“Reactive Power Management and Voltage Stability” Sharma Kolluri, IEEE Fellow Manager of Transmission Planning Entergy Services Inc Presentation at 2012.

Slides:



Advertisements
Similar presentations
“Power Factor” In Transmission System
Advertisements

Chapter 11 Inductors.
RES-E Impact on Transmission Grid and Power System Reserves
ECE 530 – Analysis Techniques for Large-Scale Electrical Systems
Chapter 12 RL Circuits.
Announcements Be reading Chapter 6. HW 3 is due now.
Arrowhead  Weston Transmission Line Project Dave Van House Minnesota Power.
Electronics Inductive Reactance Copyright © Texas Education Agency, All rights reserved.
“Importance of Reactive Power Management, Voltage Stability and FACTS Applications in today’s Operating Environment” Sharma Kolluri Manager of Transmission.
Dynamic VAR’s [D-VAR] What are D-VAR Devices? Dynamic VARs… Fully integrated modular STATCOM with proprietary 3X overload Instantaneously injects precise.
1 PS ERC Reactive Power and Voltage Control Peter W. Sauer Department of Electrical and Computer Engineering University of Illinois at Urbana-Champaign.
New Orleans, LA July 8, 2004 John Zemanek Vice President, Transmission Entergy Transmission Planning Summit.
Presented by: Bikram Choudhury Regd. No. : Department of Electrical And Electronics Engineering FACTS Devices For Smart Grid 2 July 2015.
Per Unit Representation Load Flow Analysis Power System Stability Power Factor Improvement Ashfaq Hussain.
Presentation to WECC TSS May 8, 2015
Storey: Electrical & Electronic Systems © Pearson Education Limited 2004 OHT 16.1 Power in AC Circuits  Introduction  Power in Resistive Components 
Power Factor and Power Factor Correction
Lesson 27 Power Factor Correction
LOGO LINEAR CIRCUIT ANALYSISSAJID HUSSAIN QAZI MEHRAN U.E.T, KHAIRPUR CAMPUS A.C POWERS AND POWER FACTOR.
EKT214 - ANALOG ELECTRONIC CIRCUIT II
Synchronous Generator
ET2105 Electrical Power System Essentials
Active and Reactive Power Control Praveen Jain 19 September 2014.
STATCOM The STATCOM (or SSC) is a shunt-connected reactive-power compensation device that is capable of generating and/ or absorbing reactive power and.
Indian Institute of Technology, Bombay
1 Voltage Stability and Reactive Power Planning Entergy Transmission Planning Summit New Orleans, LA July 8, 2004 Entergy Transmission Planning Summit.
Transmission planning in Vermont Past, present and future Docket 7081 workshop By Dean LaForest 9/19/05.
Year 2006 Report “Better” Managed and Controlled Transmission Grids using Advanced Technological Concepts Aty Edris EPRI Power Delivery & Markets
THE TRES AMIGAS SUPERSTATION Southwest Renewable Energy Conference Santa Fe, NMSeptember 16 th 2010 UNITING THE NATION’S ELECTRIC POWER GRID.
POWER FACTOR CORRECTION
Houston Area Dynamic Reactive Project March 11,
Voltage Collapse M. H. Sadeghi Winter 2007 KNTU. Power System Stability IEEE: Power system stability is defined as the capability of a system to maintain.
American Electric Power Service Corporation Jan 26, Coordinating Controls across CREZ  What dials are available to the operators?  What are the.
THYRISTOR BASED FACTS CONTROLLER
ECE 530 – Analysis Techniques for Large-Scale Electrical Systems
1 Mid-Continent Area Power Pool Wind Integration Studies Edward P. Weber August 16, 2007.
Review 1. Review of Phasors Goal of phasor analysis is to simplify the analysis of constant frequency ac systems: v(t) = V max cos(  t +  v ), i(t)
Power System Fundamentals EE-317 Lecture 3 06 October 2010.
LAREDO PLANT RMR EXIT STRATEGY Presentation to Board of Directors March 16, 2004 Transmission Services Operations.
1 ELECTRICAL TECHNOLOGY EET 103/4  Define and explain sine wave, frequency, amplitude, phase angle, complex number  Define, analyze and calculate impedance,
1 Stability Issues in Entergy System Entergy Transmission Planning Summit New Orleans, LA July 10, 2003.
UNIT-VII Static Series Compensators
TRANSMISSION CONSTRAINTS KENNETH A. DONOHOO, P.E. Manager of System Planning, Technical Operations
REACTIVE POWER COMPENSATION
Electrical Principles 1 1 G5 - ELECTRICAL PRINCIPLES [3 exam questions - 3 groups] G5A - Reactance; inductance; capacitance; impedance; impedance matching.
Voltage Control Brad Calhoun Consultant, Sr. Trainer Spring 2016.
Chapter 9 CAPACITOR.
SEMINAR PRESENATATION ON WIDEAREA BLACKOUT (AN ELECTRICAL DISASTER) BY:Madhusmita Mohanty Electrical Engineering 7TH Semester Regd No
EMERGING FACTS CONTROLLERS
 The common type of wind power generators are squirrel cage induction generator (SCIG),doubly fed induction generator (DFIG)  For more secure and.
Power in AC Circuits Introduction Power in Resistive Components
A Project Review On POWER QUALITY IMPROVEMENT IN GRID USING STATECOM
FACTS BY SVC, FLEXIBLE AC TRANSMISSION
Overview of Flexible AC Transmission Systems
SIMULATION AND IMPLEMENTATION OF FC-TCR
IG BASED WINDFARMS USING STATCOM
Unified Power Flow Controller (UPFC)
Series Connected Controllers
Introduction To Reactive Power
Series Capacitor Compensation
Power in AC Circuits Introduction Power in Resistive Components
POWER SYSTEM ANALYSIS INTRODUCTION.
DEC System Voltage Planning - June 2018
Mid-Continent Area Power Pool
Protective Relaying Conference
Unified Power Flow Controller (UPFC)
ELL100: INTRODUCTION TO ELECTRICAL ENGG.
Palo Verde-COI RAS Retirement
FACTS BY SVC, FLEXIBLE AC TRANSMISSION
Palo Verde-COI RAS Retirement
Presentation transcript:

