Consequences of particles formation Increase in total surface area Local tissue response and release of cytokines involved in bone resorption Biological.

Slides:



Advertisements
Similar presentations
Synthetic BIOMATERIALS
Advertisements

Hip Arthroplasty.
Total Hip Replacements About 160,000 THRs performed every year 90% of all hip replacements need some sort of revision No. 1 reason for revision is loosening.
TOTAL HIP REPLACEMENT Presented by: Atillio Castellani Brendan Cochren
Arthroplasty.
The Swedish Total Hip Replacement Register by Henrik Malchau, Peter Herberts, Thomas Eisler, Göran Garellick, and Peter Söderman J Bone Joint Surg Am Volume.
Hip Arthroplasty Chris Oser. Presentation Why hip replacement? How? –Surgery! Different materials Pros and Cons Resurfacing Patient post-op.
WHAT MUST BE A WELL-CEMENTED PROSTHESIS?
Advanced Treatment Options for Knee Arthritis Surgeon Name Clinic Name Clinic Address Phone Number Web Address.
History of THA Luke Gauthier January 6, 2011.
 Mechanical Engineering Proposal Seminar Project title Design of fretting corrosion testing set-up for hip joint implants Student - Ivon Tshinkobo Project.
Dr. R. Coup Whangarei Hospital. Recent Concerns Prevention Approach to Patient.
1 The following presentation was given at the Radiological Society of North America (RSNA) in 2012 Multimodality Assessment of Metal-on-
Periprosthetic Fractures
Instructional Course Lectures, The American Academy of Orthopaedic Surgeons - Periprosthetic Fracture of the Femur after Total Hip Arthroplasty. Treatment.
OSTEONECROSIS OF THE FEMORAL HEAD: Modern Results of Total Hip Arthroplasty Daniel J. Berry, MD Prof and Chairman Mayo Clinic Rochester, MN.
Newcastle University CREST Extending prosthesis longevity through tribological understanding James Lord & Dr Tom Joyce.
Aseptic loosening of Hip Prostheses
بنام خداوند جان وخرد. Reasons for Hip Replacement Osteoarthritis (OA) Trauma and post-traumatic arthritis Congenital deformities Bone tumors Avascular.
CAUSES , FEATURES AND TREATMENT OF LOOSENING IN THR
Tissue Engineering: a new healthcare technology. Biomaterials Biomaterials science may be the most multidisciplinary of all the sciences which encompasses.
Paris 2003 Wear of UHMWPE cup and component loosening in total hip arthroplasty Professor B.M. Wroblewski P.D. Siney P.A. Fleming The John Charnley Research.
Failure of a Stainless-Steel Femoral Head of a Revision Total Hip Arthroplasty Performed after a Fracture of a Ceramic Femoral Head. A Case Report* by.
Materials. Materials used as replacement parts in the skeletal system include: Silicone Ultra High Weight Polyethylene (UHMWPE) Super Alloy Cement – to.
B. AmsdenCHEE 340 BIOMATERIALS OBJECTIVES To introduce the different biomaterials used in biomedical engineering, provide some fundamental properties of.
DePuy Hip Implant Litigation. DePuy Hip Implant Recall DePuy Orthopaedics is the subsidiary of Johnson & Johnson. 8/24/2010 – DePuy Orthopaedics voluntarily.
Reviewed by: Name: AGNES Purwidyantri Student ID No: D Basics of Orthopedic Implants.
Lec # Joint Prosthesis.
11 STEFANO ZANASI VILLA ERBOSA HOSPITAL GRUPPO SAN DONATO ORTHOPAEDICS DEPARTMENT III RD DIVISION – JOINT ARTHROPLASTY OPERATIVE CENTER CHIEF: STEFANO.
Dr. Pete Rose Joint Replacement. Total = Ball + Socket.
The Development of Metallic Biomaterials Roger J Narayan MD PhD Associate Professor, North Carolina State University and the University of North Carolina.
Hip Implant -Thin Film Improved-
1 1 Case A: THA Revision 43 year old male Index THA revised in 1995 due to loosening Subsequently revised in 2004 using long stem via trochanteric osteotomy,
