Pa-9 Power Analyzer V 1.0 1/14/2000. 2 OBJECTIVES  Use The Latest Technology To Deliver Highest Performance At Lowest Cost.  One of the most powerful.

Slides:



Advertisements
Similar presentations
HARDWARE Rashedul Hasan..
Advertisements

Installation base of over 25,000 valued installations, Country wide Installation base of over 25,000 valued installations, Country wide Recognised as.
Beckett Energy Systems
Load Management System
Multi Functional Digital Fault Recorder
THS3000 Product Introduction Market Dynamics  Customers require more flexible solutions  Many test solutions are driven by both measurement needs.
Multi-DNC Data Collection/Monitoring
MDR-304 Digital Video Recorder. Can do: - Reliable real time recording of vehicle interiors & surrounding road environment. - Removable recorder unit.
ACR Systems Inc. ISO 9001 Registered World Class Data Loggers.
LP33 Series UPS kVA 400Vac/CE
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
Make the most of your energy Looking for accurate electric energy metering and simple, easy installation? PowerLogic ® Energy Meter December 2008 Energy.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
G GE Power Management MMII Intelligent MCC Controller.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
DCRK DIGITAL POWER FACTOR CONTROLLERS
CheckSystem 2.1 Portable Test Systems Page 1 April 2011.
1 QED In Vivo USB Input Output Box configuration This tutorial contains a number of instructions embedded in a great deal of explanation. Procedures that.
Presented to: Name of Customer Enhanced MET ONE 3400 Series Portable Airborne Particle Counters.
CALPORT 300 Three-Phase Portable Reference Standard
ZTE Series Automatic Transfer Switches (ATS)
/1 Testing Harmonics and Flicker /1 Harmonics & Flicker Two different test standards: EN & EN EN controls.
G650 Generator Protection & Control System
1 Welcome To the AVO International Meter Adapter Recorder Presentation This Presentation will Take about 15 Minutes Click the Right Arrow Button or Press.
Looking for a more powerful circuit monitor?
TPS2000 Series Oscilloscopes Powerful productivity from bench to field Features Featuring:  100 MHz and 200 MHz models  2 or 4 isolated analog channels.
FG Wilson Access 4000 Control Panel
Jan. 1, PM7000 John Outram Outram Research Ltd Exclusive in Ohio By:
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
PPS 3.3 C Portable Power Source Page 1 January 2011.
Portable Working Standard and Power Quality Analyzer
Features: Easy to use data collector 2 channels simultaneous sampling & display On-site 400-lines FFT spectrum and waveform display; Transfer function.
STYLITIS-POWER …designed for in‐coming and out‐coming power/energy analysis.
Self Guided Tour of TagMate™QC Display Tag DATA Tag Data: PRINT TagMate™QC SETUP Display STATS Tags: START and READ SEND All Data to PC Additional Capabilities.
All rights reserved, property and © CAD Computer GmbH & Co.KG 2009 Cover page.
All rights reserved, property and © CAD Computer GmbH & Co.KG 2009 Cover page.
VR1710 Voltage Quality Recorder Fluke Confidential 1 VR1710 Voltage Quality Recorder The Fluke VR1710 is a single- phase, plug-in voltage quality recorder.
Power Probe The PSP Power Probe is a three phase data logger, quality of supply monitor, and remote terminal unit for demand-side- management. Historical.
IQ Analyzer 6400/6600 Series Cutler-Hammer Power Management Products High End Metering Capabilities.
TDSPWR2 Power Measurement and Analysis Software Addressing Today’s Challenges.
© 2007 Ideal Industries 1 of 32 Intro To Ideal 800 Power Analyzer Basics of IDEAL Industries 800 Series Power Analyzer.
PTS 2.3 C Portable Test System Page 1 March 2009.
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
Velleman Oscilloscope: Windows 7 by Mr. David Fritz.
SmartMQn Motor Horner APG, LLC September 9, 2008.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
Make the most of your energy December 2008 HDM Accurate measurement and electrical utility cost allocation for multi-tenants PowerLogic ® High Density.
Digital Literacy: Computer Basics
LP Series 400V CE GE Consumer & Industrial September 2004.
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
Digital Multimeter – Basic Guide
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
DIGITAL MULTIMETER DMG
Power Quality at Solar Distributed Generation Facilities
Technology that lets you Trust your batteries!
Portable Working Standard
PTS 3.3 C Portable Test System.
SCADA for Remote Industrial Plant
Powerful Performance from Bench to Field
Cover page.
PQube vs. X (instrument from competitors)
Series 5300 Lithium Cell Formation System
PowerLogic™ offer for the basic metering market
PM9, PM9P and PM9C Power Meter
Simple, accurate tenant sub-metering
Power monitoring software
Presentation transcript:

Pa-9 Power Analyzer V 1.0 1/14/2000

2 OBJECTIVES  Use The Latest Technology To Deliver Highest Performance At Lowest Cost.  One of the most powerful DSP’s.  Co-microprocessor.  Low Cost Digital Camera Hi-Density Memory.  Low Cost/High Performance Graphical Display.  Delay Obsolescence.  Worldwide Product.

