University of Minnesota Hospital and Clinics Minneapolis, MN presents

Slides:



Advertisements
Similar presentations
” سبحانك لا علم لنا إلا ما علمتنا إنك أنت
Advertisements

Toxic Heavy Elements1 National Seminar On Toxicity Of Chemicals & their Hazards With SPECIAL REFERENCE To Heavy Metals” 23rd – 24th, October, 2008 St.
Anesthesia & ASD Occluder Presented By R3 顏郁軒 93/8/9.
Amplatzer® Septal Occluder
Disclosure Information Devices for ASD&PFO Closure: Amplatzer Devices As a faculty member for this program, I disclose the following relationships with.
Update of Transcatheter Closure of Ventricular Septal Defect in China Yong-wen Qin Department of Cardiology, Changhai Hospital, Second Military Medical.
EOH:2504 Principles of Environmental Exposure Instructor: Dr. Volz Yi-Han Huang EOH MPH student Dec
Percutaneous mitral valve repair using the MitraClip® device (e-valve)
Percutaneous Closure of Patent Foramen Ovale Sponsors: Kung Ming Jan, M.D., Ph.D. Judah Weinberger, M.D., Ph.D. Columbia University Medical Center Department.
Journal Club Alcohol and Health: Current Evidence July-August 2006.
Atrial Septal Defect Closure
Current Status and Prospect of Interventional Congenital Heart Disease
Impact of Concomitant Tricuspid Annuloplasty on Tricuspid Regurgitation Right Ventricular Function and Pulmonary Artery Hypertension After Degenerative.
Early Nutritional Support Influences Body Composition at Four Months Corrected Age in Very Low Birth Weight Preterm Infants Ellen C Christiansen, MD 1,
DUCTAL STENTING THROUGH LEFT INTERNAL CAROTID ARTERY IN A 5 YEAR OLD MALE WITH PULMONARY VALVE ATRESIA: A CASE REPORT Bee Jane T. Martinez, MD UP-PGH Department.
Abstract A patient who had transcatheter closure of a large patent ductus arteriosus in early infancy developed aortic coarctation during follow-up. Initially.
Transhepatic venous cardiac catheterization
A Prospective, Multicenter, Randomized trial to Assess Efficacy and Safety of the CERA Occluder in Congenital Heart Disease (ASD/VSD/PDA): CERA TRIAL Zhi-wei.
Pulmonary Atresia with Intact Ventricular Septum Ali Sepahdari, MD University of Illinois at Chicago.
Department of Cardiolog Shenyang Northern Hospital
Activity series Experiment # 15.
Transcatheter ASD closure, sans X-rays Peter Ewert MD Robert Beekman MD.
By Miss Buicke Metals and Non-metals. What we need to know from the syllabus : OC45 understand that rusting is a chemical process that changes iron into.
Percutaneous Establishment of Tricuspid Regurgitation: An Experimental Model for Transcatheter Tricuspid Valve Replacement Yuan Bai, Gang-jun Zong, Yong-wen.
One-stage repair for Stanford Type B Aortic Dissection concomitant with cardiac diseases Open stented elephant trunk technique combined with cardiac operation.
By M.elkhatib.  Equal  R = L  Q refers to flow  Therefore Qp = Qs  Blood flow to both the pulmonary & systemic circulations is balanced.  Homeostasis.
Metal alloys DR.LINDA MAHER.
Ostium Secundum Atrial Septal Defect Closure Thomas Hoy April 14, 2004 Department of Biomedical Engineering BME 273 Senior Design.
Can we improve the management of angina patients after percutaneous coronary intervention? Beneficial effects of adding trimetazidine MR therapy after.
Date of download: 5/28/2016 Copyright © The American College of Cardiology. All rights reserved. From: Pediatric Cardiac Interventions J Am Coll Cardiol.
HRG4: Impact on Arrhythmia Care Donna Elliott-Rotgans Cardiology Service Manager UCLH / The Heart Hospital.
