FARCOS: a versatile and modular Femtoscope Array for Correlations and Spectroscopy Chiara Guazzoni on behalf of the FARCOS collaboration Politecnico di.

Slides:



Advertisements
Similar presentations
First results of reactions induced by exotic beams in the region of 11 Be with CHIMERA array EURORIB'10 -Lamoura, Jura, France June 6 th -11 th 2010 L.
Advertisements

Advanced GAmma Tracking Array
GEANT4 Simulations of TIGRESS
Alpha Stucture of 12 B Studied by Elastic Scattering of 8 Li Excyt Beam on 4 He Thick Target M.G. Pellegriti Laboratori Nazionali del Sud – INFN Dipartimento.
Γ spectroscopy of neutron-rich 95,96 Rb nuclei by the incomplete fusion reaction of 94 Kr on 7 Li Simone Bottoni University of Milan Mini Workshop 1°-
Hybrid Detector Array ( ) The RIKEN-ATOMKI hybrid array Gábor Kalinka (ATOMKI, Debrecen) 3rd Japan-Hungary Joint Seminar on Physics in Modern Science.
Study of nuclear equations of state: the ASY-EOS experiment at GSI Simone Santoro 1,2 for ASY-EOS Collaboration 1 University of Messina 2 INFN - Catania.
Positronium Rydberg excitation in AEGIS Physics with many positrons International Fermi School July 2009 – Varenna, Italy The experimental work on.
GAMMA-PARTICLE ARRAY FOR DIRECT REACTION STUDIES SIMULATIONS.
24-28 May, 2010 S. Mastroianni - 17th Real-Time Conference, Lisboa, Portugal ARGO-YBJ is a cosmic ray air shower detector based on a single layer of RPC.
Direct Reactions at Eurisol In the light of the TIARA+MUST2 campaign at GANIL B. Fernández-Domínguez.
Study of the fragmentation of Carbon ions for medical applications Protons (hadrons in general) especially suitable for deep-sited tumors (brain, neck.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
N_TOF fission data of interest for ADS
Istituto Nazionale Fisica Nucleare
First simulations of FAZIA Napoli 3-5 September 2007.
ExternalTargetFacility at CSR FRIB-China East Lansing Sun, Zhiyu Institute of Modern Physics, CAS.
Fast Timing with Diamond Detectors Lianne Scruton.
Tools for Nuclear & Particle Physics Experimental Background.
Laura Francalanza Collaborazione EXOCHIM INFN Sezione di Catania - LNS.
The FARCOS project Collaboration: INFN (CT, LNS, MI, NA; Italy), GANIL (France), Un. Huelva (Spain) Synergies: Fazia, Neutron detectors, Spectrometers,
This experiment is to obtain the excitation functions of the 13 C (α, α) 17 O elastic scattering at the initial beam energy 13 C.
The High Resolution Array The High Resolution Array is a detector designed to detect and identify light charged particles like protons, deuterium, triton,
Digital analysis of scintillator pulses generated by high-energy neutrons. Jan Novák, Mitja Majerle, Pavel Bém, Z. Matěj 1, František Cvachovec 2, 1 Faculty.
Beam diagnostics in the beamlines
Experimental part: Measurement the energy deposition profile for U ions with energies E=100 MeV/u - 1 GeV/u in iron and copper. Measurement the residual.
Valerio Re, Massimo Manghisoni Università di Bergamo and INFN, Pavia, Italy Jim Hoff, Abderrezak Mekkaoui, Raymond Yarema Fermi National Accelerator Laboratory.
Hadronic interaction studies with the ARGO-YBJ experiment (5,800 m 2 ) 10 Pads (56 x 62 cm 2 ) for each RPC 8 Strips (6.5 x 62 cm 2 ) for each Pad ( 
Nucleus Nucleus 2015 – Catania June 2015 Catania, June 25 th 2015 Univ. degli Studi di Napoli Federico II & INFN - Napoli Study of cluster structures.
SIDDHARTA future precision measurement of kaonic atoms at DA  NE Florin Sirghi LNF SPRING SCHOOL "Bruno Touschek" In Nuclear, Subnuclear and Astroparticle.
FIT (Fast Interaction Trigger) detector development for ALICE experiment at LHC (CREN) Institute for Nuclear Research (INR RAS) National Research Nuclear.
FARCOS Femtoscope ancillary Array for Correlations & Spectroscopy G. Verde, INFN-Catania EXOCHIM collaboration, INFN (LNS-CT-MI-NA), Un. Messina, GANIL,
