UTILIZATION OF VISIBILITY MONITORING FOR FIRE DETECTION.

Slides:



Advertisements
Similar presentations
Linear Heat Detection From Cables Britain Limited Unit 6 Waterfall Lane Trading Estate Waterfall Lane, Cradley Heath Warley, West Midlands Tel:
Advertisements

14-4 Rev. A Sept. 18, 2007 Fire Detection System Model S64F Helicopter.
Open-Path Gas Detection - Philosophy of Use or The Story of Clouds.
Drive in Rain.
Aspirated Smoke Detection
HX-40/40AM 3.0m high mount outdoor detector HX-40: standard model HX-40AM: HX-40 with active IR anti-masking model confidential.
E VERY L IFE H AS A P URPOSE… Flame Detection Theory.
BRE Energy Efficient Office of the Future
Smart Sensor Technology For Rail Network health Hawk Measurement Systems.
Flame photometry.
High Sensitivity External Leak Detection for Liquid Fuel Pipelines David Parman P.Eng. Ken McCoy.
Smart Sensor Technology for Gas Pipeline Monitoring
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
1 ASPIRATING SYSTEMS TRAINING e-series. 2 Overview e-series model range ASD Software  NetTracer  Detector Monitor  PipeTracer.
Monitoring Vibration on Tunnel Fans Safety First The worlds developing infrastructure creates many technical challenges for engineering and construction.
Properties of Multilayer Optics An Investigation of Methods of Polarization Analysis for the ICS Experiment at UCLA 8/4/04 Oliver Williams.
Fuzzy Logic in Traffic Control State Trafic Departement Baden Württemberg realized by INFORM Software Corporation Martin Pozybill Martin Pozybill Bernhard.
Electromagnetic Flowmeter Why use flow meters What is a magnetic flow meter – How do they work – How are the different from other meters Items that will.
Gas Sensor and Transmitter
1 INTRUSION ALARM TECHNOLOGY DETECTION DEVICES. 2 INTRUSION ALARM TECHNOLOGY Detection devices can be either passive or active. Passive devices typically.
Security Devices A modern security system, with its array of electronic components, is designed to sense, decide, and act. The security system senses events.
Test Methods and Apparatus for a Video-based System for Cargo Fire Verification I. Willms, W. Krüll, J. Shirer 1 Fourth Triennial International Fire and.
Iris Range : «Unconventional» conventional detectors.
Lease Automatic Custody Transfer
SB-N : Technical Workshop 1. General Presentation QUICK and EASY settings Alignment feedback Buzzer and Leds indication One person to set-up the columns.
Benefit and advantages using Iris conventional detectors range.
ANALYSERS & INSTRUMENTS DEPT. TUNNEL ROAD APPLICATION. I. -
VIKING Workshop – Hamburg, DE, March 2007 Best Practices in Monitoring Deployment, Hamburg, Germany Innovation in Monitoring VIKING Workshop “Best.
JAMIE LEE YI FEI HE XUE QI TO KAR YEE CHIENG LEE EN TAN YEE HERN BUILDING SERVICES 2.
Towards the Enhancement of Aircraft Cargo Compartment Fire Detection System Certification using Smoke Transport Modeling Walt Gill and Jill Suo-Anttila.
THE Reference in Traffic Video Detection Benjamin Schiereck, Sales Manger Traficon Germany Improving road and tunnel safety via incident management: implementing.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
High Sensitivity Smoke Detection
Atrium Fire Protection
Laser- based smoke detectors
Buildings and Structures 2 Fire Detection Systems.
1 Update on ELift™ SAGD artificial lift Presentation to Artificial Lift & Low-Pressure SAGD Subcommittees Nov 2004 Ken Kisman Ph.D., P.Eng.
MOCT(Magneto Optic Current Transduser)
Properties of Water Light Sound Temperature Density.
1 Intelligent Lighting Solutions for Professionals.
John Osborne : GS-SEM Civil Engineering 19 May 2009 Report on behalf of CLIC Civil Engineering and Services (CES) WG CTC 19 May 2009 Tunnel Cross Section.
FDS5 Simulation Results for VESDA Performance in HKCEC 2MW Fire Test (For internal info only) AEG, Xtralis Jan
All information contained herein is confidential and may not be disclosed to any third party without the written consent of SLC Europe & Africa More Than.
ARM Based Gas Leakage Detection System Student Name USN NO Guide Name H.O.D Name Name Of The College & Dept.
Small Telco Facility Protection Small, business-critical spaces where business interruption cannot be tolerated.
Comparison of OFIL’s Corona Camera & Ultrasonic instruments.
1 MORINFORMSYSTEMA-AGAT CONCERNMERIDIAN RPF
MODULE: 5 SALVAGE, OVERHAUL, AND SUPPORT ACTIVITIES.
TOWARDS A TEST METHOD FOR HYDROGEN SENSOR PERFORMANCE NATHAN D. MARSH AND THOMAS G. CLEARY Fire Research Division, National Institute of Standards and.
 There are 70,000 fires each year in Canada  Preventing fires will lessen the chance of injury or death  Knowing what to do in case of fire can save.
A Seminar Report On PRESENTED BY- GUIDED BY- INTRODUCTION The Availability of more & more powerful and less expensive micro-electronic devices for the.
Flame & Smoke Detection System Flame & Smoke Vision Detection is an intelligent vision-based analytics system which can timely detect suspicious fire or.
MONTGOMERY COUNTY FIRE & RESCUE
Kessler-Ellis Products
ATMOSPHERIC EFFECTS ON ELECTRO-OPTICAL SENSORS AND SYSTEMS
HX-40/40AM 3.0m high mount outdoor detector HX-40: standard model
Development of a GLE Alarm System Based Upon Neutron Monitors
Steam Generation In any industrial process, large quantities of steam are consumed. If natural gas is used to heat the boiler water it is often advisable.
How SCADA Systems Work?.
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
Sight Distances.
Smokes toxicity & opacity
ANALYSERS & INSTRUMENTS DEPT. OPASTOP GP2001H
Welcome To the world of Exquisite Heat
Smokes extraction principle
Future Vehicle-Based Alcohol Detection Systems
WELCOME.
NFMT Quick Fire Presentation: Solving Your Peace of Mind Problem Presenter: Cam Rogers Director of International & Western US Sales June 12, 2019.
Presentation transcript:

UTILIZATION OF VISIBILITY MONITORING FOR FIRE DETECTION

BASICS OF VISIBILITY MONITORING Continuous measurement of visibility and CO-concentration has been used for ventilation control in road tunnels for almost 40 years

 Visibility is measured in units expressing the extinction of light over a certain distance, E/m (extinction per meter) or, more convenient, mE/m (milli- extinction per meter)  1 mE/m means the light intensity is reduced by a factor of 10 over a distance of 1000 meters BASICS OF VISIBILITY MONITORING: UNIT

BASICS OF VISIBILITY MONITORING: TYPICALLY MEASURED VALUES & LIMITS Normal Traffic< 5 mE/m Heavy Traffic ~ 5 mE/m Traffic Jam ~ 7 mE/m Closing of the tunnel 12 mE/m Fire > 15 mE/m

VISIBILITY MONITORING AND FIRE DETECTION: WHAT IS MEASURED? Visibility measures:  In normal operation: Soot from exhaust fumes, wear debris from the tires, dirt particles, etc.  In case of a fire: Soot particles and other products produced by the fire  Fog / Water steam (not desired!)

 Fire sensor cables measure the temperature and react either above approx. 50°C or at a certain temperature gradient. In case of a fire, these conditions are only achieved in an advanced stage.  Visibility monitoring also detects cold smoke, typically produced in an early stage, or in case of a smoldering fire  Advantage visibility monitoring: it enables earlier warning! VISIBILITY MONITORING AND FIRE DETECTION: COMPARISON WITH FIRE SENSOR CABLES

 The visibility values increase quite quickly over 15 mE/m, however, this information was not used for fire detection  In the worst case, more fresh air is pumped into the tunnel by the ventilation system, based on the assumption that the emission is too high  Consequences: the fire gets more oxygen and the smoke is distributed in the tunnel VISIBILITY MONITORING AND FIRE DETECTION: EXPERIENCE FROM FIRE INCIDENTS

