Pole Mounted Switch Disconnector NPS

Slides:



Advertisements
Similar presentations
Medium-Voltage Switchgear - Then and Now -
Advertisements

Earthing of MV and LV Distribution Systems: A multi-faceted problem.
Introduction to Switchgear
Electrical Installation
Gdpack 40.5kV Technical Data Sheet MV-LV Prefabricated Substation
April 27, 2012 Presented by: Andy Justice SWEDE Southwest Electric Distribution Exchange “The Evolution of Distribution Switchgear”
1 CNS/GSS/2008/M1 1 Module 1 Basic Terminologies and Characteristics of Switchgear.
M iniature circuit breakers to UL 489
SHS2 Gas insulated switch–disconnector / isolator
© Copyright year ABB. All rights reserved /1/2015 VBF OUTDOOR VACUUM CIRCUIT BREAKER 36kV PRODUCT INFORMATION.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ 7.2kV Motor Control Center.
Protection against Lightning Overvoltages Overvoltages due to lightning strokes can be avoided or minimized in practice by (d) shielding the overhead lines.
FIPTMV Medium Voltage Technology
EET Survey of Electronics
Proposed Design and the Operation of a Disconnecting Device for Small EG Installations Prepared by Hendri Geldenhuys.
SF6 load-break switch-disconnector
SUBSTATION HIGH VOLTAGE COMPONENTS
Electrical Power Systems
MV SF6 circuit-breakers for secondary distribution
Breaker Basics Welcome to this general overview of ABB.
EE4503 Electrical Systems Design
Multi-function apparatus for secondary distribution
PRESENTATION ON SUBSTATION DESIGN
Electricity Service Delivery 2 Aim To provide students with information to enable them to deal with the effects of electricity at incidents.
Frankfurt (Germany), 6-9 June 2011 V Ramesh – India – Session 1: Network components – 1096 Integrated Switching Devices (ISD) V.RAMESH ABB Limited, Nashik,
MNS Sprint - A Market Driven Solution
What makes substation work?
Frankfurt (Germany), 6-9 June 2011 ROSA – PT – S3 – 0249 EDP DISTRIBUTION AUTOMATION (r)EVOLUTION.
Medium Voltage Outdoor Apparatus Portfolio
SF6 load break fault make switches for overhead networks
PowerIT Air Insulated Cubicle Uniswitch
Cooper Bussmann Overview. Overview 2 Electrical Electronics Transportation World leader in Electrical fuse technology Solid growth in emerging markets.
POWER HOUSE.
Submitted to: Submitted by:
Introduction to switchgears
SERVICE ENTRANCE EQUIPMENT
Disconnector Switches and Earth Switches
What makes substation work?
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
OTDS Ltd. Overhead Transmission Distribution Systems OTDS OIL FILLED TRANSFORMERS | POWER TRANSFORMERS.
EE 2353 HIGH VOLTAGE ENGINEERING Faculty Name :A.JAIBUNISHA Faculty Code : EE 58 Designation : LECTURER Department : EEE.
ELECTRICAL INSTRUMENTS ( service and utilization )
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
AUTOMATIC CIRCUIT RECLOSER
Comparison of AIS and GIS Grid Station Muhammad Ali Ashraf Management Associate (Electrical) CPP Project.
Sub Station.
SUB-STATIONS.
Chapter # 25 Sub-Stations risemark.pbworks.com.
3AH5 Vacuum Circuit-Breaker For Standard Applications
Sectos NXB and NXBD.
Basics of electrical engineering
Circuit Breakers & Reclosers
MV vacuum circuit-breakers for secondary distribution
3AH5 Vacuum Circuit-Breaker For Standard Applications
Oil-tight MV fuse CEF-OT with TPC bushings
Engineering Project Cable Management.
Components of Substation
ELECTRICAL POWER-II Electrical engineering sixth semester
EET 323 – Electrical System Design Lecture 9: Grounding
EET 323 – Electrical System Design Lecture 11: Panel-boards and Switch-boards Instructor: Radian Belu, PhD.
Utilizing the ring operation mode of MV distribution feeders
3AH5 Vacuum Circuit-Breaker For Standard Applications
CIRCUIT BREAKERS E. Chikuni. Circuit Breakers Mechanical Switches capable of making and breaking currents under normal circuit conditions and for a specified.
Its strengths, your benefits
HIGH VOLTAGE ENGINEERING Presented By P.Sindhu Asst.Prof EEE Dept
Its strengths, your benefits
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Substation Equipment's
Presentation transcript:

Pole Mounted Switch Disconnector NPS 630 A, up to 36 kV

NPS Pole Mounted Switch Disconnectors Easy and smart integrations Adaptable to all customer/country building standards Modular concept Suitable for live working Flexible concept From the simplest of manually operated units to motorized and automated remotely controlled units Wide range of accessories Upgrading in switching performance

NPS Pole Mounted Switch Disconnectors Enhanced performance and improved reliability Only insulators with the best materials are used Cycloaliphatic epoxy with over 30 years of field experience in more than 50 countries High quality silicone or porcelain insulators are also available Lightweight design with a limited number of parts guarantees a long lifetime and trouble-free operation

NPS as a Line Switch Disconnector

Crossarm installation One of the most common building standards where the line switch disconnector is integrated on the same crossarm as the lines. Wooden poles are most often used for this type of installation.

Installation below live line Some building styles and standards require a separate crossarm below the line crossarm. Sufficient clearances to the pole and between phases can be arranged by the flexible arrangement of phase elements.

