Portable Working Standard and Power Quality Analyzer PWS 3.3 Portable Working Standard and Power Quality Analyzer
Advantages / Benefits Working Standard Functions 20 mV ... 600 V (phase-neutral) 1 mA ... 12 A direct connection 10 mA ... 100 A via clamp-on CTs Measurement of electrical parameters (UI, PQS, f, PF) incl. vector and waveform display, harmonic analysis Up to 2 pulse inputs Instrument transformer testing (CT/PT burden, CT/PT ratio) Accuracy 0.1 % / 0.05 % Options: CALSOFT Software Clip-on CTs: 1000 A LEMflex© up to 3000 A LiteWire Sensors
Advantages / Benefits Power Quality Analysis Functions 3 voltages/4 current channels Harmonics Interharmonics Signal voltages Dips Swells Interruptions Voltage unbalance Flicker Transient capture 200s (10 kHz) IEC 61000-4-30 Class A 15 min battery buffered EN50160 reports
Advantages / Benefits Communication USB (integrated, standard) Ethernet (integrated, standard) Analog modem (integrated, optional) GSM modem (external, optional) Memory & GPS Time Synchronisation Memory: flash memory card GPS Time Synchronisation (integrated, optional)
Connections Top view [1] Current inputs I1, I2, I3 [3] Phase connection U1, U2, U3 [2] Current outputs I1*, I2*, I3* [4] Neutral connection UN [5] Connection for Clamp-on CT1 [7] Connection Clamp-on CT IN/IE [6] Connection for Clamp-on CT2 [8] Impulse input / output
Connections Top view [9] Impulse input [11] Modem connector [10] Ethernet connector [12] USB connector [13] GSM modem [14] Compact flash card [15] Mains switch [16] Auxiliary supply connector
Connections Bottom view [17] Battery compartment (10 x R6/Mignon/AA 1.2V / 1.2 Ah NiMH accumulators)
Connections Front view [18] Color LCD display [19] Alphanumeric keypad [20] Menu card keys [21] Cursor keys [22] Enter key [23] Exit key [24] Connector for external keyboard
Optional current clamps to the PWS 3.3 Error compensated clamp-on CT’s for measurements in the range 5 mA … 10A and 10 mA … 100 A Clamp-on CTs for meas-urements in the range 100 mA … 1000 A
Optional current clamps to the PWS 3.3 Flexible current trans-formers FLEX 3000 for measurements up to 30 / 300 / 3000 A Hot sticks for measurements on high voltage potential - AmpLiteWire up to 2000 A - VoltLiteWire up to 40 kV
Operation Concept Symbols Display Control Elements
Software Meter – Main Menu Meter Testing Measurement Harmonics, Oscilloscope Energy Measurement Transformer Test Special Functions Installation (Setup)
Software Meter – Error Measurement
Software Meter – Measurement of UI, PQS and UIPQS
Software Meter – Wave form, Harmonics and Vector Diagram
Software Meter – Energy Measurement
Software Meter – Register Test
Software Meter – Voltage Burden Measurement (25% SN ≤ Sb ≤ 100% SN)
Software Meter – Current Burden Measurement (25% SN ≤ Sb ≤ 100% SN)
Software Meter – Voltage Ratio Measurement
Software Meter – Current Ratio Measurement
Software Meter – Special Functions
Software Power Quality – Main Menu First Row Online Measurement Power Quality Recording Power Quality Analysis
Software Power Quality – Recording menu Second Row Recording profile Recording configuration Recording setup Start / Stop PQ Recording
Software Power Quality – Recording profile / setup / configuration
Software Power Quality – Online Measurement
EN 50160 Power Quality Standard Low voltage: Un = 230 V
EN 50160 Power Quality Standard Low voltage: Un = 230 V How to read the table, two examples: EN 50160, 2.1 Frequency EN 50160, 2.6 / Supply voltage interruptions, short
IEC 61000-4-30 Standard Power Quality Measurement Methods Class A performance Used, where precise measurement is necessary Contractual applications Verification compliance with standard Resolving disputes Class B performance Low uncertainty Statistical surveys Trouble shooting
IEC 61000-4-30 Standard Power Quality Measurement Methods Class A requirement Aggregation algorithm Time clock uncertainty (at least 1s/24h) Flagging concept to avoid counting events several times Power quality parameters Power frequency Voltage and current magnitude Flicker Voltage Dips, interruptions, swells Current inrushes Voltage unbalances Harmonics/Interharmonics Voltage signals Transients
