HVACR416 - Design Duct Fittings and Components. Elbows 23.4.6 Elbows are 90° bends (unless otherwise specified) in ducts. Airflow is diverted from a straight.

Slides:



Advertisements
Similar presentations
AIR DISTRIBUTION (Additional information. Also see Chapter 18) General The proper delivery of air for heating, cooling, or ventilation is a crucial part.
Advertisements

Construction Methods and Materials HVACR HVACR. Construction Methods and Materials HVACR Comfort Equipment required to control: Temperature Moisture Air.
USER MAINTENANCE.
Fans and Blowers.
“Enerpak” Units » Propeller Type Fan » Size 100 – 400 MBH » 80% Thermal Efficiency » Natural or LP Gas » 10 Year Warranty on Heat Exchanger, Burners,
Fan Coil Unit Product Line-up. FCU Home Application Show.
HVAC CONTROLS (See section 18.9)
Heating, Ventilating, and Air-Conditioning
Refrigerators.
TYPES OF MECHANICAL SYSTEMS
Basic Refrigeration Cycle
JET PROPULSION Part 5 Jet Engine Operation Oil Systems.
SUPPLY DUCT SYSTEMS (Additional information. Read sections 18.4, 18.5, & 18.6) General –The supply duct system conveys conditioned air from an AHU to the.
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
Propulsion Train & Shaft Line Components
AIR FLOW IN DUCTS Shaharin Anwar Sulaiman
Local Exhaust Hoods. 2 Introduction:  Designed to capture and remove harmful emissions from various processes prior to their escape into the workplace.
EARLIER KITCHENS PRESENT DAY KITCHEN Common misconceptions of kitchen ventilation. In a commercial kitchen the prime concern of the owners, designers,
Airflow Properties & Measurement
System Effects Presented by: Joe Brooks, AMCA International, Inc. AMCA International Technical Seminar 2009.
HVACR 317 – Refrigeration Core
ARCH-4372/6372 HVAC Distribution & Sizing HVAC Distribution Systems
HVACR416 - Design Air Distribution Air Properties and Behavior Important properties of interest include: o Weight of air. o Manner in which air.
Flow Produced Noise & Fluid Mechanical Treatment Flow Produced Noise & Fluid Mechanical Treatment Prepared By: Eng. Ashraf Al-Shalalfeh Mechanical Engineering.
COMMERCIAL REFRIGERATION
HVACR416 - Design Pressure Measurement Part 2. Pressure Measurement Several pressure measurements exist. They all measure the same things, the force of.
Local Exhaust Ventilation
Evaporators For Air Conditioning
Fuel/Lube Oil Systems - AND – Propulsion Train & Shaft Line Components
Hydronic Mechanical Controls
Fans.
1 HVACR316 - Piping Condensation Removal Refrigerant Traps Condensation Removal Refrigerant Traps.
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
Learning, our way Examples of bad installation. CONTENT Installation related examples Installation related examples Application related examples Application.
Chapter 12: Fans and Building Air Distribution
Air Handler Terminology
AIR BEARING SYSTEM.
Noise Control A Guide for Workers and Employers. Steps used to solve Noise Control Problems Define the problem Establish a noise reduction target Determine.
Air Handler Terminology
Chapter 11: Space Air Diffusion Conditioned air is normally supplied to air outlets at velocities much higher than would be acceptable in the occupied.
CHAPTER 5: Mass and Energy Analysis of Control Volumes
Drafts and Duct System Sizing
1 Air Conditioning Air System problems. 2 The primary problem that can occur in an air system is the reduction in airflow. Air handling systems do not.
HVACR416 - Design Air Distribution Part 2. Air Ducts Air carriers that deliver air to conditioned space. Originally hot air ducts were thin, tinned sheet.
Why Maintenance Tasks are Important Produced by Joe Marchese.
HVACR416 - Design Pressure Measurement Part 1. Why Measure? Need to Make Sure: All combustion appliances vent properly All HVAC systems are installed.
AIR FLOW IN DUCTS Shaharin Anwar Sulaiman
Forward Plenum Clean control rodsOil control rods.
Introduction to Energy Management. Week/Lesson 10 Air Moving Equipment: Fans and Ducts.
Objectives Describe room distribution basics Select diffusers
AIR CONDITIONING (COOLING) UNIT 37 AIR DISTRIBUTION AND BALANCE
4.0 Equipment Installation Aspects (Section 4.5 On-Rate for Fuel-Fired Equipment)
FANS & BLOWERS Presented By Pranav 11MTFTFE009 Food Engineering.
4/28/2017 6:10 PM CENTRIFUGAL FAN © 2007 Microsoft Corporation. All rights reserved. Microsoft, Windows, Windows Vista and other product names are or may.
Space Air Diffusion. Fundamentals  Objectives – thermal comfort and indoor air quality – even space air conditions – acceptable air cleanliness – acceptable.
Teknologi dan Rekayasa Fans & Blowers. Training Agenda: Fans & Blowers Introduction Types of fans and blowers Assessment of fans and blowers Energy efficiency.
Gas Turbine Power Plant
Types of material handling equipment
Fixed Orifice Tube Cycling Clutch System (FOTCC)
VENTILATION NOISE.
Fans.
Air Conditioning System-1
Objectives Finish with Duct Design Diffuser Selection
Mandatory Design Requirements
FBE03: Building Construction & Science
Prof. H. D. Mhatre BELT DRIVE Prof. H. D. Mhatre Prof. H. D. Mhatre.
Correct Procedures for Changing, Storing, and Maintaining Saw Blades
Presentation transcript:

HVACR416 - Design Duct Fittings and Components

Elbows Elbows are 90° bends (unless otherwise specified) in ducts. Airflow is diverted from a straight line using elbows. Air has inertia. Once set in motion, air tends to continue in the direction it is moving. Air wants to flow in straight line. It takes energy to make airflow change direction.