Installation above live line A typical installation example above the live line on a steel structure pole.

Vertical installation Used for branching lines down to cables. The vertically installed switch disconnector is also used as a transformer switch disconnector.

Two pole mounting All installation examples are also available for two-pole mounting. Pole fitting accessories for various pole types are also available wooden poles concrete poles steel poles and structures

NPS for Transformer Switch Disconnector/ NPF fuse holder

Fuse holders The NPS switch disconnector can be equipped with several types of fuse holders. The vertically mounted NPS can be used as transformer switch disconnector. The breaking capacity of the whip (25/50 A) is enough for disconnecting a fully loaded distribution transformer up to 800/1600 kVA. NPS24B1-J2 and NPAC5

Fuse holders If the pole element is horizontally mounted the fuse holder for HRC fuses (6.3, 16, 25 A) or (SMIA-KR_) melting fuses can be easily integrated (up to 63 A) to the switch disconnector. The fuses are replaced using isolated rods from ground level. NPS24B1-J2, NPAC9-J2 and NPAF7-J2

Fuse holders NPS can be equipped with integrated earthing contact for open and earthed position. The separate fuse holder for HRC and SMIA-KR_ can also be equipped with surge arresters for one-, two-, or three-phase installation. NPS24B1-J2 NPAE5 NPF24B2

Fuse holders NPS can be equipped with a separate fuse holder for DIN-type fuses (CEF outdoor HRC fuses). IEC 282 ANSI 7.2 kV up to 160 A 12.0 kV up to 100 A 17.5 kV up to 100 A 24.0 kV up to 100 A 36.0 kV up to 40 A 25.5 kV 160 A 25.8 kV 100 A 38.0 kV 40 A NPF24E5

Components for substation switch disconnectors

Accessories

Feeder Automation

One terminal with REC 523 can control up to 4 slave units.

DTU Operating Device for pole mounted switch disconnector type NPS or other types

DTU Operating Device The product range includes master and slave units Can be equipped with third party electronics/IED Two different cabinet sizes Complete with batteries and chargers Up/down tube operation of disconnectors Stainless steel cabinet and mechanism Dust tight (IP55) to secure long lifetime of critical electrical components High torque, alternative 1.2 sec or 3 sec operating time Best possible materials used Over 30 years experience Operating voltages: 24, 48, 110, 220 VDC 110, 230 VAC

Breaking devices on NPS24B for max. Ith/Idyn 16/40 kA NPS Basic pole element Disconnector (IEC) No breaking capacity For disconnecting functions only Provides a safe isolating distance NPS24B1-WWJ2

Breaking devices on NPS24B for max. Ith/Idyn 16/40 kA NPS with 25 A breaking whip Limited purpose switch disconnector (IEC) Breaking 25 A/24 kV 40 A/12 kV For disconnecting functions only Provides a safe isolating distance NPS24B1-J2 NPS24B1-J3

Breaking devices on NPS24B for max. Ith/Idyn 16/40 kA NPS with 50 A breaking whip Limited purpose switch disconnector (IEC) Breaking 50 A/24 kV 80 A/12 kV With extended breaking capacity in rural areas and transformer loads. NPS24B1-K1J2

Breaking devices on NPS24B for max. Ith/Idyn 16/40 kA NPS with 250 A breaking chamber Limited purpose switch disconnector (IEC) Breaking 250 A/24 kV For main lines and subtations where larger breaking capacity is needed. NPS24B1-K4J2

Breaking devices on NPS24B for max. Ith/Idyn 16/40 kA NPS with K5 air making and breaking chamber General purpose switch disconnector (IEC) Maximum breaking and independent spring assisted making capacity 630 A/24 kV 8 kA/24 kV 12.5 kA/12 kV For main lines and substations where both breaking and making capacity is needed. Excellent for remote and auto sectionalizers. NPS24B1-K5J2 NPS24B1-K5J3 NPAC9-J3

Breaking devices on NPS24A for max. Ith/Idyn 20/50 kA For overhead networks with BIL up to 150 kV. Silicone insulator J3. NPS24A2-J3 NPS24A2-K5J3 NPS24A2-K5J3 NPAC1-J3

Breaking devices on NPS36A for max. Ith/Idyn 21/52 kA For overhead networks with BIL, up to 200 kV. Whip (16 A) or breaking chamber K3 (400 A) can be used ase breaking elements. Two alternative silicone insulators (J2 or J3). NPS36A2-J2 NPS36A2-K3J2 NPS36A2-K3J2 NPAC11-J2

Unique design The unique design on breaking whips and dry type breaking chambers eliminates the risk of oil leakage. Risk of oil eliminated Pollution risk for soil waters Safety risk in case of failed interruption No need to check oil level or compensate for possible leakages Risk of conventional air breaking chambers eliminated by protected breaking contacts Malfunctions due to dust, sand, ice and small animals Risk of terrain fires due to arcing

Manual operating mechanism UEKE 5A1 Hook stick lever Hook stick operation mechanism for NPS24B_ models. Also available for mounting on lower level. UEKO 1A1 One hand grip operating mechanism for low end disconnectors

Manual operating mechanism UEKE 3A1 Standard two hand grip operating mechanism for all NPS_ models. UEKE 3B1 Standard two hand grip operating mechanism for all NPS_ models with additional quick adjustment rod.

Manual operating mechanism UEKE 2/1 With auxiliary contacts and heating element IP55. UEKE 6A1 Wire operation