Timing performance of the silicon PET insert probe Andrej Studen Jožef Stefan Institute Ljubljana, Slovenia On behalf of the Madeira collaboration.

Slides:



Advertisements
Similar presentations
Andrej Studen, Karol Brzezinski, Enrico Chesi, Vladimir Cindro, Neal H. Clinthorne, Milan Grkovski, Borut Grošičar, Klaus Honscheid, S. S. Huh, Harris.
Advertisements

Figure 5. Histogram of the decay constant. Black curves: raw histograms; Blue curve: Gaussian fit to the histogram from the 20GS/s waveform; Red curve:
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
VALENCIA b mass effects at the Z 0 peak from 3 and 4 jet events P. Bambade, M.J. Costa, J. Fuster and P. Tortosa b mass effects have been.
TOF at 10ps with SiGe BJT Amplifiers
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
The performance of silicon detectors for the SiliPET project: A Small Animal PET Scanner based on Stacks of Silicon Detectors Natalia Auricchio, Giovanni.
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Very High Resolution Small Animal PET Don J. Burdette Department of Physics.
Why silicon detectors? Main characteristics of silicon detectors: Small band gap (E g = 1.12 V)  good resolution in the deposited energy  3.6 eV of deposited.
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
Charge collection studies on heavily diodes from RD50 multiplication run (update) G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
First Results from a Test Bench for Very High Resolution Small Animal PET Using Solid-State Detectors Klaus Honscheid for The CIMA Collaboration The Ohio.
SiW ECAL Technological Prototype Test beam results Thibault Frisson (LAL, Orsay) on behalf of the CALICE collaboration.
A Front End and Readout System for PET Overview: –Requirements –Block Diagram –Details William W. Moses Lawrence Berkeley National Laboratory Department.
Fully depleted MAPS: Pegasus and MIMOSA 33 Maciej Kachel, Wojciech Duliński PICSEL group, IPHC Strasbourg 1 For low energy X-ray applications.
Performance of a 128 Channel counting mode ASIC for direct X-ray imaging A 128 channel counting ASIC has been developed for direct X-ray imaging purposes.
Time Resolution of Thin LGADs Results from the Nov 2014 Beam Test at CERN Improvement in hand: Sensor Capacitance Measurements with  Front TCT 1 Hartmut.
Performance limits of a 55  m pixel CdTe detector G.Pellegrini, M. Lozano, R. Martinez, M. Ullan Centro Nacional de Microelectronica, Barcelona, 08193,
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
DESPEC A Algora IFIC (Valencia) for the Ge array working group.
16. January 2007Status Report On Compton Imaging Projects 1 Status Of Compton Imaging Projects Carried Out In The CIMA Collaboration HPD Brain PET Meeting.
DEAR SDD --> SIDDHARTA
TCT measurements with SCP slim edge strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko.
LHCb Vertex Detector and Beetle Chip
Prostate probe with SPECT technique NSS – MIC November 5 - KnoxvilleF. Garibaldi- INFN – Roma1 – gr. Coll. ISS  the medical problem  the proposal.
T. Lari – INFN Milan Status of ATLAS Pixel Test beam simulation Status of the validation studies with test-beam data of the Geant4 simulation and Pixel.
Timing in Thick Silicon Detectors Andrej Studen, University of Michigan, CIMA collaboration.
-1-CERN (11/24/2010)P. Valerio Noise performances of MAPS and Hybrid Detector technology Pierpaolo Valerio.
Development of radiation hard Sensors & Cables for the CBM Silicon Tracking System Sudeep Chatterji On behalf of CBM-STS Collaboration GSI Helmholtz Centre.
Click to edit Master subtitle style Presented By Mythreyi Nethi HINP16C.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