SMOKE DETECTOR FIREGUARD  Measuring principle: stray light  No moving parts  Response time: T90 in 5 second  Integrated temperature sensor  Fog elimination with heating elements (option)  Signal output via relays or Profibus DP  Installation on the wall, ceiling or in the intermediate ceiling of the fresh air channel

FIREGUARD INSTALLATION: WALL MOUNTING

FIREGUARD INSTALLATION: MOUNTING ON THE CEILING

FIREGUARD INSTALLATION: MOUNTING IN THE INTERMEDIATE CEILING

CONSEQUESCES FOR THE VISIBILITY MONITOR: INSTALLATION POINT  Where is the most ideal place for the system installation?

CONSEQUENSES FOR VISIBILITY MONITORING: INSTALLATION POINT  Smoke is normally concentrated under the ceiling  In-situ instruments are normally already mounted about 3 meters above the ground  Suction points for extractive instruments should also be mounted at the same height (currently they‘re about 1.5 meters above the ground)

mE/m 17:08: :08:4517:09:0017:09:1517:09:3017:09:4517:10: Relais VisGuard FireGuard Wand FireGuard Decke 1 (3m) FireGuard Decke 3 (3m) FireGuard Decke 4 (3m) Geräte Vortunnel Relais: 3: normal 2: Voralarm 1: Alarm 0: Störung CONSEQUENSES FOR VISIBILITY MONITORING: INSTALLATION POINT

CONSEQUESCES FOR THE VISIBILITY MONITOR: ALARM LEVEL  What signal levels can be expected during normal operation and in case of an incident?

CONSEQUESCES FOR THE VISIBILITY MONITOR: ALARM LEVEL

Zoom: after approx. 30 to 60 seconds, depending on the distance of the visibility monitor from the fire, a limit of 30 mE/m has been exceeded. At the same time it could be demonstrated, that 30 to 50 m/Em is a realistic threshold for a smoke alarm

FIREGUARD: FIELD TEST GOTTHARD Zoom: The instruments FireGuard ceiling 1 und FireGuard prototype (wall) give an alarm more or less simultaneously; the instruments FireGuard ceiling 3 (200m distance) and 4 (300m) react with a delay of 22 and 58 seconds, respectively.

FIREGUARD: FIELD TEST NORWAY The Norwegian Road Authority conducted a fire test in Norway (Runehamar) to compare the reaction and sensitivity of fire detection systems based on optical cables and stray light. The test demonstrated that both system detect fire quickly and reliably. However, stray light instruments detected the start of the car fire 2 ½ minutes earlier (because there was only smoke in the beginning)

FIREGUARD: FIELD TEST NORWAY Direct fire (untypical) of 1 MW: Immediate response of the sensor cable, followed by the FireGuard. Note: a competitive unit made a self-test during the start of the fire and missed it!

FIREGUARD: FIELD TEST NORWAY Direct fire (untypical) of 0.1 MW: Sensor cable and FireGuard give alarm at about the same time. However, the alarm level for the sensor cable is based on very small temperature changes, hence there’s a higher risk of a false alarm!

FIREGUARD: FIELD TEST NORWAY Car fire (realistic incident): FireGuard triggered alarm after approx. 40 sec. The sensor cable only after more than 3 minutes! This is because in the beginning there was only smoke (in 90% this is the case!)

FIREGUARD: FIELD TEST NORWAY Car fire (realistic incident): This graph shows now the temperature signal. The sensor cable reacted just a little bit before the temperature sensor which is built in the FireGuard.

 Visibility monitoring is now used not only for the ventilation control, but also for early fire detection  It allows to detect smoke and smoldering fires in an early stage  Real fires are typically detected 2 to 3 minutes ahead of fire sensor cables  For the installation, new requirements concerning the instrument density and mounting place have to be considered  Alarm levels for fire detection must be defined individually for each tunnel. VISIBILITY MONITORING IN ROAD TUNNELS: SUMMARY