3 Result: pa-9 Power Analyzer  Evolved from:  15 + Years Experience With Utilities Monitoring And Power Quality Measurement Needs  Listening To Suggestions From Our 600+ Customers and Experience From Our Very Successful Products like the pa-7 Power Analyzer (1600 units installed).  Our Goal:  Extend To The Industrial Market Our Reputation Earned Through 15 Years of Service/Reliability To The Utility Market.

4 Light Rugged polypropylene Case (12.5lbs or 5.7Kg) Lockable Hasps 5 Current Channels Optional Auxiliary AC Power Input (90-600vac/dc) 4 Voltage Channels Optional External RS232 Port Optional Modem

5 KEY FEATURES Simplified Instruction Sheet Home Key Backlit Graphic Display Mouse Type Navigation System DB9 RS232 Port Real Time Display Key

6 KEY FEATURES  4 V (Differential)/5 Current Channels  Range: Voltage 600V AC or DC Current Based on CT  Most Configurations Supported for Power Measurements  Immediate Local Info on Graphical Display  Powered from Phase A Voltage (90-600v AC,or v DC)  FLASH PROM & Non-Volatile Data Memory  256/Cycle Sample Rate (TRMS through 63 rd Harmonic)  Memory Up to 12 MB And Data Transfer Up to 115KB  Sub-Cycle Event Capture to 65 Microsecond Events  3 Packages – Portable, Wall Mount, Rack Mount

7 KEY FEATURES  4 Simultaneous Recordings  RMS (Long Term Trend)  Out of Limits Log (for RMS Value)  Waveform  Power Flow Parameters

8 RMS Recording  Parameters to consider  Sample Rate (Fixed at 256/cycle)  Response Time (or Integration Time) User Settable To 1 cycle or longer. Cycle by Cycle Recording Possible.  Storage Interval User Settable 1 To cycle 4 Hours. Save Min RMS, Max RMS, Overall RMS per Storage Interval.  Technique Conserves Memory and Guarantees Capture of Lowest & Highest Signal Values per Storage Interval.

9 Stored True RMS Voltage / Current  Pa-9 can display:  MIN, MAX, and TRMS values for all channels for entire test. (Press HOME, select “Stored Data, RMS Interval”)  Trending graphs of any parameter right on pa-9. (ex. VA MIN trended over entire test)  Ms-pa9W software Tabular Report (right)  MIN, MAX, & RMS Reported at every storage interval.  Data for trending graphs  with scan line  click and drag zooming (next)

10 Notice the 5V dip (blue) when the large load turned on (red). Metrosonics pa-9 Scan Line, you can move to provide values in window

11 Out-Of-Limits Log  User Sets Following Limits By Channel  High/Low RMS Limits (V & I)  Sub-Cycle Impulse Magnitude.  THD%  Recorder Captures All Events Outside of User Preset Limits And Logs Them With Duration In Out-Of- Limits Log.

12 Stored Data: Event / Out of Limits Data  Out of Limits- While recording, continuously monitors for excedances of user defined limits for upper & lower V/I, sub- cycle (65uS), and THD.  Monitors all connected channels, for analysis between load / source side.  Large event memory up to 1,000 events!  Exact reporting of MIN, MAX, and RMS during event timeframe.  Reports events as short as 65uSeconds.

13 Waveform Capture  Waveforms Are Captured With  Event Trigger  Time Trigger  Manual Trigger from Front Panel  User Specifies Number of Pre-Trigger Cycles (Max 2) and Number of Post- Trigger Cycles (Max 99) To Capture.

14 Waveform Display

15 Ms-pa9W waveform chart triggered on loss of voltage. Metrosonics pa-9

16 Applications for pa-9: Waveform Capture - Motor Inrush  Waveform capture triggered on Rising Current  Three phase chiller start-up inrush.  Display all captured cycles on one screen. (Inrush decay envelop)  Same click and drag zoom and scan line features.

17 Demand Recording  User Specifies Demand Interval, Fixed Or Sliding Window, Configuration (Wye, Delta etc).  All Power Parameters Are Recorded (KW, KVAR, KVA, pf, dpf etc).  Power Data Can Be Recorded As Fast As Every 6 Cycles (1 Cycle In Future).

