CLRS 321 Nuclear Medicine Physics & Instrumentation I Part C: Semiconductors and Miscellaneous Scintillation Devices Unit II: Nuclear Medicine Measuring.

Slides:



Advertisements
Similar presentations
Semiconductors Chapters
Advertisements

Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Detecting Ionising Radiation James Gray University RPA.
Radiation Safety Course Radiation Monitoring Heath de la Giroday Dispensing Chemist Radiation Safety Officer.
Detecting and Measuring Ionizing Radiation -2
Nuclear Radiation Basics. Copyright © 2011International Medcom Contents What is Radiation? What is Radiation? Instruments that Measure Nuclear.
Physics of Semiconductor Devices. Formation of PN - Junction When a P-type Semiconductor is joined together with an N-type Semiconductor a PN junction.
Semiconductor Devices Lecture 05
Integrated Circuit Devices
Course: ETE 107 Electronics 1 Course Instructor: Rashedul Islam
Kristin Ackerson, Virginia Tech EE Spring A DIODE IS A SEMICONDUCTER DEVISE, IT A ACTIVE COMPONENT WHOSE PROVIDE BEST FLOW OF CURRENT. IT IS A PN.
Conduction in Metals Atoms form a crystal Atoms are in close proximity to each other Outer, loosely-bound valence electron are not associated with any.
Contents : CONSTRUCTION PRINCIPLE OF OPERATION CHARACTERISTICS ADVANTAGES DISADVANTAGES APPLICATION.
Diodes Benchmark Companies Inc PO Box Aurora CO
Doped Semiconductors Group IVA semiconductors can be “doped” by adding small amounts of impurities with more or fewer than 4 valence electrons. e.g. add.
1 Detectors RIT Course Number Lecture Single Element Detectors.
Radiation Safety level 5 Frits Pleiter 02/07/2015radiation safety - level 51.
Main detector types Scintillation Detector Spectrum.
EE580 – Solar Cells Todd J. Kaiser Lecture 05 P-N Junction 1Montana State University: Solar Cells Lecture 5: P-N Junction.
The Devices: Diode Once Again. Si Atomic Structure First Energy Level: 2 Second Energy Level: 8 Third Energy Level: 4 Electron Configuration:
Putting Electrons to Work Doping and Semiconductor Devices.
Unit-II Physics of Semiconductor Devices. Formation of PN Junction and working of PN junction. Energy Diagram of PN Diode, I-V Characteristics of PN Junction,
Lecture 3. Intrinsic Semiconductor When a bond breaks, an electron and a hole are produced: n 0 = p 0 (electron & hole concentration) Also:n 0 p 0 = n.
Gamma Spectroscopy HPT TVAN Technical Training
Radiation Detection and Measurement II IRAD 2731.
. 2 RCRS provides: Pick-up and delivery of meters Required 9-month calibration Preventive maintenance and repairs Shipping for extensive repairs RCRS.
Detectors The energy loss of particles in matter can be used detect and identify those particles. There are different types of “detectors”: - Gas-filled.
Principles of Radiation Detection
Chapter 6 Principles of Radiation Detection. Measurement of Radiation X-rays and electrons produced by radiation therapy treatment machines are measured.
DETECTION AND MEASUREMENT OF RADIOACTIVITY 1 NANIK DWI NURHAYATI,S.SI,M.SI.
Instruments for Radiation Detection and Measurement Lab # 3 (1)
WEEK ONE TOPIC: ELECTRONICS SOLID STATE MATERIALS  CONDUCTORS  INSULATORS  SEMICONDUCTORS.
1 SEMICONDUCTOR Diodes PN junction and diode biasing Diodes PN junction and diode biasing.
Venugopala Rao Dept of CSE SSE, Mukka Electronic Circuits 10CS32.