“Reactive Power Management and Voltage Stability” Sharma Kolluri, IEEE Fellow Manager of Transmission Planning Entergy Services Inc Presentation at 2012 Southeast Symposium on Contemporary Engineering Topics (SSCET) October 26, 2012 New Orleans, Louisiana

Outline Background/Introduction VAR Basics Voltage Stability FIDVR Technology Summary.

List of recent blackouts 1.NE blackout - August 14, Greece – July 12, Florida – February 26, Southeast Power Outage/San Diego – September 8, India – July 31, 2012.

Recommendation#23 Strengthen Reactive Power and Control Practices in all NERC Regions “Reactive power problem was a significant factor in the August 14 outage, and they were also important elements in the several of the earlier outages” -Quote form the outage report

Reactive Power Basics Reactive Power Basics

Laws of Reactive Physics Complex Power called Volt Amperes (“VA”) is comprised of resistive current I R and reactive current I Q times the voltage. –“VA” = VI T * = V (I R – jI Q ) = P + jQ Power Factor (“PF”) = Cosine of angle between P and “VA” –P = “VA” times “PF” System Losses –P loss = I T 2 R (Watts) –Q loss = I T 2 X (VARs) VA P Q North American Electric Reliability Corporation

Reactive Physics – VAR loss Every component with reactance, X: VAR loss = I T 2 X Z is comprised of resistance R and reactance X –On 138kV lines, X = 2 to 5 times larger than R. –One 230kV lines, X = 5 to 10 times larger than R. –On 500kV lines, X = 25 times larger than R. –R decreases when conductor diameter increases. X increases as the required geometry of phase to phase spacing increases. VAR loss –Increases in proportion to the square of the total current. –Is approximately 2 to 25 times larger than Watt loss. North American Electric Reliability Corporation

Transmission Line Real and Reactive Power Losses vs. Line Loading Source: B. Kirby and E. Hirst 1997, Ancillary-Service Details: Voltage Control, ORNL/CON-453, Oak Ridge National Laboratory, Oak Ridge, Tenn., December 1997.