18 Stored Data: Demand Data (with power flow option)  ms-pa9W Software allows:  Printing and exporting of text data reported every storage interval  Trending graphs with click and zoom capabilities  Scan line reporting and vector diagrams (next)

19 Demand Graph with scan line feature and vector diagram. Metrosonics pa-9

20 Real Time Harmonic Analysis  FFT Done Every 6 Cycles.  Harmonic Analysis And Direction Of Harmonic Power Flow Presented On Display.  Generally A Good Indicator Of Source of Harmonics

21 Here we see we have nearly 75 Amps of Neutral Current, of which 45.9 Amps are comprised of the 3rd harmonic. (bar graph superimposed allows viewing to 63rd) Harmonic Analysis In Software

22 Software  32-bit Software Package ms-pa9W  Compatible with Win 95/98/NT  Generates Graphs/Reports  PQDIF Support Coming  IEC Flicker (Coming)

23 Future Software Enhancements (4Q2000)  Harmonic Trending  Total Demand Distortion (TDD%) Trending  CBEMA Scatter Diagram  Single Software Package for Multiple Models  Report Generator

24 Hardware: User Interface  RS-232 serial communications (to 115 KBAUD)  Graphical display:  View real time and stored data (text and graphical)  4 MB base memory  (expandable to 8 or 12MB)  Large tactile keypad for easy operation even with gloves on.

25 Hardware: Packaging  Packaging:  Rugged enclosure:  High impact  Smaller package (13x10x6)  NEMA 4X Weatherproof  Lockable hasps  Protective handles on input connector side.  Lightweight (15 lbs./ 6.8 Kg.)  Wide temperature range (-20C to +50C)

26 Hardware: Voltage Channels  4 Voltage Channels  150/600VAC + DC auto- ranging.  Safety banana jack inputs  Right angle prevents accidental pull out  Unfused probes standard, fused probes optional.  Resolution.1% full scale.  Accuracy.25% rdg +.05% full scale.

27 Hardware: Current Channels  5 Current Channels  Resolution.1% Full Scale  Accuracy.25% rdg +.05% range + probe accuracy.  Current probes  Cp-6000CE - 600/6000A  Powered from pa-9!!  1% reading accuracy!  1000A, 100A, 20A CT’s Avlbl  Adapter cable mates most Metrosonics ct’s to pa-9  On-site CT Selection Directly From pa-9 Without Reprogramming.

28 Hardware: Power Supply  VAC or VDC Operation.  Power From V(A channel) standard  No separate regulated 120VAC power source required  Optional (independent) AC power input.  Optional DC power input. (+12VDC)  Internal Sealed Lead Acid Battery.  Outage ride through time 15 minutes.  Non-Volatile Memory Data Retention.  External Ground Lug.

29 Summary: Unique Features  No Other Single Instrument Combines The Following Features  9 Channels. Measure AC or DC Voltage.  Simultaneously Record RMS/Power/Waveforms.  Capture Events As Fast As 65 Microseconds.  Capture 2 Pre-trigger Cycles & Many Post-trigger.  256 Sample/Cycle Rate + FFT Every Few Cycles.  Trigger On Current As Well As Voltage.  Measure Phase A Frequency.  Display Direction of Harmonic Power Flow.  Store 60 setups in the Recorder (Field Selectable).  Power Off Phase A Voltage With ac OR dc Voltage.  Wide Industrial Temperature Range.  Portable, Wall Mount, Rack Mount Packaging.

30 Key Front Panel Displays  Store Up To 60 Field Selectable Setups.  Select CT’s In The Field  View Event Log On Site

31 Planned Developments  Next Generation Software. Trend More Items (Harmonics, Freq.), State Compliance With Standards (CBEMA, IEEE 519, IEEE 1159).  Networking for Fixed Units. Internet Connectivity.  Expand Product Line. Keep Listening To Our Customers!

32 Pa-9 Starter Kit  Sk-pa Starter kit includes includes:  pa-9, w/ 12 MB internal memory  pa-9-PF Power Flow Option  ms-pa9W - 32 bit Windows software  ca-pa9-11- kit of 4 (unfused) voltage cables with alligator clips and a set of neutral jumper cables  ca-pa9 charging cable  ca-rs232 - db9 communications cable  (3) cp-6000CE 600/6000 Amp AEMC Flexible current probes (powered from pa-9)  SC-PA9 soft sided carry case  1 Year Warranty

33 Thank you for the opportunity of being Able to Show You The Capabilities of This Remarkable Instrument!! Have A Great Day