Potential Advantages of Digitally Sampling Scintillation Pulses in Time Determination in PET Q. Xie 1,2, C.-M. Kao 1, X. Wang 2, N. Guo 2, C. Zhu 2, H.
A Multi-Threshold Method for TOF-PET Signal Processing Heejong Kim 1, Chien-Min Kao 1, Qingguo Xie 1, Chin-Tu Chen 1, Octavia Biris 2, Jialin Lin 2, Fukun.
3 May 2003, LHC2003 Symposium, FermiLab Tracking Performance in LHCb, Jeroen van Tilburg 1 Tracking performance in LHCb Tracking Performance Jeroen van.
November, 7, 2006 ECFA06, Valencia, Spain LumiCal & BeamCal readout and DAQ for the Very Forward Region Wojciech Wierba Institute of Nuclear Physics Polish.
Update on works with SiPMs at Pisa Matteo Morrocchi.
CdTe prototype detector testing Anja Schubert The University of Melbourne 9 May 2011 Updates.
ADC values Number of hits Silicon detectors1196  6.2 × 6.2 cm  4.2 × 6.2 cm  2.2 × 6.2 cm 2 52 sectors/modules896 ladders~100 r/o channels1.835.
Philip Bambade, Pierre Barillon, Frédéric Bogard, Selma Conforti, Patrick Cornebise, Shan Liu, Illia Khvastunov Journée PHIL
Hybrid CMOS strip detectors J. Dopke for the ATLAS strip CMOS group UK community meeting on CMOS sensors for particle tracking , Cosenors House,
A Forward Calorimeter (FoCal) as upgrade for the ALICE experiment at CERN S. Muhuri a, M. Reicher b and T. Tsuji c a Variable Energy Cyclotron Centre,
V.Aulchenko 1,2, L.Shekhtman 1,2, B.Tolochko 3,2, V.Zhulanov 1,2 Budker Institute of Nuclear Physics, , Novosibirsk, Russia Novosibirsk State University,
Prostate probe with SPECT technique NSS – MIC November 5 - KnoxvilleF. Garibaldi- INFN – Roma1 – gr. Coll. ISS  the medical problem  the proposal.
Timing capabilities of Ultra-Fast Silicon Detector 1 A parameterization of time resolution A program to calculate Time resolution UFSD Timing capabilities.
TCT measurements with strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž 1,2, Marko.
Pixel Sensors for the Mu3e Detector Dirk Wiedner on behalf of Mu3e February Dirk Wiedner PSI 2/15.
MADEIRA Valencia report V. Stankova, C. Lacasta, V. Linhart Ljubljana meeting February 2009.
Analysis of LumiCal data from the 2010 testbeam
Silicon microstrip detector for imaging of fast processes at high intensity synchrotron radiation beam. Budker INP V.Aulchenko1,2, L.Shekhtman1,2, B.Tolochko3,2,
Application of VATAGP7 ASICs in the Silicon detectors for the central tracker (forward part) S. Khabarov, A. Makankin, N. Zamiatin, ,
Huagen Xu IKP: T. Randriamalala, J. Ritman and T. Stockmanns
Comparison of GAMMA-400 and Fermi-LAT telescopes
Summary of the Compton-PET project
Integration and alignment of ATLAS SCT
K. Sedlak, A. Stoykov, R. Scheuermann
A Low Power Readout ASIC for Time Projection Chambers in 65nm CMOS
A Fast Binary Front - End using a Novel Current-Mode Technique
Next generation 3D digital SiPM for precise timing resolution
Gamma-Gamma Correlations in Na-22
Preliminary Compton Imaging results of the AGATA C001 detector
High Rate Photon Irradiation Test with an 8-Plane TRT Sector Prototype
CCE measurements with Epi-Si detectors
Backgrounds using v7 Mask in 9 Si Layers at a Muon Higgs Factory
ME instrument and in-orbit performance
Benchmarking Tracking by Doppler Reconstruction
Why silicon detectors? Main characteristics of silicon detectors:
Gain measurements of Chromium GEM foils
Presentation transcript:

Timing performance of the silicon PET insert probe Andrej Studen Jožef Stefan Institute Ljubljana, Slovenia On behalf of the Madeira collaboration

My co-authors: C. Lacasta, G. Llosa, V. Linhart, V. CSIC-IFIC Valencia H. Kagan, E. Cochran, D. Burdette, P. Weilhammer, E. OSU, Columbus, USA N. UM, Ann Arbor, USA M. Mikuž, D. Žontar, V. Cindro, B. JSI,Ljubljana, Slovenia

