MRI Safety for Clinical Coordinators

Slides:



Advertisements
Similar presentations
Door Guards Generally speaking … Know the building floor plan, what areas are public and what areas are not. Know the building floor plan, what areas.
Advertisements

BUILDING EMERGENCY ACTION PLAN
Fire and Environmental Safety Health, healing and hope.
EMERGENCY MEDICAL MANAGEMENT OF RADIATION CAUSALTIES IN HOSPITAL Module XVII.
Southwestern Oklahoma State University. Edwin Detweiler, MA, LAT, ATC, PTA Head Athletic Trainer Tammy Steinkraus, Med, LAT, ATC Assistant Athletic Trainer.
MRI Safety Training.
Garrett Park Elementary School Safety Information Meeting September 24, 2008.
1 A GUIDE TO LABORATORY SAFETY School of Engineering and Science February 2009 HEALTH, ENGINEERING AND SCIENCE.
When to put out a fire When to exit How to use a fire extinguisher Developed by Division of Occupational Safety and Health (DOSH) October, 2009 USING A.
YOUR GUIDE ON MRI.
RESEARCH MRI Safety Training
Always present at 21% in air Almost always present Electrical arcs, sparks, appliances, open flames When all three come together we have a fire.
Laser Awareness (Non-User). 2 What is a laser? Laser is an acronym for Light Amplification by Stimulated Emission of Radiation.
MRI Safety This slide show will educate all healthcare providers about the safe delivery of care in the magnetic resonance (MR) environment. This slide.
RESEARCH MRI Safety Training
STEM Room 305 Mrs. Barbour.
Heart or vascular Surgery at the Heart & Vascular Institute.
MRI Safety. Magnet Type  The MRI magnet used at MCH is the superconducting type. Superconducting magnets use a special wire which loses all resistance.
Vanderbilt University Medical Center Use either the arrows or the “Page Up” and “Page Down” buttons on your computer keyboard to move through the slides.
Transport Railways Incident Procedures. Aim To give students information about the emergency procedures to be adopted at incidents involving railways.
MRI Safety Jeopardy* ForcesProjectilesPotpourriHeatingScreening Because when you think MRI safety, think * Jeopardy is a trademark of Sony.
MRI Safety Jeopardy* EnteringMagnetsPotpourriMetalScreening Because when you think MRI safety, think * Jeopardy is a trademark of Sony Digital.
1 LASER SAFETY NSC Clinical and Operational Conference Calls August 24, 2005.
Overview The scanner Dangers in around the scanner In case of an emergency Emergency numbers Emergency procedure Reporting adverse events Safety checklists.
Health and Safety in the School of Biological Sciences This leaflet contains important health and safety information for new employees. If, after familiarising.
ONLINE SELF-STUDY Emergency Coordinator Annual Update.
Fire Prevention and Safety Health Science Class. Rationale: Fires may occur at any time, as a result of overloading wiring, smoking, improper chemical.
FIRE PREVENTION AND SAFETY PRACTICES Health Science.
Magnetic Resonance Imaging Mary Holleboom ENGR 302 May 7, 2002.
MRI General Safety Rules. GENERAL RULES DO NOT ENTER the MRI Scan Room if the door is closed. Always see the MRI Technologist before entering room. Always.
THE MAGNETIC FIELD IS AT FULL POWER ALWAYS …. IT IS ALWAYS “ON”.
Introduction This course is designed to inform individuals of the necessity of Magnetic Resonance Imaging (MRI) safety. Any individuals that are in contact.
MRI SAFETY FOR NON-MRI PERSONNEL.
MRI Safety Wendy Winkle
MRI Safety Course Module 1 –Patient Screening Learning Objective #1 The student will be able to describe in detail the patient screening process, contraindications.
Nuclear Magnetic Resonance Imaging By Blake Sharin.
For Medication Certified Staff Members Only.   Governs how we give medications in a school setting  States that each parish will develop, follow and.
Connecticut Technical High School System Exploratory Safety Program Safety Goals The Exploratory Safety Program will create an awareness of the need for.
1 The Karmanos Cancer Center’s ENVIRONMENT OF CARE 2009.
Engineering & Technology General Safety Rules
Uniting MRI with ULTRASOUND hhholdorf. Dr. Raymond Damadian The MRI scanner was invented by Raymond Damadian. Though, Damadian did not invent the actual.
The Physical Environment Tracers How Should I Prepare for the Physical Environment Tracers? Healthcare Engineering Consultants  Will limit.
Emergency Communication And Evacuation SOP# 505 Training On Demand.
MRI DRAFT Principles of MRI ► Sectional Anatomy ► Provides anatomic and physiologic info ► Non- invasive ► No radiation  Magnetic fields and.
MRI Safety Course Module 2- Emergency Situations.
Lab Safety The lab is an exciting place but it can be a dangerous place if the rules are not followed.
Magnet Safety.
CPR and First Aid Get out a piece of paper before the bell rings.
Unit 2: Fire Safety and Utility Controls
Lab Safety MYCAERT INC.. What is Safety? Safety is preventing injury and loss. Injury and loss may be inflicted on people or their property.
Spectrometer Solenoid Test Plan Workshop: Safety Considerations Steve Virostek - LBNL February 17, 2012.
NMR Safety Powerful magnets. NMR Safety 2 NMR Safety Information. UMBC Dept. of Chemistry and Biochemistry. Accessed 7 Jan 2014.
Magnetic Resonance Imaging (MRI) by Alex Kiss. Introduction 1946: MRI science was developed independently by Felix Bloch and Edward Purcell 1952: both.
Reference: Diversified Health Occupations. Required by many health care facilities To be worn when lifting or moving Effectiveness is controversial, reminds.
 This depends on a property of nuclei called spin.  Gyroscope: Principle: As long as its disc remains spinning rapidly the direction of the spin axis.
Electrical Work Practices City of Council Bluffs Presented by: SilverStone Group © 2012 Zywave, Inc. All rights reserved.
Emergency Actions Emergency Actions are composed of two actions. 1) Tornado & Severe Weather 2) Emergency Evacuation.
General Shop Safety Rules Safety in the Shop begins with the proper frame of mind. The expression: “Safety is no Accident,” is a good starting point.
Welcome At our best when it matters most. Observing Healthcare.
MRI Safety Awareness The purpose of this healthstream presentation is to educate the hospital staff that do not routinely come into the MRI environment.
Methodist Hospital for Surgery
Jody Culham Brain and Mind Institute Department of Psychology
Quick Planner Quick contact guide. Highland City Library Disaster and Emergency Plan Kellie Johnson 11/09/12.
DANGER Strong Magnetic and Radio-Frequency Fields Present
Fire Prevention and Safety
Magnetic field safety October 2018.
Basics of MRI By Dr. Mohamed Samieh.
Center for Magnetic Resonance Research
Hoglund Brain Imaging Center
College of Dental Medicine
Presentation transcript:

MRI Safety for Clinical Coordinators Wendy Winkle Indiana Institute for Biomedical Imaging Sciences (IIBIS) Department of Radiology Indiana University School of Medicine

What is MRI? MRI stands for Magnetic Resonance Imaging Magnetic field and radio waves are used to create detailed pictures of anatomy noninvasively Radio waves are directed at nuclei in this strong magnetic field. When the nuclei are excited then relaxed they emit a radio signal which can be measured and converted to an image. MRI does not expose subjects to ionizing radiation and DOES NOT require Radiation Safety Approval

Superconducting Magnet Magnetic field is generated with current in wires made of superconducting material No resistance at or near absolute zero Cooled with liquid helium and nitrogen Horizontal magnetic field = prone to missile effects

MR Safety Considerations The magnet is ALWAYS ON – even if we lose all electrical power in the building Main considerations to prevent injury People Equipment Other considerations to avoid inconvenience

Danger! High Magnetic Field Restricted Zone Research Institute II – Basement Level

Signs are posted outside of all MRI areas

Types of MRI The strength of the magnet is measured in Tesla (T) Common clinical MRI system field strengths are .3, .7, 1, 1.5 & 3T Open and Closed bore systems are available Open systems are good for large or claustrophobic patients, but commonly have lower field strength and image quality may suffer Closed systems are higher field strength and image quality is better in most cases

Types of MRI OPEN BORE MRI CLOSED BORE MRI -courtesy of Siemens (VIVA) -courtesy of Siemens (3T TIM Trio)

MRI of the Brain

People Precautions

Precautions for People Entering the Magnet Room People with a pacemaker or that have previously had a pacemaker should not go in the restricted area. People with implanted devices or prostheses should not enter the restricted area without physician clearance. Including but not limited to: Aneurysm clips, stents, cardiac defribillator Dental implants or devices Bone growth stimulators or orthopedic implants Implants for drug infusion or hearing

Precautions for People Entering the Magnet Room Pregnant Employees Women that are pregnant, or suspect that they may be pregnant, should not go in the restricted area during the first trimester. After the first trimester, they can go near the magnet but should not stay in the room during imaging procedures.

Object Related Precautions

Object Related Precautions Magnetic materials can become airborne projectiles and pose life threatening danger Small objects like paper clips, hair pins, jewelry, watches Scissors, pens, needles and other medical, support or surgical equipment Gas tanks and Cryogen dewers Facilities equipment (mops, floor buffers, tools, etc) Cellular phone, beepers, walky-talky

Avoid Inconvenience

Credit cards, ID cards, cellular phone etc Credit cards, ID cards, cellular phone etc. may not work after exposure to significant magnetic field. Do not take magnetic storage media, such as floppy disks, zip disks, magnetic tapes, laptops, etc. in the magnet room.

Magnet Quench

Magnet Quenching Quenching is the process whereby a magnet suddenly loses magnetic field. Instigated Quench Spontaneous Quench The magnetic field to blooms instantaneously. The superconductive coils become resistive and cause heating. Cryogens boil off! The helium and nitrogen from the magnet can replace oxygen in the room and cause asphyxia.