Prospects to measure 8 B production VLADIMIR KRAVCHUK Laboratori Nazionali di Legnaro, Italy EUROnu week in Strasbourg 1-4 June 2010.
HIE-ISOLDE diagnostic boxes Esteban D. Cantero CERN BE-BI-PM HIE-ISOLDE meeting for BE/BI 28 March 2014 The research leading to these results has received.
The INFN Italy EXOTIC group Milano, Napoli, Padova, NIPNE Romania, Crakow Poland. Presented by C.Signorini Dept. of Physics and Astronomy Padova (Italy):
Goddard February 2003 R.Bellazzini - INFN Pisa A new X-Ray Polarimeter based on the photoelectric effect for Black Holes and Neutron Stars Astrophysics.
Ciemat Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas Daniel Cano-Ott, DAQ meeting in Huelva, July 18 th and 19 th A new flash.
Status on the HYDE project Collaboration: University of Huelva, Spain (coordinator) GSI-Darmstadt, Germany. University of Sevilla, Spain. CSIC-IEM Madrid,
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
PSA: ADAPTIVE GRID SEARCH The Method Experimental Results Optimization aspects Roberto Venturelli (INFN Padova - IPSIA “Giorgi” Verona) SACLAY, 05-may-06.
RD51 GEM Telescope: results from June 2010 test beam and work in progress Matteo Alfonsi on behalf of CERN GDD group and Siena/PISA INFN group.
P.F.Ermolov SVD-2 status and experimental program VHMP 16 April 2005 SVD-2 status and experimental program 1.SVD history 2.SVD-2 setup 3.Experiment characteristics.
Laboratori Nazionali del Sud Start EXCYT status and perspectives L. CELONA on behalf the EXCYT collaboration Istituto Nazionale di Fisica Nucleare-Laboratori.
Institute of Basic Science Rare Isotope Science Project PANGEA P hoton detector system for A stro-science and N uclear physics with GE rmanium A rray 2015.
WP 7 (RDH) Detector for high intensity beam WP 6 (IRPT) New TERA chip development Leslie Karen Fanola Guarachi.
Exploring the alpha cluster structure of nuclei using the thick target inverse kinematics technique for multiple alpha decays. Marina Barbui June, 23 rd,
Michael Bendel intrinsic phoswich conzept – CALOR 2014 – Gießen 1 Michael Bendel Physik-Department E12 Technische Universität München a new technique for.
LEA-COLLIGA 4 th Meeting November 14-16, 2011 IPN Orsay - Paris Study and comparison of the decay modes of the systems formed in the reactions 78 Kr+ 40.
CALIFA - USC R&D activities: Designing and prototyping CALIFA a next generation calorimeter for R3B/FAIR Huelva July 07.
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
26th September 2014 Guillermo Ribeiro 1 G. Ribeiro, E. Nácher, A. Perea, J. Sánchez del Río, O. Tengblad Instituto de Estructura de la Materia – CSIC,
GEM gas detectors for Soft X-ray imaging in Fusion devices with neutron-gamma background and polycapillary lenses F. Murtas 2, S. Dabagov 2,4, L. Gabellieri.
52° International Winter Meeting on Nuclear Physics Status of art of FARCOS Project L. Acosta 2,8, F. Amorini 2, A. Anzalone 2, L. Auditore 4,5, G. Cardella.
FAST IN-MEDIUM FRAGMENTATION OF PROJECTILE NUCLEI
The PSD at Pb-Pb run PSD drawbacks at Ar beam
The Electromagnetic Calorimetry of the PANDA Detector at FAIR
Results achieved so far to improve the RPC rate capability
OSCAR: a modular low-threshold hodoscope
A new-concept Absorption Calorimeter for the ELI-NP facility
The Silicon Drift Detector of the ALICE Experiment
Diagnostics of FRIBs beam transport line
The interaction region for FIRST (status report)
78Kr+40Ca and 86Kr+48Ca at 10A MeV
DSSSD for b decay investigations of heavy neutron-rich isotopes
Angela Gligorova on behalf of the AEgIS and Medipix collaborations
BESIII EMC electronics
Commissioning of the ALICE-PHOS trigger
HE instrument and in-orbit performance
Status and perspectives of the LNS-FRIBS facility
Implantation detector as active stopper Rakesh Kumar, P. Doornenbal, I
Presentation transcript:

FARCOS: a versatile and modular Femtoscope Array for Correlations and Spectroscopy Chiara Guazzoni on behalf of the FARCOS collaboration Politecnico di Milano – Dip. di Elettronica e Informazione and Istituto Nazionale di Fisica Nucleare, Milano, Italy

Acknowledgement C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 2  The FARCOS collaboration: L. Acosta 1, F. Amorini 1, A. Anzalone 1, L. Auditore 2,3, C. Boiano 4, G. Cardella 5, A. Castoldi 6,4, A. Chbihi 7, E. De Filippo 5, L. Francalanza 1,8, E. Geraci 8,5, S. Gianì 1,8, C. Guazzoni 6,4, E. La Guidara 5,9, G. Lanzalone 1,10, I. Lombardo 11,12, S. Lo Nigro 8,5, D. Loria 2,3, C. Maiolino 1, I. Martel 13, T. Minniti 2,3, A. Pagano 5, E. V. Pagano 1,8, M. Papa 5, T. Parsani 6,4, S. Pirrone 5, G. Politi 5,8, F. Porto 1,8, F. Riccio 6,4, F. Rizzo 1,8, P. Russotto 1,8, A.M. Sánchez-Benítez 13, J.A. Duenas 13, R. Berjillos 13, S. Santoro 2,3, A. Trifirò 2,3, M. Trimachi 2,3 G. Verde 5, M. Vigilante 11,12 and P. Zambon 6,4  The FARCOS project is funded by: EXOCHIM experiment Protocol: 2009RLCYL8_ Univ. degli Studi di Catania 3. Univ. degli Studi di Messina 6. Politecnico di Milano 12. Univ. di Napoli ‘Federico II’ 10. Univ. di Enna ‘Kore’ 13. Univ. de Huelva 7. IN2P3, CNRS 5. Sezione di Catania 1. Lab. Naz. Del Sud 2. Gr. Collegato Messina, 4. Sezione di Milano 11. Sezione di Napoli 9. Centro Siciliano di Fisica Nucleare e Struttura della Materia

Outline  Introduction  Physics Goals & Instrumentation Requirements  FARCOS components  DSSSD qualification with mono-energetic pulsed ion beam  Preliminary on-beam tests  Conclusions and future work C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 3

Physics Goals  Heavy ions collisions (with stable and RI beams) as a probe for nuclear dynamics and the asy-EoS C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 4  Direct reactions with stable and radioactive beams dedicated RIB experiments imaging & correlation at intermediate energies  symmetry energy particle correlation at low energies  fusion, fission, … multi-particle correlation spectroscopy clustering and Bose condensates in nuclei Existing correlators: MUST IIHiRA