Is there any role for intravascular ultrasound in bifurcation lesions? Giuseppe Biondi-Zoccai, MD University of Turin, Turin, Italy.
H. Amoozgar, MD Professor of pediatric cardiology Shiraz University of Medical Sciences, Shiraz, Iran TRANSCATHETER CLOSURE OF LARGE CORONARY-CAMERAL FISTULAE.
Why Treat Patent Forman Ovale Clifford J Kavinsky, MD, PHD Professor of Medicine and pediatrics Associate Director, Center for Congenital and Structural.
MitraClip Mitral Valve Repair System Abbott Vascular MitraClip Mitral Valve Repair System Abbott Vascular Alexandra Camesas & Nathan Kukowski Biomaterials.
Principles of prevention of infection Yaser Baroud.
HIGH TEMPERATURE CORROSION PROPERTIES OF IONIC LIQUIDS. Ilaria Perissi, Ugo Bardi, Stefano Caporali, Alessandro Lavacchi Dipartimento di Chimica, Consorzio.
Date of download: 9/19/2016 Copyright © The American College of Cardiology. All rights reserved. From: Percutaneous Aortic Valve Replacement Will Become.
© free-ppt-templates.com 2017 AHA/ACC Focused Update of Valvular Heart Disease Guideline of 2014 DR. OMAR SHAHID TR CARDIOLOGY SZH.
VSD post TAVR: Mechanisms, Presentation and Management
M-Guard stent in STEMI patients with high thrombus burden lesions Mahmoud Shabestari Baktash Bayani Ali Eshraghi Bahram Shahri Mashhad University.
Cardiovascular system
Nat. Rev. Cardiol. doi: /nrcardio
Prof. Dr. med. H. R. Figulla Director at the University Hospital Jena
Challenging Case Presentation For Structural Heart Disease Program
What´s New in the Literature on Transradial Intervention
Mitralign Program Update
Direct transthoracic access ports to the heart and non-surgical closure Robert J. Lederman, MD Senior Investigator Cardiovascular & Pulmonary Branch,
TAVR-Endocarditis Tarek Chami, MD
Hans R. Figulla MD,PhD University Heart Center, Jena, Germany
Trans-Apical Aortic Valve Implant:
Cardiac Manifestation of DiGeorge Syndrome
One-stop Hybrid Cardiac Surgery
THE “UNDER-LINING” CAUSE OF RIGHT HEART FAILURE AFTER CARDIAC SURGERY
Micro & Macro Nutrients Soil Nutrient Relationship to Livestock
Percutaneous Intervention for Recurrent Aortic Insufficiency in a Patient With a Left Ventricular Assist Device and a Centrally Oversewn Aortic Valve by.
Mechanical failure of prosthetic human implants: A 10-year experience with aortic stent graft devices  Tikva S. Jacobs, MD, Jamie Won, BS, Edwin C. Gravereaux,
Late Follow-Up from the PARTNER Aortic Valve-in-Valve Registry
BENEFIT Trial design: Patients with positive serologic tests for T. Cruzi and cardiomyopathy were randomized to benznidazole 300 mg daily for days.
CANOA Trial design: Patients undergoing percutaneous closure of an ASD with the Amplatzer Septal Occluder were randomized to aspirin 80 mg plus clopidogrel.
Balu Vaidyanathan, Sumantha Sekhar Padhi, Ananthen KS, BRJ Kannan,
Shafkat Anwar et al. BTS 2018;3:
Advances in Experimental Percutaneous Pulmonary Valve Replacement
Explant analysis of AneuRx stent grafts: relationship between structural findings and clinical outcome  Christopher K Zarins, MD, Frank R Arko, MD, Tami.
Hidehiko Hara et al. JIMG 2008;1:92-93
SEM and EDX study of Stainless Steels, Suggested as Biomaterials
Nat. Rev. Cardiol. doi: /nrcardio
UK paediatric cardiac surgery 30-day mortality rates for individual specific procedures by era (2000–2004 compared with 2005–2010). UK paediatric cardiac.
Evaluation of a new hybrid technique for closure of muscular ventricular septal defects in a long-term setting  Rainer Kozlik-Feldmann, MD, Nora Lang,
Endoluminal Closure Device
Presentation transcript:

University of Minnesota Hospital and Clinics Minneapolis, MN presents Kurt Amplatz MD University of Minnesota Hospital and Clinics Minneapolis, MN presents Recorded at the 3rd Pediatric Interventional Cardiac Symposium, September 1999, in Chicago, Illinois.

Nickel toxicity: what is the issue?

Société Française de Cardiologie Conclusions: CardioSEAL 1. no nickel 2. less bulky 3. better endothelialization

CardioSEAL metal The metal of our competitor is MP35N with a 33% nickel content!

Amplatzer® devices from Felix Berger MD Fig. 1 Implanted high-profile Amplatzer devices

Nickel allergy Nine percent of the population is allergic to nickel. However implantation of nickel-containing prostheses and devices virtually never causes problems.

Allergy and nickel-containing implants Dear Dr. Amplatz, Many thanks for answering about percutaneous closure of ASD with the Amplatzer device in patients with allergy to nickel. As you know, I decided to perform the procedure in this young lady that presented with a cutaneous allergic reaction to nickel: The procedure was uneventful and at one month follow-up, no shunt was detected by Echo and she is doing fine… Eustaquio Onorato MD Clinica San Rocco Di Franciacorta SpA Ome, Italy

An essential element Nickel is an essential element for nutrition. Lack of nickel results in retarded body growth, anemia, and increased neonatal mortality in experimental animals. Inorganic elements essential for life: Cu, Zn, Se, Mg, Mn, Ca, Fe, Mo, Ni, etc

Toxicity Paracelsus (1493–1541): The factor determining whether a compound is toxic or not depends on the dose

Intake of nickel Daily intake of nickel in the United States ranges from 300 to 600 micrograms per day. Most of the ingested nickel is excreted via feces, urine, bile, and sweat.

Exposure to nickel Nickel-containing alloys used in: coins (quarters, nickels, euros) knives, forks, spoons, etc implants: wires, clips, coils, stents, nails, cava filters, prostheses, heart valves, pacemakers, etc

Anodic corrosion test Fig. 2 Nitinol wire corroded by anodic dissolution for 2 minutes at 6 mA. Pits and corrosion products are obvious.

Explanted orthodontal arch wires Control Explanted wire Fig. 3 Nitinol arch wire explanted at 1 month shows no evidence of corrosion.

Implanted Amplatzer devices Amin Z, et al. Circulation 1999;100:320-328 Fig. 4 Amplatzer devices implanted in a dog with 2 ventricular septal defects. The second device is a "dog-bone" design that was investigated in some animals.

Follow-up at 1 week Fig. 5 One week after implantation, there is complete closure of the communication.

Follow-up at 1, 14, and 18 months Fig. 6 At one-month follow-up, there is no change. Inspection at 14 and 18 months (not shown) confirms the same and demonstrates no aortic or tricuspid insufficiency.

Cardioscopy of right disks First device Second device Fig. 7 Right side of the device is completely endothelialized.

Cardioscopy of the left disks and valves Fig. 8 Left side of the device shows complete endothelialization, except of the post. Cardioscopy, in other views (not shown), confirms normal aortic, mitral, and tricuspid valves.

Explanted Amplatzer devices First device Second device Fig. 9 Amplatzer devices, explanted at 18 months and polyester fabric removed, are indistinguishable from brand-new devices. There is not a single wire broken.

Human experience September 1995: first implant in a patient Masura J, et al. Cathet Cardiovasc Diagn 1997;42:388-393 September 1995: first implant in a patient November 1998: device is intact and shows only total heart motion

Nickel toxicity Nickel toxicity occurs exclusively in nickel refineries due to inhalation of nickel carbonyl, Ni(CO)4, being part of the Mond process.

Explanted devices under light microscopy Fig. 10 The explanted Amplatzer devices under light microscopy reveal a perfectly shiny surface with no evidence of pitting.

Explanted devices under scanning electromicroscopy End disk Disk with female screw Fig. 11 Scanning electromicroscopy again reveals no corrosion of the explanted devices.

Explanted devices at x3000 magnification Control Explanted wire Fig. 12 At x3000 magnification, the explanted Amplatzer devices still show no corrosion. At this magnification, 1 mm would measure 3 m!

Nickel corrosion in a biologic environment A corrosion of 10% would produce a huge crater at 3000 times magnification and the daily dose of nickel would have been 15.4 micrograms, 33 times less than the daily intake.

Conclusion Edie JW, et al. Angle Orthod 1981;51,4:319-24 “In conclusion, the results reported here suggest that there is no reason to believe that Nitinol wires are any more subject to corrosion than stainless steel wires in an environment that is typical of clinical service.” Edie JW, et al (1981)