Static and Dynamic VAR Support Static Reactive Power Devices –Cannot quickly change the reactive power level as long as the voltage level remains constant. –Reactive power production level drops when the voltage level drops. –Examples include capacitors and inductors. Dynamic Reactive Power Devices –Can quickly change the MVAR level independent of the voltage level. –Reactive power production level increases when the voltage level drops. –Examples include static VAR compensators (SVC), synchronous condensers, and generators.

Reactive Power Management Effectively balancing capacitive and inductive components of a power system to provide sufficient voltage support. Essential for reliable power system operation. –Prevention of voltage collapse Benefits Improves efficiency of power delivery. Improves utilization of transmission assets. Reduces congestion and increases power transfer capability. Enhances grid security.

Reactive Power for Voltage Support Reactive Loads VARs flow from High voltage to Low voltage; import of VARs indicate reactive power deficit

Voltage Stability Voltage Stability

What is Voltage Instability/Collapse? A power system undergoes voltage collapse if post-disturbance voltages are below “acceptable limits” voltage collapse may be due to voltage or angular instability Main factor causing voltage instability is the inability of the power systems to “maintain a proper balance of reactive power and voltage control”

Voltage Instability/Collapse The driving force for voltage instability is usually the load. The possible outcome of voltage instability: –loss of loads –loss of integrity of the power system Voltage stability timeframe: –transient voltage instability: 0 to 10 secs –long-term voltage stability: 1 – 10 mins

Key Concerns Minimize motor tripping Limit UVLS activation Voltage (pu)

P-V Curve

Q-V Curve

Voltages at Goslin 138kV Station Time (seconds) Voltage (volts)

Common Solutions for Voltage Instability Install/Operate Shunt Capacitor/Reactor Banks Add dynamic Shunt Compensation in the form of SVC/STATCOM/DVAR to mitigate transient voltage dips Add Series Compensation on transmission lines in the problem area Construct transmission facilities Coordinate Voltage Schedules/Reactive Power Flows Implement UVLS Scheme

Fault Induced Delayed Voltage Recovery (FIDVR)

What is it? –After a fault has cleared, the voltage stays at low levels (below 80%) for several seconds Results in dropping load / generation or fast voltage collapse 4 key factors drive FIDVR: Fault Duration Fault Location High load level with high induction motor load penetration Unfavorable Generation Pattern

A “Near” Fast Voltage Collapse in Phoenix in 1995 North American Electric Reliability Council, System Disturbances, Review of Selected 1995 Electric System Disturbances in North America, March 1996.

Technology for Addressing Reactive Power/Voltage Stability Problems Technology for Addressing Reactive Power/Voltage Stability Problems

Porter SVC

Porter Static Var Compensator (SVC) Maintains system voltage by continuously varying VAR output to meet system demands. Controls capacitor banks on the transmission system to match reactive power output to the load requirements.

Series Capacitor – Dayton Bulk 230kV Station The Capacitor offsets reactance in the line, making it appear to the system to be half of its actual length. Power flows are redirected over this larger line, unloading parallel lines and increasing transfer capability.

Static compensator (STATCOM) Voltage source converter device Alternating voltage source behind a coupling reactance Can be operated at its full output current even at very low voltages Depending upon manufacturer's design, STATCOMs may have increased transient rating both in inductive as well as capacitive mode of operation Transformer DC-AC switching converter I X System bus CsCs V dc V E Schematic diagram of STATCOM

Natchez DVAR

Summary The increasing need to operate the transmission system at its maximum safe transfer limit has become a primary concern at most utilities Reactive power supply or VAR management is an important ingredient in maintaining healthy power system voltages and facilitating power transfers Inadequate reactive power supply was a major factor in most of the recent blackouts

Questions?