Instrumentation Requirements  High energy- and angular-resolution, to obtain the momentum vector and its correlation (  correlation measurements and direct reactions in inverse kinematics with RIB)  Wide solid angular coverage, to gain large statistics in two- or more-particle correlation  Low identification thresholds both for LCPs and IMFs (  low energy measurements with RIB at SPES and SPIRAL2)  Wide dynamic range to detect both LCPs and IMFs in the same event (  LCP- IMF correlation functions to ascertain temperature and excitation energy of primary fragments and (p,d) and (d,p) direct reactions in inverse kinematics with RIBs  High stopping power  high-energy LCPs correlations, ‘space-time’ snapshots of particle and complex fragments emitting sources  Simple, versatile, modular and transportable geometry  ease of coupling with other detectors (4  -arrays, spectrometers, neutron detectors) and temporary installation in different facilities. C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 5

FARCOS components: detectors C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 6 DSSSD, made by MICRON Semiconductor, on a standard design (BB7) with a minimum area PCB frame (4 mm wide) Front-side gap: 25  m, back-side gap 40  m Kapton cables directly bonded to each side of the welded detector Single clusterPossible geometries geometry of clusters follows the same radius with respect to the center of the target (i.e. each detector tangential to the imaginary sphere generated by a distance ”target-array” previously fixed) highly homogeneous CsI(Tl) crystals, made by SCIONIX, with Tl concentration of the order of 1200 to 1500 ppm each crystal wrapped with 0.12 mm thick white reflector including 50 micron of aluminized Mylar entrance window composed by 2  m thick aluminized Mylar with a density of 0.29 g/cm 2 output light read out by a Hamamatsu 18x18 mm PIN diode S , attached to the rear face of each crystal.

FARCOS components: front-end C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 7 Simplified schematic of one channel CPA Final assembly of a 32-channel preamplifier in a compact module 8 cm 10.5 cm Low power consumption: ~36 mW per channel Rise-Time (pulser): ~ 3-7 ns (C input =0-100pF) Energy resolution : (pulser) ~ 4.3 KeV (C input =0-100pF) Module with different sensitivities: 10, 20, 45 mV/MeV… Phase I.1: new design to accomodate 3 different user- selectable sensitivities in a single module Phase II: VLSI design under way in 0.35  m AMS CMOS technology both voltage mode and current mode solutions under investigation Phase 0: Mesytec MPR16 16 channels CPA Phase I: hybrid large bandwidth charge preamplifers

FARCOS components: DAQ Analog DAQ borrowed from CHIMERA detector Digital DAQ C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 8 Digital acquisition runs in parallel to analog DAQ on one selected DSSSD + 4 CsI(Tl) for on-line monitoring, raw waveforms storage, etc. Fast VME digitizers ( bits, up to 500 MS/s) Struck GmbH Custom Anti Aliasing Amplifiers with selectable gain and BW 64 channels from DSSSD + 4 CsI(Tl) + Triggers Host PC,connected via optical link on PCI bus, running custom SW under Linux 4 x 64 channels 300  m DSSSD 4 x 64 channels 1500  m DSSSD 4 x 4 CsI(Tl) 528 Total no. channels DSSSD readout CsI(Tl) readout

DSSSD qualification – I in collaboration with L. Carraresi and F. Taccetti, LaBeC, INFN, Firenze (Italy) in the framework of the ASPIDE experiment C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 9 Experimental setup at the DEFEL beamline of LaBeC, INFN, Firenze (Italy) see poster N S1, S2, S3: motorized slits (collimators) RPs: rotating platforms A1, A2: A3 tantalum apertures V1,V2,V3: high vacuum pumping station Electrostatic chopper deflects the continuous beam of the accelerator transversally across a slit  bunch of ions proceed downstream through an aperture for a short time lapse (of the order of one nanosecond). Adjustment of the size of the aperture with a motorized slit, and of the intensity of the continuous beam,  pulsed beam with a variable and finely controllable number of particles in each pulse, down to an average value much below 1 proton per trigger Position of interaction in a defined area of down to better than 100 µm × 100 µm. Proton energies tunable in the range 1-6 MeV. Repetition rate from a manual single shot up to hundreds of Hz Other ion types can be accelerated: He2+ up to 8 MeV, Li3+ up to 11MeV, C4+ up to 14 MeV. 3MV Tandetron DEFEL beamline Data taking: September 2012