Software Power Quality – Online Measurement Advantages Quick configuration / start of recording of all PQ quantities Ideal for short-term analysis of PQ problems Recording/Analyzing of PQ situation during meter test On-line analyzing during recording Limitations Recording time limited to max. 10 hours Recording must be defined individually for each PQ quantity Storing not possible; only screen shot
Software Power Quality – Online Measurement UIPQSf Recording Function / Firmware Aggregation acc. IEC 61000-4-30 Cl. A
Software Power Quality – Online Measurement Dip / Swell / Interruption Analysis Function / Firmware (Dip Analysis) Theory (acc. IEC 61000-4-30 Cl. A) Dip / Interruption Analysis
Software Power Quality – Online Measurement Dip / Swell / Interruption Analysis Function / Firmware (Dip Analysis) Theory (acc. IEC 61000-4-30 Cl. A) 3-phase Interruption Analysis 3-phase Dip Analysis
Software Power Quality – Online Measurement Dip / Swell / Interruption Analysis Function / Firmware (Swell Analysis) Theory (acc. IEC 61000-4-30 Cl. A) Exceeding threshold of a certain percentage of Udin (declared input voltage)
Software Power Quality – Online Measurement Harmonics / Interharmonics Analysis Function / Firmware Aggregation acc. IEC 61000-4-30 Cl. A)
Software Power Quality – Online Measurement Harmonics / Interharmonics Analysis Function / Firmware Theory (acc. IEC 61000-4-30 Cl. A)
Software Power Quality – Online Measurement Harmonics / Interharmonics Analysis
Software Power Quality – Online Measurement Transient Capture Recorder / Table Display Autoscaling On / Off Display Min./Max. Values Start/Stop Recording Saving / File Management Exit to previous Menue
Software Power Quality – Online Measurement Signal Voltage Analysis Setting of Signal Frequency Auto Detection of Signal Frequency Setting of Nominal Voltage Setting of Signal Voltage Level
Software Power Quality – Online Measurement Flicker Measurement
Software Power Quality – Online Measurement Unbalance Measurement Zero sequence voltage unbalance factor [%] Negative sequence voltage unbalance factor [%]
Software Power Quality – Analysis Recorder Analysis Bar Graph Analysis Result Summary
Software Data Base – Main Menu Administrative data Meter data Transformer data Load point data View test result Basic settings
Software Data Base – Administrative Data
Software Data Base – Meter Data
Software Data Base – Transformer Data
Software Data Base – View Test Results
Windows©-Software CALSOFT – Main Functions
Windows©-Software CALSOFT – Power Quality PQ Online Measurement
Windows©-Software CALSOFT – Power Quality PQ Recording
Windows©-Software CALSOFT – Power Quality PQ Analysis
Windows©-Software CALSOFT – PQ Online Measurement Advantages Same functions as in PWS 3.3 device Analysis functions organized by folders
Windows©-Software CALSOFT – PQ Online Measurement
Windows©-Software CALSOFT – PQ Recording/Evaluation Profile Functions Recording Options Setup U and I inputs Start/Stop of Recording
Windows©-Software CALSOFT – PQ Recording/Evaluation Profile Functions Preparation/Saving of analysis profiles Transfer of analysis profiles to the device
Windows©-Software CALSOFT – PQ Recording/Evaluation Profile
Windows©-Software CALSOFT – PQ Recording Options - Start time/length Functions Configuration of recording start Configuration of recording in blocks Definitions of time block interval
Windows©-Software CALSOFT – PQ Analysis Functions General Info Recorder Analysis Bar Graph Analysis Summary Result Overview
Windows©-Software CALSOFT – PQ Analysis
ETHERNET communication PWS 3.3 as DHCP Server IP - address PWS 3.3 can be fixed PWS 3.3 can allocate IP-address e.g. to locally connected PC
ETHERNET communication PWS 3.3 as DHCP Client PWS 3.3 will be given IP-address from server (e.g. if installed in a in- house or remote network)