الجامعة الإسلامية-غزة كلية العلــــــــــــــــوم قسم البصريات الطبية

Slides:



Advertisements
Similar presentations
Medical Retina and Macular Diseases
Advertisements

بسم الله الرحمن الرحيم Fluorescein & ICG Angiography F. Kianersi MD
Grand Rounds Peripheral Exudative Hemorrhagic Chorioretinopathy
DIABETIC RETINOPATHY.
Fundoscopic Examination
M.R.AKHLAGHI MD  It is based on ophthalmoscopic signs.
Unit 33 - Optics Optics is the study of the behavior and properties of light. This includes it’s interactions with objects including mirrors, lenses, and.
OCT OF MCULAR DISEASES DEHGHANI.A near infrared light near infrared light cross-sectional images of tissue cross-sectional images of tissue High resolution)
Reflection, Refraction and Lenses
and Optical Instruments
II From “Beam Paths” to the “Microscope” October 2008 Rudi Rottenfusser – Carl Zeiss MicroImaging.
Fundus camera A non-mydriatic Topcon retinal camera
LENSES.
DIABETES AND EYE DISEASE: LEARNING OBJECTIVES
Fundoscopy Skills A short course v5.
Ch 25 1 Chapter 25 Optical Instruments © 2006, B.J. Lieb Some figures electronically reproduced by permission of Pearson Education, Inc., Upper Saddle.
OCULAR MELANOMA.
Application of Lenses Lenses in Eyes
Diabetic Retinopathy. Diabetic retinopathy is the most common cause of new cases of blindness among adults years of age. Each year, between 12,000.
Volk Optical Laser Lenses Distributor Product Presentation December, 2009.
TYPES OF CAMERAS PART 1- WILLIAMS. QUESTIONS TO ANSWER 0 What are different types of cameras? 0 What makes a camera work? 0 What are the similarities.
Refraction and Lens. Refraction Refraction: the change in direction of a wave as it crosses the boundary b/w 2 media in which a wave travels different.
Lesson 3 Reading Guide - KC What is the difference between regular and diffuse reflection? What types of images are formed by mirrors and lenses? How.
What is funduscopy? And… Why is it important to you?
FFA Dr Aaron Ng. FFA Principles Fluorescence – Stimulated by light of shorter wavelength – Emission of light of longer wavelength Flurescein – Excitation.
 Using the direct opthalmoscope  Visualization of retinal structures  Differentiating arteries from veins  Locating Optic disc,Macula and Fovea  Identifying.
Lenses Chapter 30.
Physics 213 General Physics Lecture Last Meeting: Diffraction Today: Optical Instruments.
Light Chapter 18.
Diabetes and the Eyes Kenyon Anderson, O.D.. Blindness Risk Diabetic eye disease, caused by diabetes, is a leading cause of blindness and vision loss.
Direct Ophthalmoscopy
Diabetic Retinopathy.
Light Week 5 Properties of Light Lenses and Optical Tools Eye Structure and Function.
Direct Ophthalmoscope
Chapter 34 Lecture Eight: Images: II. Image Formed by a Thin Lens A thin lens is one whose thickness is small compared to the radii of curvature For a.
Mirrors and Lenses Chapter 14.
The Eye and Sight Describe the relationship between the structure of the eye and sight Contrast ways in which light rays are bent by concave and convex.
Ophthalmoscopy OP1201 – Basic Clinical Techniques Posterior eye
Guide to performing an Eye Exam with an Ophthalmoscope.
Diagnosis & Management of Diabetic Eye Disease A. Paul Chous, M.A., O.D., F.A.A.O. Tacoma, WA Specializing in Diabetes Eye Care & Education Part 6.
Thin Lenses. Any lens that is thicker in the center than at the edges will make parallel rays converge to a point and is called a converging lens. Lenses.
Notes 2-5 OPTICAL TOOLS. Cameras: How do they work? Light from object travels through one or more convex lenses Lens focuses light Puts an image on film.
by: Taren Haynes, Robert Barnes, Devin Guelfo, Ashley Evans.
Philip Anderton BOptom PhD Visiting Optometrist Manilla Health Service HNEAHS.
Light. Photon is a bundle of light related to the amount of energy Light travels in straight line paths called light rays
Blindness or low vision effects more than 3 million Americans 40 years and older, and this number is projected to reach 5.5 million by In addition.
Chronic Visual Loss. CHRONIC VISUAL LOSS 1. Measure intraocular pressure with a tonometer 2. Evaluate the nerve head 3. Evaluate the clarity of the lens.
Chapter 19. Reflection The smooth surface of the lake reflects light rays so that the observer sees an inverted image of the landscape.
Mirrors.
19.3 Optical Instruments
Mirrors. Types of mirror There are two types of mirror Plane (flat) Curved Concave (curves in) Convex (curves out)
Optics. dispersion Shorter wavelengths refract more than longer wavelengths – Violet light bent the most Color.
C.K.PITHAWALA COLLEGE OF ENG. &TECH. 1) PATEL DWIJ( ) 2) PATEL NISHIR J. ( ) 3) PATEL MILAN ( ) 4) JADAV ANAND ( )
Telescopes How do they work?. 1. History 2. Lenses & Hardware 3. Reflecting Telescopes 4. Refracting Telescopes.
Refraction. Refraction of Light When light waves pass from one medium to the next, its speed changes, causing it to bend. Going from lower to higher index.
1- Dx : Cataract. 2- Management: Referral to ophthalmologist. 2-Prevention:  sunglasses  Control of diabetes.  Avoid the use of topical steroids. Answer.
Old Fibrotic Vascular tissue in End-Stage Proliferative Retinopathy
FUNDUS FLUORESCEIN ANGIOGRAPHY
Date of download: 7/2/2016 Copyright © 2016 SPIE. All rights reserved. Subdivision of the retina in two treatment zones. The treated zones, I and II, are.
Chapter 33 Lenses and Optical Instruments
DIABETIC RETINOPATHY Süleyman ÖZEN.
Direct Ophthalmoscopy
Ophthalmic Optical Instruments I
Copyright © 2006 American Medical Association. All rights reserved.
RETINAL IMAGING AND FLUORESCEIN ANGIOGRAPHY
Akbar Etesam Por MD VITRORETINAL FLOWSHIP
Direct Ophthalmoscopy
Unit 3 Space Exploration
Presentation transcript:

الجامعة الإسلامية-غزة كلية العلــــــــــــــــوم قسم البصريات الطبية Islamic University - Gaza Faculty of Science Department of Medical Optics الجامعة الإسلامية-غزة كلية العلــــــــــــــــوم قسم البصريات الطبية Fundus camera

Fundus Camera Fundus camera optics are very similar to those of the indirect ophthalmoscope.

A fundus camera or retinal camera is a specialized low power microscope with an attached camera designed to photograph the interior surface of the eye, including the retina, optic disc, macula, and posterior pole (i.e. the fundus). Fundus cameras are used by optometrists, ophthalmologists, and trained medical professionals for monitoring progression of a disease, diagnosis of a disease (combined with retinal angiography), or in screening programs, where the photos can be analysed later.

fundus camera

Instruments for Imaging the Retina Optical Instruments Instruments for Imaging the Retina

Optical principles The optical design of fundus cameras is based on the principle of monocular indirect ophthalmoscopy.A fundus camera provides an upright, magnified view of the fundus. A typical camera views 30 to 50 degrees of retinal area, with a magnification of 2.5x, and allows some modification of this relationship through zoom or auxiliary lenses from 15 degrees which provides 5x magnification to 140 degrees with a wide angle lens which minifies the image by half. The optics of a fundus camera are similar to those of an indirect ophthalmoscope in that the observation and illumination systems follow dissimilar paths. The observation light is focused via a series of lenses through a doughnut shaped aperture, which then passes through a central aperture to form an annulus, before passing through the camera objective lens and through the cornea onto the retina.The light reflected from the retina passes through the un-illuminated hole in the doughnut formed by the illumination system. As the light paths of the two systems are independent, there are minimal reflections of the light source captured in the formed image.

The image forming rays continue towards the low powered telescopic eyepiece. When the button is pressed to take a picture, a mirror interrupts the path of the illumination system allow the light from the flash bulb to pass into the eye. Simultaneously, a mirror falls in front of the observation telescope, which redirects the light onto the capturing medium, whether it is film or a digital CCD. Because of the eye’s tendency to accommodate while looking though a telescope, it is imperative that the exiting vergence is parallel in order for an in focus image to be formed on the capturing medium. Since the instruments are complex in design and difficult to manufacture to clinical standards, only a few manufacturers exist: Topcon, Zeiss, Canon, Nidek, and Kowa.

principle of indirect ophthalmoscope same principle for fundus camera

Practical Retinal Illumination System GTT 04

GTT 05

hole in 45o mirror

Fundus camera camera or CCD

Applications Practical instruments for fundus photography perform the following modes of examination: Color, where the retina is illuminated by white light and examined in full color. Red-free, where the imaging light is filtered to remove red colors, improving contrast of vessels and other structures.

Angiography, where the vessels are brought into high contrast by intravenous injection of a fluorescent dye. The retina is illuminated with an excitation color which fluoresces light of another color where the dye is present. By filtering to exclude the excitation color and pass the fluorescent color, a very high-contrast image of the vessels is produced. Shooting a timed sequence of photographs of the progression of the dye into the vessels reveals the flow dynamics and related pathologies. Specific methods include sodium fluorescein angiography (abbreviated FA or FAG) and indocyanine green (abbreviated ICG) angiography.

Some pictuers was take by fundus camera..

Intraretinal Hemorrhage

PDR with Regressed NVD. Previous PRP

Mild NPDR

HTN retinopathy with AV nicking and mild vascular tortuosity

Picture artifact. Large optic cup Prominent foveal reflex

Hypertensive retinopathy with Arteriolar attenuation Hypertensive retinopathy with Arteriolar attenuation. Increased arterial reflex. AV nicking.

Proliferative retionpathy with regressed NVD. Previous PRP

Myopic degeneration with PPA and macular Chorioretinal atrophy

Nonexudative AMD with Drusen and RPE dropout..

Tigroid Fundus. Large optic cup

Proliferative retinopathy with previous PRP

Diabetic retinopathy with microaneurysms with macular exudates

Vitreous haze. Fleck Retinopathy · · Vitreous haze. Fleck Retinopathy

Subfoveal CNVM with surrounding subretinal hemorrhage and exudates

Advanced AMD with Geographic Atrophy involving fovea · · Advanced AMD with Geographic Atrophy involving fovea

Chorioretinal scar with fibrovascular stalk secondary to focal chorioretinitis

POHS with regressed macular CNVM, PPA, and punched out CR scar · POHS with regressed macular CNVM, PPA, and punched out CR scar

AMD with Mild intermediate drusen

Myopic Degeneration

AMD with severe large drusen

Diabetic retinopathy with Macular exudates at foveal edge, with possible CSME

Flat choroidal Nevus adjacent to optic nerve

Conjunctival nevus

Diabetic retinopathy with Macular exudates

POHS with regressed macular CNVM, PPA, and punched out CR scar