DSSSD qualification - II C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 10 Energy calibration and non-linearity each bunch gives rise to a single event (detector charge collection time >> bunch duration) of amplitude proportional to the bunch multiplicity accurate energy calibration of each strip and of the corresponding preamplifier in a wide energy range measure the linearity of the overall system, 45mV/MeV CPA

DSSSD qualification - III C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 11 Energy resolution junction side strips ohmic side strips FWHM of single-proton peak for different kernel lengths keV 16.5 keV

DSSSD qualification - IV C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 12 2D position response matrix (front injection) junction side strips ohmic side strips C B A B12 B13 B12 F11 F12 F11 high spatial resolution of the proton beam allows scanning across the strips and record the waveform response waveform shape vs. interaction position strip profile and amount of sharing events 3MeV protons

Preliminary on-beam tests - I C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 13 Experimental setup CHIMERA exp. chamber LNS, Catania – July MeV/u protons 62 MeV/u  particles 20 MeV/u 20 Ne

Preliminary on-beam tests- II C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 14 F1F1F2F2 F3 F4F5 F6F6 F7F8 F9 F10 F11 F12 F13F14 F15F16 F17F18F19F20F21 F22 F23 F24 F25 F26 F27 F28 F29 F30 F31 F32 Mixed nuclei radioactive source (digital DAQ) junction side strips

Preliminary on-beam tests – II C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 15 Mixed nuclei radioactive source (digital DAQ) = keV (excluding F1)  = 1.74 keV 244 Cm 241 Am 239 Pu junction side strips

Preliminary on-beam tests - III C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 16 B1B2 B3 B4B5 B6B6 B7B8 B9B10 B11 B12B13 B14 B15B16 B17 B18 B19 B20 B21B22 B23 B24 B25 B26 B27 B28 B29B30 B31 B32 Mixed nuclei radioactive source (digital DAQ) ohmic side strips

Preliminary on-beam tests - III 17 Mixed nuclei radioactive source (digital DAQ) = 17.6 keV  = 7.35 keV 244 Cm 241 Am 239 Pu ohmic side strips

Preliminary on-beam tests - IV C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy MeV/u  particle beam on Pb target –  E-E – front strips (digital DAQ) junction side strips 3 He 4 He p d t elastic scattering peak E CsI  E Si

Preliminary on-beam tests - IV C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy MeV/u  particle beam on Pb target –  E-E – back strips (digital DAQ) ohmic side strips 3 He 4 He d t elastic scattering peak p E CsI  E Si

Conclusions and perspectives C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 20 FARCOS has been conceived as a versatile and modular femtoscope array for correlation and spectroscopy to address several open cases in nuclear physics (nuclear dynamics and asy-EOS) both with stable and with RI beams. Construction of the first clusters already finished with Phase I-version of the frontend electronics. Analog and digital pulse-shape DAQ configured. Full characterization of the 2D detector response in terms of energy and position reconstruction for DSSSD under way with monochromatic pulsed ion beam at DEFEL beamline at Labec, INFN, Firenze, Italy. Preliminary on-beam test at INFN – LNS in Catania. Excellent energy resolution achieved in true beam conditions (data analysis on-going, 11.9 keV FWHM at 239Pu line) First experiments with some FARCOS cluster coupled to the CHIMERA 4  detector in Phase I.1 hybrid frontend with selectable gain. Phase II VLSI frontend (AMS 0.35) under design in view of the assembly of many clusters and to reduce power disssipation.

C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 21 Thank you for your attention!

AAA C. Guazzoni – 2012 IEEE Nuclear Science Symposium – October 31, 2012 FARCOS: a Versatile and Modular Femtoscope Array for Correlations and Spectroscopy 22