Contact Mechanics in Hip Prosthesis Dan Flavin. Background Prosthetic hips a common replacement joint in the US. Artificial ball and socket to replace.
2008/07/23. A. Grubl et al JBJS (B), Aug 2006,  Polyethylene debris, wear particles  peri- prosthetic osteolysis  long-term failure  Change bearing.
Revision Total Knee Arthroplasty Using Femoral Head Structural Allograft Corey J. Richards, MD, MASc, FRCSC Luke Pugh, MD Donald S. Garbuz, MD, MHSc, FRCSC.
Orthopaedic implant components as a source of nanoparticles Ingrid Milošev Jožef Stefan Institute, Ljubljana, and Valdoltra Orthopaedic Hospital, Ankaran,
Total Hip Arthroplasty BME 181 By: Erik Walder. What is total hip arthroplasty? Total Hip Replacement Bone is sheared away and an artificial hip is implanted.
MATT MAC ANDREW AND DREW 1 ST BLOCK-SNEEDBIOTECH Joint Redesign Project.
Some “short term” medical applications of degradable polymeric biomaterials.
REPLACEMENT ARTHROPLASTY FOCUSED ON THE KNEE Katherine Noonan BME /16/12.
UHMWPE Superalloy Polyethylene Cemented & Uncemented
Instructional Course Lectures, The American Academy of Orthopaedic Surgeons - Fixation with a Modular Stem in Revision Total Hip Arthroplasty*† by JAMES.
Percolation Mechanism in Biotribology Kyle Jones AME Department University of Notre Dame Advisor: Dr. Schmid.
Understanding Why Metal-on-Metal Hip Arthroplasties Fail by Alister J. Hart, Ashley Matthies, Johann Henckel, Kevin Ilo, John Skinner, and Philip C. Noble.
Categories of Biomaterials
Comparison of Ten-Year Survivorship of Hip Prostheses with Use of Conventional Polyethylene, Metal-on-Metal, or Ceramic-on-Ceramic Bearings by Ingrid Milošev,
Osteolysis in Association with a Total Hip Arthroplasty with Ceramic Bearing Surfaces* by TAEK RIM YOON, SUNG MAN ROWE, SUNG TAEK JUNG, KWANG JIN SEON,
All Things Arthoplasty Outcome and complication Dr. Bahaa Ali Kornah, Prof. Of Orthopedic and Trauma Al-Azhar University Cairo. Egypt.
Metal Allergies in Arthroplasty Michael Zlowodzki MD University of Minnesota Department of Orthopaedic Surgery.
Revision Hip Replacement Richard Boden Consultant Trauma and Lower Limb Orthopaedic Surgeon (locum) Lancashire Teaching Hospitals NHS Foundation Trust.
Mr A Bayan MBChB, FRACS(Ortho) Orthopaedic Surgeon.
CONCLUSION It’s clear that shoulder prosthesis is efficient in comfort and function restoration, and its main visible benefits are pain relief and the.
“EPIDEMIOLOGY OF REVISION ARTHROPLASTY ” SINGLE CENTRE STUDY Gp Capt V Kulshrestha, Col B Datta Lt Col Gaurav Mittal, Wg Cdr Santhosh Kumar Joint Replacement.
DESIGN AND SELECTION OF MATERIALS FOR ARTIFICIAL HIP JOINTS Asst. Prof. Dr. Ali Sabea Hammood University of Kufa -Faculty of Engineering MATERIALS ENGINEERING.
Artificial Hip Replacement
DUAL MOBILITY CUPS – KHOULA Hospital EXPERIENCE Dr. Jatinder S. Luthra MS, DNB, MRCS Dr. Mohamad Kasim Allami FRCS, FRCS ( Trauma & Ortho)
1. 2 Si 3 N 4 Cr 3 Si Cr 2 N Cr powder Si N Cr Si 3 N 4 CrSiCrSi 2 Cr 3 Si 2 Cr 3 Si Cr 2 N  stable Si 3 N 4 -Cr 3 Si interface  unstable Si 3 N 4 -Cr.
American Joint Replacement Registry
Implant: مادة سنية / د . زينة ثاني اسنان موصل 12 / 4 / 2016
Senior Science Bionics
SENIOR SCIENCE BIONICS
American Joint Replacement Registry
Discuss success rates for the procedure Discussion Points Assure the patient that knee replacement is one of the most successful orthopedic surgeries.
THR designs and options for complex hips
Nahhas, M., Turcotte, R.E. and Isler, M.
Volume 1, Issue 4, Pages (December 2015)
Mysterious Rash in a Patient with Congenital Hip Dysplasia
What’s New in Hip Replacement
Biomaterials Dr. Ahmed Moro.
Presentation transcript:

Consequences of particles formation Increase in total surface area Local tissue response and release of cytokines involved in bone resorption Biological response

B.F. Morrey, Biological, Material, and Mechanical Considerations of Joint Replacement, 1993 Local tissue response Biological response

Consequences of particles formation Increase in total surface area Local tissue response and release of cytokines involved in bone resorption Systemic effects Biological response

Hip prosthesis implanted 2-year post- op Systemic effect of metal particles– blood and urine I. Milošev, P. Campbell, V. Pišot, J.Orhop. Res., 23 (2005) Biological response

Consequences of particles formation Increase in total surface area Local tissue response and release of cytokines involved in bone resorption Systemic effects Transport of particles to distant organs Potential for carcinogenesis and hypersensitivity Biological response

Metal sensitivity Skin test for metal sensitivity are not correlative and are unable to predict delayed metal hypersensitivity !

Willert HG et al., Osteologie (2000), World Tribology Forum in Artroplasty (2001) Delayed Type Hypersensitivity (DTH) related to the use of metal-on-metal prostheses: Diffuse and perivascularly oriented lymphocyte infiltration Macrophages (sometimes with drop-like inclusions) Plasma cells* Infiltrates of B-lymphocytes* Massive fibrin exudations* Clinical status: pain

Concluding remarks Benefits of total joint replacements are most important fot the patient. We should be aware, however, that loosened implant components are a source of various types of nanoparticles – metal, polyethylene, PMMA and ceramic. Knowledge on their morphology and composition contributes to the understanding of failure mechanism. Efforts are directed to the prolongation of life- time of implants by increasing their wear resistance. Joint collaboration studies between medical and research community are necessary.

Acknowledgments Orhopaedic surgeons at the Valdoltra Orthopaedic Hospital (V. Pišot, R. Trebše, S. Kovač) Vesna Levašič, MD, Arthroplasty register Prof. Andrej Coer, University of Primorska, pathology specialist Dr. Maja Remškar, Jožef Stefan Institute Thank you

Ceramic particles origin: femoral head acetabular inlay Wear debriswww.endoplus.com

Novel bearing combinations Lower wear implies a lower number of wear debris particles and, consequently, a decreased incidence of aseptic loosening. However, other problems may arise.

Primary hip and knee total hip replacements at the Valdoltra Orthopaedic Hospital

Femoral head Femoral stem, Femoral stem Femoral head, Fracture plate femoral head acetabular inlay acetabular inlay Stainless steel Cobalt- base alloys Titanium- base alloys Ceramics + price availability Wear resistance Corrosion resistance Fatique resistance Corrosion resistance Elastic modulus Fatique resistance Specific density Biocompatibili ty Wear resistance Corrosion resistance Specific density Biocompatibili ty - Elastic modulus Biocompatibili ty Elastic modulus Biocompatibili ty Elastic modulus Biocompatibili ty Elastic modulus Fracture

Diffusely distributed lymphocytic infiltrates Perivascular lymphocytic infiltrates

Origin of wear debris and their transport in the body A – Cemented prostheses; B – Uncemented prostheses H.-G. Willert, et al., “Biological, Material and Mechanical Considerations of Joint Replacement”, 1993 Wear debris wear debris particles

Bone cement particles origin: femoral stem acetabular cup Wear debris Cortical bone Cancellous bone Bone cement Polyethylene Metal

Ceramic wear particles Wear debris

Procedure for isolation of metal and polyethylene particles from periprosthetic tissue using hydroxide digestion Digest minced tissue in 5M NaOH at 65 o C Ultrasonicate for 10 minutes Centrifugate at 6000 rpm for 1h Top layer contains polyethylene particles Bottom layer contains metal particles Hydrolyse at 80 o C for 1h Ultrasonicate for 5 minutes Add 3 ml of isopropanol Centrifugate at 6000 rpm for 1 h Wear debris

Hip prosthesis explanted 2-year post- op Systemic effect of metal particles– blood and urine I. Milošev, P. Campbell, V. Pišot, J.Orhop. Res., 23 (2005) Biological response

Cr-O-particle Ti-particle

Ca-P-O-particle Different composition of particles arises from the formation of solid lubricating layer at the surface containing denatured proteins and metal oxides. I. Milošev, M. Remškar, J. Biomed. Mater. Res., in press

Different composition of particles arises from the formation of solid lubricating layer at the surface containing denatured proteins and metal oxides. a c b a c b