Product and Accessories

Slides:



Advertisements
Similar presentations
The next generation of VITODENS 200
Advertisements

TECHNICAL QUIETSIDE DPW Dual Purpose Water Heating Season 2008/2009
Energy Efficient Steam Systems
VF™ Series Boiler.
Customer Service – International dept. STAR 24 3 E.
Sizing, Installation November 2008
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
“Enerpak” Units » Propeller Type Fan » Size 100 – 400 MBH » 80% Thermal Efficiency » Natural or LP Gas » 10 Year Warranty on Heat Exchanger, Burners,
Unit 206: Domestic hot water systems
AQ2511B0 Boiler Reset Panel – for Whole House Heating Control – Immediate Retrofit Opportunity !
Basic Refrigeration Cycle
Cold feed to hot water cylinder Sink Basin Bath Drain valve Stop valve WC cistern 100 litre (minimum storage cistern)
HIGH EFFICIENCY WATER HEATERS - Residential Gas - Polaris ®
1 Direct Fired Gas Heating Presented by Jim Jagers of Applied Air.
A Fundamental Review of Solar Thermal Systems Installation, Sizing and Benefits of a Bradford White Solar Thermal Water Heater Bradford White Solar Thermal.
Chapter 9: Water Heating To be used with the Guide to Building Energy Efficient Homes in Kentucky.
Ground Loop Design. Heat Sources Horizontal ground loops  Collector pipework laid horizontally  Requires large land area  Cost.
Air-Conditioning Control Systems
Unit 206: Domestic hot water systems
S8910U1000 Universal Electronic Ignition Modules Training Module
Unit 208: Central heating systems
Mechatronics Final Project Alfonso Cozzo Vinay K.M Xin Wan.
Customer Service VICTRIX 90 Central heating only, wall hung condensing boiler.
DIVATOP 60 New Wall Hung Gas Fired Boiler. Divatop 60: Main Features Leader in wall hung boilers Ferroli Ferroli, in line with its position as a comfort.
Presented by: Terry Stohs Viessmann Manufacturing Company Inc.
Engineer Presentation
Dakota Nickerson, Kyle Pflueger, Adam Leschber, Andrew Dahlke M.E. Undergrad 1.
Harnessing Free Heat. The Energy Harness provides hot water using multiple heat sources, making the best use of low grade heat. It improves the efficiency.
Unit 206: Domestic hot water systems
© 2012 Rinnai America Corporation Rinnai Circ-Logic (RCL)
Product Introduction.
VHP, Rammensee, Subject to changes. Errors excepted, status: July 2005 ID1 Abbreviations for integration diagrams 1.Heat pump 6.Passive cool production.
STEAM HEATING.
Hydronic Mechanical Controls
Gas Furnace Planned Maintenance
© 2011 Rinnai America Corporation TANKLESS WATER HEATING TECHNOLOGY For Commercial.
HVAC523 Circulator Pumps.
HVAC523 Basic Subsystems.
HYDRONIC HEATING AQUASTATS
Presentation on Feed and Expansion Cistern. Central Heating At the end of this part you should be able to: Identify general system methods of feed and.
Zoning Hydronic Systems. Zone Control Divides the Space to be Heated 1.Each with its own heating needs and control systems 2.There are several reasons.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
RELIABILITY ON DEMAND INTRODUCING A COMPLETE LINE OF TANKLESS GAS WATER HEATERS.
Product Introduction January 2009
Simplicity Series The 1st Fuel-Convertible Concentric Vent
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
I Need A Space Heating System Let’s Look At A Central Steam Plant Option.
4.0 Equipment Installation Aspects (Section 4.5 On-Rate for Fuel-Fired Equipment)
We apply 120 VAC to the HM Unit (Remember to check polarity!) Our primary step down T/X provides power to terminal “X” and “COM” on the ignition control.
Boiler Energy Saver Advanced Boiler Controls. Most boiler controls at present consist of a switch!
Purgers and Non-condensables “What are they and why should I care?” Refrigerating Specialties Division Parker Hannifin Corporation July 2004.
Instant hot water. Long-term savings.
Fan Coil Controller FC/S 1.1
Unit 13 Oil-Burning Equipment
Unit 7 Gas Heat: Natural and LP
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
GEYSER Heat Pump Water Heater
Hot water Systems Heaters.
Hot Water Systems Cylinders and Systems.
XP PLUS Intro High Efficiency Circulating Water Heater
Universal Interrupted Electronic Oil Primary R7184U Training Module
Domestic Hot Water Recirculation
Domestic Hot Water Recirculation
Presentation transcript:

Product and Accessories Quietside DPW Unit Product and Accessories Heating Season Jan 2009 QUI-DPWBP-002

Who is Quietside? With two locations, on opposite coasts West Coast location is in Santa Fe Springs CA East Coast location is in Carlisle PA Third location in the Dallas/Fort Worth area opening 2008 Quietside distributes these products, plus Samsung Mini Splits, Quietside Mini Splits from these locations

Who is Quietside? Both locations provide Customer service and shipping but most importantly : Full Technical Support and Training is available in both locations Both locations have bespoke classrooms and hands on training laboratories

What is a Dual Purpose Water Heater A Dual Purpose Water Heater is a unit that will provide both heating water for space heating and also potable domestic hot water for washing from a single unit without any additional controls required Domestic hot water is given priority over the space heating, and is activated by flow through the domestic hot water system DHW is “on demand” and continuous, it will be provided as long as the faucet is open Once DHW call is completed the unit will revert to heating the house as required

