now physicians can call upon a variety of imaging techniques to help examine.
Diagnostic Imaging Medical Interventions
Medical Imaging Illuminating the Body.
PGND 1st SEMESTER APPLIED NUTRITION-I
Body Composition.
4 Body Composition.
Diagnostic Imaging.
Unit 2 Scanning Techniques
Medical Imaging Imagining Modalities.
In Vivo Neutron Activation Analysis
BY Dr. Mohamed Samieh Lecturer in Radiology Department
Presentation transcript:

Complex Techniques Hydrometry Whole-Body Counting and Neutron Activation Analysis Dual Energy X-Ray Absorptiometry Imaging Techniques

Hydrometry Water is the most abundant of the constituents of the body. It makes up 70-75% of weight at birth, but less than 40% in obese adults.

Hydrometry Dilution Principle States that the volume of the compartment is equal to the amount of tracer added to the compartment divided by the concentration of the tracer in that compartment.

Hydrometry With this method, the concentration of either hydrogen or oxygen isotopes in biological fluids (e.g., saliva, plasma, and urine) after equilibration is measured and used to estimate total body water.

Hydrometry The tracers used in the in-vivo dilution do not behave in an ideal manner. Thus, measurement of TBW in-vivo requires careful attention to these deviations from the basic assumptions underlying the dilution principle.

Hydrometry Precision of total body water The precision of the total body water measurement is dependent on the analytical method as well as the dose of tracer administered to the subject.

Hydrometry In general, mass spectrometric methods have been the most precise. –Using two isotopes the precision is 1 - 2%. –Using other analytical methods the precision is between 2 - 4%.

Hydrometry Procedural variations such as the physiological fluid selected for sampling, equilibration time, the estimated correction factor for the isotropic dilution space, and the method selected for assaying the labeled water may all contribute to an increased technical error.

Whole-Body Counting Scintillation detectors were developed in the early 1950’s. They measure the body’s natural potassium as well as other radioactivity in the body.

Whole-Body Counting In 1958, Kulwich, Feinstein, and Anderson correlated natural potassium concentration with fat free mass.

Whole-Body Counting There are an estimated 75 counters in the US. There are more than 180 whole-body counters worldwide. Two-thirds of these perform body potassium measurements in humans.

Whole-Body Counting Potassium is naturally distributed in three isotopic states. The isotope 40K is radioactive.

Whole-Body Counting Gamma rays from 40K are high-energy gammas, many of which exit the body and can be easily detected by external counting The smaller the subject, the lower the 40K content and thus the weaker gamma signal.

Whole-Body Counting Factors such as age, fitness, or restricted mobility due to surgery or illness do not tend to affect the precision of total body potassium measurements. The 40K signal is natural and continuous, therefore the measurement can be interrupted as necessary, until counting is completed.

Whole-Body Counting The three requirements for 40K whole body- counting include: Efficient gamma-ray detectors that can be placed close to the subject. Shielding for these detectors to reduce the natural background radiation levels (cosmic rays, radioactive contaminants in construction materials)

Whole-Body Counting Computer-based instruments that enable identification of the unique gamma rays.

Whole-Body Counting Precision: For whole-body counters, precision is in the range of 2-5% for adults. In infants and very young children, accurate measurements have been difficult to obtain. The precision is only 8-12% for 40 minute sample times.

Whole-Body Counting Cost depends on age range of the population being examined. Total cost for an adult whole-body counter is $10,000-15,000. Cost of a special shielded room starts at $80,000. These are just start-up costs.

Neutron Activation Analysis IVNAA measures 11 elements from nuclear reactions. Protein, mineral, and fat can be estimated from these elements: –Carbon = Lipid –Nitrogen = Protein –Calcium = Bone

Neutron Activation Analysis IVNNA use a whole-body counter. It delivers a moderate beam of fast neutrons to the subject. Atoms of target elements capture these neutrons. This creates an unstable isotope.

Neutron Activation Analysis Unstable isotopes produce gamma rays when returning to a stable state. Gamma rays are measured: –energy level identifies the element –the activity indicates its abundance.

Prompt-Gamma Activation Analysis The isotope gets very excited with the added neurons. This lasts only a fraction of a nanosecond before it returns to a stable state. It is therefore measured simultaneously as the neutrons are exposed to the isotope.

Neutron Activation Analysis Disadvantages: Radiation exposure. Must be performed by medical personnel Cost $30,000 - $300,000.