1 Semiconductor Detectors  It may be that when this class is taught 10 years on, we may only study semiconductor detectors  In general, silicon provides.
Electronic Devices and Circuit Theory
Semiconductors. A semiconductor is a material whose resistance is between that of a conductor and an insulator. Eg Silicon.
NEEP 541 Ionization in Semiconductors - II Fall 2002 Jake Blanchard.
GERMANIUM GAMMA -RAY DETECTORS BY BAYAN YOUSEF JARADAT Phys.641 Nuclear Physics 1 First Semester 2010/2011 PROF. NIDAL ERSHAIDAT.
Instrumentation Review. Direct and Indirect Ionization Direct - Charge particles that strip away electrons from atoms Indirect - uncharged that have to.
Chapter 1: Semiconductor Diodes. Copyright ©2009 by Pearson Education, Inc. Upper Saddle River, New Jersey All rights reserved. Electronic Devices.
ELECTRONIC PROPERTIES OF MATTER - Semi-conductors and the p-n junction -
Chapter 1: Semiconductor Diodes. Copyright ©2009 by Pearson Education, Inc. Upper Saddle River, New Jersey All rights reserved. Electronic Devices.
Physics of Semiconductor Devices
Introduction to Semiconductors
Lab Experiment: 3 Objectives: To understand the Transistor’s characteristics. Construct the Transistor circuit ( Common base and common emitter connection.
Problems All problems up to p.28 Q 4 can be done.
CHAPTER 4: P-N JUNCTION Part I.
Types of Semiconductor Detectors
UNIT:III SEMICONDUCTOR DIODES. What Are Semiconductors?  Semiconductors are substances that conduct electricity under certain conditions i.e. they require.
Ideal Detector Fast Cheap Rugged Responds to all wavelengths of light Can distinguish different wavelengths Sensitive Low LOD.
Robert Boylestad Digital Electronics Copyright ©2002 by Pearson Education, Inc. Upper Saddle River, New Jersey All rights reserved. Chapter 1: Semiconductor.
CSE251 CSE251 Lecture 2 and 5. Carrier Transport 2 The net flow of electrons and holes generate currents. The flow of ”holes” within a solid–state material.
Neutrinoless double beta decay (0  ) CdTe Semico nductor Band gap (eV) Electron mobility (cm 2 /V/s) Hole mobility (cm 2 /V/s) Density (g/cm 3.
Intrinsic. N-Type P-Type The Diode and PN Junction.
: Prepared By : Name :mohit akabari Enroll. No. : Branch : E.C. Sem. : 3 rd Guided By : 1. Hiren Patel 2. Sandip Gajera.
INTRODUCTION TO SEMICONDUCTORS
3/2003 Rev 1 II.3.5 – slide 1 of 23 IAEA Post Graduate Educational Course Radiation Protection and Safe Use of Radiation Sources Session II.3.5 Part IIQuantities.
Nuclear Medicine Physics Jerry Allison, Ph.D. Department of Radiology Medical College of Georgia Radiation Detectors.
Physics of Semiconductor Devices
More Applications of PN Junction
It converts light energy into electrical energy.
Radiation Protection RTMR 284 CHAPTER 20 PART II.
Physics of Semiconductor Devices Mr. Zeeshan Ali, Asst. Professor
Chapter 1: Semiconductor Diodes
CLRS 321 Nuclear Medicine Physics & Instrumentation I
1 Principles of Radiation Detection Operational Radiological Safety Course U.S. Army Chemical Biological Radiological & Nuclear School Edwin R. Bradley.
Radiation Protection Service University of Glasgow Lecture 2: Detecting Radiation Detecting Ionising Radiation James Gray University RPA.
X-ray detectors single photon detectors
Detecting Ionising Radiation
Semiconductor Diodes Chapter 1 Boylestad Electronic Devices and Circuit Theory.
Presentation transcript:

CLRS 321 Nuclear Medicine Physics & Instrumentation I Part C: Semiconductors and Miscellaneous Scintillation Devices Unit II: Nuclear Medicine Measuring Devices

Objectives Describe n-type and p-type semiconductors and how they function as a radiation measuring device Describe the materials and construction of a semiconductor detector Discuss the detection and counting characteristics of a semiconductor radiation detection device and how these characteristics match up to scintillation detectors Discuss the use of semiconductor detectors in nuclear medicine Describe quality control measures for semiconductor detectors Explain the function of TLD ring and collar dosimeters Describe the function and uses of a liquid scintillation counter

What you need to know about how semiconductors work

Semiconduction Prekeges, J. (2010) Nuclear Medicine Instrumentation. Sudbury, MA: Jones & Bartlett. Figs 3-1 & 3-2, p. 29.

Semiconduction: p-n junction Extra electrons (n-type) move toward the anode Extra holes (p-type) tend to move toward cathode like +electrons When p & n types come together, the holes and electrons diffuse to opposite ends, but end up creating an opposite “intrinsic” charge – Negative charge for p side – Positive charge for n side

P-side has extra holes (which you would think would leave it positively charged) N-side has extra electrons (which you would think would leave it negatively charged) Diffusion of holes and electrons results in the charges pictured and the intrinsic charge Prekeges, J. (2010) Nuclear Medicine Instrumentation. Sudbury, MA: Jones & Bartlett. FigB-9, p. 275.

If the anode (+ terminal) is placed on the n-side, then this is called reverse bias and the depletion layer widens. If the cathode (- terminal) is placed on the n-side, then this is called forward bias and the depletion layer narrows. With reverse bias, the depletion layer becomes a solid- state ionization chamber Prekeges, J. (2010) Nuclear Medicine Instrumentation. Sudbury, MA: Jones & Bartlett. FigB-9, p. 275.

Prekeges, J. (2010) Nuclear Medicine Instrumentation. Sudbury, MA: Jones & Bartlett. Fig 3-4 p. 31.

Detector Type Energy Conversions Gas-filled Detector25-35 eV to make ion pairs Scintillation Detector30 eV for scintillation Semiconductor3-5 eV to make ion pairs FWHM (662 keV Cs-137 Source) NaI(Tl): 6 to 8% Semiconductor:1.8 to 2.5%

Comparison of Information Carriers Prekeges, J. (2010) Nuclear Medicine Instrumentation. Sudbury, MA: Jones & Bartlett. p. 33.

Prekeges, J. (2010) Nuclear Medicine Instrumentation. Sudbury, MA: Jones & Bartlett. Fig3-7, p. 34.

Seminconductor Energy Spectrum Prekeges, J. (2010) Nuclear Medicine Instrumentation. Sudbury, MA: Jones & Bartlett. Fig3-3, p. 30.

Semiconductor Materials Cadmium (Cd), Tellurium (Te), Zinc (Zn) – ZnTe and CdTe common – “CZT” semiconductor (or detector) – Cd and Zn are electron acceptors Have “holes” and thus are p-type – Te is an electron donor Extra electrons and thus an n-type

Semiconductor Probes Often have surgical applications – Sentinel node biopsy – Parathyroid adenoma localization – Tumor localization _SectionID=9&Nav_CatID=9_DeviceDevelopment&Nav_Cont entKey={74FFB370-37E6-486A-8D46-DE7E9E29715E}

Prekeges, J. (2010) Nuclear Medicine Instrumentation. Sudbury, MA: Jones & Bartlett. Fig 3-6 p

Quality Control for Semiconductor Probes Daily: – Battery Check – Background Determination – Constancy Check (using Co-57 source) Quarterly or semiannually: – Calibration (may need to be done by manufacturer) NEMA recommendations (annually): Sensitivity in air and scattering medium Energy, spatial, and angular resolution Volume sensitivity Count rate capabilities

Liquid Scintillation Detector Usually used in laboratories to count beta emitters. Solvents dissolve radioactive samples (often purposely radiolabelled) in to vials. Radioactivity scintillates a set of solutions in the vials. PMTs detect light from the “scintillation cocktails” in the vials. No longer routinely used in nuclear medicine

Radiation Detection (formerly known as “film”) badges Al 2 O 3 crystalline material becomes luminescent under selected laser frequencies. Luminescence is proportional to the amount of radiation exposure.

Thermoluminescent Dosimetry (TLD Ring Badges) Uses a lithium fluoride chip that absorbs the energy of ionizing radiation. It is then heated at characteristic temperatures that cause it to emit the absorbed energy as visible light. The amount of exposure is determined by the light intensities.

The Plan o Complete Homework 7 by 1:00 PM Wednesday, November 6 th o We will review this (and grade) in lab on Wednesday o Unit II Test will be on Monday, November 11 th