What is a Dual Purpose Water Heater It is not called a Boiler in North America unlike the rest of the world, this is because It does not provide closed loop heating water at a temperature above 176 DegF It does not have an ASME H stamp, therefore cannot be used in areas where this is a requirement Internal Water Volume is less than 1 gallon Therefore these units are certified by ANSI Z21.10.3-2004/CSA 4.3-2004 as a gas water heater

Who makes this unit? DAESUNG CELTIC is a Korean Gas boiler manufacturer established in 1982 Joint investment agreement with Chaffoteaux et Maury Annually they produce and supply over 150,000 gas boiler products to Korea and world wide market. Currently selling product to North America, China, Russia, and several CIS countries

The Manufacturer Annual Volume 150,000 units ISO 9001, ISO 14001, Six Sigma certified for quality Cell Manufacturing as pioneered by Toyota All units are fully tested before packaging and shipping

DPW NG/LP Wall Mount DPWH 2 Models DPW-099A 99,000 Btu/h Max Input DPW-120A 120,000 Btu/h Max Input All units are 90% AFUE and Energy Star certified All units qualify at a 0.83+ EF for the IRS $300 rebate in the US

DPW Model Features All units are fully modulating in capacity DPW-099 Range 47,800 – 99,000 Btu/h DPW-120 Range 47,800 – 120,000 Btu/h Closed loop heating water temperature range 122-176 DegF DHW temperature setting 98-114 DegF, 120, 130 and 140 DegF

DPW Model Features Wet recuperative HX manufactured from Aluminum Alloy Removes latent heat from the flue gas to increase efficiency By product is condensate, which is drained away from the unit via the condensate siphon Condensate is slightly acidic – PH level 5

DPW Model Features Exhaust and Inlet vent connections for 3” diameter Schedule 40 PVC Flue gas temperature, max 136 DegF Max flue length 45ft equivalent, max 3 elbows Vent termination included

DPW Model Features Components included include Primary loop circulator provides flow for either the Primary loop or close coupled AHU Closed loop expansion tank – similar in size to a 20 gallon normal expansion tank

DPW Model Features Flow switch on DHW cold inlet connection detects flow in the DHW system > 0.7 GPM 3 Way valve energizes to direct heating loop flow through DHW HX Unit fires to provide DHW at temperature selected until call is completed Temperature sensor on DHW outlet measures water temperature – unit will modulate to maintain temperature

DPW Model Features Microprocessor control provides accurate control of heating water temperature and all other operational and safety features of the unit Dip switches can be used to set up unit for various option 3Amp fuses protect unit

DPW Model Features Unit controller included Sets heating loop water temperature from 122 – 176DegF Sets DHW temperature 98 – 114 DegF, 120, 130 or 140 DegF Displays room temperature but is not a thermostat Shows error codes and unit operation status

DPW Model Features Simple Zone wiring Two wires are used to connect to an X – X or dry contact (zero voltage) on zone controller or switching relay Once contact is closed unit will fire and provide heating loop water at temperature selected on controller Zone wires

DPW Model Features Self Diagnostic 13 Specific error codes are displayed in the event of a fault occurring Range from condensate overflow to overheat to low water level

DPW Model Features Built in closed loop strainer, located on return connection to the unit Built in Air eliminator for the closed loop system – HOWEVER always install an additional high quality air vent – Spirotherm at highest point in the system

DPW Model Features Modulating gas Valve This allows turn down of capacity over 50% dependant on load in the systems Spark ignition and rectification flame detection saves energy and provides safety should the unit not ignite

DPW Accessories DHW Tank – Storage tank to provide additional DHW performance for high DHW water demand applications Buffer tank – Prevents short cycling of the heating system LP Conversion kits to allow the unit to be field converted to LP gas supply

DPW + DHW Storage Tank Specifically designed for use with DPW Available in a 20 Gallon Size Combines the continuous use of an On Demand DHW supply with the flow rate and instant hot water of a tank, allows for use of Jacuzzi tubs etc Design allows tank to be completely depleted for a tub, but still provides hot water if a shower is taken immediately after

DHW Storage Tank Supplied with for field installation Taco 008 Pump Assembly with internal flow check Mixing Valve Pressure Relief Valve Tank Drain Aquastat to control tank temperature

DPW & TC-001 Conversion kit for gas/electric tank water heaters All component parts needed to turn them into a QSDHS system including Mixing Valve Bronze pump with integral flow check

DPW & Buffer Tank 20 Gallon Buffer Tank Used to prevent short cycling of the unit during mild temperature operation or if smaller zones than 20,000 Btu/h heat loss are used Complete with all ports required and an aqua stat to provide a control input for the DPW, and maintain the set tank temp

DPW & LP LP Kit for field conversion Unit specific, changes Nozzle assembly Will require use of a manometer to adjust gas pressures to correct settings

DPW Warranty Standard Warranty Heat Exchangers 12 Years All other Parts 5 Years

Literature Available DPW Sales Brochure Submittal Basic Application Guide including a detailed Troubleshooting Guide Piping and Wiring Diagrams for various applications DPW IOM Website : www.quietside.com

Support Available Sales Support Local Representation Quietside sales staff Regionalized Customer Support Technical Support East Coast 717 243 2535 West Coast 562 699 6066 Website : www.quietside.com