Ultrasound Uses high frequency sound waves that are produced by a piezoelectric crystal in a transducer.

Ultrasound A common source of error is the occurrence of multiple echoes from connective tissue layers within the SAT, particularly over the abdomen.

Ultrasound The disadvantages of ultrasound, in comparison with calipers, are its greater expense and lesser portability. Careful site location is also crucial.

Ultrasound Its advantages over the measurement of skinfold thickness in the obese are now recognized more widely.

Dual Energy X-Ray Absorptiometry (DEXA) DEXA was originally developed to estimate bone mineral content. DEXA estimation of body fat is based on the attenuation of two energy x-rays through the body.

DEXA From each x-ray, DEXA software provides an estimation of the ratio of fat and lean tissue in each computerized pixel.

DEXA Femoral NeckLumbar Spine

DEXA To perform a DEXA reading, subjects lie in a prone position for approximately 12 minutes for an x-ray scan from head to toe.

DEXA This technology is attractive because it can be used to assess regional body composition as well. Additionally, this method requires virtually no effort on the part of the participant and does not depend on technician skill.

DEXA Applicability: DEXA is applicable through low radiation exposure. –Radiation levels are 100 times less than common x-ray.

DEXA Disadvantages: Can not be used during pregnancy. Special software required for infants.

DEXA Advantages: All ages are included. Low radiation as compared to common x- rays. Food or fluid intake have little affect on results. DEXA is approved for research in USA.

DEXA Equipment: Hologic QDR (1988) –Uses alternately pulsed x-ray beams. Lunar DPX (1990) –Sends rays from beneath person and measures energy sent through them. Norland XR (1993) –Uses dynamic filtration which adjusts to patient thickness.

DEXA Summary There is general agreement that some of the new DEXA software programs offer precise measurement of body composition. With additional studies, it is very possible that DEXA may become the new “gold” standard of body fat assessment.

DEXA Summary However, more validation studies are needed to determine the affect of various conditions such as hydration levels and disease state.

Imaging Techniques New technologies have allowed researchers to measure body composition in ways that were once impossible: –Computer assisted tomography (CAT scan) –Magnetic resonance imaging (MRI)

Computer Assisted Tomography A radiological technique that is commonly used for diagnostic purposes. Cross sectional areas of adipose tissue, muscle and bone can be measured with CT scans at any body site.

Computer Assisted Tomography Basic Principles: An x-ray tube and detectors are located at opposite poles of a large ring. Tube rotates around the table Subject lies with arm stretched above their head. Computer generates image from attenuated beams to recognize tissues.

Computer Assisted Tomography Precision: Adipose tissue from CT correlated high (r = 0.98) with chemically extracted lipid mass in rats. Difference between measurements of total AT volume is about 0.6%.

Computed Tomography and BC CT is an accurate technique for the assessment of body composition, and it does not rely on assumptions such as the constancy of either the density or the water content of fat free mass.

Computed Tomography and BC The most important application of CT in the field of body composition has been to the measurement of abdominal VAT.

Magnetic Resonance Imaging Based on the interaction between nuclei (proton) of hydrogen atoms and the magnetic fields generated and controlled by the instrumentation of the MRI system.

MRI The MRI field strength is 10,000 times stronger than that of earth. Protons tend to align with the magnetic field. A pulsed radio frequency (RF) field is applied to body tissues causing protons to absorb energy.

MRI RF field is turned off, protons return to original position and release energy absorbed.

MRI MRI data acquisition is programmed to take advantage of specific proton density and relaxation times (rate at which absorbed energy is released) to contrast between AT and skeletal muscle.

MRI Limitations: Time required to obtain quality images approximately 8 minutes for the abdominal region. Motion caused by respiration and cardiac function decrease image quality.

MRI Accuracy Only one report compared MRI measurements of AT with those derived by dissection of human cadavers. Found mean of 6% difference in VAT of 3 cadavers.

MRI and BC Because multiple images can be obtained without any known health risks to the subject, MRI is well suited for assessment of whole body AT distribution.

MRI and BC There have been several groups using a multi-slice protocol to evaluate whole body AT distribution.

MRI and BC MRI is useful for discrimination between VAT and SAT accumulation.

MRI and Whole-Body Lean Tissue Whole body lean tissue from MRI in obese men and women can be predicted with an accuracy of 3.6% and 6.5% respectively.

Summary Need for further validation of CT and MRI. Tools of choice for precise measurements of SAT and VAT VAT assessment is critical in assessment of health risks.