Magnet Quenching Cryogen vent Oxygen monitor Vents cryogens to the outside of the building Cryogen vents have failed Oxygen monitor The gas created when cryogens boil off is colorless and odorless Leave the area immediately If there is a smog in the area Oxygen monitor alarms

Instigated Magnet Quenching Quench button can discharge the magnet in about 20 seconds. Instigate a quench only when there is Life threatening situation -A person is pinned to the magnet by a large object that cannot be removed by hand. Large Fire – So that fire fighting personnel can safely enter the room.

Magnet Quenching Spontaneous or instigated quenching can cause severe or irreparable damage to the magnet coils and pose severe health risk Boiling off of cryogens can cause asphyxiation At least $50K to re-energize the magnet plus 1-2 month down time. ~$2M if the magnet is irreparable.

Quenched? A partially quenched horizontal bore NMR magnet. There is still enough field left to hold on to that gas tank, though! Photo Courtesy of William C. Stevens, Ph.D., NMR Facility Director, Southern Illinois University

Emergency Procedures

Life-threatening Emergency Person pinned to the magnet by large object Outbreak of Fire Quench

Person Pinned to Magnet Notify MR personnel immediately MR personnel will call for medical assistance MR personnel will try to remove the object pinning the person If the object cannot be removed All leave the restricted area Instigate quench

Outbreak of Fire Large Fires Small Fires Only professional fire fighters should attempt to extinguish. All staff should leave the building. Small Fires Can be controlled by a staff member with a first aid fire extinguisher. Must use non-ferromagnetic fire extinguisher and other equipment.

Spontaneous Quench Immediately leave the area! Call MR personnel from a safe zone

One cannot overemphasize safety around a MRI system

Safety Policies

MRI Safety Policies SUBJECT SAFETY Any patient with an implanted device must have a card that states the model #, manufacturer and contact # so our technologists can verify safety of the device prior to the patient entering the MRI Field Strength Specific Protocol and/or Scan Time Specific MR SAFETY QUESTIONNAIRE should be completed 24hrs prior to exam to allow time to verify safety before the subject arrives for the exam

MRI Safety Policies SUBJECT SAFETY Subjects answering negatively to questions on the MR SAFETY QUESTIONNAIRE may be excluded unless you have accounted for additional testing in your IRB Ex. Subject was a metal worker & has had metal in their eye in the past. Clinical patients would receive an x-ray to exclude safety concern; however, a research subject should be excluded unless you account for the possible x-ray radiation exposure in your IRB

MRI Safety Policies SUBJECT SAFETY Medical attention even in an emergency should be administered outside the magnet room! In the event a subject requires medical attention the MRI technologists will remove them from the magnet room on an MR compatible cart

MRI Safety Policies GENERAL An MR Safety Data Sheet must be completed by anyone entering the MR facility. Coordinators and other support staff are not allowed in the magnet room unless accompanied by MR personnel. There are exceptions to this rule if the staff undergo MR safety training and have permission of the facility director or their designee.

MRI Safety Policies GENERAL Always remove all items from your person, pockets and belt before entering MRI Tech or MR Physicist will test equipment and devices prior to taking them into the magnet room with a powerful handheld magnet Equipment and devices not certified MRI SAFE must be cleared by the Research MRI Safety Committee prior to study start

Website Offers Help! For assistance with regulatory risk wording visit the Office for Research Imaging website: www.ori.medicine.iu.edu

Into the Bore They Go! All images and information courtesy of Magmedix website: http://www.magmedix.com

An industrial floor polisher was taken into the MRI room by facilities personnel. Within seconds it was drawn into the bore of the magnet.

A pallet jack was located within the 5 Gauss line of the magnet A pallet jack was located within the 5 Gauss line of the magnet. Into the bore it went - You wouldn’t want to stand in the way of this!

This shows what can happen when a welding tank is brought near a magnet. The flying tank destroyed a phantom that was sitting in the bore.

Repairman injured in bizarre MRI machine accident A Houston repairman is hospitalized after a bizarre accident with an MRI machine. ABC13 Eyewitness News (2/12/03) — A repairman may have broken his arm in a freak accident where a piece of metal pinned him to an MRI machine. Cy-Fair volunteer firefighters were called to the Steeplechase Diagnostic Center after the magnetic force of the machine caught the repairman. Why? Because he carried a piece of steel into an imaging room. "The magnetic field will grab a hold of any steel objects, metal objects and the field is very strong," said business owner Lance Rickey. "So obviously, as what happened here tonight, he was pulled into the magnet and pinned there." Rescuers finally freed the repairman by releasing the magnets' cooling helium, breaking the machine's hold on the metal. The repairman was taken by LifeFlight to Memorial Hermann Hospital. Courtesy of ABCNews.com

Hospital Nightmare Courtesy of ABCNews.com Boy, 6, Killed in Freak MRI Accident July 31, 2002 — A 6-year-old boy died after undergoing an MRI exam at a New York-area hospital when the machine's powerful magnetic field jerked a metal oxygen tank across the room and into the magnet where the child was located. Employees of the Westchester Medical Center in Valhalla, N.Y., gather outside after learning of the deadly MRI incident. (ABCNEWS.com) Courtesy of ABCNews.com