The MADEIRA collaboration Acronym stands for Minimizing Activity and Dose with Enhanced Image quality with Radiopharmaceutical Administration. Specific objectives:  Increased image quality with physics based image reconstruction methods  Novel instrumentation techniques  New time schemes for the application of the radiopharmaceuticals  Model bio-distribution for enhanced dosimetry

PET probe insert Improve image quality by recording events with good spatial information (proximity focus). Work in coherence with conventional external ring to minimize artifacts due to limited angle tomography. Also known as Virtual Pinhole PET (Tai et al., JNM 49(3) 2008)

PET Probe We chose high resistivity silicon in form of segmented pin diodes as the probe sensor. Properties: Supreme spatial resolution (1 um achieved) Compactness, robustness; ideal for probes (“monolithic” sensor, no amplification required) Mature development and processing. Excellent energy resolution. Works in magnetic fields. However:  Low efficiency (2 % per 1 mm thick sensor for PET photons, all Comptons)  Timing.

PET probe model A test sensor used for material test: 256 pads, 1.4 x 1.4 mm2 square pads 1 mm thick, same wafer/material as the probe sensor Coupled to same electronics as the final probe. First stage electronics done on application specific integrated circuit (ASIC) in a form of a silicon chip. ASIC is called VATAGP7, made by Gamma Medica – IDEAS, Norway.

VATAGP7 Self-triggering circuit: the input is split into slow & fast channel; fast channel is fed to a leading edge discriminator for the trigger signal. Fast shaper: 50 ns nominally (more later) Slow shaper: 500 ns Sample and hold circuit to fix analog value at max. Sparse readout:  Only hit channel read  Address and (buffered) analog value

Timing setup Test the module with 22-Na annihilation photons Timing reference: LYSO/PMT setup coupled to constant fraction discriminator (CFD). Time to analog converter (Ortec TAC 566) and peak sensing ADC (CAEN V785) digitize the trigger delay. Record energy of interaction in Silicon and delay between LYSO and Si trigger.

Results There are 3 contributions to timing uncertainty: Time-walk (blue) Jitter Broadening related to position of interaction For time-walk corrected events, position related broadening dominates: Do we understand it? Can we compensate? Can we live with it?

Time resolution and position of interaction Point-like photon interactions Induction; Ramo theorem I=e 0 v E w Ionization transport; v= μE; E not homogeneous Simulation: GEANT 4 for particle tracks TCAD for 3D weighting field Some heavy C++ 1 mm 3 cube; 511 keV incident photon Pad sidebackplane Pad side backplane GEANT 4 TCAD

Signal formation in silicon (animation) Animation of 100 electron-hole pairs created at 250 um (left) and 750 um (right) depth in sensor Electrons are dyed red, holes black Raw signal (per pair) on electrode (current in pA, time in ns) shown.

Comparison to simulation Simulation is a good description of the data (!) Good agreement even without jitter! Shaping time discrepancy (50 ns expected, excellent fit for 150 ns found) → talk to chip designer :-( Position related broadening is understood.

Voltage scan Increasing bias voltage is a simple remedy ( U→E→v). Well matched to simulation up to 430 V.

Efficiency performance Timing extremely important for proper event matching Typical time-windows between 6 ns (LYSO) to 12 ns (BGO) [Saha, 2005] Compromise between efficiency and rejection of randoms Efficiency Time window 10 ns20 ns20 ns 200 V 30 ns keV51 %75 %61 %86 % keV56 %81 %67 %93 %

Predictions of probe performance The only significant change is reduction in pad size (1.4 → 1 mm) This influences only the weighting field. Rely on simulation to anticipate probe performance

Summary & Conclusions We measured timing properties of silicon sensors which will be used for MADEIRA PET probe Good agreement to theory/simulations was found Timing resolution is significantly deteriorated due to position of interaction related broadening. Broadening can be reduced by over-biasing the sensors. Timing window will be a compromise between random event rejection and efficiency. The performance of the actual probe will not differ significantly from the tested model.