Elbows

Fans Airflow is generally produced by some type of fan that is usually located in the inlet of the air conditioner. Air is moved by creating a positive or negative pressure. The air inlet to the fan is a negative pressure. The exhaust of the fan is a positive pressure.

Fans Air feed into the fan is called induced draft. Exhaust from the fan is called forced draft. Fans are constructed of metal or plastic. There are several types of fans. The two most popular are: o Axial flow (propeller). o Radial flow (centrifugal flow). Air flowing along the direction that the is axle is pointing is called axial flow. Air flowing at a right angle to the axle (radius) is called radial flow.

Fans

Fans This is a three-blade axial flow fan with a clockwise rotation. Axial flow fans are usually direct-driven by mounting the fan blades on the motor shaft. Handle blades carefully. If bent or twisted, the blades must be replaced.

Fans Radial flow fans are most often used on large installations. Maybe belt or direct drive.

Fans Fan Designations Low pressure, Class I Less than 3 3/4" (9.5 cm) Medium pressure, Class II 3 3/4" to 6 3/4" (17 cm) High pressure, Class III 6 3/4" to 12 1/4" (31 cm) High pressure, Class IV Greater than 12 1/4" (31 cm)

Radial Flow Fans Two designs: o Backward-inclined blades (for large units). o Forward-inclined blades (for small units).

Radial Flow Fans Static pressure increases as the square of the ratio of increase in the volume of airflow. For example: o 1000 cfm to 2000 cfm is two times more flow. Therefore, 2 2 = 2 X 2 = four times more static pressure. Static pressure increase is the square of the ratio of the change in rpm.

Radial Flow Fans Ways to measure performance of fan: o Pressure difference across fan—Inlet velocity pressure equals outlet velocity pressure (due to conservation of mass). o Static pressure. o Velocity pressure. o Static pressure difference. o Some technicians measure pressure relative to room air pressure.

Radial Flow Fans Formula for determining fan capacity for the furnace: Btu/hr furnace output cfm = X air temperature rise in °F Air temperature rise in °F is determined by measuring the warm air supply plenum temperature and subtracting the cold air return temperature. The factor is the total external static pressure. For cooling, use 400 cfm/ton of capacity. Total pressure drop in ducts should be about 0.2" of water column. For a furnace with cooling unit, the fan should provide.10 of water column.

Radial Flow Fans To provide more efficient belt drive, belt tension should be on lower belt section.

Radial Flow Fans The belt tension is correct when the belt can be pushed out of line a distance equal to its width. Fan speed may be varied using adjustable (variable pitch) pulleys.

Radial Flow Fans All fans collect dirt and lint, which reduce efficiency. Every six months, remove the fan and scrape, rub, or vacuum the dirt from the blades. Oil each bearing with one or two drops of oil each year. If bearings are oiled too much, the oil may coat the fan blades.

Special Duct Problems and Duct Maintenance 23.5 If ducts are not concealed, they may need painting. o Ducts made of galvanized (zinc-coated) steel must be treated prior to painting. Duct systems should have no “dead ends” where dust and stagnant air may collect. Reversing the airflow may loosen some of the dust that can then be caught in the filter. Periodic duct cleaning should occur to maintain proper airflow. Aluminum-to-steel joints encourage corrosion due to electro-chemical action. Joints between dissimilar metals should be avoided.

Smoke Detectors 23.5 City and state codes may require smoke detectors in residential and commercial structures. Detectors must be properly located. High-velocity air from ducts may keep detectors from working. If a long horizontal run of duct ends at an outlet grille that is not concealed, the smoke detector should be hung on the underside of the duct just behind the outlet grille. In residential systems, smoke detectors should be as far away from grilles as possible. Never place detectors in corners where there is almost no airflow.

Noise Two common problems with air distribution systems are noise, produced by movement or vibration, and drafts. Three factors that affect noise are the noise source, carriers, and noise amplifiers or reflectors. Noises may be: o High pitch sound. Usually caused by air velocity that is too high. Possibly due to sharp metal edges. o Low pitch rumble. Usually caused by fan and motor sounds traveling along duct system. o Popping sound as unit starts or stops. Caused by expansion or contraction of the duct.

Noise To locate the source of a high-pitched sound, remove the grille or diffuser. If the noise stops, it was due to sharp edges. Locate and correct the problem. Decibel meters measure noise level. o Decibels (dB) refer to the frequency of pressure fluctuations in the air and the amplitude, or size, of these vibrations. o Airborne sound is expressed in cycles per second (cps).

Noise Sources of noise: o Fans and motors. o High-velocity air traveling through ducts and causing turbulence. o Sucking and throbbing noises produced by compressors. o High-velocity refrigerant flow, especially at sharp bends in the piping. Noise caused by high-speed air is often the result of an undersize unit or duct.

Noise Rigid structures are noise or vibration carriers. Hard, smooth surfaces in the conditioned space may reflect or amplify sound. Soft fabrics, such as drapes, curtains, and fabric-covered furniture, are noise absorbers. Felt-lined, soft-insulation-lined, and covered ducts absorb noise.